0% found this document useful (1 vote)
4K views13 pages

SU KAM Cosmic 800 1400VA Manual PDF

This document provides instructions for operating a high frequency pure sine wave inverter. It begins with an introduction to the inverter's features including microcontroller-based technology using MOSFETs, an SMPS battery charger, overload and short circuit protection, and a graphical display. It then describes the front panel indicators and rear connections for batteries and AC input/output. Safety instructions are provided and technical specifications are listed. In summary, the document is a user manual that outlines the key components and functions of the inverter, how to connect it, important safety guidelines, and specifications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (1 vote)
4K views13 pages

SU KAM Cosmic 800 1400VA Manual PDF

This document provides instructions for operating a high frequency pure sine wave inverter. It begins with an introduction to the inverter's features including microcontroller-based technology using MOSFETs, an SMPS battery charger, overload and short circuit protection, and a graphical display. It then describes the front panel indicators and rear connections for batteries and AC input/output. Safety instructions are provided and technical specifications are listed. In summary, the document is a user manual that outlines the key components and functions of the inverter, how to connect it, important safety guidelines, and specifications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

USER'S MANUAL (IFU)

HIGH FREQUENCY PURE SINE WAVE INVERTER


800VA/1400VA

Salient features
7 Micro controller based
technology using MOSFET
7 SMPS Battery Charger
7 Smart overload sense and short
circuit protection
7 Automatic low battery cutout
7 Low charger ripple voltage to
enhance battery life
7 Great power saving
7 User Friendly Graphical Display
7 Light weight with sleek aesthetic
looks
7 Pure Sine Wave output to run all
appliances satisfactory

GLOBAL CERTIFICATIONS:
R&D
Recognised

ISO 14001:2004 MINISTRY OF SCIENCE & TECHNOLOGY


GOVERNMENT OF INDIA

Before connecting, operating, or adjusting this unit, please read this instruction booklet carefully .
HIGH FREQUENCY PURE SINE WAVE INVERTER

Dear Customer,
We feel immense pleasure while introducing Su-Kam High Frequency Pure Sine
Wave Inverter designed and developed using state-of-the-art Microcontroller
based technology using MOSFET.
The distinguishing features of the Su-Kam High Frequency Pure Sine Wave
Inverter are:
7 Pure Sine wave output to run all 7 Pure DC current SMPS charger,
the appliances increases 50% battery life
7 High Frequency operation 7 Peak Power output 4 times
hence light weight with sleek 7 User Friendly Graphical Display
aesthetic looks
7 Future Expandability possible
7 Smart Overload Sense and Short
Circuit Protection 7 Lesser components so higher
reliability
7 Automatic Low Battery Cutout
7 Lesser water topping required
This manual will help you to better understand your Pure Sine Wave Inverter,
increase your convenience in using it and maximize its benefits for you.
Feel free to contact our authorized dealer or us at [email protected] or
visit our website www.su-kam.com anytime for any clarification or more
information.We value your suggestions and comments. Su-Kam is committed to
continual product improvement and feel the best way to accomplish this task by
listening our valued customers. This commitment gets strengthened every time
you buy a Su-Kam product.
We appreciate the support you have shown us through the purchase of our
product. Please read this manual to become familiar with its features and various
applications.
Regards,
Su-Kam Power Systems Limited
Introduction
REV. 28-02-07
HIGH FREQUENCY PURE SINE WAVE INVERTER

CONTENT

] KNOWING YOUR INVERTER

(A) FRONT PANEL...........................................................................................1-2

(B) BACK PANEL................................................................................................ 3

] IMPORTANT SAFETY INSTRUCTIONS................................................... 4-5

] SPECIAL NOTICES...............................................................................................6

] TROUBLE SHOOTING.......................................................................................7

] TECHNICAL SPECIFICATIONS........................................................................8

] WARRANTY CARD.............................................................................................9

Contents
REV. 28-02-07
HIGH FREQUENCY PURE SINE WAVE INVERTER

KNOWING YOUR INVERTER


Now lets begin the journey to explore various aspect of your Su-Kam High
Frequency Pure Sine Wave Inverter. Welcome aboard!
In its most basic form, an Inverter transforms Direct Current (DC) to Alternating
Current (AC).The battery bank with the Inverter acts as a reservoir to ensure
continuous supply of power whenever mains supply from utility power is not
available.
+ - + -

FRONT PANEL:
MAINS ON INV. ON CHARGE OVER LOAD BATT. LOW

MAINS ON INV. ON BATT. CHRG. OVER LOAD BATT. LOW

On the front panel of the Inverter there is one ON/OFF power active switch, and
a graphic symbol panel for indications.
1. MAINS ON : This graphical symbol, when glows, indicates that the
incoming mains is available.
2. INV. ON : This graphical symbol, when glows indicates that the incoming
mains is not available and the output is from Inverter.
3. BATT. CHARGING / CHARGED : This graphical symbol shows that the
mains line is coming and side by side the charging of batteries is also taking
place. This graphical symbol glows intermittently during charging and glows
continuously when battery is charged.
4. FUSE BLOWN : Mains fuse blows off when the Inverter is operating on
mains and the load connected through the Inverter exceeds the specified
limits prescribed for the Inverter. In this case, at once reduce the extra
load and replace the glass fuse given at back to restore the mains line.
During this stage, the Mains ON graphic symbol glows intermittently with
buzzer beeps .

Front
REV. 28-02-07
Panel
(1)
HIGH FREQUENCY PURE SINE WAVE INVERTER

5. BATT. LOW : This graphical symbol shows that the battery voltage goes
down to a low limit during discharge. After this indication Inverter will
shut down automatically after a few minutes. During this stage graphical
symbol glows and the buzzer gives continuous beep.

6. OVERLOAD/SHORT CIRCUIT : This graphical symbol shows that


either Short circuit has occurred or there is Overload on the Inverter.
The Inverter resets itself automatically and makes 8 attempts in case of
overload and 4 attempts in case of short circuit to turn on again, if the
overload or short circuit continues even after these attempts, it turns
off permanently and will turn on only after ON/OFF power active
switch is turned OFF and then turned ON. In the event of unsuccessful
attempts it automatically shuts down. During overload or short circuit,
graphical symbol lights up and the buzzer gives beep. The beep is
intermittent in case of overload and short circuit. If there is short
circuit at the output, the Inverter will turn off permanently after a few
attempts. It can be reset by removing short circuit and then switching
OFF and ON the power active switch.

Front
Panel REV. 28-02-07
(2)
HIGH FREQUENCY PURE SINE WAVE INVERTER

BACK PANEL:
The Inverter has two battery wires coming out from the rear side,
a Fuse Holder, an output Socket and an input mains
Cable. We connect the two battery wires to the terminals of the
battery, the red colored to positive terminal and the black colored to the
negative. A three core input cable is used to connect the Inverter to
incoming AC Mains. Ensure that incoming phase (or line) is connected to
line (Red wire), neutral is connected to neutral (Black Wire) and earth is
connected to earth (Green Wire). After this the output is connected
through the output socket at the rear of t h e Inverter.

Note : Do not connect Input and Output neutral together in any case
during installation.

Rear View of 800/1400 VA

2 OUTPUT 1. 3 Core Input Wire (Mains Input for Inverter)


3
2. 15A AC Output Socket.
+
FUSE (RED)
4 3. F6.3A/250V (Fast Blow) Fuse for 800VA
-
1 (BLACK) F10A/250V (Fast Blow) Fuse for 1400VA
4. Battery Wires.

Earth BLACK (Input Neutral)


Output Line RED (Input Line)
GREEN
(Earth)
Output Neutral

Back
REV. 28-02-07
Panel
(3)
HIGH FREQUENCY PURE SINE WAVE INVERTER

IMPORTANT SAFETY INSTRUCTIONS


Before proceeding further kindly go through the safety instructions
carefully.
General Precautions:
1. Before using the Inverter read all instructions and cautionary markings
on the Inverter, the Batteries, all appropriate section of this instruction
manual.
2. Do not expose Inverter to rain, liquids of any type. The Inverter is
designed for interiors only.
3. Do not disassemble the Inverter, take it to a Su-Kam Engineering
Service Centre when service or repair is required. Opening by unqualified
personnel entails electric shock or fire hazard.
4. To reduce risk of electric shock, disconnect all wiring before cleaning.
5. Warning-Risk of Explosive gases
WORKING IN THE VICINITY OF A LEAD ACID BATTERY
MAY BE DANGEROUS. BATTERIES GENERATE EXPLOSIVE
GASES DURING NORMAL OPERATION.
Provide ventilation to outdoors from the Battery compartment.
The battery enclosures should be designed to prevent accumulation and
concentration of hydrogen gas in“pockets’’ at the top of the compartment.
Vent the battery compartment from the highest point. A sloped lid can also be
used to direct the flow to the vent opening location. To reduce the risk of
battery explosion, follow all the instructions of batteries supplier or any
equipment you intend to use in the vicinity of batteries.

Safety
Instructions REV. 28-02-07
(4)
HIGH FREQUENCY PURE SINE WAVE INVERTER

6. Do not cover your Inverter with any cover or cloth.


7. Do not install this Inverter on or near flammable materials (plywood,
Chemicals, gasoline etc.).
8. Be extra cautious when working with metal tools on and around batteries.
It could short-circuit the batteries or other electrical parts, producing a spark
that could cause an explosion.
9. Remove conductive jewelry such as rings, bracelets, necklaces and watches
when working with a battery. A battery can produce a short-circuit current
high enough to weld a ring or causing severe burns.

IMPORTANT PRECAUTIONS:
The output side of the Inverter AC wiring should never be connected to a

generator or incoming utility power. This condition is far worse than a short

circuit. If the unit survives this condition, it will shut down until correction is

made.
Note : Never disconnect the battery cables while the Inverter is delivering

power or battery charger is operating.The Power Active Switch has no effect on

the charger; it turns off only the power output during backup mode.To disconnect

the batteries for service:


(a) turn off the power switch.
(b) disconnect all AC power.
(c) disconnect all the battery cables.

Safety
REV. 28-02-07
Instructions
(5)
HIGH FREQUENCY PURE SINE WAVE INVERTER

Special Notices:
! It is recommended to have point to point wiring of the Inverter.
! The Inverter Charger is for use with a nominal battery supply voltage of 12V
DC for 800VA and 24V DC for 1400VA.
! No AC or DC disconnects are provided as an integral part of this inverter.
Both AC and DC disconnects must be provided as part of system
installation.
! No over current protection for the battery supply is provided as an integral
part of this inverter. Over current protection of the battery cables must be
provided as part of the system installation.
! No over current protection for the AC output wiring is provided as an
integral part of this inverter. Over current protection of the AC output
wiring must be provided as part of the system installation.

! GROUNDING INSTRUCTIONS: This Inverter must be


connected to a grounded, permanent wiring system.

NOTE: Do not connect Input and Output neutral together in any case
during installation.

Special
Notices
REV. 28-02-07
HIGH FREQUENCY PURE SINE WAVE INVERTER

TROUBLE SHOOTING

Symptoms Rectifications
Main power is coming. Inverter shows Reduce the load and replace the glass fuse of specified ratings given at
rear side of the Inverter.
mains fuse blown on its display panel

(1)Check if low battery graphic symbol is glowing, switch OFF the Inverter
by power active switch. Allow the battery to charge when the mains is resumed
before running the Inverter on battery again.
No power during backup mode
(2) Check if overload/short circuit graphic symbol is glowing. Reduce load
and reset the Inverter by Power Active switch.

Inverter does not operate Check the battery connections and the mains connections

Inverter trips frequently at backup Reduce the load and restart Inverter through Power Active Switch.
mode

Symptoms Problem Remedy

There is no output power (1) Low Battery. Check condition of batteries and recharge.

(2) Loose or corroded batt. Connections. Check and clean all connections.
(3) Loose AC output connection. Check all AC output connections.
System shuts down after Output of Inverter is wired back to its own Check for proper AC input and output wiring.
20 sec no display at all input.
Low/High AC output Measuring with the wrong type Voltmeter. Meter must be a true RMS reading meter.
voltage
Low surge power Refer to cable and battery recommendations
Weak batteries, battery cable too long.
in this manual.

Unit is excessively hot Internal cooling fan is not working. Contact authorised Su-Kam service engineer.

Trouble
Shooting
REV. 28-02-07
(7)
HIGH FREQUENCY PURE SINE WAVE INVERTER
TECHNICAL SPECIFICATIONS
MODEL SLEEKYDX
CAPACITY 800VA/12V 1400VA/24V
VOLTAGE LIMITS
Mains A.C. Low cut 115 ± 5V
Mains A.C. Low cut Recovery 125 ± 5V
Mains A.C. High cut 285 ± 5V
Mains A.C. High cut Recovery 270 ± 5V
OUTPUT PARAMETER
Mains Output Frequency Same as Input (45 Hz-55Hz)
Inverter Mode Output Frequency 50.0 Hz. ± 0.1 Hz
Inverter Mode Wave form Sine Wave
Overload Above 110%
Short Circuit protection >300% Load (Few msec)
BATTERY CHARGING
SMPS Based Charger with Pure DC Current Charging
Maximum Charging Current Limit 10 ± 1.0 Amp
Charging Float/Boost Voltage 13.7 V ± 0.1 V per 12V battery
Battery Lower Voltage Limit 10.3 V ± 0.2 V per 12V battery
Recommended Battery capacity 135AH-165AH,12V
Number of Batteries 1 2

TECHNOLOGY
Microcontroller based state-of-the-art technology using highly reliable MOSFET
SMPS Based Pure DC charger

ENVIRONMENT
Storage Temperature 0-50oC
Operating Temperature 0-40oC
Humidity 0-90% Non-Condensing

Dimension (W x D x H) in mm 320x285x102 320x285x122


Weight (Kg) 4.5Kg 5.7Kg

Technical Note: Specifications subject to change without prior notice


Specifications REV. 28-02-07
(8)
HIGH FREQUENCY PURE SINE WAVE INVERTER

Term s and conditions of warra nty


SU-KAM POWER SYSTEMS LIMITED warrant to the original purchaser provided the product
is still in possession of and used by the original purchaser from the date of purchase.

The warranty stands on all parts (except LED's, switches and external body) for Inverter will
be for a period of 24 months.

The warranty will be automatically terminate on the expiry of the warranty period, even in
case of the Inverter no t being in use in the specified period.

This warranty is valid only if it is duly signed by the authorized dealer.

The warranty will be invalidated if defects arising in company's opinion by reasons of


accident, abuse, misuse, neglect, improper installation (if not undertaken by the company or
its representative), fire, flood, or other act of GOD and any other natural calamities and any
other unauthorized repairs done or carried out will have to be borne by the purchaser. The
problem of fuse blown will not be included in the warranty of the product. The services given
for the same will be paid service.

The company is in no way are will be held liable for any loss or injury or damage caused to life or
property or death and disability caused to any form of life for any reason whatsoever.

The warranty will not apply if the original seals are found broken or tampered with.

Free service under the terms of warranty will be provided only by authorized
representatives/dealers of the company anywhere in India.

The company expressly denies the right of any person to incur or assure for it any other
liability or obligation in connection with the sale of Inverter.

Claims if any, to this warranty shall be made only before courts having jurisdiction in New
Delhi.

Please send your query or Complaint to [email protected]

Model No. :---------------------------------------------


Serial No. :---------------------------------------------
Name of Purchaser :---------------------------------------------
Address :---------------------------------------------
Date of Purchase :---------------------------------------------
Dealer's Name :---------------------------------------------
DEALER STAMP

Warranty
REV. 28-02-07
(9)
SU-KAM OFFICES ADDRESSES
Hyderabad Bangalore
Plot No. 81, Syndicate Bank Colony
Chennai
H.No.449, Ground Floor, 7 th Cross, 14/50, Gandhi Road, Arumbakkam,
West Marredpally, 6th Main, MICO Layout, BTM II Stage,
Secunderabad-500 026 Chennai- 600106
Bangalore 560076 Tamil Nadu
Andhra Pradesh Karnataka
Tel.: +91-40-32986828, 09347006004 Tel.: 044- 32984497, 09344614009
Tel.: 080-32961610, 09341444693 E-mail : [email protected]
9392004926 E-mail : [email protected]
E-mail: [email protected]

Pune Kolkata Vadodara


Sr. No. 173/2 A, Shop No. 8 & 9,
75, Sarat Chatterjee road L-20/2, Por-Ramangamdi
Suryavanshi Towers
Police Station, Lake Town Indl Estate (GIDC)
Behind Suyoba Karyalaya,
Kolkata 700089 Por, NH-8
Bhekarainagar, Phursungi Taluka,Haveli
West Bengal Vadodara 391243
Pune 418302
Tel: +91 9433266573, 9339195150 Gujarat
Tel. : 020-32303900, 09370658684
E-mail: [email protected] Tel: +91 9377111634, 9327434081
E-mail: [email protected]
E-mail: [email protected]

Indore Ludhiana Ranchi


25, S D A Compound
Shop No. 15, Anmol Market 74/D, Plot No. 1
Lasutia Thana, Devas Naka
VIll. Daad, Pakhowal Raod Park Road 3, Ashok Nagar
Indore 452001
Ludhiana 141002 Ranchi 834002
Madhya Pradesh
Punjab Jharkhand
Tel: +91 9329560222, 9301157800
Tel: +91 9317547976, 9317547978 Tel: +91 9334196088, 9334842729
E-mail: [email protected]
E-mail: [email protected] E-mail: [email protected]

Jaipur Patna Jammu


Maruti Complex
Flat No. G-1, Abhilasha Apartments 76/6, Trikuta Nagar
D 221-D, Bhaskar Marg
Justice Narayan Path, Nageshwar Colony Near Mini Market
Bani Park
Boring Road, Patna 800001 Jammu 180012
Jaipur
Bihar J&K
Rajasthan
Tel: +91 9334121313, 9334842729 Tel: +91 9419310090, 9906310415
Tel: +91-141-3263200
E-mail: [email protected] E-mail: [email protected]
E-mail: [email protected]

Ghaziabad
13/7, Site No. 3
Meerut Road Industry Area
Near Uttam Toyota
Ghaziabad
Uttar Pradesh
Tel: +91-120-2713265, 9312091936,
9350191876, 9313777563
E-mail: [email protected]

SU-KAM POWER SYSTEMS LTD.


FACTORY : A) 64, DIC INDUSTRIAL AREA, BADDI, DISTT. SOLAN (H.P) INDIA
B) 196-C ,SECTOR-37,PH-VI,DISTT. GURGAON (HARYANA) INDIA
REGD.OFF.: WZ-1401/2, NANGAL RAYA , NEW DELHI-46

You might also like