0% found this document useful (0 votes)
173 views9 pages

A23

The document contains performance curve specifications for three HCP pump models. It provides information on frequency, discharge size, output power, head pressure, flow capacity, voltage specifications, rated current, pole/rpm settings, start method, insulation class, and graphs showing head pressure and efficiency curves versus flow capacity for each model.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
173 views9 pages

A23

The document contains performance curve specifications for three HCP pump models. It provides information on frequency, discharge size, output power, head pressure, flow capacity, voltage specifications, rated current, pole/rpm settings, start method, insulation class, and graphs showing head pressure and efficiency curves versus flow capacity for each model.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

HCP PUMP FILE NO.

PC-M-E5-A231
PUMP PERFORMANCE CURVES
A-23 DATE: 2011.1
MODEL
STANDARD SPECIFICATION REFERENCE SPECIFICATION
FREQUENCY 50 Hz
DISCHARGE 2 inch / 50 mm
OUTPUT 3 HP / 2.2 kW HP kW
HEAD 24.5 M
CAPACITY 0.2 m3/min
PHASE/VOLTAGE 1 f 220 V 230 V 240 V f V
RATED CURRENT 15.0 A 14.6 A 14.4 A A
POLE / R.P.M. 2 P / 2850 R.P.M.
START METHOD DIRECT
INSULATION CLASS B
REMARK

35 100

90
30
HEAD 80

25 70

60
20

EFF.
HEAD

EFF.
50
15
40 %
M
10 30

20
5
10

0 0
0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6

CAPACITY m3/min

3
OUTPUT

kW 0
0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6
CAPACITY m3/min

HCP PUMP MANUFACTURER CO.,LTD.


HCP PUMP FILE NO. PC-M-E5-A233
PUMP PERFORMANCE CURVES
A-23 DATE: 2011.1
MODEL
STANDARD SPECIFICATION REFERENCE SPECIFICATION
FREQUENCY 50 Hz
DISCHARGE 2 inch / 50 mm
OUTPUT 3 HP / 2.2 kW HP kW
HEAD 24.5 M
CAPACITY 0.2 m3/min
PHASE/VOLTAGE 3 f 230 V 380 V 400 V 415 V f V
RATED CURRENT 8.6 A 5.1 A 5.0 A 4.8 A A
POLE / R.P.M. 2 P / 2850 R.P.M.
START METHOD DIRECT
INSULATION CLASS B
REMARK

35 100

90
30
HEAD 80

25 70

60
20

EFF.
HEAD

EFF.
50
15
40 %
M
10 30

20
5
10

0 0
0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6

CAPACITY m3/min

3
OUTPUT

kW 0
0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6
CAPACITY m3/min

HCP PUMP MANUFACTURER CO.,LTD.


HCP PUMP FILE NO. PC-M-E6-A231
PUMP PERFORMANCE CURVES
A-23 DATE: 2011.1
MODEL
STANDARD SPECIFICATION REFERENCE SPECIFICATION
FREQUENCY 60 Hz
DISCHARGE 2 inch / 50 mm
OUTPUT 3 HP / 2.2 kW HP kW
HEAD 25 M
CAPACITY 0.2 m3/min
PHASE/VOLTAGE 1 f 220 V 230 V 240 V f V
RATED CURRENT 14.4 A 14.0 A 13.8 A A
POLE / R.P.M. 2 P / 3450 R.P.M.
START METHOD DIRECT
INSULATION CLASS B
REMARK

35 100

90
30
HEAD 80

25 70

60

EFF.
20
HEAD

EFF.
50
15 %
M 40

10 30

20
5
10

0 0
0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6
CAPACITY m3/min

3
OUTPUT

kW 0
0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6
CAPACITY m3/min

HCP PUMP MANUFACTURER CO.,LTD.


HCP PUMP FILE NO. PC-M-E6-A233
PUMP PERFORMANCE CURVES
A-23 DATE: 2011.1
MODEL
STANDARD SPECIFICATION REFERENCE SPECIFICATION
FREQUENCY 60 Hz
DISCHARGE 2 inch / 50 mm
OUTPUT 3 HP / 2.2 kW HP kW
HEAD 25 M
CAPACITY 0.2 m3/min
PHASE/VOLTAGE 3 f 220 V 230 V 380 V 440 V 460 V f V
RATED CURRENT 8.6 A 8.4 A 4.8 A 4.3 A 4.2 A A
POLE / R.P.M. 2 P / 3450 R.P.M.
START METHOD DIRECT
INSULATION CLASS B
REMARK

35 100

90
30
HEAD 80

25 70

60

EFF.
20
HEAD

EFF.
50
15 %
M 40

10 30

20
5
10

0 0
0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6
CAPACITY m3/min

3
OUTPUT

kW 0
0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6
CAPACITY m3/min

HCP PUMP MANUFACTURER CO.,LTD.


HCP PUMP FILE NO. PC-FT-E6-A231
PUMP PERFORMANCE CURVES
A-23 DATE: 2011.1
MODEL
STANDARD SPECIFICATION REFERENCE SPECIFICATION
FREQUENCY 60 Hz
DISCHARGE 2 inch / 50 mm
OUTPUT 3 HP / 2.2 kW HP kW
HEAD 82 ft
CAPACITY 52 GPM
PHASE/VOLTAGE 1 f 220 V 230 V 240 V f V
RATED CURRENT 14.4 A 14.0 A 13.8 A A
POLE / R.P.M. 2 P / 3450 R.P.M.
START METHOD DIRECT
INSULATION CLASS B
REMARK

110 100

100 90
HEAD
90 80
80
70
70
60

EFF.
HEAD

60 EFF.
50
50
40 %
ft 40
30
30

20 20

10 10

0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

CAPACITY GPM

3
OUTPUT

kW 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
CAPACITY GPM

HCP PUMP MANUFACTURER CO.,LTD.


HCP PUMP FILE NO. PC-FT-E6-A233
PUMP PERFORMANCE CURVES
A-23 DATE: 2011.1
MODEL
STANDARD SPECIFICATION REFERENCE SPECIFICATION
FREQUENCY 60 Hz
DISCHARGE 2 inch / 50 mm
OUTPUT 3 HP / 2.2 kW HP kW
HEAD 82 ft
CAPACITY 52 GPM
PHASE/VOLTAGE 3 f 220 V 230 V 380 V 440 V 460 V f V
RATED CURRENT 8.6 A 8.4 A 4.8 A 4.3 A 4.2 A A
POLE / R.P.M. 2 P / 3450 R.P.M.
START METHOD DIRECT
INSULATION CLASS B
REMARK

110 100

100 90
HEAD
90 80
80
70
70
60

EFF.
HEAD

60 EFF.
50
50
40 %
ft 40
30
30

20 20

10 10

0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

CAPACITY GPM

3
OUTPUT

kW 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
CAPACITY GPM