CRVB-N/CRVT-N
5136979300 - CRVB/6-500 N (230V50/60HZ) N8 - ROOF MOUNTED FANS
Centrifugal roof fan in horizontal discharge format, centrifual backward cuved impeller.Steel finger proof guard.Base manufactured from galvanised sheet steel,
cowl from spun aluminium. External rotor motor IP54, F. S&P model CRVB/6-500 N (230V50/60HZ) N8 for an airflow 2.999 m³/h and static pressure 235 Pa.
Theoretical Working Point Performance Chart
Airflow 2.764 m³/h 0,5
Static Pressure 200 Pa
Temperature 20 °C 0,4
Altitude 0m
Input Power (kW)
Density 1,2 kg/m³ 0,3
Frequency 50 Hz
Voltage 1-230V-50Hz
0,2
Working Point
Airflow 2.999 m³/h 0,1
Static Pressure 235 Pa
Dynamic pressure 5,22 Pa
0,0
Total Pressure 241 Pa
350
Input power 0,436 kW
300
Outlet speed 2,9 m/s
Static Pressure (Pa)
Fan speed 890 rpm 250
Specific Fan Power 0,52 W/l/s 200
Construction 150
Discharge diameter 500 mm 100
Fan size 500
50
Weight 48,50 kg
0 100V 140V 180V 230V
Motor Characteristics 0 1000 2000 3000 4000 5000 6000 7000
Number of poles 6
Q- Airflow (m³/h)
Voltage 1-230V-50Hz
Maximum absorbed current 1,9 A
IP Rating IP54
Motor insulation class F Sound Performance
Drawing 63 125 250 500 1k 2k 4k 8k Overall
Inlet (LwA) 37 51 56 59 62 62 58 51 67
Inlet LpA @ 1,5m 22 36 41 44 47 47 43 36 53
Outlet (LwA) 43 58 57 64 69 67 61 54 73
Outlet LpA @ 1,5m 28 43 42 49 54 52 46 39 58
A B C D E F G
950 590 710 407 40 530 14
C/ Llevant, 4 08150 Parets del Vallès (Barcelona)- Tel. +34 93 571 93 00 - Fax. +34 93 571 93 01 [email protected] - www.solerpalau.es 1/10
9/18/2019, 8:59:51 AM
CRVB-N/CRVT-N
5136979300 - CRVB/6-500 N (230V50/60HZ) N8 - ROOF MOUNTED FANS
Performance Chart
0,5
0,4
0,3
Input Power (kW)
0,2
0,1
0,0
350
300
250
Static Pressure (Pa)
200
150
100
50
0 100V 140V 180V 230V
0 1000 2000 3000 4000 5000 6000 7000
Q- Airflow (m³/h)
C/ Llevant, 4 08150 Parets del Vallès (Barcelona)- Tel. +34 93 571 93 00 - Fax. +34 93 571 93 01 [email protected] - www.solerpalau.es 2/10
9/18/2019, 8:59:51 AM
CRVB-N/CRVT-N
5136979300 - CRVB/6-500 N (230V50/60HZ) N8 - ROOF MOUNTED FANS
Drawing
A B C D E F G
950 590 710 407 40 530 14
C/ Llevant, 4 08150 Parets del Vallès (Barcelona)- Tel. +34 93 571 93 00 - Fax. +34 93 571 93 01 [email protected] - www.solerpalau.es 3/10
9/18/2019, 8:59:51 AM
CRVB-N/CRVT-N
5136979300 - CRVB/6-500 N (230V50/60HZ) N8 - ROOF MOUNTED FANS
Accessories
5401620900 - CONTROL ECOWATT AC/4A (230Vac 50HZ)
Control element for demand controlled ventilation systems in public, commercial residential building it automatically modifies the fan speed to adapt it to the
needs defined in the system, measured with sensors. It has three basic modes of operation: 1. Integral proportional control at constant pressure. 2.
Proportional control with maximum demand criteria with multiple sensor input: temperature, CO2 and relative humidity. 3. Minimum-maximum control with
three-sensor input: CO2, temperature, relative humidity or presence detectors (PIR). DC signal output of 1 to 10 V or signal output for AC voltage variation
for single phase motors at 230 V. ECOWATT C CONTROL: for single phase ventilation units. ECOWATT C CONTROL: for DC ventilation units . Power supply:-
AC model: 1~230 V. - DC model: 1~230 V or 24 VDC..
Dimensions
B H T
165 220 110
5401652800 - CR-TEMP
Ambient temperature controller with an electronic sensor inside. Allows for manual or automatic control of ON/OFF switch with the following functions:-
Setpoint temperature- Weekly programming that can switch on and off twice a day- Detects open windows from quick drop in temperature- Manual
override. Includes an electronic sensor that reads room temperature.
5401643000 - CONTROL ETT-6
Electronic step controller. Can control activation of up to six devices. Can be used to switch on and off heating systems (EC wall-mounted fan heaters or
TERMOTECH radiant panels) or for ventilations systems with several units.
C/ Llevant, 4 08150 Parets del Vallès (Barcelona)- Tel. +34 93 571 93 00 - Fax. +34 93 571 93 01 [email protected] - www.solerpalau.es 4/10
9/18/2019, 8:59:51 AM
CRVB-N/CRVT-N
5136979300 - CRVB/6-500 N (230V50/60HZ) N8 - ROOF MOUNTED FANS
5401272900 - REB-2.5 N *230V 50*
Electronic speed controller
Dimensions
A B C
80 22 46
5401273700 - REB-2.5 N E *230V 50*
Electronic speed controller
5401246300 - RMB-3,5 (220V 50Y60)
AUTOTRANSFORMER SPEED CONTROLLER
Dimensions
A B C
230 180 95
C/ Llevant, 4 08150 Parets del Vallès (Barcelona)- Tel. +34 93 571 93 00 - Fax. +34 93 571 93 01 [email protected] - www.solerpalau.es 5/10
9/18/2019, 8:59:51 AM
CRVB-N/CRVT-N
5136979300 - CRVB/6-500 N (230V50/60HZ) N8 - ROOF MOUNTED FANS
5416722600 - BI-7
Support base for inclined curb mounted installations. To ensure a proper installation of the CRHB-CRHT roof fan it is essential to specify the roof pitch angle
(a) and the distance (d) between the roof beam profiles.
Dimensions
B C D
694 590 50
5136865200 - JAA-710
ACOUSTIC UPSTAND
Corrections Dimensions
63 125 250 500 1k 2k 4k 8k
A B C H G
-0 -2 -8 -14 -24 -28 -16 -11
875 695 590 1000 785
5138908400 - JAE-710 N
CIRCULAR FLEXIBLE COUPLING
Dimensions
D E H J
503 254 560 581
C/ Llevant, 4 08150 Parets del Vallès (Barcelona)- Tel. +34 93 571 93 00 - Fax. +34 93 571 93 01 [email protected] - www.solerpalau.es 6/10
9/18/2019, 8:59:51 AM
CRVB-N/CRVT-N
5136979300 - CRVB/6-500 N (230V50/60HZ) N8 - ROOF MOUNTED FANS
5138907600 - JBR-710 N
CIRCULAR DUCT FLANGE
Dimensions
D E H J
503 69 560 581
5136814000 - JBS-710
Flat roof up stand for mounting a roof fan on a flat roof without up stand.
Dimensions
A B C E G
875 694 590 300 785
5136885000 - JCA-710 N
BACK DRAFT SHUTTER
Dimensions
D E F H J
503 285 300 560 581
C/ Llevant, 4 08150 Parets del Vallès (Barcelona)- Tel. +34 93 571 93 00 - Fax. +34 93 571 93 01 [email protected] - www.solerpalau.es 7/10
9/18/2019, 8:59:51 AM
CRVB-N/CRVT-N
5136979300 - CRVB/6-500 N (230V50/60HZ) N8 - ROOF MOUNTED FANS
5136804100 - JMS-710
Sealing frame for mounting a roof fan on an up stand or base.
Dimensions
A B C E F
875 695 590 50 70
5136825600 - JPA-710
ADAPTER PLATE ACCESSORY TO BE USED WITH JCA,JBR & JAE ACCESSORIES
Dimensions
B C D H
694 590 503 560
C/ Llevant, 4 08150 Parets del Vallès (Barcelona)- Tel. +34 93 571 93 00 - Fax. +34 93 571 93 01 [email protected] - www.solerpalau.es 8/10
9/18/2019, 8:59:51 AM
CRVB-N/CRVT-N
5136979300 - CRVB/6-500 N (230V50/60HZ) N8 - ROOF MOUNTED FANS
Sound Performance
63 125 250 500 1k 2k 4k 8k Overall
Inlet (LwA) 37 51 56 59 62 62 58 51 67
Inlet LpA @ 1,5m 22 36 41 44 47 47 43 36 53
Outlet (LwA) 43 58 57 64 69 67 61 54 73
Outlet LpA @ 1,5m 28 43 42 49 54 52 46 39 58
C/ Llevant, 4 08150 Parets del Vallès (Barcelona)- Tel. +34 93 571 93 00 - Fax. +34 93 571 93 01 [email protected] - www.solerpalau.es 9/10
9/18/2019, 8:59:51 AM
CRVB-N/CRVT-N
5136979300 - CRVB/6-500 N (230V50/60HZ) N8 - ROOF MOUNTED FANS
ErP Data Warnings
Motor absorbed current may vary slightly depending on motor installed
Ecodesign
Commission regulation (EU) N°1253/2014 of July 2014
Information requirements (Annex V)
CRVB/6-500 N (230V50/60HZ)
Product description
N8
Manufacturer's Info S&P ES-08150 CIF-B64911928
Identifier -
Typology NRVU unidirectional
Drive VSD
Type of HRC None
Thermal efficiency (%) NA
Qnom (m3/s) 0,94
Pelec (kW) 0,44
SFPint (W/m3/s) NA
Face velocity (m/s) 2,18
Δps,ext (Pa) 211,18
Δps,int (Pa) NA
Δps,add (Pa) NA
Static efficiency fans (%) 48,6
External leakage rate (%) 0
Internal leakage rate (%) NA
Filter performance NA
Filter warning NA
LWA dB(A) 73
https://www.solerpalau.com/
C/ Llevant, 4 08150 Parets del Vallès (Barcelona)- Tel. +34 93 571 93 00 - Fax. +34 93 571 93 01 [email protected] - www.solerpalau.es 10/10
9/18/2019, 8:59:51 AM