MOP of setup RET in SRAN 18SP
_________________________________________________________________________________________________
Table of Contents
1. EXECUTIVE SUMMARY……………………………………………………………………………………………… 4
2. BACKGROUND AND OBJECTIVES…………………………………………………………………………….… 5
3. SCOPE OF WORK………………………………………………………………………………………………………. 7
4. DETAIL TIME AND TABEL OVERALL ACTIVITY……………………………………………………………. 10
5. SERVICE AND AREA IMPACT…………………………………………………………………………………….. 11
6. TESTING AND VERIFICATION……………………………………………………………………………………. 12
7. ROLLBACK OPERATION…………………………………………………………………………………………….. 13
8. PERSON IN CHARGE…………………………………………………………………………………………………. 14
9. SUPPORTING DOCUMENT………………………………………………………………………………………… 15
3
MOP of setup RET in SRAN 18SP
_________________________________________________________________________________________________
1. EXECUTIVE SUMMARY
Involved NE:
Pre-requisite:
1. Combi/Comba_Tripleband
Default setting:
Electrical = 2 degree
Mechanical = 2 degree
Min degree = 0 degree
Max degree = 10 degree
2. Mobi_Pentaband
Default setting:
Electrical = 2 degree
Mechanical = 2 degree
Min degree = 0 degree
Max degree = 10 degree
4
MOP of setup RET in SRAN 18SP
_________________________________________________________________________________________________
5
MOP of setup RET in SRAN 18SP
Instructions on how to setup RET band 900, motor RET is R1 using BTS Manager, based on information table
RET Location Remarks RET ID RETU Naming : ALD ID RF Module type Antenna Line Number
served antenna line Antenna line
device
00CB1820000424- Sector-1 RET - 1 RETU - 1 ALD - 1 FXDA, FXDB RMOD - 1 : ANT1 … ANT6 | RMOD - 2 : ANT7
R1 … ANT12
1. Go to commissioning wizard
2. Please see setting gear for R1, than Click. Than take look in setting Antenna Line Device Antenna Line Device RET
MOP of setup RET in SRAN 18SP
_________________________________________________________________________________________________
click
3. Major setting in band 900 for RET-1 must be setup is : control protocol, controlling port, and DC power source
Control protocol = AISG 2.0 _for protocol antenna line device R1 for band 900
Auto-detect
Controlling port = RMOD_1/ANTL_1 (FXDA) or (FXDB) _ make sure physical port antenna (+45) connected to port ANT_1 (TxRx)
7
MOP of setup RET in SRAN 18SP
_________________________________________________________________________________________________
OSS will remotly send degree of electrical tilt_signal go to port (+45) in antenna, make sure jumper connection from ANT_1 (TxRx) at RF
module FXDA or FXDB are correct and properly
DC power source = RMOD_1/ANTL_1 (FXDA) or (FXDB) _ make sure physical port antenna (+45) connected to port ANT_1
Motor RET running using power dc feed/source from antenna port (+45), make sure jumper connection from ANT_1 (TxRx) at RF module
FXDA or FXDB are correct and properly
8
MOP of setup RET in SRAN 18SP
_________________________________________________________________________________________________
Instructions on how to setup RETU band 900 (R1), for served antenna line ANT_1, ANT_3, ANT_5 of FXDB_1/FXDA_1 and served antenna line
ANT_7, ANT_9, ANT
1. Major setting in RETU for RET-1 must be setup is : served antenna lines, Base station ID, Sector ID, Angel
Served antenna lines, for define antenna connection band 900 in part RF module (FXDA or FXDB) sides
The More antenna lines number is described number of RF module (FXDA or FXDB) installed in the site BTS.
In this capture means: RMOD-1/ANTL-1 (FXDA number-1) while RMOD-2/ANTL-7 (FXDA number-2) is correspondent with band 900
RETU-R1.
9
MOP of setup RET in SRAN 18SP
_________________________________________________________________________________________________
Site name
Sector ID : 1-900 (sector 1), or 2-900 (sector 2), or 3-900 (sector 3) _ for this identification must follow Standard Naming RET Indosat.
Please see supporting document for more details
The sector ID must have corelation with serial number antenna, the input parameter in site ID must correct with actual antenna
insalled is in the right sector, to cross check by validating serial number antenna.
Sector ID
Angels: is consisting of degree value refer to RF data planning and antenna tilt range capability as of antenna specification
10
MOP of setup RET in SRAN 18SP
_________________________________________________________________________________________________
Angle = electrical tilt degree value as per RF data planning, range value : 0 – 90 degree. Default electrical tilt 2 degree
Mechanical angle = is value set of mechanical tilt bracket antenna as of actual install. Default mechanical tile 0 degree
Min – Max Angle = is range electrical tilt capability antenna as of specification. value of range electrical tilt between 0 – 10 degrees
For the other RET unit : Y1, Y2_band 1800, 2100 or Y3, Y4 (antenna pentaband) is the same procedure as described in RET unit R1
Antenna model Antenna serial number Site ID Basestarion ID Sector ID RET Location Remarks
Combi/comba 00CB1820000424 16SBS005 PEMANGKAT 1-900 00CB1820012820-R1 Sector-1
RET IDCombi/combaRETU Naming :
00CB1820000424 ALD ID16SBS005 RF Module type
PEMANGKAT 1-1800 Antenna
00CB1820012820-Y1 Line NumberSector-1
served antenna line Antenna line device
Combi/comba 00CB1820000424 16SBS005 PEMANGKAT 1-2100 00CB1820012820-Y2 Sector-1
RET - 1 RETU - 1 ALD - 1 FXDA, FXDB RMOD - 1 : ANT1 … ANT6 | RMOD - 2 : ANT7 … ANT12
Combi/comba 00CB1820000325 16SBS005 PEMANGKAT 2-900 00CB1820000325-R1 Sector-2
RET - 2 RETU - 2 ALD - 1 FXDE RMOD - 1 : ANT1 … ANT6 | RMOD - 2 : ANT7 … ANT12
Combi/comba 00CB1820000325 16SBS005 PEMANGKAT 2-1800 00CB1820000325-Y1 Sector-2
RET - 3 RETU - 3 ALD - 1 FRGP, FRGF, FRGU RMOD - 1 : ANT1 … ANT6 | RMOD - 2 : ANT7 … ANT12
Combi/comba
RET - 4 RETU - 400CB1820000325 ALD - 216SBS005 PEMANGKAT
FXDA, FXDB 2-2100 RMOD 00CB1820000325-Y2
- 1 : ANT1 … ANT6 | RMOD - 2Sector-2
: ANT7 … ANT12
Combi/comba
RET - 5 RETU - 500CB1820000400 ALD - 216SBS005 PEMANGKAT
FXDE 3-900 RMOD 00CB1820000400-R1
- 1 : ANT1 … ANT6 | RMOD - 2Sector-3
: ANT7 … ANT12
Combi/comba
RET - 6 RETU - 600CB1820000400 ALD - 216SBS005 PEMANGKAT
FRGP, FRGF, FRGU 3-1800 RMOD 00CB1820000400-Y1
- 1 : ANT1 … ANT6 | RMOD - 2Sector-3
: ANT7 … ANT12
RET - Combi/comba
7 RETU - 700CB1820000400 ALD - 316SBS005 PEMANGKAT
FXDA, FXDB 3-2100 RMOD 00CB1820000400-Y2
- 1 : ANT1 … ANT6 | RMOD - 2Sector-3
: ANT7 … ANT12
RET - 8 RETU - 8 ALD - 3 FXDE RMOD - 1 : ANT1 … ANT6 | RMOD - 2 : ANT7 … ANT12
RET - 9 RETU - 9 ALD - 3 FRGP, FRGF, FRGU RMOD - 1 : ANT1 … ANT6 | RMOD - 2 : ANT7 … ANT12
11
MOP of setup RET in SRAN 18SP
_________________________________________________________________________________________________
12
MOP of setup RET in SRAN 18SP
3. SUPPORTING DOCUMENTS