0% found this document useful (0 votes)
706 views1 page

P04 - General Arrangement Drawings.

The document provides notes and specifications for a skid-mounted corrosion inhibitor system. The key details are: 1. The skid will support a 1500 liter tank, piping, and other equipment. 2. All components will be heat traced, insulated, and painted according to project standards. 3. The tank will have a manway opening and discharge connection that will be confirmed at the detailed engineering stage.

Uploaded by

bmanojkumar16
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
706 views1 page

P04 - General Arrangement Drawings.

The document provides notes and specifications for a skid-mounted corrosion inhibitor system. The key details are: 1. The skid will support a 1500 liter tank, piping, and other equipment. 2. All components will be heat traced, insulated, and painted according to project standards. 3. The tank will have a manway opening and discharge connection that will be confirmed at the detailed engineering stage.

Uploaded by

bmanojkumar16
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Notes:

3195 1. Skid Shall be provided with Roofing Sheets


(not Show here for Clear Viewing of the Skid)
2. Interconnecting Pipeline shall be as per
3170 P&ID
3. Discharge Tie in connection- 3/4" x 150#
RF, Tie in Dimensions will be confirmed during
detail Engg stage.
4. All Piping, Tanks Shall be heat traced &
Insulated as per Project Specifications
5. Skid Structural Shall be painted as per TCO
Coating System.
1600
1500

6. Tank Nozzles shall confirm to P&ID.


Skid Roofing
7. Tank shall be provided with Man-way of 600
mm Which shall be Non standard Fabricated
design.
8. Skid shall be provded with Drip tray
Designed for Tank Volume.
9 Skid shall be provided with 4 point Lifiting.
10. Skid shall have 4 Point Foundation Holes
Suitable for Mounting of the Skid.

TOP - VIEW

1560

Discharge
Dampeners 0 24.08.2019 ISSUED FOR APPROVAL HEM PSK GR
REV DATE DESCRIPTION DRN CHK APP
REVISIONS
CLIENT :
Tank-1500 Liters 3/4" x 900# RF- Discharge Tie In
TENGIZCHEVROIL
2200
2360
2300

PROJECT:
IOR KOROLEV LARGE SCALE PILOT
2860

PROJECT

TITLE:

CORROSION INHIBITOR GA DRAWING


SCALE = NTS DATE 24.08.2019 24.08.2019 24.08.2019
DRAWING/DOCUMENT NAME
490
500

DRIPTRAY- 1500 Liters (Tank Volume) FORMAT HEMNATH SAMPATH RAJAN


A0 A1 A2 A3 A4
SIDE - VIEW DRAWING No.
SIGN DRAWN CHECKED
SHEET
APPROVED
REVISION

FRONT - VIEW SHEET 1 OF 1