0% found this document useful (0 votes)
267 views14 pages

Three Story Residence Mandaluyong

The document provides design criteria for a proposed three story residential building including references, design loads, live loads, seismic loads, design stresses, soil bearing pressure and structural design analysis for beams, tie beams, columns, footings and slabs. References cited include codes from the American Concrete Institute and National Structural Code of the Philippines. Loads and design stresses are defined for the concrete, reinforcing steel and structural steel. Sample calculations are provided for the design of specific structural elements.

Uploaded by

Sayra Saporna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
267 views14 pages

Three Story Residence Mandaluyong

The document provides design criteria for a proposed three story residential building including references, design loads, live loads, seismic loads, design stresses, soil bearing pressure and structural design analysis for beams, tie beams, columns, footings and slabs. References cited include codes from the American Concrete Institute and National Structural Code of the Philippines. Loads and design stresses are defined for the concrete, reinforcing steel and structural steel. Sample calculations are provided for the design of specific structural elements.

Uploaded by

Sayra Saporna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 14

DESIGN CRITERIA

1.0 REFERENCES:

1.1 American Concrete Institute (ACI-318-83)


1.2 National Structural Code of the Philippines for Building
1.3 Uniform Building Code
1.4 ASEP Steel Design Manual
1.5 Design of Reinforced concrete 2nd Ed. By Jack C. Mac Cormack
1.6 Foundation Design by WAYNE V. TENG
1.7 Structural Design Data and Specifications, 6 th edition by Abelardo B. Carillo

2.0 DESIGN LOADS

2.1 Unit Weight of Concrete 24.00 kpa


2.2 Superimposed dead loads 3.00 kpa
2.3 Unit weight of 6" chb 2.74 kpa
2.4 Unit weight of 4" chb 2.11 kpa
2.5 Unit weight of ceiling 0.48 kpa
2.6 Unit weight of Topping, Finishing 1.90 kpa
2.7 Partition loads 0.96 kpa

3.0 LIVE LOADS

3.1 Ground floor


3.2 2nd floor, Third floor
3.3 Roof
3.4 Stairs
3.5 Toilets

4.0 SEISMIC LOADS

5.0 Conforms to the requirements of the national structural codes of the Phils.
6.0 DESIGN STRESSES

6.1 Min. compressive strength of concrete @ 28 days


Footing , column fc' 20.7 mpa
6.2 Suspended slans and canopies fc' 20.7 mpa
6.3 Slab on fill 20.7 mpa
6.4 Min. yield strength of reinforcing steel bars Fy 20.7 mpa
6.5 All bars shall be deformed bars and conform to ASTM designation
6.6 For 12mm dia. Or less 230 mpa
6.7 For bars greater than 12 mm dia. 275 mpa
6.8 For column vertical bars Fy 275 mpa
6.9 For structural steel Fy 248 mpa
6.10 Eccentricity strength 200,000 mpa

7.0 SOIL BEARING PRESSURE 100 kpa


DESIGN OF B-1

Dead load:
Wt. of beam 24 (.20) (.40) 1.92
Wt. of slab .10 (24) (4.0) 9.60
Wt. of ceiling .48 (4.0) 1.92
Wt. of Part. .96 (2.40) 2.30
15.74
Live load: 1.929(4.0) 7.72
DESIGN ANALYSIS:
Wu = 1.4 dL + 1.7 LL
= 1.4 (15.74) + 1.7 (7.72)
Wu = 35.16 kn-m
Mu = WL2 = 35.16(4.0)2 = 70.32
8 8
P = As = π (16)2/4 (8) = .022
Bd 200(362)
d=400-20-10-8= 362 mm
Pmin = 1.4 = 0.005
Fy 275 600
Pmax = 0.75 (.85) β1 (fc') (600 + Fy)
Fy 600
= 0.75 (.85) (.85)(20.7) (600 + 275)
275
Pmax = .028
Mu allow = φ Pbd2 Fy (1-0.59 Fy /fc')
= .90 (.022) (200) (362)2 (275)
(1-0.59 (.022)(275)/20.70)
Mu allow = 118.10 > 70.32 kn-m

STEEL REINFORCEMENTS:
As =Pbd
= .022 (200) (362)
As = 1,592.80 mm2
Using 16 mmø
n = As = 1,592.80 = 7.92 say 8 pcs.
π d2/4 π (16)2/4

.: Use 8 pcs. 16 mm/ 10mm ø stirrups [email protected], [email protected]


[email protected] rest @.20 mm.o.c.
DESIGN OF TB-1

Dead load:
Wt. of beam 24 (.20) (.40) 1.92
Wt. of slab .10 (24) (4.0) 9.60
Total DL 11.52
Live load: 2.40(4.0) 9.60
DESIGN ANALYSIS:
Wu = 1.4 dL + 1.7 LL
= 1.4 (11.52) + 1.7 (9.60)
Wu = 32.45 kn-m
Mu = WL2 = 32.45(4.0)2 = 64.90
8 8
P = As = π (16)2/4 (8) = .022
Bd 200(362)
d=400-20-10-8= 362 mm
Pmin = 1.4 = 0.005
Fy 275 600
Pmax = 0.75 (.85) β1 (fc') (600 + Fy)
Fy 600
= 0.75 (.85) (.85)(20.7) (600 + 275)
275
Pmax = .028
Mu allow = φ Pbd2 Fy (1-0.59 Fy /fc')
= .90 (.022) (200) (362)2 (275)
(1-0.59 (.022)(275)/20.70)
Mu allow = 118.10 > 64.90 kn-m

STEEL REINFORCEMENTS:
As =Pbd
= .022 (200) (362)
As = 1,592.80 mm2
Using 16 mmø
n = as = 1,592.80 = 7.92 say 8 pcs.
π d2/4 π (16)2/4

.: Use 8 pcs. 16 mm/ 10mm ø stirrups [email protected], [email protected]


[email protected] rest @.20 mm.o.c.
DESIGN OF COLUMN -1

DESIGN CRITERIA:

Fc' 3,000 psi 20.7 mpa


Fy' 40,000 psi 275 mpa
Ag 350(350) 122,500 mpa

Assume Pg 0.013
Ag = 350(350) 122,500 mpa
Ast = .013 (122,500)
Ast = 1,592.50 mm2
n = 1,592.50 / 201.10 = 8 pcs.
Ast = π(16) (8) 2
= 1,608.50
4
Pg = 1,608.5 = .013>.013
122,500
REINFORCEMENTS:

Ast = Pbd
= .013(350)(350)
Ast = 1,592.50 mm2

Using 16 mmø

N = Ast 1.592.50 = 8 pcs.


π d /4
2
π(16) /4
2

.: Use 8- Pcs. 16 mmø


DESIGN OF FOOTING-1

Allowable soil bearing 100 kpa


Allow. Conc. = 24 kn/m3
Allow. Soil = 20 kn/m3

Loading: 58 kn
Footing Area:
q1 = 24 (.30) = 7.20 kn/m2
By fill
q2 = 20 (2.70) = 54 kn/m2

Eff. Soil Pressure:


Qe = 100-54-7.20= 38.80
A req = 58 / 38.80= 1.49 m2
A actual = 1.50 m2 > 1.49 m2

STEEL REINFORCEMENTS:
d=300-70 = 230 mm
: use P = Pmin.

Ast= .005(1500)(230)
Ast= 1,725 mm2

Using 16 mmø

N= As = 1,725 = 8.58 say 9 pcs.


π d /4
2
π (12) /4
2

.: Use 9 pcs. - 16 mmø both ways


PROJECT : PROPOSED THREE STOREY RESIDENTIAL BUILDING
WITH ROOF DECK

LOCATION : I. LOPEZ STREET, BARANGAY ZANIGA,


MANDALUYONG CITY

OWNER :

SUBJECT : STRUCTURAL DESIGN ANALYSIS

Engr. EDUARDO V. QUINTOS IX


PRC # 38687
PTR # 9328187
Date 1-20 2011
Place :Manila
DESIGN OF COLUMN -2

DESIGN CRITERIA:

Fc' 3,000 psi 20.7 mpa


Fy' 40,000 psi 275 mpa
Ag 200(350) 70,000 mpa

Assume Pg 0.013
Ag = 200(350) 70,000 mpa
Ast = .013 (70,000)
Ast = 910.00 mm2
n = 910.00 / 201.10 = 4 pcs.
Ast = π(16) (4)
2
= 804.25
4
Pg = 804.25 .013>.011
70,000
REINFORCEMENTS:

Ast = Pbd
= .011(200)(350)
Ast = 804

Using 16 mmø

N = Ast 804.25 4 pcs.


π d /4
2
π(16) /4
2

.: Use 4- Pcs. 16 mmø


DESIGN OF SLAB

tslab = L
24

= 3150
24

tslab = 131.25 say 150 mm

d = 150 - 20 -10/2
= 125 mm

WDL = 11.52 (1) = 11.52 KN/m


WLL = 9.60 (1) = 9.60 KN/m

Mu = 1.40 DL + 1.70 LL

= 1.4 11.52 (4.02) + 24(0.100)(1.0)(4.02) + 1.7 9.6 (4.02)


8 8 8

Mu = 71.62 KN.m

K = Mu = 71.62 x 106 =
5.09
f b d2 0.9(1000)(1252)

ρ = fc' 1 - 1 - 2.4 (k/fc') 20.7 1 - 1


=
fy 1.18 275 1.18

ρ = 0.02246

Check for Ductility Requirements

1.4
ρmin = = 0.00509
275
0.85 (0.85)(20.70) 600
ρmax = 0.75
275 600 + 275

ρmax = 0.02797

ρmin < ρ < ρmax

Ok!

As = ρ b d
= (0.01406)(1000)(100)
As = 2246 mm2

S 1000 Temp. bars


=
A10 As From ACI
As temp =
S 1000 =
=
78.5 2246 Stemp 1000
=
A10 As temp
S = 34.97
say 150 mm Stemp 1000
=
78.54 225
From ACI
3h Stemp = 349.07
Smain bar <
450mm say 350 mm
450 From ACI
150 mm <
450mm
Stemp bar <
Ok!

150 mm <

Ok!
Use , 10mm ø main bars spaced @
150 mm Use , 10mm ø temp. bars spa
150 mm

10 mm ø spaced @ 150mm O.C.,


bothways
- 2.36 (5.09/20.70)
1.18
0.0018bh
270 mm

349.07
350 mm

5h
450mm
625
450mm
0mm ø temp. bars spaced @
150 mm

ed @ 150mm O.C.,