COLUMN
AVAILABLE DATA:
fck = 30 N/mm2
fy = 415 N/mm2
SIZE OF FOOTING
W1 = 10/100 x 4000
= 400 KN
= 4400 / 200
= 22 m2
B x L = 22 m2
B x (B) = 22 m2
B2 = 22
= √22 = 4.7
= 271.61 KN/m2
PROJECTION OF FOOTING
FACTORED MOMENT
= 2489.7 x 106
𝑀𝑢𝑚𝑎𝑥
dreq = √
𝑄𝑢 𝑥 𝑏
2489.7 𝑥 106
dreq=√ = 357.7 Say 360
4.14 𝑥 4.7
d = 720 mm
D = 720 + 50
D = 770 mm
TENSION REINFORCEMENT
2489.7 x 106 = 0.87 x 415 x Ast x 720 (1- 415 x Ast / 30 x 4700 x 720)
Astmin = 0.12/100 x (b x D)
Ld = 1203.5 mm
Hence ok
TRANSVERSE SHEAR
= 1602.10 KN
τv = 0.47 N/mm2
= 0.12%
τc = 0.29 N/mm2
= 1470 x 1470 mm
Vz = 5412.94 x 103 N
τz = 1.27 N/mm2
τcz = Ksτcz
τz < Ksτcz
Hence ok
= (750 + 4 x 720)
= 3630 x 3630
= 0.45 x 30 x 2= 27 N/mm2
𝑃𝑢 4000 𝑥 1.5
Actual bearing stress= =
𝐴𝑟𝑒𝑎 𝑜𝑓 𝑐𝑜𝑙𝑢𝑚𝑛 0.75 𝑥0.75
= 10.67 N/mm2
10.67 < 27
Hence safe
Hence safe