0% found this document useful (0 votes)
70 views

C&D 12-100 DCS: Valve Regulated Lead Acid Battery y

This document provides specifications for a valve regulated lead acid battery designed for cyclic applications with an expected design life of 12 years. Key features include absorbent glass mat technology, a robust plate design for extended cycle life, and a computer generated grid design optimized for high power density. The battery is not restricted for transport by air, land, or sea and complies with relevant safety standards. It has 6 cells, a voltage of 12V, a capacity of 100Ah, and can operate in temperatures ranging from -40°F to 160°F with temperature compensation.

Uploaded by

Arrelinka
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
70 views

C&D 12-100 DCS: Valve Regulated Lead Acid Battery y

This document provides specifications for a valve regulated lead acid battery designed for cyclic applications with an expected design life of 12 years. Key features include absorbent glass mat technology, a robust plate design for extended cycle life, and a computer generated grid design optimized for high power density. The battery is not restricted for transport by air, land, or sea and complies with relevant safety standards. It has 6 cells, a voltage of 12V, a capacity of 100Ah, and can operate in temperatures ranging from -40°F to 160°F with temperature compensation.

Uploaded by

Arrelinka
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

DCS

C&D 12-100 DCS


Valve Regulated Lead Acid Battery
y
Design For Cycling Applications

APPLICATIONS FEATURES
z Cyclic Applications z Design life: 12 years z Absorbent Glass Mat (AGM) technology
Mobility Markets for efficient gas recombination of up to
z z Robust plate for exten
nded cycle life
99% and freedom from electrolyte
z Medical z Computer generated grid
g design maintenance
Elevator optimized for high pow
wer density
z z Not restricted for air transport -
z Electric Wheelchair z Low calcium g
grid alloy
y for reduced g
gas Complies
p with IATA/ICAO Special
p
emissions and ease ofo recycling Provision A67
z Electric Bikes
z Flame-arresting one-w way pressure- z Not restricted for surface transport –
relief vent for safety an
nd long life classified as non-hazardous material as
related to DOT-CFR Title 49 parts 171-
z UL-recognized compo
onent
189
z Multicell design for economy of
z Not restricted for water transport –
installation and mainteenance
classified as non-hazardous material
per IMDG Amendment 27

SPECIFICATIONS

Cells Voltage pacity


Cap IEC Short Circuit
Weight IEC Resistance
Per Unit Per Unit C20, 20hr rate
r @ 25℃ Current
6 12V 33.5
33 5 Kg
g 100
00
0 Ah 1490
90 A 6.5
6 5 ((mΩ)

*All dimensions in inch and (mm). All dimensions are for reference only. Contact a C&D Representative for compplete dimensional information.
Specifications
O
Operating
ti Temperature
T t Range
R with
ith temperature
t t Discharge
Di h e: -40°F
40°F (-40°C)
( 40°C) to
t +160°F (71°C)
compensation Charge: -1
10°F (-23°C) to +140°F (60°C)

Nominal Operating Temperature Range +68°F (2


20°C) to +95°F (35°C)

Float Charging Voltage 13.65 ± 0.15


0 VDC average per 12V unit (25°C)

Recommended Maximum Charging Current Limit C/5 amperres @ 8hr rate

Equalize charge and cycle service voltage 14.40 to 14.80 VDC average per 12V unit @ 77°F (25°C)

Self Discharge Battery caan be stored up to 4 months at 77°F (25°C) before a freshening charge
is required
d. Batteries stored at temperatures greater than 77°F (25°C) will require
recharge sooner
s than batteries stored at lower temperatures. See C&D brochure 41-
7272, Selff-Discharge and Inventory Control for details.

Accessory Inter unit connectors,


c racks and cabinet systems are optional.

Terminal: Insert term


minal to accept 1/4 -20 UNC bolt

Container and Cover Materials PP (UL94V


V-2)

Constant Current Discharge Table - Amps @ 25°C (77°F)


Operating Time to
o End Point Voltage
End Voltage
5min 10min 15min 30min 1hr 2
2hr 3hr 4hr 5hr 8hr 10hr 20hr
Per Cell
1.85 160.9 153.2 127.4 89 56.2 32
2.7 23.8 19 15.9 10.7 8.77 4.72
1.80 215.3 173.6 145.2 98 59.8 34
4.3 24.8 19.8 16.6 11.15 9.14 4.91
1.75 255 191 155.6 101.5 61.1 34
4.9 25.3 20.1 16.8 11.34 9.28 4.99
1.70 273 200 162 104 62 35
5.4 25.5 20.3 17 11.42 9.35 5.03
1.67 278 203 164.5 105 62.3 35
5.6 25.7 20.4 17 11.47 9.39 5.05
1.65 283 206 167 105.5 62.5 35
5.8 25.8 20.5 17.1 11.5 9.42 5.06

Constant Power Discharge Table - Watts Per Cell @ 25°C (77°F)


Operating Time to
t End Point Voltage
End Voltage
5min 10min 15min 30min 1hr 2
2hr 3hr 4hr 5hr 8hr 10hr 20hr
Per Cell
1.85 296.7 275.0 228.0 163.0 104.6 62.7
6 45.8 36.7 30.9 20.86 17.28 9.61
1.80 397.0 311.0 261.0 179.0 110.1 6
65.4 47.8 38.1 31.9 21.52 17.84 9.95
1.75 450.0 335.0 276.0 185.0 111.7 6
66.6 48.5 38.5 32.2 21.73 18.00 10.07
1.70 474.0 358.6 290.0 188.5 113.0 6
67.2 49.0 38.9 32.5 21.89 18.14 10.19
1.67 485.0 368.0 296.0 189.5 113.5 6
67.5 49.2 39.0 32.6 21.95 18.20 10.22
1.65 492.0 375.0 300.0 190.0 113.9 6
67.8 49.3 39.1 32.7 22.00 18.24 10.23

* All data shall be changed without prior notice, C&D reserves the right to explain and update the inforrmation contained hereinto.

Shanghai C&D Battery Co., Ltd.


No.55 Liandu Road, Spark Development Zone,
1400 Union Meeting Road Shanghai, P.R.C
P.O.Box 3053 • Blue Bell, PA 19422-0858
(215) 619-2700 • Fax (215) 619-7898 • (800) 543-8630 Service Hotline:400 - 678 - 3721

V 0113-DCS-E www.cdtechno.com.cn & www.cdtechno.com