Kaito-Matic CAN Operating Instructions
Kaito-Matic CAN Operating Instructions
1. Table of Contents………………………………………………………………4
1.1 General Information…………………………………………………………4
1.2 Packaging and storage……………………………………………………....6
2. Product description…………………………………………………………...11
3. System summary………………………………………………………... 12SYS
4. The digital controller…………………………………………………………14
4.1 Description of the digital controller………………………………………..14
4.1.1 LCD ............................................................................................................ 14
4.1.3 Indicator light……………………………………………… …………17
4.14 Keys……………………………………………………………………18
4.1.5 Assembly………………………………………………………………18
4.2 Switch on test………………………………………………………………19
4.3 Sensor identificatio.................................................................................…..19
4.4 Operator Menu……………………………………………………………..18
4.4.1 Sensitivity setting………………………………………………...……21
4.4.2 Control window setting……………………….……………………….25
4.4.3 Unit of distance setting..........................................................................27
4.5 Different user setting………………………………………………………28
9. Maintenance…………………………………………………………………..59
9.1 General information………………………………………………………..59
9.2 How to clean the unit………………………………………………………59
10. Technical data……………………………..…………………………………61
11. The company profile……..………………………………………………….65
3
http://www.sz-kaito.com
E-mail: [email protected]
1.Table of Contents
1.1General Information
4
1. Summarize
Once receipt the goods and the packaging should be checked for damage.
Basic configuration
meter)
meters)
(yellow)
6
1. Summarize
Safety measures:
Mountings
Please adopt original Kaito cables. Please do not opening plug and
socket, avoiding destroy it moistureproof function. The screw joint
Need to tighten. Specific equipment installation in this operation
manual detailing corresponding part.
Wiring:
7
http://www.sz-kaito.com
E-mail: [email protected]
This equipment has been designed for industrial use and has been tested
accordingly. However, microprocessor technology puts certain demands
on the installation. We would therefore like to point out the following
things about an installation that, if not taken into account, can lead
later to disturbances during operation.
Supply voltages may not exceed, or fall short of, the specified values;
Connnect screened cables to earth at one end only (the equipment end);
Do not supply other equipment directly from the supply terminals of this
equipment;
Maximum Voltages:
Do not exceed the maximum allowed voltages. The maximum voltage between
8
1. Summarize
any two isolated circuits, or between one circuit and earth, is, if
not otherwise noted, limited to the highest value of the corresponding
input voltage or the corresponding supply voltage. The connecting
terminals or plug must be equipped with a fuse.
Fuses:
Configuration:
Alarm device:
Clearance of faults:
Before starting to clear faults make sure that every voltage supply
to the equipment has been removed. Faulty equipment should be examined
in an area suitably set up out for test purposes. Every attempt to
correct a fault in equipment that is still installed can be dangerous
for personnel and for the system. Before you remove or exchange sensors
in the system, make sure that the supply voltages have been removed.
10
2.Production description
2. Product description
11
http://www.sz-kaito.com
E-mail: [email protected]
3. System summary
12
3.System summary
Case-MOBA-matic 01.03.42.K80100981
13
http://www.sz-kaito.com
E-mail: [email protected]
4.Digital Controller
The controller can be used for most current machine types.The controllr
has a digital display, a LED display and four function lamps as well
as push buttons to operate it.
14
4. The Digital Controller
The LED's are only used to make the status of the valve outputs more
appearant to the user.Their representation is an increased and more
detaild display of the function of the arrow symbols on the LC display.。
Large
Output UP is
control
constantly on
Symbol Arrow constantly deviation
constantly on on
Medium Output UP is
control pulsing with big
Symbol
deviation pulse width
Arrows flashes
flashes
Small Output UP is
control pulsing with
deviation small pulse width
Symbol flash Center/on flash
15
http://www.sz-kaito.com
E-mail: [email protected]
No control No output
deviation activated
No Symbol
Center on
activated
Large
Output DOWN is
control
constantly on
Symbol Arrow deviation
constantly on constantly on
4.1.3 Functionlamps
Automatic lamp
String line
with Sonic-Ski with Big-Ski
lamp
You can change the value indicated on the display in both manual-
or automatic mode by pressing the UP- or DOWN button and the
ENTER-key simultaneously. This process has no effect on the control
18
4. The Digital Controller
Note: if you replace a sensor or remove the sensor, the controller will
be noted in the following information.At this point, the system
operator instructions, another electrical system operators is
necessary after all Settings, check out the new sensor system,
19
http://www.sz-kaito.com
E-mail: [email protected]
automatically confirmed.
In the controller's operator menu, you will find all parameters and
setting that are important for the control system in general and for
the use of the various sensors.
20
4. The Digital Controller
The operator menu can be accessed from the working menu only.
Activatethe
Activate thefirst
firstparameter
parameteritem
itembybypressing
pressingthe
the
A/Mbutton and the SET-button simultaneously.
A/Mbutton and the SET-button simultaneously. Use this
Use this
button button combination
combination to switch
to switch from from one
one parameter to the
parameter to the next.
next.
21
http://www.sz-kaito.com
E-mail: [email protected]
22
4. The Digital Controller
(standard setting to
„6“). „7“).
by a specialist.
Sensitiv Sensitiv
Deadband Propband Deadband Propband
ity ity
db(mm) Pb(mm) db(mm) Pb(%)
SE SE
1.0 2.2 46.0 1.0 0.18 2.10
2.0 2.0 41.0 2.0 0.16 1.90
3.0 1.8 36.0 3.0 0.14 1.70
4.0 1.6 31.0 4.0 0.12 1.50
5.0 1.4 26.0 5.0 0.10 1.30
6.0 1.2 21.0 6.0 0.08 1.10
7.0 1.0 16.0 7.0 0.06 0.90
8.0 0.8 11.0 8.0 0.04 0.70
9.0 0.6 6.0 9.0 0.02 0.50
10.0 0.4 1.0 10.0 0.00 0.30
For all grade sensors for Digi-Slope sensor
Sensitivity tables for ON/OFF valves:
Sensitivity Deadband Propband Sensitivity Deadband Propband
SE db(mm) Pb(mm) SE db(mm) Pb(mm)
1 5.0 18.0 1 4.0 18.0
2 4.0 16.0 2 3.4 16.0
3 3.6 14.0 3 3.0 14.0
4 3.4 12.0 4 2.4 12.0
5 3.0 10.0 5 2.0 10.0
6 2.4 8.0 6 1.4 8.0
7 2.0 6.0 7 1.0 6.0
8 1.6 5.0 8 0.8 5.0
9 1.2 4.0 9 0.6 4.0
10 1.0 3.0 10 0.4 3.0
25
http://www.sz-kaito.com
E-mail: [email protected]
This menu point only appears if a grade sensor has been chosen as active
sensor at the menu point “Sensor selection”, because it only has effect
on this type of sensor.
If a control deviation appears that is bigger than the set range this
control deviation will be recognized as a fault.
The display will show the symbol for the control window, both direction
arrows of the LC display and the complete LED arrow flash and the drive
of the hydraulic cylinders will be switched off.
The input is done in 0.1 cm, 0,1 inch or 0,01 feet steps, depending
on which physical unit for the distance measurements was set (see also
the next section "Unit of distance setting" of this operating
instructions).
26
4. The Digital Controller
27
http://www.sz-kaito.com
E-mail: [email protected]
This menu point only appears if a grade sensor has been chosen as active
sensor at the menu point “Sensor selection”, because it only has effect
on this type of sensor.
Here, the operator can preset the desired measuring unit for the
displayed distance values. You can choose between the physical
units ”centimeter“, ”inch“ and “feet“.
Return to
Press the
working mode by
... until the
A/M-button and the You can change pressing the
display alternates
SET-button several from one
between the sign A/M-button. If
times physical
„CAL“ for unit of no button is
measuring unit
simultaneously ... distance setting
to another by pressed for
and the measuring
pressing the about 5 sec.
unit that was
UP- or the DOWN the controller
entered last
button (here: switches back
(standard „CEn“ =
setting to the
centimeter automatically.
unit „Inch“).
28
4. The Digital Controller
STANDARD:
29
http://www.sz-kaito.com
E-mail: [email protected]
30
5. The Sonic-Ski sensor
5.1 Description
Sensor identification::
The Sonic-Ski can be mounted easily andquickly using simple tools. For
this purpose, a fastening tube should be
fitted at a suitable position (paver: on the
tow arm; milling machine: on the frame).
Procedure:
31
http://www.sz-kaito.com
E-mail: [email protected]
tube.
2. Insert the center pivot of the sensor into the mounting tube.
Direction of travel:
33
http://www.sz-kaito.com
E-mail: [email protected]
It is assumed that the Sonic-Ski and the digital controller are mounted,
the cables are connected and the digital controller has its voltage
supply. After the switch-on message, the digital controller indicates
the type of sensor. As soon as this message disappears automatically,
the system is ready for work. If the sensor is used for the first time
or has been changed, the sensor identification must be acknowledged
by pressing any one of the push buttons. If necessary, select this
sensor as described insection 4.
34
5. The Sonic-Ski sensor
35
http://www.sz-kaito.com
E-mail: [email protected]
1 2 3 4
ca.35com
string line
36
5. The Sonic-Ski sensor
5 6a 6b 7
37
http://www.sz-kaito.com
E-mail: [email protected]
8 9
Adjustment and
In order to be able You can switch back indication of the
to make corrections, to manual mode set point differ
the set point can be anytime with the according to the
changed in the A/M-button.The selected operation
automatic mode using automatic control mode (see also
the of the valves will section 4.4
UP/DOWN-buttons. then be switched Different user
off.。 settings“).)
38
5. The Sonic-Ski sensor
1 2 3 4
ca.35cm
For zero
Ground
setting, bring
Switch to the the tool into
manual mode working Position the
using the The ground mode position using
Sonic-Ski 35 cm
A/Mbutton. is activated by the
The function pressing the UP/DOWN-button above the
lamp "AUTO" UP/DOWN-buttons s at the
is off. ground
simultaneously. controller or
The string line the operating (measured
lamp is off. unit at the
value
machine.
indication has
to be
constantly
on).
39
http://www.sz-kaito.com
E-mail: [email protected]
5 6a 6b 7
direction
arrows are
without any Switch to the
40
5. The Sonic-Ski sensor
8 9
Sensitivity
Control window
The control window is active in both operating modes (string line- and
ground sensing). The setting of the control window is described in
section 4.4.2 of these operating instructions.
41
7.Mounting instructions of Balance beam
6.1 Description
There has exceptional case as follow, only adopting two sensors at the
front and back, and averaging the detection value of the two sensors.
Sensor identification:
42
http://www.sz-kaito.com
E-mail: [email protected]
43
7.Mounting instructions of Balance beam
6.2 Function pattern
Not only the single sonic-ski has the function of removing deviation
through averaging detection value, Non-contact balance beam(three
sensors) also has this function.
After averaging the detection value, it still has deviation, then the
deviation will be removed by “control range” function.
6.3 Mounting
44
http://www.sz-kaito.com
E-mail: [email protected]
Procedure:
45
7.Mounting instructions of Balance beam
二、Mounting rack
1.Front-inside support
46
http://www.sz-kaito.com
E-mail: [email protected]
2. Front-outside support
47
7.Mounting instructions of Balance beam
48
http://www.sz-kaito.com
E-mail: [email protected]
49
7.Mounting instructions of Balance beam
1. Install the left and right beam sonic-ski, front and rear one
around the leveling sensor mark, the middle one between the left
and right middle is ok ,attention the sonic underground 20cm no
other goods.
50
http://www.sz-kaito.com
E-mail: [email protected]
51
7.Mounting instructions of Balance beam
52
http://www.sz-kaito.com
E-mail: [email protected]
It is assumed that the Big-Ski and the digital controller are mounted,
that all cables are connected and the digital controller has its
voltage supply. After the switch-on message, the digital controller
indicates the sensor identification. As soon as the message disappears,
the system will be operable. If the Big-Ski is being used for the first
time or the sensor combination has been changed, the sensor
identification has to be acknowledged by pressing any one of the push
buttons. If necessary,select a sensor as described in section 4.
1 2
53
7.Mounting instructions of Balance beam
at the front and at the averaging of 3
back). sensors).
54
http://www.sz-kaito.com
E-mail: [email protected]
1 2 3
For zero
ca.35cm
setting, bring
Press the A/M Ground
the tool into
button,switch to
Position all
working
the
Sonic-Skis
position using
manual mode.
at a distance of
the
“AUTO”light on.
35cm
UP/DOWN-buttons
(13.75”)above
at
the ground.
the controller
or the
operating unit
at the
machine.
55
7.Mounting instructions of Balance beam
4 5 6 7
>1.5s
If the
with the
SET-button is
pressed for A/M-button.
more than The
1,5 seconds, The automatic
the controller
control
display changes keeps
from
"SEt" to "0.0" the tool at of the valves
and the the adjusted will then
measured value
and value.
be switched
the set point
are both off.
set to zero.
56
http://www.sz-kaito.com
E-mail: [email protected]
Sensitivity
If the control is too sluggish or too active in the automatic mode,
the sensitivity should be changed accordingly (see section 4.4.1 of
these operating instructions).
Control window
The control window is active when the digital controller is operated
with the Big-Ski.The setting of the control window is described in
section 4.4.2 of these operating instructions.
57
http://www.sz-kaito.com
E-mail: [email protected]
8. Trouble shooting
8.1 Summarize
In most cases, seriously, timely maintenance can avoid some error. This
can save a lot of time and unnecessary spending.
safety precautions:
58
8. Trouble shooting
The controller
fault display fault analysis solutions
output
Connect the
sensor.
Check the
No
Automatic mode, connection
identification
no/SEn the controller cable,If
to the sensor
have no output. necessary,
controller.
replace the
cable/
the sensor.
Sensor
SLo/out Check the
detection Automatic mode,
rtY/out sensor
value exceeds the controller
Las/out settings.
-23/out the allowable have no output.
Change sensors.
range.
Value exceeds Check the
the preset Automatic mode, sensor
controller the controller settings.
"detection have no output. Re-adjust the
range." sensor.
Check the
The controller connection
Automatic mode,
rop/dEF detects the cables, if
the controller
Slo/dEF failure necessary,
have no output.
sensor. replace the
cable/ sensor.
59
http://www.sz-kaito.com
E-mail: [email protected]
60
9.Maintenance
9. Maintenance
9.1 summarize
Gently wipe the surface of the device and a display with a rag.
61
http://www.sz-kaito.com
E-mail: [email protected]
This manual has been mentioned in front of the user can apply a
combination of their own control systems. That is say, the client maybe
have been some of the devices, which may not have access to some
equipment.
62
10. Technical data
Size: IP 67
Weight:
About 2.2 ㎏
Pin Definition:
driver interface:
12 cores bayonet socket
A= Shielded input
B=CAN-
Technical Data:
C=CAN+
Power Range:
D= Select the input loop around
10V-30V
E= Portrait / landscape
Current consumption: switching input
About 300mA(No-load) F= Alarm output
Allowable voltage fluctuation: G= No connection
+/-10% H= No connection
Output form: J= Down Output
Switch / proportional output, K= up Output
NPN, Maximum current 3A
L= Power +
Switch / proportional output,
M= Power -
PNP, Maximum current 2.5A
CAN Interface Protocol:
ISO 11898-24V
125kBit/sec
Operating Temperature Range:
Sensor Interface:
-10°C~+70°C
7 pin socket bayonet:
Storage temperature range:
A= Power supply +
-25°C~+85°C
B=CAN+
Protection class:
C= Power supply -
63
http://www.sz-kaito.com
E-mail: [email protected]
D=CAN-
E= Around the circuit selection
F= No connection
G= Shield
64
10. Technical data
Shielded input:
Size:
Technical Data:
Power Range:
11V~30V(DC) Sensor Interface:
Current consumption: (CAN Interface)
Maximum 300mA
Allowable voltage fluctuation: ISO11898-24V-125kBit/sec
+/-10% 7 pin socket bayonet:
Detection range:
20cm – 100cm A= Power supply +
Tightness: B=CAN+
+/-1mm
Operating Temperature Range: C= Power supply -
-10℃~+70℃ D=CAN-
Storage temperature range:
-25℃~+80℃ E= Around the circuit selection
Protection class: F= Installation location
IP67
Weight: G= Shield
About 2.2Kgs
66
11.Company Profile
67
http://www.sz-kaito.com
E-mail: [email protected]
ADD:No.4,ZhengHe Zhong
Road,TaiCang City,China
Zip:215412
Tel:+86-0512-81601001
81601990
81601991
81601993
81601981
Reception Tel:
+86-0512-81601995
Fax:+86-0512-53373883
Http:// www.sz-kaito.com
E-mail: [email protected]
Version:14-8-20
68