0% found this document useful (0 votes)
154 views3 pages

Characteristics Value Description: Endress+Hauser Mon, 20 Jun 2016 Page 1 / 3

This document lists spare parts for an Endress+Hauser flow meter. It includes 7 items in the spare parts list, each with an order code, description, recommended stock level, position group, and validity. It also includes additional information on several of the listed spare parts, including characteristics and values, approval codes, materials, and compatible products.

Uploaded by

Ramon Garcia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
154 views3 pages

Characteristics Value Description: Endress+Hauser Mon, 20 Jun 2016 Page 1 / 3

This document lists spare parts for an Endress+Hauser flow meter. It includes 7 items in the spare parts list, each with an order code, description, recommended stock level, position group, and validity. It also includes additional information on several of the listed spare parts, including characteristics and values, approval codes, materials, and compatible products.

Uploaded by

Ramon Garcia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

List of spare parts

FMP51-BAECCDACC3AGJ+ADZ1

Order code

Characteristics Value Description


Approval: BA ATEX II 1G Ex ia IIC T6 Ga
Power Supply; Output: E 2-wire; FOUNDATION Fieldbus,,
switch output
Display, Operation: C SD02 4-line, push buttons +, data
backup function
Housing: C GT20 dual compartment, Alu, coated
Electrical Connection: D Thread NPT1/2, IP66/68
NEMA4X/6P
Probe: AC ..... mm, rod 12mm 316L
Seal: C3 FFKM Kalrez, -20...200oC/-
4...392oF,, saturated steam max
150oC/302oF
Process Connection: AGJ NPS 3" Cl.150 RF, 316/316L, flange
ASME B16.5
>Additional Operation Language: AD Spanish
>>Marking: Z1 Tagging (TAG), see additional spec.

Spare parts

Order code Description Rec. Tk Pos. Group Valid


71115175 Housing filter Brass/Ni GT19/20, 1 set S 19 Filter
Consists of:
2x filter plug brass nickel,
pressure compensation filter.
Usage: FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57.
Usage: Promass 200/TB2,
Prosonic Flow 200, Promag 200,
Prowirl 200.

71115176 Set housing securing clamps S 17 Housing


Usage: housing GT18/GT19/GT20, /housin
FMP50/51/52/53/54/55/56/57, g
FMR50/51/52/53/54/56/57. accesso
Usage: Promass 200/TB2, ries
Prosonic Flow 200, Promag 200,
Prowirl 200.

71110297 Cover GT20 Alu, sight glass, gasket S 20 Cover


Material: aluminium, coated.
O-ring EPDM, PTFE coated.
Usage: FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57.
Usage: Promass 200/TB2,
Prosonic Flow 200, Promag 200,
Prowirl 200.

71110301 Cover GT20 Alu, Terminal Ex, gasket S 25 Cover


Material: aluminium, coated.
O-ring EPDM, PTFE coated.
Usage: terminal compartment,
not for Ex d/XP,
FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57.
Usage: Promass 200/TB2,
Prosonic Flow 200, Promag 200,
Prowirl 200.

Endress+Hauser Mon, 20 Jun 2016 Page 1 / 3


List of spare parts
71110303 Sealing set housing GT18,GT19,GT20 S 65 Sealing
Consists of:
O-ring 88.5x3.53 EPDM/PTFE,
cover electronics compartment,
housing GT19.
O-Ring 88.5x3.53 NBR,
cover electronics compartment,
housing GT18, GT20.
O-ring 91.67x3.53 EPDM/PTFE,
cover terminal compartment,
housing GT19.
O-Ring 91.67x3.53 NBR,
cover terminal compartment,
housing GT18, GT20.
O-ring 50.39x3.53 EPDM/PTFE,
housing/sensor.
Usage: FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57.
Usage: Promass 200/TB2,
Prosonic Flow 200, Promag 200,
Prowirl 200.

XPF0001-X4+ADZ1 Elektronics Levelflex FMP5x + S 30 Electron


Main electronics. ic

71164940 I/O module, 2-wire, PA/FF, PFS, Ex, V2 + S 34 I/O


Non-Ex, Ex. module
PROFIBUS PA, FOUNDATION Fieldbus.
PFS=switch output.
Version 2.
Usage: FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57.
Usage: Promass 200, Prowirl 200,
Promag 200.

71110280 Terminal set 2-wire, I/O module + S 37 Termina


Consists of: ls
4x terminal 2-pole, green.
Usage: FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57.
Usage: Promass 200/TB2,
Prosonic Flow 200, Promag 200,
Prowirl 200.

XPD0024-AC00 Replacement for 71109658 + S 40 Display


Display module, SD02, push buttons
For housing: GT18, GT19, GT20.
Usage:
FMP50/51/52/53/54/55/56/57,
FMR50/51/52/53/54/56/57, FHX50.
Promass 200/TB2, Prosonic Flow 200,
t-mass 150, Promag 200, Prowirl 200.
Consists of:
Display SD02, helix cable,
ribbon cable, connector cover.

71206552 Cable FHX50, 5m S Uncate


Connection cable, shielded. gorised
Usage: FHX50.

XPF0005- Probe FMP51 w/o process connection S 55 Sensori


BAACC3AGJ+Z1 Usage: existing process connection c
FMP51.

71114464 O-ring 10.77x 2.62 , FFKM Kalrez, 1piece + S 57 Sealing


Usage: FMP51.

71162242 Weather prot. cover GT18/GT19/GT20, 316L A Uncate


Usage: FMP50/51/52/53/54/55/56/57, gorised
FMR50/51/52/53/54/56/57.
Usage: Promass 200/TB2,
Prosonic Flow 200, Promag 200, Prowirl
200.

XPF0001-X4+ADZ1

Endress+Hauser Mon, 20 Jun 2016 Page 2 / 3


List of spare parts

Characteristics Value Description


For Product: X FMP50/51/52/53/54/56/57
Output: 4 FOUNDATION Fieldbus
>Additional Operation Language: AD Spanish
>>Marking: Z1 TAG, on packing lable

XPD0024-AC00

Characteristics Value Description


For Product: A 5X2B**-; 6XAB**-; 7X2B**-; 8X2B**-, 9B2B**-,
FMP5X-; FMR5X-; FHX50-
Display; Operation: C SD02 4-line; push buttons + data backup function
Revision number: 00 Not used

XPF0005-BAACC3AGJ+Z1

Characteristics Value Description


Approval: BA ATEX II 1G Ex ia IIC T6 Ga
Probe: AC ..... mm, rod 12mm 316L
Seal: C3 FFKM Kalrez, -20...200oC/-4...392oF, saturated
steam max 150oC/302oF
For Process Connection: AGJ NPS 3" Cl.150 RF, 316/316L flange ASME B16.5
>>Marking: Z1 TAG, on packing lable

Endress+Hauser Mon, 20 Jun 2016 Page 3 / 3