This document is a manufacturer's data report for a pressure vessel built according to the ASME Boiler and Pressure Vessel Code Section VIII Division 1. It provides details on the vessel including that it was manufactured in Saudi Arabia, is a horizontal vessel, has a 590mm ID carbon steel shell 1 meter in length, SA-105 steel heads, no jacket, a maximum allowable working pressure of 1200 kPa, and was hydrostatically tested at 1560 kPa.

Uploaded by

arif99pak
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
109 views

Asme U1

This document is a manufacturer's data report for a pressure vessel built according to the ASME Boiler and Pressure Vessel Code Section VIII Division 1. It provides details on the vessel including that it was manufactured in Saudi Arabia, is a horizontal vessel, has a 590mm ID carbon steel shell 1 meter in length, SA-105 steel heads, no jacket, a maximum allowable working pressure of 1200 kPa, and was hydrostatically tested at 1560 kPa.

Uploaded by

arif99pak
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Mfg.

Representative: Date: Page __1___ of __3___


Authorized Inspector: Date:
FORM U-1 MANUFACTURER'S DATA REPORT FOR PRESSURE VESSELS
As Required by the Provisions of the ASME Boiler and Pressure Vessel Code Rules, Section VIII, Division 1
___________________________________________________________________________________________________________

1. Manufactured and certified by ______ SAUDI ARABIA_______


l(Name and address of Manufacturer)
2. Manufactured for ____________________________Demo Vessel_____________________________
l(Name and address of Purchaser)
3. Location of installation ___________________________________DEMO VESSEL____________________________________
l(Name and address)
4. Type ___________Horizontal___________ ____________Vessel_____________ ______________________
l(Horizontal, vertical, or sphere) l(Tank, separator, jkt. vessel, heat exch., etc.) l(Manufacturer's serial number)
___________N/A___________ _____ ___________N/A___________ __________2019___________
l(CRN) l(Drawing number) l(National Board number) l(Year built)
5. ASME Code, Section VIII, Div. 1 ______2017 Edition_______ __________________ _______________________
l[Edition and Addenda, if applicable (date)] l(Code Case number) l[Special Service per UG-120(d)]
Items 6-11 incl. to be completed for single wall vessels, jackets of jacketed vessels, shell of heat exchangers, or chamber of
multichamber vessels.

6. Shell: (a) Number of course(s) __________1___________ (b) Overall length _________1,0 mm _________
Course(s) Material Thickness Long. Joint (Cat. A) Circum. Joint (Cat. A, B, & C) Heat Treatment
Full, Spot, Full, Spot,
No. Diameter Length Spec./Grade or Type Nom. Corr. Type Eff. Type Eff. Temp. Time
None None
1 590 mm ID 1,00 mm SA-516 70 10 mm 2.5 mm 1 Full 100% 1 Full 100% None None
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Body Flanges on Shells


Bolting
Min Hub How Bolting Washer Washer
No. Type ID OD Flange Thk Thk Material Attached Location Num & Size Material (OD, ID, thk) Material
SA-193
1 WN 590 mm 812.8 mm 90 mm 10 mm SA-105 N Welded Shell 20 - 1-1/4" - -
B7N
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

7. Heads: (a) _____________SA-105 (H.T - N/A)______________ (b) ___________SA-234 WPB (H.T - N/A)____________
l(Material spec. number, grade or type) (H.T. - time and temp.) l(Material spec. number, grade or type) (H.T. - time and temp.)
Location (Top, Bottom, Thickness Radius Elliptical Conical Flat Side to Pressure Category A
Ends) Ratio Apex Angle Hemis. Radius
Min. Corr. Crown Knuckle Diameter Convex Concave Type Full, Spot, None Eff.
(a) Left End 45.97 mm 2.5 mm N/A N/A N/A N/A N/A 812.8 mm N/A Yes S None 100%
(b) Right End 12.7 mm 2.5 mm N/A N/A 2:1 N/A N/A N/A N/A Yes S None 100%

Body Flanges on Heads


Bolting
How Bolting Washer Washer
Location Type ID OD Flange Thk Min Hub Thk Material Attached Num & Size Material (OD, ID, thk) Material
(a) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
(b) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

8. Type of jacket _______________N/A_______________ Jacket closure


_______________N/A_______________
l(Describe as ogee and weld, bar, etc.)
8. If bar, give dimensions; if bolted, describe or sketch ____________________________N/A_____________________________
9. MAWP 1,200 kPa __N/A__ at max. temp _200 °C__ __N/A__ . Min. design metal temp. ___0 °C____ at 1,200 kPa_ .
l(Internal) l(External) l(Internal) l(External)
10. Impact test _______________No (Exempted as per UG-20(f))________________ at test temperature of _____N/A______ .
l[Indicate yes or no and the component(s) impact tested]
11. Hydro., pneu., or comb. test pressure __Hydro. at 1,560 kPa (R8)___ Proof test ________________N/A________________

Items 12 and 13 to be completed for tube sections.

12. Tubesheet _______N/A________ _______N/A________ _____N/A_____ _____N/A_____ ________N/A________


l[Stationary (material spec. no.)] l[Diameter (subject to press.)] l(Nominal thickness) l(Corr. allow.) l[Attachment (welded or bolted)]
________N/A________ ________N/A________ _____N/A_____ _____N/A_____ ________N/A________
l[Floating (material spec. no.)] l(Diameter) l(Nominal thickness) l(Corr. allow.) l(Attachment)
13. Tubes ________N/A_________ ______N/A______ ______N/A______ ______N/A______ ________N/A_________
l(Material spec. no., grade or type) l(O.D.) l(Nominal thickness) l(Number) l[Type (straight or U)]

(07/17)