FCC Emergency Interlock System
FCC Emergency Interlock System
Refining
Refining
The UOP FCC Emergency Interlock System is a protec- 쮿 Refinery power loss
tion system designed to automate the required operator 쮿 Pump failures
actions during an abnormal event affecting the catalyst 쮿 Cooling water failure
sections of a fluidized catalytic cracking (FCC) unit.
쮿 Instrument air failure
These abnormal events require immediate and precise
쮿 Main air blower failure
operator action. Given the nature of human response to
emergencies, it is possible that the operator will either 쮿 Slide valve failure
delay action or make an error in judgment. These abnor- 쮿 Other equipment failures
mal events may result in major equipment damage, long
down time and/or lost production. UOP FCC EIS design
To protect the FCC unit from an array of problems, UOP
Background
developed the UOP FCC Emergency Interlock System
The FCC process employs a fluidized catalyst system (EIS). The UOP FCC EIS is an independent protection
that converts straight-run atmospheric gas oil, vacuum layer for the FCC process, following the requirements
oils and other side products into high octane gasoline, of ANSI/ISA S84.01 (Application of Safety Instrumented
light fuel oils and olefin-rich light gases. Systems for the Process Industries). The system also
The FCC process offers the refiner a reliable, long-run conforms to API Recommended Practice 554 (Process
operation; a wide array of products; a high-quality gaso- Instrumentation and Control).
line with a relatively high octane number; and a method Today’s safety standards recognize the benefit of fault-
for converting various feed stocks to gasoline. tolerant, redundant, programmable electronic systems.
The combination of high yield, high octane and low cost The protection layer model, recently recognized by the
makes the FCC process a key contributor to a refinery’s US and international standards agencies (including
overall gasoline production strategy. OSHA), maximizes the availability and reliability in the
interlock system design.
Application
Availability is a measure of a system’s success – the
The proper implementation of a robust interlock system system does what it needs to do, when it is asked to do
can assist the refiner with the automated shutdown of the it. The lack of availability means that a system may not
catalyst section of the FCC unit. This automation avoids trip when asked to trip, that is, failures can be hidden or
major equipment damage while placing the FCC unit in a unknown. Programmable Logic Controllers (PLCs) not
condition suitable for rapid re-start after an abnormal event. designed for safety / critical applications are susceptible
UOP provides a unique interlock system, integrating to high incidences of covert failures.
UOP expertise, the use of fault-tolerant, redundant,
Reliability, or percentage of on-stream time, is a measure
programmable electronic systems and process transmit-
of safe system effectiveness. A lack of reliability causes
ters (supplied by others) to automate the shutdown of
unnecessary trips.
the FCC unit.
Unnecessary trips cause downtime and lost profits!
Abnormal events
To achieve the reliability and availability levels desired,
Although the FCC process is a long running, low cost,
a system must use both fault-tolerant systems and
reliable process to operate, emergency situations may
multiple processors with self-diagnostics.
occur requiring the unit to be shutdown. These events
are referred to as abnormal events. Some of the more The UOP FCC EIS uses a TÜV-rated, fault-tolerant,
typical abnormal events are: triple-redundant, self-diagnostic safety PLC.
UOP FCC Emergency Interlock System 2
e-mail: [email protected]
fax: +1-847-391-2253
phone: +1-847-391-2000
UOP LLC
25 East Algonquin Road
© 2007 UOP LLC. All rights reserved.
Des Plaines, IL 60017-5017 The information in this document should not be construed as a representation for
which UOP assumes legal responsibility, or an authorization or recommendation
U.S.A. to practice a patented invention without a license.
www.uop.com UOP 4523-43 1107