Pipe Flow Expert User Guide
Pipe Flow Expert User Guide
Copyright Notice
© 2012 All Rights Reserved
Daxesoft Ltd.
Distribution Limited to Authorized Persons Only.
Trade Secret Notice
The PipeFlow.com, PipeFlow.co.uk and Daxesoft Ltd. name and logo and all related product and service names, design marks,
logos, and slogans are either trademarks or registered trademarks of Daxesoft Ltd. All other product names and trademarks
contained herein are the trademarks of their respective owners.
Printed in the United Kingdom - October 2012
Information in this document is subject to change without notice. The software described in this document is furnished under a
license agreement. The software may be used only in accordance with the terms of the license agreement. It is against the law to
copy the software on any medium except as specifically allowed in the license agreement. No part of this document may be
reproduced or transmitted in any form or by any means electronic or mechanical, including photocopying, recording, or information
recording and retrieval systems, for any purpose without the express written permission of Daxesoft Ltd.
Calculations and Results 3
Table of Contents
Table of Contents .................................................................................................................................... 3
Table of Figures ...................................................................................................................................... 8
Introduction ........................................................................................................................................... 11
Welcome to Pipe Flow Expert ........................................................................................................... 11
Pipe Flow Expert Overview ............................................................................................................... 11
Minimum Operating System Requirements ....................................................................................... 12
Registration and Licensing Information ............................................................................................. 13
Contacting PipeFlow.com ................................................................................................................. 15
Additional Pipe Flow Software Programs .......................................................................................... 15
Interface and Menus .............................................................................................................................. 16
Menu Bar ......................................................................................................................................... 16
File Menu .................................................................................................................................... 17
Edit Menu .................................................................................................................................... 19
Units Menu .................................................................................................................................. 20
Fluid Menu .................................................................................................................................. 20
Drawing Menu ............................................................................................................................. 22
Tools Menu ................................................................................................................................. 23
License Menu .............................................................................................................................. 23
Documentation Menu................................................................................................................... 24
Help Menu ................................................................................................................................... 25
Tool Bar ........................................................................................................................................... 26
Tool Bar Buttons.......................................................................................................................... 26
Keyboard Shortcuts ..................................................................................................................... 30
Node Pane ....................................................................................................................................... 30
Node Types ................................................................................................................................. 30
Tank Node Data .......................................................................................................................... 31
End Pressure Data ...................................................................................................................... 32
Join Point Data ............................................................................................................................ 33
Flow Demands ............................................................................................................................ 34
Pipe Pane......................................................................................................................................... 35
Pipe Features .............................................................................................................................. 35
Pipe Material Data ....................................................................................................................... 37
Pipe Diameter Data ..................................................................................................................... 39
Pipe Fittings Database ................................................................................................................. 41
Component Pressure Loss .......................................................................................................... 43
Control Valve Data ...................................................................................................................... 44
Pump Data .................................................................................................................................. 45
4 Pipe Flow Expert User Guide
Table of Figures
Figure 1 Pipe Flow Expert License Registration .................................................................................... 13
Figure 2 Pipe Flow Expert interface ...................................................................................................... 16
Figure 3 Menu Bar ................................................................................................................................ 16
Figure 4 File Menu................................................................................................................................ 17
Figure 5 Edit Menu ............................................................................................................................... 19
Figure 6 Units Menu ............................................................................................................................. 20
Figure 7 Fluid Menu.............................................................................................................................. 20
Figure 8 Drawing Menu......................................................................................................................... 22
Figure 9 Tools Menu ............................................................................................................................. 23
Figure 10 License Menu ....................................................................................................................... 23
Figure 11 Documentation Menu ............................................................................................................ 24
Figure 12 Help Menu ............................................................................................................................ 25
Figure 13 Tank Node Pane ................................................................................................................... 31
Figure 14 End Pressure Node Pane...................................................................................................... 32
Figure 15 Join Point Node Pane ........................................................................................................... 33
Figure 16 Flow Demands ...................................................................................................................... 34
Figure 17 Pipe Pane and Pipe Sub-menu ............................................................................................. 35
Figure 18 Pipe Material Data ................................................................................................................ 37
Figure 19 Pipe Diameter Data............................................................................................................... 39
Figure 20 Pipe Fittings Database .......................................................................................................... 41
Figure 21 Component Pressure Loss .................................................................................................... 43
Figure 22 Control Valve Data ................................................................................................................ 44
Figure 23 Pump Data............................................................................................................................ 45
Figure 24 Drawing Panes Standard or Isometric ................................................................................... 48
Figure 25 Configuration Options - Labelling Tab ................................................................................... 49
Figure 26 Configuration Options - Units Tab ......................................................................................... 51
Figure 27 Configuration Options - Pipe Settings Tab ............................................................................. 53
Figure 28 Configuration Options - Node Updates Tab ........................................................................... 55
Figure 29 Configuration Options - Results Colors tab ............................................................................ 56
Figure 30 Configuration Options - Calculations Tab .............................................................................. 57
Figure 31 Results tables ....................................................................................................................... 59
Figure 32 View Individual Results ......................................................................................................... 61
Figure 33 Save As dialog ...................................................................................................................... 64
Figure 34 Printing Information dialog..................................................................................................... 66
Figure 35 Configuration Options – Labelling tab .................................................................................... 69
Calculations and Results 9
Introduction
The Pipe Flow Expert program will allow you to draw a complex pipeline system and analyze the
features of the system when flow is occurring.
Pipe Flow Expert calculates the balanced steady flow and pressure conditions of the system.
It will allow you to perform analysis of alternate systems under various operating conditions.
The input and display of system information on the Pipe Flow Expert drawing and in the results
tables can be shown in metric or imperial units to suit your preference and specific units for each
item (such as flow rate) can also be configured and set on an individual basis as required.
Pipe Flow Expert has been designed for the professional engineer who needs a powerful tool that
has a class leading, easy to use and robust interface that makes it simple to design and analyze pipe
networks.
The pipelines may vary in size and nature and will usually involve changes in elevation from one
point to another. These pipeline systems may include reservoirs, pressurized tanks, pumps, valves,
flow control devices, heat exchangers and other components that affect flow in the pipelines.
12 Pipe Flow Expert User Guide
The pipeline system is modeled by drawing the join points and the connecting pipes on a drawing
pane. Horizontal, vertical or sloping lines can be used to connect one node to another node.
The physical data describing the system is entered by the user and typically includes:
• The internal size, internal roughness and length of each connecting pipe
• The elevation of each join point (node)
• The In-flow and the Out-flow at each join point (if applicable)
• The elevation, liquid level and surface pressure data for each tank
• The performance data for each pump
Data input boxes are located at the left hand side of the drawing pane. These input boxes will display
the data for the currently selected node or pipe and may be used to amend the current data. The
data for a node, pipe, pump, etc. can be amended at any point during the design process.
Once the design has been completed, the system can be analyzed and the flow and pressure results
can be calculated. The pressure losses within the system are calculated using friction factors
obtained from the Colebrook-White equation, and the friction pressure loss for each pipe is obtained
from the Darcy-Weisbach equation.
An initial approximate solution is obtained using Linear Theory methods and an iterative approach to
adjust the flow rates until an approximate pressure balance is achieved.
An alternative approach is to use estimates for the out-flows and to use these estimates to set an
initial flow rate in each pipe, with the total in-flow to each join point matching the total out-flow from
each join point. The initial flow estimates are unlikely to give a balanced pressure result over the
whole system and must be further refined using an iterative approach to adjust the flow rates until an
approximate pressure balance is achieved.
Pipe Flow Expert defines the elements of the pipeline system in a series of matrix equations and
uses the Newton method to adjust the estimates for the flow rate in each pipe.
Once an approximate solution has been obtained, the results are refined using a variation of the
Newton method to ensure convergence until a balanced pressure result is obtained.
The results of the flow rates for each pipe, the fluid velocities for each pipe, Reynolds numbers,
friction factors, friction pressure losses for each pipe, fittings pressure losses, pressure at join points
(nodes), HGL (hydraulic grade line), pump operating points and more can be viewed on the drawing
and on the results grid.
It is recommended that your computer system has at least the following minimum specification:
Microsoft® Excel is required if the user wishes to export the results tables to a spreadsheet format.
Calculations and Results 13
Installation
When the program is installed it generates a unique product number that is shown on the registration
screen when you run the program. A matching license code must be entered to fully enable and
license the software.
Purchasing a License
Each installation of the software requires a license that must be purchased from
www.PipeFlow.com - current prices are shown on the web site.
Once enabled, the software can be used ‘forever’ on the machine to which it was installed.
You do not require an internet connection when licensing and enabling the software.
Moving a License
We have a method of allowing a user to move the license to another machine and this service is
provided free of charge for those users who have an ongoing annual support and maintenance
agreement. A fee is charged for generating a new license code for users who do not have an
ongoing annual support package.
14 Pipe Flow Expert User Guide
Network Licensing
The software can be operated over a network and used by a number of concurrent users. Network
installation is simple and only requires that the software is installed to a shared network drive. Each
user then runs the program as normal from the shared drive. When licensing the program you will
need to purchase a software license that supports the maximum number of concurrent users that
you require.
Please email [email protected] with your network licensing requirements to obtain a competitive
quote for your specific needs.
All of our software is provided via download from our web sites at www.pipeflow.com and
www.pipeflow.co.uk
We do not provide the software on CD, since it would be exactly the same as the program that can
be downloaded from our web site. This helps to reduce our costs, which allows us to offer lower
prices for our customers and also guarantees that the user is always installing the latest version of
the software. Users are free to make their own CD copy of the software, however every installation of
the program will generate a new product code and a new license code will still be required.
New Customers
Those of you who have previously purchased software from us will already be assured of our
reputation and will not be concerned about receiving the software via download. However we
understand that as a new customer you may be concerned that you do not get a CD with the
software on.
If we provided the software on CD it would be the exact same program that you can download from
our web site (in fact the web site will always carry the very latest version of the software). Having a
CD would not allow you to install and enable the software on multiple computers, since each
installation would still generate a unique product number and would require a matching license code.
When you purchase a program from our web site, you will automatically be emailed with a unique
purchase token and an invoice/receipt that confirms your purchase. This is all you need for proof of
purchase and we will always be able to confirm your purchase in our database.
We have sold software via download for over 10 years. We are not one of those companies who you
will not be able to contact or get a response from. As our existing customers know, our service and
assistance with any issues you may have is worth far more than just having the software on CD.
Summary
• Pipe Flow Expert can be downloaded and installed for a free trial.
• A license code can be purchased from our web site that will fully enable the software.
• A user can be up and running with a licensed version of the software within a few minutes.
• 90 days of annual support and maintenance is provided with your purchase of Pipe Flow
Expert.
• Ongoing annual support and maintenance can be purchased from our web site (this provides
email support and guarantees that you will always be able to use the latest version of the
software).
Calculations and Results 15
Contacting PipeFlow.com
Email: [email protected]
Internet: http://www.pipeflow.com
PipeFlow.com and PipeFlow.co.uk are trading names of Daxesoft Ltd (U.K. Registered
Company)
Pipe Flow Wizard is able to perform four different calculations depending on the known information.
It can calculate:
• Pressure Drops
• Flow Rates
• Size of Internal Diameters
• Pipe Lengths
A Materials Database is included with density and coefficient of expansion of common materials.
All of our software can be downloaded for a free trial by visiting www.pipeflow.com
Once you have installed a trial version of one of our software products it can be fully enabled and
licensed by buying a purchase token / license from our web site. You can be up and running with a
fully licensed program within just a couple of minutes
16 Pipe Flow Expert User Guide
Menu Bar
The menu bar has nine different menu selections to help you navigate and work in Pipe Flow Expert.
File Menu
Email Screen Image Opens a new e-mail message with a jpeg of the screen image attached
to the e-mail.
Create PDF – System Drawing Create a PDF document of the system drawing.
Create PDF – Customized Create a PDF customized report, including cover sheet with logo image,
Report system drawing and results tables. Including a high resolution pump
graph with performance curves.
Print Opens the Printing Information dialog. Type the page title and click
the Print button to print the image currently visible in the Drawing pane.
Page Setup Opens the Print Setup dialog. Define your printing preferences and
click OK
Recover from AutoSave Files Pipe Flow Expert will automatically save a backup of your current
design at approximately 5 minute intervals. In the event of a problem
you can try to load the most recent backup file to try and recover your
system.
Purge Auto Saved Files Delete the files created by the auto save feature.
Exit Closes the application.
Calculations and Results 19
Edit Menu
Units Menu
Fluid Menu
Drawing Menu
Tools Menu
License Menu
Documentation Menu
Help Menu
Tool Bar
Most of the Pipe Flow Expert functions can be performed by using a button on the tool bar. The Re-
Design, Results Sheet, Results PDF and Show Log buttons are only available on the tool bar after
you click the Calculate button on the tool bar.
The tool bar also contains a field for determining whether the unit values displayed in Pipe Flow
Expert and the pipe system are imperial or metric. The first step in creating a pipe system is to select
the Imperial or Metric option. You can define whether imperial or metric values are used from the tool
bar, the Units menu, or from the Units tab in the Configuration Options dialog. Inches, feet, and
gallons are examples of imperial units. Centimeters, meters, and liters are examples of metric units.
Open File – Opens the Open dialog. Select a .pfe file and click the Open button to open an
existing pipe system drawing in Pipe Flow Expert.
Save File – Saves your changes to the pipe system drawing.
Email System Information – Opens a new e-mail message with the pipe system .pfe file
attached to the e-mail.
Email Screen Image – Opens a new e-mail message with a jpeg of the screen image
attached to the e-mail.
Print – Opens the Printing Information dialog. Type the page title and click the Print button
to print the image currently visible in the Drawing pane.
Create PDF of System Drawing – Produces a high resolution PDF of the system drawing
including items which may be currently off-screen.
Toggle Isometric Grid – Switch to Isometric Drawing Grid, or back to Standard Grid.
Choose Labelling – Opens the Labelling tab of the Configurations Options dialog. Use
the Labelling tab to define how the pipe system is labelled in the Drawing pane.
Choose Units – Opens the Units tab of the Configurations Options dialog. Use the Units
tab to define the units for each element of the pipe system.
Set Pipe Default Drawing Values – Opens the Pipe Settings tab of the Configurations
Options dialog. Use the Pipe Settings tab to define the pipe default values for drawing or to
copy some of the pipe attributes to selected pipes in the system.
Network Grid View – Opens a grid to display details of pipes, tanks, end pressures and
nodes. The data displayed in the grid may be edited to change the network data. Any
changes are applied immediately to the drawing.
Calculations and Results 27
The Hint pane displays tips for using the button currently selected on the tool bar. The Hint
pane displays tips for the following buttons:
In Results mode the Hint pane is used to display information about the flow rates in pipes,
velocities in pipes, pressure drop in pipes, pressures at join points, HGL (hydraulic grade
line), elevations of tanks and nodes, and fluid heads in the pipeline system. Items are
highlighted by clicking on an item in the drawing pane. Data for the highlighted item is
displayed in the hint pane.
Fluid – Opens the Fluid menu, select change fluid to open the Fluid data dialog. Use the
Fluid data dialog to define the fluid for the currently selected fluid zone. Select other fluid
menu options to change the fluid zone color or to create a new fluid zone or to delete a
fluid zone.
Zoom Out – Moves the focus of the pipe system out to see more of the drawing at a
reduced size in the Drawing pane.
Zoom In – Moves the focus of the pipe system in to get a close-up view in the Drawing
pane.
Move to Centre of Grid – Centers the pipe system on the drawing grid.
Show Item Info – Select the show information cursor. Click an item in the Drawing pane to
display its details in the Node pane, Pipe pane, or dialog associated with the selected
component.
Pan the Drawing – Select the move grid cursor. Click in the Drawing pane, and while
holding down the left mouse button, move the mouse to pan the drawing.
Drag and Move Items – Highlights all items on the drawing. Select a highlighted object, and
while holding down the left mouse button, drag the object to its new position.
Add Tank – Select the tank cursor. Click where you want to add a tank in the Drawing pane.
Use the Node pane to enter the Elevation, Liquid level and Fluid surface pressure for the
tank.
Add Demand (Pressure) – Select the end pressure cursor. Click where you want to add a
fixed pressure demand in the Drawing pane. Use the Node pane to enter the pressure and
elevation for this fixed pressure demand.
Add Join Point – Select the join point (node) cursor. Click where you want to add a pipe join
point in the Drawing pane.
Add Pipes – Select the draw pipes cursor. Click on a node in the Drawing pane where you
want to add a pipe, and then click where you want the pipe to end. Right-click to turn off the
rubber banding.
Add Fittings – Select the valve and fittings cursor. Click on the pipe on which you want to
add valves or fittings. Use the Pipe fittings friction coefficients dialog to select the valves
or fitting to be added.
Add Component Pressure Loss – Select the component cursor. Click on the pipe on which
you want to add a component. Use the Component pressure loss dialog to enter the
pressure loss characteristics of the component.
28 Pipe Flow Expert User Guide
Add Control Valve – Select the control valve cursor. Click on the pipe on which you want to
add a control valve. Use the Control data dialog to choose a flow valve type. Choose a
Flow Control Valve (FCV) to set the flow rate required in the pipe, or a Pressure Reducing
Valve (PRV) to set the pressure required at the end of the pipe, or a Back Pressure Valve
(BPV) to set the pressure required at the start of the pipe.
Add Pump – Select the pump cursor. Click on the pipe on which you want to add a pump.
Use the Pump data dialog to enter the pump performance characteristics.
Add Demand (Flow) – Select the add demand flow cursor. Click on a node in the Drawing
pane where you want to set a demand flow. Use the Flow demands dialog to set the In-
flows or Out-flows at the selected node.
Toggle to Open/Close a Pipe – Select the open/close pipe cursor. Click on a pipe in the
Drawing pane where you want to close a pipe or to re-open a pipe that has been closed
previously.
Selection Tool – Select the selection rectangle cursor. Click in the Drawing pane, and while
holding down the left mouse button, drag the mouse to create a rectangle around the item(s)
you want to select for cutting, copying, pasting, deleting or moving. You can select multiple
items to cut, copy, paste, delete or move as a group. Click the right mouse button to exit
from selection mode.
Zoom Selected Area – Displays the selection area in a close-up view in the centre of the
Drawing pane.
Select Individual Pipes and Nodes – Use the Adjust attributes of Selected Pipes tool
button to display the Pipe Settings tab to make changes to all selected pipes.
Use the Adjust attributes of Selected Nodes tool button to display the Node Settings tab to
make changes to all selected nodes.
Adjust Attributes of Selected Pipes – Opens the Pipe Settings tab of the Configurations
Options dialog. Use the Pipe Settings tab to copy various attributes of the default pipe to
each of the pipes selected. The Selection Tool may be used to Select a group of pipes prior
to opening the Pipe Settings tab. Individual pipes can be added or removed from the
selected list by checking or un-checking the box adjacent to the pipe description.
Adjust Attributes of Selected Nodes – Opens the Node Updates tab of the
Configurations Options dialog. Use the Node Updates tab to copy node elevation and
images to each of the nodes selected. The Selection Tool may be used to Select a group of
nodes prior to opening the Node Updates tab. Individual nodes can be added or removed
from the selected list by checking or un-checking the box adjacent to the node description.
Delete – Selected item(s) are deleted. If a selected item is a node then all pipes which
connect to the node will also be deleted.
Undo last action – The last add pipe or node action performed in the Drawing pane is
undone.
Calculations and Results 29
Calculate – Calculates the flow and pressure at each node of the pipe system drawing. The
calculation results are displayed on the Results window.
Re Design – Changes the view back to the design mode. The pipe system is displayed in
drawing mode again. This button is only visible on the tool bar after clicking the Calculate
button.
Results – Opens the Results window. This button is only visible on the tool bar after clicking
the Calculate button.
Results PDF – Opens the Results PDF dialog. Add a logo, chose the options required and
produce a PDF of the results, including a system image and pump graphs. This button is
only visible on the tool bar after clicking the Calculate button.
Show Log – Opens the Results Log dialog. The Results Log dialog indicates whether the
pipe system was solved. This button is only visible on the tool bar after clicking the Calculate
button.
Example Systems – Opens the Example Systems dialog. Over 40 examples systems are
provided to illustrate usage of the Pipe Flow Expert software. This button is only visible on
the tool bar if design mode is selected.
Next Example – Loads the Next Example System from the examples systems dialog. This
button is only visible on the tool bar if design mode is selected.
New Tab – Opens a new design sheet allowing users to work on multiple systems
simultaneously. Tabbed Sheets work in both Design View and Results Mode. Switch
between different system models with a single click
30 Pipe Flow Expert User Guide
Keyboard Shortcuts
Various keyboard shortcuts are provided which duplicate the actions of some Menu system options
and some of the Tool Bar buttons.
Node Pane
The Node pane displays the properties of the node selected on the pipe system in the Drawing pane.
The type of node selected in the Type field determines which features are available in the Node
pane.
Node Types
A node can be a join point, tank, or demand pressure–referred to as End Pressure in the Node pane.
The type of node selected is shown in the Type field. The type of node can be changed by selecting
from the options shown in drop down type list.
Nodes are located at the beginning and end of a pipe and at the junction of pipes in a pipe system.
You can use the drop down Node Id list next to the Node name field to select an individual node or to
scroll through each of the nodes in the pipe system.
Click the zoom button next to the drop down Node Id list to redisplay the drawing with the
selected node at the center of the visible drawing area.
The Node pane is also used to enter and edit the specific details for the selected node. The values
and units displayed in the node pane are determined by the units selected on the Units tab in the
Configuration Options dialog. The selected units can also be switched on mass between a
predefined set of imperial and metric units.
Calculations and Results 31
Feature Description
Node The name of the node currently selected in the Drawing pane. Use the
Node field to edit the node name.
Node Id List Use the Node Drop Down List to select a node or to scroll through each
of the nodes in the pipe system.
Type (Tank) The type of node currently selected in the Drawing pane. Use the Type
field to modify the node type. There are three types of nodes – join point,
tank, or fixed pressure demand (End Pressure).
Type (Tank Icon) Displays the image representing the selected tank in the Drawing pane.
Use the Icon button to select the tank image you want displayed on the
pipe system drawing.
The icon size can be selected from a range of scales.
The image you select does not affect any of the tank’s
properties or values.
Surface Pressure The surface pressure of the fluid in the tank expressed in the units
displayed.
Liquid Level The amount of fluid above the tank exit point expressed in the units
displayed.
Elevation (Exit from tank) The elevation at the exit point of the tank expressed in the units
displayed.
Notes Notes about the node currently selected in the Drawing pane. Notes can
be up to 200 characters.
32 Pipe Flow Expert User Guide
Feature Description
Node The name of the node currently selected in the Drawing pane. Use the
Node field to edit the node name.
Node Id List Use the Node Drop Down List to select a node or to scroll through each
of the nodes in the pipe system.
Type (End Pressure) The type of node currently selected in the Drawing pane. Use the Type
field to modify the node type. There are three types of nodes – join point,
tank, or demand pressure (End Pressure).
Type (End Pressure Icon) Displays the image representing the selected demand pressure in the
Drawing pane. Use the Icon button to select the end pressure image you
want displayed on the pipe system drawing.
The icon size can be selected from a range of scales.
The image you select does not affect any of the demand
pressure’s properties or values.
Pressure The required pressure for the end pressure expressed in the units
displayed.
Elevation (of Pressure Point) The elevation of the end pressure expressed in the units displayed.
Notes Notes about the node currently selected in the Drawing pane. Notes can
be up to 200 characters.
Calculations and Results 33
Feature Description
Node Identification Use the Node Drop Down List to select a node or to scroll through each of
Number the nodes in the pipe system.
Node The name of the node currently selected in the Drawing pane. Use the
Node field to edit the node name.
Type (Join Point) The type of node currently selected in the Drawing pane. Use the Type
field to modify the node type. There are three types of nodes – join point,
tank, or demand pressure (End Pressure).
Type (Join Point) Icon Displays the image representing the join point in the Drawing pane. Use the
Icon button to select the join point image you want displayed on the pipe
system drawing.
The icon size can be selected from a range of scales. The
image you select does not affect any of the joint point
properties or values.
Elevation of Join Point The elevation of the join point expressed in the units displayed.
Demands In (at Join Point) View the In Flow to the system at this node. Click edit to change.
Demands Out (at Join Point) View the Out Flow from the system at this node. Click edit to change.
Edit buttons (Join Point) Opens the Set Flow Demands dialog. This dialog is used to set a demand
flow on the join point.
Notes Notes about the node currently selected in the Drawing pane. Notes can be
up to 200 characters.
34 Pipe Flow Expert User Guide
Flow Demands
Flow demands can only be added at a node if the type selected is a Join Point.
Feature Description
In Flow Rate Entering The The flow rate entering the system at this node expressed in the units
System displayed.
Out Flow Rate Leaving The The flow rate leaving the system at this node expressed in the units
System displayed.
OK Confirm any changes that have been made.
Cancel Close the dialog without making any changes.
Calculations and Results 35
Pipe Pane
A pipe can have many features, such as name, length, internal diameter, roughness, nominal size,
material, schedule or class reference, internal volume and surface area.
The data for some of these features, such as name, length, internal diameter and roughness can be
entered directly into the pipe pane input boxes (other features would be left unchanged and may
have to be amended at a later time).
To set all the features of a pipe use the Diameter and Material buttons to access the selection
dialogs.
Pipe Flow Expert allows fittings and valves, components, flow control valves and pumps to be added
to a pipe. The selection dialogs to add or change the data for these items can be accessed by
clicking on the appropriate button in the pipe pane.
Pipe Features
Feature Description
Pipe Identification Number Use the Pipe Drop Down List to select a pipe or to scroll through each
of the pipes in the pipe system.
Name The name of the pipe currently selected in the Drawing pane. Use the
Name field to edit the pipe name.
Length The length of the pipe currently selected in the Drawing pane. Use the
length field to change the length of the pipe.
36 Pipe Flow Expert User Guide
Internal Diameter The internal diameter of the pipe currently selected in the Drawing pane.
Use the internal diameter field to change the internal size of the pipe.
Click the Diam? button to display the Pipe Diameter Database sizes.
Roughness The internal roughness of the pipe currently selected in the Drawing
pane. Use the roughness field to change the internal roughness of the
pipe. Click the Material button to display the Pipe Material Database.
Notes Notes about the pipe currently selected in the Drawing pane. Notes can
be up to 200 characters.
Pipe Color and Line Width Set the color and line width of the pipe currently selected in the Drawing
pane.
Add/Change Fittings button Opens the Pipe fitting friction coefficients database. Use the
database to add and maintain fittings on a pipe. The number of fittings
on the pipe is displayed next to the fitting image on the Add/Change
Fitting button.
Add/Change Component Add a component to the pipe currently selected in the drawing pane.
Pressure Loss button Change the Pressure Loss characteristics for the component. A number
is displayed next to the Component image to indicate if the component is
active.
Add/Change Control Valve Add a control valve to the pipe currently selected in the drawing pane.
button Set the maximum flow rate in the pipe by using a flow Control Valve
(FCV), or set the pressure at the end of the pipe by using a Pressure
Reducing Valve (PRV), or set the pressure at the start of the pipe by
using a Back Pressure Valve (BPV). A number is displayed next to the
Control Valve image to indicate if the Control Valve is active.
Add/Change Pump button Add a pump to the pipe currently selected in the Drawing pane. Enter
the flow rate and head characteristics for various points on the pump
performance curve. A number is displayed next to the Pump image to
indicate if the Pump is active.
Include check boxes Include/Exclude status for various items added to the pipe currently
selected in the Drawing pane.
i.e. Fittings & Valves, Components, Control Valves, Pumps.
Diam? Display the Pipe Diameter Size Database. A Double Click on a pipe will
also display the Pipe Diameter Size Database.
Material Display the Pipe Material Database.
More…. Opens the pipe sub menu which provides further options to:
• Re-Open / Close Pipe
• Reverse Pipe Direction
• Prevent Backflow – On / Off
• Move / Unlink end of Pipe
• Use Pipe Values for as default for the next pipe to be drawn
• Change Fluid Zone (for pipe)
• Close sub menu
A Right Click on a pipe will also display the pipe sub menu.
Calculations and Results 37
Feature Description
Material The material description of the pipe currently selected in the Drawing pane.
Schedule/Class The Schedule/Class description of the pipe currently selected in the
Drawing pane.
Internal Roughness The internal roughness of the pipe currently selected in the Drawing pane.
Nominal Size The Nominal Size description of the pipe currently selected in the Drawing
pane.
Internal Diam. The internal diameter of the pipe currently selected in the Drawing pane.
Wall Thick The wall thickness of the pipe currently selected in the Drawing pane.
Outside Diam The outside diameter of the pipe currently selected in the Drawing pane.
Weight The weight per unit length of the pipe currently selected in the Drawing
pane.
Internal Vol. The internal volume (ft³/100 ft or m³/100m) of the pipe currently selected in
the Drawing pane.
Surface Area The external surface area (ft²/100 ft or m²/100m) of the pipe currently
selected in the Drawing pane.
Save Pipe This button is not available during pipe material selection.
Cancel (Changes) This button is not available during pipe material selection.
38 Pipe Flow Expert User Guide
Feature Description
Material The material description of the pipe currently selected in the drawing
pane.
Schedule/Class The Schedule/Class description of the pipe currently selected in the
drawing pane.
Internal Roughness The internal roughness of the pipe currently selected in the drawing
pane.
Nominal Size The Nominal Size description of the pipe currently selected in the
drawing pane.
Internal Diam. The internal diameter of the pipe currently selected in the drawing pane.
Wall Thick The wall thickness of the pipe currently selected in the drawing pane.
Outside Diam The outside diameter of the pipe currently selected in the drawing pane.
Weight The weight per unit length of the pipe currently selected in the drawing
pane
Internal Vol. The internal volume (ft³/100 ft or m³/100m) of the pipe currently selected
in the drawing pane.
Surface Area The external surface area (ft²/100 ft or m²/100m) of the pipe currently
selected in the drawing pane.
40 Pipe Flow Expert User Guide
Save Pipe Save the selected data to the pipe currently selected in the drawing
pane.
Cancel Close the Pipe Diameter database without making any changes.
Transfer Selected Size Copy size data from data listing to entry boxes (at top of the screen).
Size data listing Listing of pipe sizes.
Metric or Imperial Display size data in metric or imperial units.
Change Material Display data dialog for pipe material.
Add new size Display input boxes for new pipe size data.
Remove entry Remove a pipe size.
Calculations and Results 41
Feature Description
Symbol Fitting type symbol.
Type Fitting type short code.
Metric Nominal metric fitting size.
Imperial Nominal imperial fitting size.
Description Fitting description.
K value Local loss coefficient of fitting.
Qty Quantity of fittings.
Save Save the fitting selections to the pipe currently selected in the drawing
pane.
Clear Clear the fitting selections.
Cancel Close the Pipe Fittings Database without making any changes.
Pipe Size Click to display fittings to match the current pipe size.
Metric Pipe Sizes (mm) Drop down list of metric pipe sizes, click to display matching fitting sizes.
Imperial Pipe Sizes (inch) Drop down list of imperial pipe sizes, click to display matching fitting
sizes.
Fitting Database Listing of fittings and friction coefficients.
42 Pipe Flow Expert User Guide
Add Selected Item On To Pipe Copy fitting data from listing to the list on the currently selected pipe.
Calculate K value Calculate local loss coefficient for: entrance rounded, gradual
enlargement, gradual contraction, sudden enlargement, sudden
contraction or long pipe bend.
Create new fitting Create data for non standard fittings.
Remove entry Remove data from fittings database.
Calculations and Results 43
Feature Description
Component Name Name of the component.
Pressure Loss Scroll buttons Choose symbol for the component.
Fixed Loss Pressure loss will be fixed.
Curve Loss Pressure loss will be calculated from component flow / head data.
Flow Flow rate values for operating range of component.
Pressure Loss Pressure loss for each of the flow rate entries.
Generate Curve Create a set of curve points from first three data points.
Cv Flow Coefficient Value Model pressure loss through a valve with a Cv flow coefficient
Kv Flow Coefficient Value Model pressure loss through a valve with a Kv flow coefficient
OK Add the component to the pipe currently selected in the Drawing pane.
Cancel Close the dialog without making any changes.
Clear Clear the pressure loss data.
Delete Remove the component from the pipe currently selected in the drawing
pane.
Save To File Save the component details to a file.
Load From File Load the component details from a file.
44 Pipe Flow Expert User Guide
Feature Description
Control Name Name of the control valve or P&ID number.
Flow Control Valve Set control flow rate in the units displayed.
Pressure Reducing Valve Set pressure required at the end of the pipe.
Back Pressure Valve Set back pressure required at the start of the pipe.
Specify Allowable dP Range Set allowable dP Range, a warning will be issued if the actual dP is
outside the lower and upper values.
OK Add the control valve type to the pipe currently selected in the Drawing
pane.
Cancel Close the dialog without making any changes.
Delete Remove the control valve from the pipe currently selected in the
Drawing pane.
Calculations and Results 45
Pump Data
The main features of the pump data dialog are listed in the table below. The pump section later in
this document provides further details of the Graph Options, the Pump Data Menu options and
the options for opening the Pump Database, adding a pump to the Pump Database, Import of a
Curve Image and creating a Pump Data Sheet.
Feature Description
Name Name of the pump.
Distance Along Pipe Location of the pump from start of the pipe currently selected in the
drawing pane.
at Elevation Elevation of the pump.
Pump Scroll buttons Choose symbol for the pump.
Set Flow Rate Enter flow rate to model a pump with a fixed flow rate
Set Head Increase Enter a head or pressure to model the additional motive force from a
pump
Set Speed (rpm) Operating speed of a pump with a performance curve.
Set Impeller Diameter Set impeller diameter size & units
46 Pipe Flow Expert User Guide
Flow Flow rate values for operating range of pump. Displayed in units
selected from drop down list.
Head Head generated for each of the flow rate entries. Displayed in units
selected from drop down list.
Efficiency Efficiency of the pump at each of the operating data points.
NPSHr The Net Positive Suction Head requirement at the inlet of the pump for
the flow rate value.
From (% of BEP) Start of preferred operating region.
To (% of BEP) End of preferred operating region.
Clear Pump Curve Clear the pump data.
Delete Pump Remove the pump from the pipe currently selected in the drawing pane.
Cancel and Close Close the dialog without saving any changes
Graph Options Opens additional graph options customization dialog. Allows creation of
additional data curves and adjustment of Iso efficiency lines.
See later section about Pumps for further details.
Draw Graph Draw a pump graph based on entered data points.
Save Pump to Pipe Add the pump to the pipe currently selected in the drawing pane.
Pump Catalog The name of the pump catalog.
Manufacturer The name of the pump manufacturer.
Type The type of pump.
Motor rpm The motor speed.
Pump Size The pump size reference.
Stages The number of pump stages.
Notes Notes about the pump. Notes can be up to 200 characters.
Min Speed The minimum operating speed of the pump.
Max Speed The maximum operating speed of the pump.
Min Impeller The minimum impeller diameter for the pump.
Max Impeller The maximum impeller diameter for the pump.
Speed (rpm) Operating speed of the pump impellor diameter for the duty curve.
Diam The diameter of the pump impeller, in the units shown.
Flow The flow rate of the pump duty point, in the units shown.
Head The head produced by the pump at the duty point, in the units shown.
NPSHr The Net Positive Suction Head requirement at the inlet of the pump for
the flow rate at the duty point.
Effic. % The pump efficiency at the duty point.
Power The shaft power required at the duty point.
Calculate (Button) Click to calculate the duty point details for an entered flow rate or head
requirement.
Logo (Button) Add a logo to the pump graph image
Expand (Button) Expand graph to show in full window
Calculations and Results 47
Drawing Pane
48 Pipe Flow Expert User Guide
Feature Description
Drawing Grid The drawing grid shows details of the pipeline system. The information
to be displayed, such as size, length, elevation, flow rate etc. can be
selected from the configuration options labelling tab.
Hint Feature The Hint pane, located above the tool bar, displays tips for using the
button currently selected on the tool bar.
Zoom Feature If your mouse is suitable the drawing size can be zoomed larger or
smaller using the mouse scroll wheel.
Drawing Size Display The drawing size can be selected from the drop down listing between
the Zoom Out and the Zoom In buttons.
Zoom Out Button Click to make the drawing size smaller by one step.
Zoom In Button Click to make the drawing size larger by one step.
Zoom drawing to fit on screen Click to fit all of the drawing on the screen.
Pipe Flow Expert offers a choice of a drawing grid with square increments for standard designs or an
isometric grid for use where it is desirable to create an isometric view.
Moving from a standard grid to an isometric grid transposes the standard drawing on to a flat
isometric plane. A user can then adjust/move the nodes as necessary to produce a drawing that
looks 3D.
Moving from an isometric grid to a standard grid transposes the isometric drawing to a flattened view
that produces a near plan view (except that PipeFlow Expert does not allow nodes to appear at the
same point on the grid and therefore nodes directly above or below each other on the isometric grid
are offset at a diagonal angle when transposed to the flat view).
Labelling Tab
Feature Description
Show Name (Pipes) Show name of the pipe on the drawing.
Show Diameter Show diameter of the pipe on the drawing.
Show Length Show length of the pipe on the drawing.
Show Pipe # Show the pipe number on the drawing.
Component Name Show component name on the drawing.
Flow Control Name Show flow control name on the drawing.
Show Values Show valve symbol on the drawing, if valve is present on pipe.
Show Total K Value Show total K value on the drawing, for all fittings on the pipe.
Show Bends Show bend symbol on the drawing, if bend is present on pipe.
Show Pump Name Show pump name on the drawing.
Show Distance on Pipe Show the pump position along pipe on the drawing.
Show Elevation (Pump) Show the pump elevation on the drawing.
Show Name (Node) Show the name of node on the drawing.
Show Elevation (Node) Show the node elevation on the drawing.
Show Tank Info Show the Tank Information on the drawing.
Show Node # Show the pipe number on the drawing.
Pipe Results Show the volume flow rate on drawing.
Show Flow Rate
Show Mass Flow Show the mass flow rate on drawing.
Show Velocity Show the fluid velocity on the drawing.
Show Total Pressure Drop Show the total pressure drop of the pipe, the fittings and the component
on the drawing.
Fitting Results
Do Not Show on drawing Do not show the total pressure drop of the fittings on the drawing.
Show Pressure Loss through
fittings Show the pressure drop of the fittings on the drawing.
Pump Results
Do Not Show on drawing Do not show the pump results data on the drawing.
Show Pump Head Show the pump head on the drawing.
Show NPSH available Show the net positive suction head available at the pump inlet on the
drawing.
Node Results
Do Not Show on drawing Do not show the pressure at the nodes.
Show Pressure at Node Show the pressure at the nodes on the drawing.
OK Confirm changes to configuration options.
Cancel Close the labelling tab without making any changes.
Calculations and Results 51
Units Tab
Feature Description
Length Select the units for display of the pipe lengths.
Diameter Select the units for display of the pipe internal diameters.
Roughness Select the units for display of the pipe internal roughness.
Head Losses Select the units for display of the head losses
Flow Rate Select the units for display of the flow rates.
Mass Flow Select the units for display of the mass flow rates
Velocity Select the units for display of the fluid velocities.
Weight Select the units for display of the pipe weights.
Volume Select the units for display of the internal pipe volumes.
Surface Area Select the units for display of the surface areas of the pipes.
Energy Select the units for display of the energy usage
Tanks, Nodes, Control &
Components:
Pressure Select the units for display of pressure.
Liquid Level Select the units for display of the fluid liquid level.
52 Pipe Flow Expert User Guide
System Results: Select the units for display of the elevations of the nodes.
Elevation
Atmosphere Value of standard atmosphere in absolute pressure units.
Pressure Ref. Select Gage or Absolute pressure units.
Pressure Select the units for display of the pressures at join points (nodes).
Temperature Select option for display of the fluid temperatures.
Density Select the units for display of the fluid density
Imperial or Metric Select general option for Imperial or Metric displays.
OK Confirm changes to configuration options.
Cancel Close the dialog without making any changes.
Calculations and Results 53
NOTE: Be sure to enter the value for the pipe’s properties in the units displayed next to the field. For
example, if you are using metric units, and m for meter is displayed next to the Length field, enter the
pipe length value in meters.
Various attributes of the default pipe may be copied to the list of selected pipes.
The Selection Tool or the Individual Pipe Selection Tool may be used to select
which pipes are to selected prior to opening the Pipe Settings tab. Individual pipes can
be added or removed from the selected list by checking or un-checking the box adjacent to the
pipe description.
Feature Description
Internal Diameter Set the default internal diameter for the next pipe to be added to the
drawing.
Diam? Display the Pipe Diameter Database.
54 Pipe Flow Expert User Guide
Roughness Set the default internal roughness for the next pipe to be added to the
drawing.
Material Display the Pipe Material Database.
Length Set the default pipe length for the next pipe to be added to the drawing.
Add/Change Fittings Select the default fittings for the next pipe to be added to the drawing.
Add/Edit Component Set the default data for a component to be added to the drawing.
Pipe Color Select the pipe color and line width for the default pipe.
Copy Internal Diameter Only Copy the internal diameter data to the pipes selected in the listing.
Copy All Diameter Data Copy the internal and outer diameter data to pipes selected in the listing.
Copy Roughness Only Copy the internal roughness to the pipes selected in the listing.
Copy All Material Data Copy the pipe material, schedule/class and internal roughness to the
pipes selected in the listing.
Copy Length Only Copy the default pipe length to the pipes selected in the listing.
Copy Fittings Only Copy the default pipe fittings to the pipes selected in the listing.
Copy Components Only Copt the default component to the pipes selected in the listing.
Copy Color and Style Copy the line color and line width to the pipes selected in the listing.
Copy All Pipe Data Copy the default pipe values, including fittings and valves, component
and pumps to the pipes selected in the listing.
Open Pipes Open the pipes selected in the listing. Pipes which are currently closed
will be shown at the end of the listing.
Close Pipes Close the pipes selected in the listing.
OK Close the configuration options pipe updates tab.
Calculations and Results 55
Feature Description
Copy Node Elevation Copy the elevation to the nodes selected in the listing.
Copy Node Image Copy the node image to the nodes selected in the listing.
Copy Image and Elevation Copy the node image and the elevation to the nodes selected in the
listing.
Copy Demand – Flow In Copy the additional flow in values entering the system at the node points
selected in the listing.
Copy Demand – Flow Out Copy the additional flow out values leaving the system at the node points
selected in the listing.
OK Close the configuration options node updates tab.
56 Pipe Flow Expert User Guide
Feature Description
Use Design Colors / Select option to display results according to the chosen color gradient.
Use Color Gradient
Determine Results Colors Select a results category to be displayed using the chosen color
based on a Chosen Category. gradient.
Sample Gradients Select a color gradient to be used on the results screen.
Low Color / Middle Color / Select customized colors to generate a user defined color gradient.
High Color
OK Close the results colors tab.
Cancel Close the results colors tab and revert to the previous selection
Calculations and Results 57
Calculations Tab
Feature Description
Pressure Balancing Pressure balance tolerance allowed around a set of pipes forming a
Tolerance (Final) loop, for final solution.
Loop Pressure Balancing Pressure balance tolerance allowed around a set of pipes forming a
Tolerance (Initial) loop, for initial solution.
Flow Balance Final Tolerance Mass flow in and mass flow out tolerance allowed at a node (join point)
Max Iterations for Maximum calculation iterations allowed to find approximate solution.
Approximate Solution
Max Iterations for Final Maximum calculation iterations allowed to find final solution.
Solution
Final Iterations Delta Rate of adjustment during convergence to final solution.
Reduction Factor
Min Velocity for Discharge Starting velocity estimate for unknown discharge estimation.
Estimates
Max Velocity for Discharge Final velocity estimate for unknown discharge estimation.
Estimates
58 Pipe Flow Expert User Guide
Note: We recommend that you do not change these values, unless it becomes necessary to solve a
very finely balanced system.
Calculations and Results 59
Results Tables
The results of a pipeline system analysis are displayed in the Results tables. Data for flow rates in
pipes, velocities in pipes, pressures at join points, tank elevations, hydraulic grade lines, pump
operating points and many more calculated results, can all be viewed in the results tables.
The results table interacts with the drawing pane in a two-way manner. If a pipe or a node is selected
in the results tables then the pipe or node is selected on the drawing.
Click the ‘Zoom To’ button or a double click on the selected result line to zoom the display to
show the selected item in the centre of the drawing area. If a pipe or node is clicked on the
drawing to select it then the results table will also change to show the selected item.
The results display units can be altered by choosing the units required from the configuration options
units tab.
The results information about the elements of your system can be saved to an Excel spreadsheet file
or exported to a new Excel spreadsheet.
Feature Description
File menu Select an option to save results in Excel format or to export the results to
a new Excel spreadsheet.
Units menu Select option to display the results in Imperial, Metric or selected units.
Save button Save the results data in Excel format.
Export to Excel button Start Excel and display the results data in a new Excel spreadsheet.
Choose Units Select option to display the results in Imperial, Metric or selected units.
Pipes tab Display the information about the pipes in the system.
Fittings tab Display the information about the valves and fittings in the system.
Pumps tab Display the information about the pumps in the system.
Nodes tab Display the information about the nodes in the system.
Fluids tab Display the information about the fluids in the system.
Pipe Materials tab Display the information about the pipe materials in the system.
Energy tab Display the information about the energy usage in the system.
All Results tab Display the information about the elements in the system.
Calculations and Results 61
The Results drawing can be configured to display the pipes in various colors based on the value of a
chosen category such as Flow Rate, Velocity, Friction Loss, Internal Diameter etc. The color gradient
start and end point values may be adjusted to narrow the band over which the colors are displayed.
62 Pipe Flow Expert User Guide
Once a system has been created it can then be saved to a system design file which stores all of the
information about the system, including the node and pipe data, the fittings and valve information,
the components information, and the pump data.
Individual items in the system such as components and pumps can also be saved to their own file,
so that they can be re-used and re-loaded as required (perhaps for use in future systems or to
duplicate and copy these items within an existing system). The pump file extension is .pfpm and the
component file extension is .pfco.
Images of the drawing screen can be saved and/or attached to an email as a convenient way of
sharing a quick snapshot of a system or set of results.
1. Define whether imperial or metric units are used throughout the pipe system.
2. To define the imperial or metric setting, select the Imperial or Metric option on the toolbar or
the Units tab in the Configuration Options dialog, or you can select the Imperial or Metric
menu items from the Units menu.
3. You can customize the units and default values used for the individual items in the system at
any time by using the Configuration Options dialog.
4. Click the New Grid button or select File | New to create a new drawing grid.
Calculations and Results 63
5. Pipe Flow Expert asks the user if the grid should be shown for isometric drawing. Click ‘yes’
to display the isometric grid or click ‘no’ to display the standard drawing grid.
After creating a pipe system you should set the preferences of your choice. In Pipe Flow Expert you
can configure whether imperial, metric or specifically chosen units are used throughout the system.
The labelling used on the pipe system drawing can be altered such that specific items can be
selected to be shown or excluded as required.
The configuration settings for a pipe system can be amended at any time, while you are working in a
pipe system, however defining your choices in advance will make it easier when you come to start
the drawing process. All configuration options are saved with the system and will be set to their
saved values when a system is loaded.
Tanks and end-pressure nodes will also be displayed in the isometric plane. The drawing menu
provides options to display an ‘Isometric tank view from the left’ or to display an ‘Isometric tank view
from the right’. Selecting either of these options will change the display of all tanks and end pressure
on the isometric view.
1. Define the pipe system’s fluid and the fluid’s properties. For more information about selecting
a fluid, see: Defining the System Fluid
2. Add the applicable tanks to the system. For more information about adding tanks, see:
Adding a Tank
3. Add the applicable join points to the system. For more information about adding join points,
see: Adding a Node (Join Point)
4. Add the applicable pipes to the system. For more information about adding pipes, see:
Adding a Pipe
5. Add the applicable pumps to the system. For more information about adding pumps, see:
Adding a Pump
6. Add the applicable fittings to the system. For more information about adding fittings, see:
Adding Fittings and Valves
7. Add the applicable component pressure losses to the system. For more information about
adding component pressure losses, see: Adding a Component
8. Add the applicable control valves to the system. Flow Control Valves, Pressure Reducing
Valves or Back Pressure Valves can be used in the system. For more information about
adding control valves, see: Adding a Control Valve
64 Pipe Flow Expert User Guide
9. Add the applicable demand flows to the system. For more information about adding demand
flows, see: Adding a Demand Flow
10. Add the applicable demand pressures to the system. For more information about adding
demand pressures, see: Adding a Demand Pressure
11. Calculate and solve the pipe system’s flow and pressure. For more information about
calculating and solving, see: Calculating and Solving the System
Saving a System
When you save a pipe system in Pipe Flow Expert, a .pfe file is generated that is used exclusively
with Pipe Flow Expert. All the system’s data is stored within the file. If you need to modify the
system, or want to reuse the system for a future system, you can simply open the file in Pipe Flow
Expert, make the necessary changes, and resave the file.
1. Click the Save File button, , on the toolbar or select File | Save to open the Save As
dialog.
Once a pipe system has been saved to a .pfe file, you can simply click the Save button, , on the
toolbar or select File | Save to save changes to the system.
Calculations and Results 65
When an Isometric view is transposed (flattened) to a standard view, any vertical lines from the
isometric view will be drawn at 45 degrees. This happens because Pipe Flow Expert does not allow
a drawing to contain nodes which sit over other nodes, or nodes which sit over pipes.
This restriction has been applied to avoid confusion.
With the ‘Isometric to Standard’ type of transposition the result can be visualized as an offset view
from a high overhead position, where the vertical lines can still be seen, i.e. the result looks similar
to a plan view but it is not an exact plan view (where some of the lines which were vertical in the
isometric view would not be seen in an exact plan view).
When a Standard view is transposed to an Isometric view the result will be a flat view of the current
drawing in the isometric plane. The user may then adjust/move node positions as required to make
the drawing appear 3D on the isometric grid.
3. Select the ‘Drag and Move’ mode and adjust the node positions as required.
4. Use the drawing menu to select ‘Isometric tank View from Right’ or ’Isometric Tank View
from Left’.
1. Click the Email System Information button, , on the toolbar to open a new mail
message in your default e-mail application with the system’s .pfe file attached to the e-
mail.
Printing a System
When you print a pipe system in Pipe Flow Expert, only the visible part of image, what is currently
displayed in the Drawing pane, is printed.
If you wish to print the entire pipe system, click the Zoom Out button, , on the toolbar to zoom
out until the area you wish to print is visible in the Drawing pane.
The printed image will be scaled to fit on one page by default, but you can customize the scaling
using the Scale to fit fields. If you want to change the paper’s orientation to landscape or print to a
printer other than your computer’s default printer, open the Page Setup dialog and make your
66 Pipe Flow Expert User Guide
selections before printing the pipe system. To access the Page Setup dialog, select Print Setup from
the File menu.
As an alternative for larger higher quality prints of your complete system you can create a PDF
image of your system drawing by using the option provided on the file menu.
The PDF drawing can then be printed at a size to suit your requirements.
1. Click the Print button, , on the toolbar or select File | Print to open the Printing
Information dialog.
2. If you want to change the printing scale, type the number of pages wide by the number of
pages high in the Scale to fit fields. Note: Printing over multiple pages requires use of
additional memory and problems may arise if your system (and printer) do not have enough
memory available. The amount of memory required varies considerably depending on the
size and number of items on the drawing that is to printed.
3. Type the title you want displayed at the top of the page.
1. Click on the File Menu and select, , Save Screen as EMF Metafile…
2. Your default email client will be opened with an attached jpeg image named PFEImg.jpg
System Options
Pipe Flow Expert can be configured and set-up to suit the users working preferences.
The labelling on the drawing can be configured so that specific items can be included or excluded as
required. The units in which to display lengths, diameters, head loss, velocity etc. can be chosen.
The details of a default pipe can be chosen and these details will be used to draw any new pipes.
The calculation tolerances can be changed if necessary (however in most cases these values should
be left unchanged).
Most configuration settings are defined in the Configuration Options dialog which is made up of a
series of tabs, one for each page of configuration options.
You can access the Configuration Options dialog by selecting the Specify Units menu
selection from the Units menu, or clicking the Labelling or Units button on the tool bar.
To select a Default Pipe size for drawing click the Pipe button on the tool bar to choose the
pipe material, the pipe diameter and pipe length etc.
NOTE: When you change the universal unit setting, it converts all unit values to the unit type
selected, and all values on the Units tab of the Configuration Options dialog are converted to the
fields’ default values. For example, if you are changing the universal setting from imperial to metric,
all values, including any imperial units selected on the Units tab of the Configuration Options dialog,
are converted to metric. All field values on the Units tab are also reset to their default metric value.
There are three places in Pipe Flow Expert that you can define the universal unit setting.
1. To change the units from the toolbar, click the Imperial or Metric option on the tool bar.
2. To change the units from the Units tab, click the Units, , button on the tool bar or select
Specify Units from the Units menu to open the Units tab of the Configuration Options
screen. Click the Imperial or Metric option.
3. To change the units from the Units menu, select the Imperial Units or Metric Units from
the Configuration Options Units Tab screen.
For more information about pipe system results, see: Calculating the System Flow and Pressure
Click the Labelling button, , on the tool bar to open the Labelling tab of the Configuration
Options screen.
1. Select the check boxes next to the labelling options you want to apply to the pipe system in
the Pipes, Fittings, Pumps, and Nodes sections.
2. Click one of the labelling options in the Pipe Results, Fitting Results, Pump Results and
Node Results sections to determine which of the pipe system’s calculation results are
displayed in the Drawing pane.
3. Click OK to save the labelling configurations and close the Configuration Options dialog, or
click another tab in the dialog to continue configuring Pipe Flow Expert and the pipe system.
4. To remove a labelling option, clear the check box next to the applicable label in the Pipes,
Fittings, Pumps, or Nodes section of the Labelling tab.
70 Pipe Flow Expert User Guide
For example, if you select feet from the Length list in the Pipes section on the Units tab, feet will be
displayed next to the Length field in the Pipe pane, and if the Show Length check box is selected in
the Pipes section of the Labelling tab, each pipe’s length in the pipe system is displayed in feet in the
Drawing pane.
To define the units used in Pipe Flow Expert and the pipe system:
1. Click the Choose Units button, , on the tool bar, or select Specify Units from the Units
menu to open the Units tab of the Configuration Options screen.
3. Do not click the Imperial or Metric option in the Change All Units section of the Units tab,
unless you want to change the universal unit setting and reset all the values currently
defined on the Units tab.
NOTE: When you change the universal unit setting, it converts all unit values to the unit type
selected, and all values on the Units tab of the Configuration Options dialog are converted to the
fields’ default values. For example, if you are changing the universal setting from imperial to metric,
all values, including any imperial units selected on the Units tab of the Configuration Options dialog,
are converted to metric. All field values on the Units tab are also reset to their default metric value.
Calculations and Results 71
Click OK to save the unit configurations and close the Configuration Options dialog, or click another
tab in the dialog to continue configuring Pipe Flow Expert and the pipe system.
The default pipe values are used when adding pipes however you can customize the values for an
individual pipe in the system at any time, by editing its values in the Pipe pane or in the Pipe
diameter data dialog.
NOTE: Be sure to enter the value for the pipe’s properties in the units displayed next to the field. For
example, if you are using metric units, and m for meter is displayed next to the Length field, enter the
pipe length value in meters.
1. Click the Set Default Pipe for drawing button, , on the tool bar to open the Default
Values tab of the Configuration Options dialog.
1. Click the Material button. This opens the Pipe diameter data screen A list of all the pipe
materials available in the pipe database are displayed in the Choose new pipe material list.
72 Pipe Flow Expert User Guide
2. Select the pipe’s material from the Choose new pipe material list.
3. If the pipe material is not in the Choose new pipe material list, click the Add new material
button to add the new material to the list. For more information about adding a pipe material,
see: Adding a Pipe Material to the Database section in Section: Creating a Pipe System.
4. Click the Select button or double-click the row containing the material.
1. The selected material is displayed in the Pipe data section of the Pipe diameter data
dialog, and a list of all the different pipe sizes available for the selected pipe material is
displayed in the Pipe diameter database.
Calculations and Results 73
3. If the pipe size is not in the list, click the Add new size button to add the new size to the list.
For more information about adding a pipe size, see: Adding Pipe Size Data to the Database
Section: Creating a Pipe System.
4. Click the Transfer Selected Size button or double-click the row containing the size. The
selected size is displayed below the pipe material in the Pipe data section of the Pipe
diameter data screen.
5. Edit the applicable pipe properties in the Pipe data section. The edits you make only affects
the pipe’s properties for the system; they do not affect the database data.
6. Click Save Pipe to add the pipe’s material and size, and to close the Pipe diameter
database.
The Pipe Default Tab is now populated with the choices that have been made.
The pipe’s material is displayed under the Roughness field, the nominal size is displayed under the
Diam button and the pipe’s internal diameter and roughness are displayed in the Internal Diameter
and Roughness fields on the Default Values tab.
74 Pipe Flow Expert User Guide
1. Type the default pipe length into the Length field on the pipe pane.
1. The default number of fittings currently on the selected pipe is displayed on the Add/Change
Fittings button.
3. Clicking the Add/Change Fittings button opens the Pipe fitting friction coefficients dialog.
A list of all the fittings available in the fitting database is displayed in the Fitting Database
list.
4. Select the fitting you want to add to the pipe from the Fitting Database list.
5. Use the Move to fitting size fields to locate a specific metric or imperial fitting size in the
Fitting Database list.
6. If the fitting is not in the Fitting Database list, click the Create new fitting button to add the
new fitting to the list. For more information about adding a fitting to the database, see: Adding
a Fitting to the Database section in Section: Creating a Pipe System.
7. Click the Add selection to pipe button or double-click the row containing the fitting.
8. The selected fitting is displayed in the Fittings on section of the Pipe fitting friction
coefficients dialog.
9. Select the quantity of the fitting you are adding to the pipe from the fitting’s Qty list in the
Fittings on section.
Calculations and Results 75
11. Click Save to add the fitting to the pipe, and to close the Pipe fitting friction coefficients
screen.
13. Click OK to save the default pipe values and close the Configuration Options dialog, or
click another tab in the dialog to continue configuring Pipe Flow Expert and the pipe system.
1. Optional: First select a group of pipes to update using the Selection Tool, , or the
2. Click the Adjust Attributes of Selected Pipes button, , on the tool bar, to open the
Pipe Settings tab of the Configuration Options dialog.
3. Individual pipes can be added or removed from the selected list by checking or un-checking
the box adjacent to the pipe description.
4. Click Copy All Pipe Data to copy all of the pipe attributes, including valves and fittings and
the fluid zone to the selected pipes.
76 Pipe Flow Expert User Guide
5. Click Copy All Diameter Data to copy the default internal and external pipe diameter to the
selected pipes.
6. Click Copy Internal Diameter Only to copy the default internal diameter to the selected
pipes.
7. Click Copy All Material Data to copy the default material, schedule/class and internal
roughness to the selected pipes.
8. Click Copy Internal Diameter Only to copy the default internal diameter to the selected
pipes.
9. Click Copy Roughness Only to copy the default internal roughness to the selected pipes.
10. Click Copy Length Only to copy the default pipe length to the selected pipes.
11. Click Copy Fittings Only to copy the default pipe fittings to the selected pipes.
12. Click Copy Components Only to copy the default pipe component to the selected pipes.
13. Click Copy Color and Style to copy the default pipe color and line width to the selected
pipes.
Calculations and Results 77
Node Updates
The node elevation and the node image on the Node Updates Tab may be copied to other nodes in
the system. The Selection Tool or the Individual Item Selection Option may be used to select a
range of nodes on the drawing prior to opening the Node Updates tab.
1. Optional: First select a group of nodes to update using the Selection Tool, , or the
2. Click the Adjust Attributes of Selected Nodes button, , on the tool bar, to open the
Node Updates tab of the Configuration Options screen.
3. Individual nodes can be added or removed from the selected list by checking or un-checking
the box adjacent to the node description.
4. Click Copy Node Elevation to copy the node elevation to the selected nodes.
5. Click Copy Node Image to copy the node image to the selected nodes.
6. Click Copy Image and Elevation to copy the node image and the node elevation to the
selected nodes.
7. Click Copy Demand – Flow In to copy the flow in values to the selected nodes.
8. Click Copy Demand – Flow Out to copy the flow out values to the selected nodes.
78 Pipe Flow Expert User Guide
Results Colors
The results screen can display pipes and nodes from the solved network using a color gradient to
highlight the pipes or nodes based on the result value for a chosen calculation category.
1. Click the Color button, , on Results Screen Color Key, to open the Results Colors tab
of the Configuration Options screen.
3. Choose a color gradient from the drop down of sample gradients, or use the Low, Middle
and High color buttons to create your own color gradient.
Most systems can be solved without any changes to the Calculation options, however these options
are included for experimental use when a balanced solution cannot be found. Widening of these
parameters may give results where the flow into the system and out of the system do not balance
and/or the pressure results throughout the system will not agree with the sum of the pressure drops
through the individual pipes.
A balanced solution may not always be found if the system contains components which ‘fight’ each
other. If a pump is placed in a pipeline, the resultant effect of a change in flow rate will be the sum of
the pipeline friction and the head added by the pump. In some circumstances where a system
includes a number of pumps, the adjustment of the flow rate in one pipe/pump combination will allow
a disproportionate change in the flow rate in another pipe/pump combination, which might have a
counter acting effect to the previous flow rate adjustment. Thus the program would oscillate between
two possible solutions, neither of which will give a normally expected degree of accuracy.
It would normally be better to change the system design to overcome these sorts of problem rather
than proceed with a design where it is difficult to predict an accurate result.
Note: We recommend that you do not change these values, unless it becomes necessary to solve a
finally balanced system.
The following adjustments can be made (but the user is advised to leave these values
unchanged):
80 Pipe Flow Expert User Guide
Feature Description
Loop Balance Final Pressure Pressure balance tolerance allowed around a loop, for final solution.
Tolerance
Loop Balance Initial Pressure Pressure balance tolerance allowed around a loop, for initial solution.
Tolerance
Flow Balancing Tolerance Flow in and flow out difference allowed at join points.
Final Solution Verification Pressure balance accuracy tolerance allowed between adjoining
nodes.
Max Iterations for Maximum calculation iterations allowed to find initial approximate
Approximate Solution solution.
Max Iterations for Final Maximum calculation iterations allowed to find final solution.
Solution
Final Iterations Delta Rate of delta reduction adjustments to find final solution.
Reduction Factor
Min Velocity for Discharge Starting velocity estimate for unknown discharge estimation.
Estimates
Max Velocity for Discharge Maximum velocity estimate allowed for unknown discharge estimation.
Estimates
Calculation Warning NPSHa < NPSHr plus percentage allowance.
Parameters If NPSHa is less than NPSHr plus a percentage allowance a warning
is issued in the results log.
Liquid Velocity > If the liquid velocity in a pipe exceeds the set value a warning is issued
in the results log.
Gas Velocity > If the gas velocity in a pipe exceeds the set value a warning is issued
in the results log.
Gas Fluid Density within If the gas fluid density within an individual fluid zone differs from the
Zones Avg Gas Density average gas density by more than the percentage allowance a
warning is issued in the results log.
Reset All entries to the Restore the standard settings for the calculation parameters.
Default Values
OK Confirm changes to system calculation options.
Cancel Close the Calculations Tab without making any changes.
Calculations and Results 81
Fluid Zones
Pipe Flow Expert will allow the user to design pipeline systems with up to 20 different fluid zones.
The density and viscosity of each fluid zone must be set by the user. Pipe Flow Expert does not
calculate the resultant density or viscosity of any 'mixed' fluids.
Each pipe in a system can be associated with an available fluid zone. The density and viscosity of
the associated fluid zone will be used in calculating the flow rate and pressure loss in each pipe.
Most systems may only have one Fluid Zone, therefore when a new system is being drawn each
new pipe will be associated with the fluid zone associated with the default pipe data.
Fluid Zone 1 is the Default Fluid Zone. The color of Fluid Zone 1 cannot be changed. Pipes in the
default fluid zone are not background highlighted.
Pipes associated with Fluid Zone 2 to Fluid Zone 20 are background highlighted to assist with
identification of the different fluid zones. The background highlight color for these fluid zones can be
amended by the user. This background highlighting may be toggled on/off from a fluid menu option.
Changing the fluid data of a fluid zone will affect the calculation of flow and pressure loss for all pipes
associated with the fluid zone.
Feature Description
Change Fluid Change the fluid name, density and viscosity for the currently selected
fluid zone.
Create New Fluid Zone Create a new fluid zone. The fluid database screen will be displayed
so that new fluid data can be selected. When the fluid data has been
chosen / amended click save to confirm the data for the new fluid
zone.
Delete Current Fluid Zone Delete the currently selected fluid zone.
Change Color for this fluid Change the background highlight color for the currently selected fluid
zone zone
82 Pipe Flow Expert User Guide
Select / Add pipes to this fluid Select pipes to be associated with the currently selected fluid zone.
zone The drawing cursor will change to a Fluid Zone selection rectangle.
Move the drawing cursor to an appropriate position on the system
drawing. Click on the drawing pane and hold the mouse button down
while dragging the Fluid Zone selection rectangle to enclose the pipes
to be associated with current fluid zone. When the mouse button is
released the enclosed pipes will be associated with the current fluid
zone.
On / Off Show Colors for Toggle the fluid zone background highlight colors display on / off.
Fluid Zones
Reset Fluid Zone to Default Reset all fluid zone colors to the default color for each fluid zone.
Colors
Close Close the fluid menu.
Fluids Database
Pipe Flow Expert includes a fluid database. The Fluid Properties Database list on the Fluid data
screen displays all fluids available in the fluid database. When you are selecting a fluid to be used in
the currently selected fluid zone you can select an existing fluid, or add a new fluid by adding the
fluid to the fluid database.
The Fluid Data can be defined and overwritten in the fluid properties section of the Fluid data screen.
New fluid data can be added to the existing database entries by using the Add New Fluid button.
To define the fluid and fluid properties for the currently selected fluid zone:
1. Click the Fluid button, , on the tool bar and select ‘Change Fluid’ from the pop-up
menu to open the Fluid data dialog.
2. Select the fluid contained in the pipe system from the Fluid Properties Database list.
3. If the fluid is not in the Fluid Properties Database list, click the Add new fluid data button to
add the new fluid data to the list. For more information about adding fluid data, see: Adding
Fluids to the Fluid Database
4. Click the Use selected fluid button or double-click the row containing the fluid.
5. The selected fluid is displayed in the Fluid properties section of the Fluid data dialog.
7. The edits you make only affect the fluid properties for the system; they do not affect the
database data.
8. Click Save to save the fluid data to be used with the currently selected fluid zone.
The name of the fluid for the currently selected fluid zone is displayed next to the Fluid button on the
tool bar.
NOTE: Be sure to enter the value for the fluid’s properties in the units displayed on the column
header. For example, if you are using imperial units, ºF for Fahrenheit is displayed under
Temperature in the Temperature column. The temperature value should be entered in degrees
Fahrenheit.
1. Click the Fluid button, , on the tool bar and select ‘Change Fluid’ from the pop-up
menu to open the Fluid database.
3. Clicking the Add new fluid data button opens the Add fluid data section in the Fluid data
screen.
10. If the fluid’s state is gas, select the Gas check box in the State field.
11. Leave the Gas check box blank if the fluid’s state is liquid.
12. Click Save to save the new fluid data to the database and the Fluid Properties Database
list.
Calculations and Results 85
1. Click the Fluid data button, , on the tool bar and select ‘Change Fluid’ from the pop-
up menu to open the Fluid Data dialog.
2. Choose the All Fluids or Gases option to display the Calculate Gas Data button.
3. Click the Calculate Gas Data button to display the Properties of Gases calculator.
7. The viscosity and density data for the gas are displayed.
8. Click Add new entry to add the data to the fluid data list.
86 Pipe Flow Expert User Guide
Tanks
In Pipe Flow Expert, a tank can represent a reservoir or any type of fluid supply. It can also model a
discharge or the point where a fluid exits a pipe system. A tank is a type of node in Pipe Flow Expert.
There are three types of nodes used in a pipe system: tanks, demand pressures, and join points.
Nodes are located at the beginning and end of a pipe.
NOTE: Be sure to enter the values for the tank’s properties in the units displayed next to the field.
For example, if you are using imperial units, and ft for feet is displayed next to the Liquid Level field,
enter the liquid level value in feet.
Add a Tank
To add a tank to the pipe system:
2. When you click the Add Tank button, the tank symbol is displayed next to your mouse
pointer when the pointer is in the Drawing pane.
3. Click on the place on the Drawing pane where you want to add a tank.
4. The tank is added to the system, and is selected on the Drawing pane. Define the tank’s
properties in the Node pane.
7. Click the Tank Icon button to select the tank image you want displayed on the pipe system
drawing. The icon size can be selected from a range of scales. The image you select does not affect
any of the tank’s properties or values.
8. Type the surface pressure of the fluid in the tank in the Surface Pressure field.
9. Type the amount of fluid above the tank exit point in the Liquid Level field.
10. Type the exit elevation from the tank in the Elevation (Exit) field.
11. Type any applicable notes regarding the tank in the Notes field.
Once join points are added, you can define the fitting(s) used at each join point and the other fittings
along the pipes in the pipe system.
NOTE: Be sure to enter the values for the join point’s properties in the units displayed next to the
field. For example, if you are using imperial units, and ft for feet is displayed next to the Elevation of
Join field, enter the elevation in feet.
Adding a Node
To add a join point node to the pipe system:
2. When you click the Add Join Point button, the join point symbol is displayed next to your
mouse pointer when the pointer is in the Drawing pane.
3. Click on the place on the Drawing pane where you want to add a join point.
4. The join point is added to the system, and is selected on the Drawing pane. Define the join
point’s name, elevation, and volume demand in and/or demand out in the Node pane.
7. Type the elevation of the join point in the Elevation of Join field
8. If the system has a required demand flow at the join point, click the Edit button to open the
Set Flow Demands screen.
9. You can enter either an In-Flow or an Out-Flow demand at the join point on the Set Flow
Demands screen. Both Edit buttons in the Node pane open the Set Flow Demands screen.
10. Type the required flow rate for the fluid entering the system at the join point in the In Flow
field. (Usually the out flow field should be set at zero).
11. Type the required flow rate for the fluid leaving the system at the join point in the Out Flow
field. (Usually the in flow field should be set at zero).
13. Type any applicable notes regarding the join point in the Notes field.
14. To add additional join points to the system, repeat Steps 3 – 12.
90 Pipe Flow Expert User Guide
Pipes
If you will be using the same type of pipe throughout the pipe system, you can define the default pipe
type and values for the system using the Default Values tab in the Configuration Options dialog.
When the default pipe values are set, each time you add a pipe to the system, the pipe type and
values are automatically defined for the pipe. You can customize the values for an individual pipe in
the system, by editing its values in the Pipe pane or in the Pipe diameter data dialog. The Pipe
diameter data dialog contains a list of the pipe materials and sizes available in the pipe database and
additional properties specific to a pipe in the system.
For more information about using default pipe values, see: Setting Up the System Options
NOTE: Be sure to enter the values for the pipe’s properties in the units displayed next to the field.
For example, if you are using metric units, and m for meter is displayed next to the Length field, enter
the pipe length value in meters.
Adding a Pipe
To add a pipe to the pipe system:
2. When you click the Add Pipes button, the pipe symbol is displayed next to your mouse
pointer when the pointer is in the Drawing pane.
3. Click on the place on the Drawing pane where you want the pipe to start.
5. The pipe is added to the system, and is selected in the Drawing pane. Define the pipe’s
properties in the Pipe Pane.
6. The rubber-banding functionality of the Add Pipes feature provides the ability to continue
drawing additional connected sections of pipe after adding a section of pipe.
7. If you want to continue adding connected lengths of pipe to the system, move the mouse
pointer to draw the pipe, and click where you want the pipes to end. To turn off the rubber-
banding, press the right mouse button (right-click).
9. If the default pipe type and values for the system are defined on the Default Values tab in
the Configuration Options dialog, you are done adding the pipe.
10. The pipe type, default length, internal diameter and roughness values are displayed in the
Pipe pane.
11. If the default pipe values are not being used for the pipe, continue with Steps 12 to 25.
12. Type the length of the pipe into the Length field.
14. Clicking the Material button opens the Pipe diameter database. A list of all the pipe
materials available in the pipe database are displayed in the Choose new pipe material list.
15. Select the pipe’s material from the Choose new pipe material list.
16. If the pipe material is not in the Choose new pipe material list, click the Add new material
button to add the new material to the list. For more information about adding a pipe material,
see: Adding a Pipe Material to the Database
17. Click the Select button or double-click the row containing the material.
18. The selected material is displayed in the Pipe data section of the Pipe diameter data dialog,
and a list of all the different pipe sizes available for the selected pipe material is displayed in
the Pipe diameter data dialog.
92 Pipe Flow Expert User Guide
20. If the pipe size is not in the list, click the Add new size button to add the new size to the list.
For more information about adding a pipe size, see: Adding Pipe Size Data to the Database
21. Click the Transfer Selected Size button or double-click the row containing the size.
22. The selected size is displayed below the pipe material in the Pipe data section of the Pipe
diameter data screen.
23. Edit the applicable pipe properties in the Pipe data section.
24. The edits made only affect the current pipe’s properties; they do not affect the database data.
25. Click Save Pipe to add the pipe’s material and size, and to close the Pipe diameter data
screen.
The pipe’s material is displayed under the Roughness field, the nominal size is displayed under the
Diam button, and the pipe’s length, internal diameter, and roughness are displayed in the Length,
Internal Diameter, and Roughness fields in the Pipe pane.
Calculations and Results 93
NOTE: Be sure to enter the values for the pipe material’s properties in the units displayed next to the
field. For example, if you are using metric units, and mm for millimeter is displayed next to the
Internal Roughness field, enter the internal surface roughness in millimeters.
1. Select a pipe in the pipe system and click the Material button in the Pipe pane, or click the
Material button on the Default Values tab in the Configuration Options screen to open the
Pipe diameter database with the material list displayed.
3. Clicking the Add new material button opens the Add pipe material section in the Pipe
diameter data screen.
6. Type the material’s internal roughness, expressed in the units displayed in parenthesis, in the
Internal Roughness field.
7. Click the Add new material entry button to save the new material data to the database and
the materials list.
NOTE: Be sure to enter the value for the pipe’s size data in the units displayed on the column
header. For example, if you are using imperial units, and lbs/ft for pounds per foot is displayed under
Weight in the Weight column, the weight value should be entered in pounds per foot.
1. Select a pipe in the pipe system and click the Diam? button in the Pipe pane, or click the
Diam? button on the Default Values tab in the Configuration Options dialog to open the
Pipe diameter data dialog with the size list displayed.
3. Clicking the Add new size button opens the Add pipe data section in the Pipe diameter
data dialog.
4. The pipe’s nominal size will be automatically calculated from the pipe outside diameter data
and the type of material selected. If the user prefers the Nominal Size field can be selected
from the drop down list of nominal pipe sizes.
94 Pipe Flow Expert User Guide
6. Type the wall thickness of the pipe in the Wall Thick. field.
7. Type the outside diameter of the pipe in the Outside Diam. field.
9. The values in the Internal Vol. and Surface Area fields are automatically calculated.
10. Click the Add new entry button to save the new size data to the database size list.
The direction of a selected pipe can also be reversed by using the ‘More’ button on the pipe pane to
display the Pipe Sub-menu options.
1. Click the Open/Close Pipe button, , on the tool bar to select open/close pipe mode.
2. Click any pipe in the Drawing pane which you want to close. The pipe will be closed.
3. To re-open a pipe, click a closed pipe with the Open/Close cursor. The pipe will be re-
opened.
4. Click the Show Item Info button, , or right click to exit the Open/Close pipe direction
mode.
A selected pipe can also be opened or closed by using the Pipe Sub-menu option.
A Closed pipe will be displayed ‘grayed out’ and ‘dotted’ on the drawing to indicate that the pipe is no
longer part on the functioning system. Note: care must be taken with this feature, as a non-functional
system may result from this action and Pipe Flow Expert may not be able analyze the resulting
network.
Calculations and Results 95
Select a pipe and click the right mouse button to display the Pipe Sub-menu.
Select the option that you required and click to perform the action.
Feature Description
Change Pipe Diameter Opens the pipe diameter data – pipe sizes (for current material).
Change Pipe Material Opens the pipe diameter data – materials list.
Add / Edit Fittings Opens the pipe fittings friction coefficients screen.
Add/ Edit Component Loss Opens the component pressure loss screen.
Add / Edit Control Valve Opens the control valve data screen.
Add / Edit Pump Opens the pump data screen.
Re-Open / Close Pipe Open a closed pipe / Close a pipe.
Reverse Pipe Direction Reverse the flow direction of a pipe.
Prevent Backflow – On / Off Tag a pipe to prevent backflow.
Move / Unlink end of pipe Unlink the end of the pipe and allow re-positioning
Use Pipe Valves for Drawing Use the selected pipe data as the default pipe for drawing new pipes.
Change Fluid Zone Change the fluid zone associated with the pipe.
Close Close the pipe sub-menu.
96 Pipe Flow Expert User Guide
When solving a system if backflow occurs in the pipe the flow rate will be set to zero.
Use the pipe sub-menu option to toggle the status of pipes tagged with the prevent backflow symbol.
1. Select a pipe and click the right mouse button to display the Pipe Sub-menu.
To draw a pipe with different attributes, select another pipe that has the attributes that you require
and then set that pipe’s attributes as the default for pipe drawing.
Alternatively use the Set Default Pipe for drawing button on the tool bar to open the pipe
default values on the Configuration Options – Pipe Settings Tab. Choose the pipe material,
diameter and length to be used to draw default pipes.
Calculations and Results 97
If you are adding a fitting near a pump, be sure to consider the orientation of the fitting (whether the
fitting is in front of or after the pump). The orientation of the fitting affects the NPSHa (Net Positive
Suction Head available) value at the pump inlet. If the fitting is placed after the pump, the NPSHa
value at the pump inlet will be higher. If you need to move a fitting, you can move the fitting in the
Drawing pane by clicking the Drag and Move Items button on the tool bar and selecting and moving
the fitting to a new location in the system.
NOTE: Be sure to choose a fitting size that matches the size of the pipe or valve size that is equal or
greater than the size of the pipe. For example, if you are using 4” nominal pipe size select either a
100 mm or a 4 inch fitting.
1. You can add a fitting using the Add Fittings button on the tool bar or the Add/Change
Fittings button in the Pipe Pane.
2. To add a fitting using the Add Fittings tool bar button, click the Add Fittings button, .
3. When you click the Add Fittings button, the fittings symbol is displayed next to your mouse
pointer when the pointer is in the Drawing pane
4. Click on the pipe on the Drawing pane where you want to add a fitting.
5. Clicking on the pipe opens the Pipe fitting friction coefficients screen with a list of all the
fittings available in the fitting database displayed in the Fitting Database list.
6. To add a fitting using the Add/Change Fittings button in the Pipe pane, select the pipe to
which you want to add a fitting in the Drawing pane.
9. The number of fittings currently on the selected pipe is displayed on the Add/Change
Fittings button. Clicking the Add/Change Fittings button opens the Pipe fitting friction
coefficients dialog with a list of all the fittings available in the fitting database displayed in the
Fitting Database list.
98 Pipe Flow Expert User Guide
10. Select the nominal metric or imperial pipe size from the drop down listings to move to the
required fitting sizes in the Fitting Database list. Click on the Pipe Size link to show fitting
which match the current pipe size.
11. If the fitting is not in the Fitting Database list, click the Create new fitting button to add the
new fitting to the list. For more information about adding a fitting to the database, see: Adding
a Fitting to the Database
13. The selected fitting is displayed in the Fittings on section of the Pipe fitting friction
coefficients screen.
14. Select the quantity of the fitting you are adding to the pipe from the fitting’s Qty list in the
Fittings on section.
16. Click Save to add the fitting to the pipe, and to close the Pipe fitting friction coefficients
screen.
When one or more fittings are added to a pipe, the Include check box, , is displayed and
selected next to the Add/Change Fittings button. When the Include check box is selected, Pipe
Flow Expert includes the data from the fittings on the pipe in the calculations for solving the pipe
system.
To remove the fittings’ data from the calculations, clear the Include check box.
Information about calculating and solving pipe systems is available in Section: Calculating the
System Flow and Pressure.
Calculations and Results 99
Adding a fitting involves selecting a fitting from the fitting database or selecting one of the buttons
that represent the fitting from the Calculated K value section, customizing the data to match the new
fitting and calculating the fitting’s K value.
A K value represents a local loss coefficient. This value is supplied by the fitting manufacturer. Most
fittings have a fixed K value, but some fittings have a K value that needs to be calculated. The
Calculated K value section in the Pipe fitting friction coefficients dialog is used to add fittings with a
calculated K value to a pipe system and the fitting database. When you click a fitting button in the
Calculated K value section, a dialog opens that contains fields for adding the fitting measurements
required to calculate the fitting’s K value.
To add a fitting to the fitting database using the Create new fitting button:
2. Click on a fitting symbol in the Drawing pane to open the Pipe fitting friction coefficients
screen.
OR
Select the pipe for which you want to create a new fitting in the Drawing pane, and click the
Add/Change Fittings button, , in the Pipe pane to open the Pipe fitting friction coefficients
screen.
Then
Clicking the Create new fitting button opens the Create new fitting section in the Pipe fitting friction
coefficients screen.
100 Pipe Flow Expert User Guide
2. To change the symbol representing the fitting, click the Change button to open the Choose
symbol screen.
4. Click OK to add the symbol to the Symbol field and close the Choose symbol screen.
6. Select the fitting’s metric size from the Metric list or select the fitting’s imperial size from the
drop down nominal size listings.
Calculations and Results 101
7. You only need to select the metric or imperial fitting size. Pipe Flow Expert automatically
populates the other size for you. For example, if you select 32 mm from the Metric list, the
imperial equivalent, 1-1/4”, automatically appears in the Imperial field.
9. Click the Save this fitting data to list button to add the fitting to the Fitting Database list.
10. If you want to add the fitting to the pipe, as well as the fitting database, click the Add this
fitting to pipe button to add the new fitting to the pipe.
11. The new fitting is displayed in the Fittings on section of the Pipe fitting friction coefficients
screen.
12. Select the quantity of the fitting you are adding to the pipe from the fitting’s Qty list in the
Fittings on section.
13. Click Save to add the fitting to the pipe, and to close the Pipe fitting friction coefficients
screen.
2. Select a fitting in the Drawing pane to open the Pipe fitting friction coefficients screen.
Or
3. Select the pipe for which you want to create a new fitting in the Drawing pane, and click the
Add/Change Fittings button, , in the Pipe pane to open the Pipe fitting friction
coefficients screen.
4. Click the Calculate K value button that represents the fitting you are adding.
Clicking one of the Calculate K value buttons opens the Create new fitting section in the Pipe
fitting friction coefficients screen, and the K value calculation screen for the selected button.
For example, if you selected the sudden contraction button, the Sudden contraction K value
calculation screen opens.
102 Pipe Flow Expert User Guide
8. When you have the desired K value, click the Create new fitting button to close the K value
calculation screen, and add the calculated K value to the K value field in the Create new
fitting section in the Pipe fitting friction coefficients dialog.
9. The Symbol field defaults to the symbol on the Calculated K value button you selected.
10. To change the symbol representing the fitting, click the Change button to open the Choose
symbol screen.
11. Select the symbol you want to represent the fitting. Click OK to add the symbol to the
Symbol field and close the Choose symbol screen
12. The Type field defaults to the type of fitting associated with the Calculated K value button
selected.
13. To edit the fitting type, type the fitting type name in the Type field.
14. The Metric and Imperial fields default to N/A for fittings with a calculated K value. The user
can select the nominal metric or imperial pipe size from the drop down listings if appropriate.
16. Click the Save this fitting data to list button to add the fitting to the fitting database and
Fitting Database list.
If you want to add the fitting to the pipe, instead of the fitting database:
Click the Add this fitting to pipe button to add the new fitting to the pipe.
The new fitting is displayed in the Fittings on section of the Pipe fitting friction coefficients
screen.
Calculations and Results 103
1. Select the quantity of the fitting you are adding to the pipe from the fitting’s Qty list in the
Fittings on section.
2. Click Save to add the fitting to the pipe, and to close the Pipe fitting friction coefficients
dialog.
Components
Certain components, such as strainers, boilers, heat exchanges, manifolds etc. cause a pressure
loss in a system. In Pipe Flow Expert you can enter two types of pressure loss for components –
fixed pressure loss or pressure loss specified by a data curve. Pressure loss for components are
entered and maintained on the Set Component Pressure Loss screen.
The pressure loss defined for a component can be saved to a .pfco file. This file provides a way to
share the pressure loss data for a component, and quickly enter the pressure loss data when the
same type of component is used again in the pipe system or a future pipe system. The .pfco file also
provides a quick and easy way to evaluate different components with pressure loss in the pipe
system to determine how each one affects the system.
Currently in Pipe Flow Expert, you can only add one component pressure loss to each pipe. If there
is more than one component on a pipe that causes a pressure loss, you can break up the applicable
pipe into the number of pieces corresponding with the number of components causing a pressure
loss.
For example, if you have a pipe that is 100 feet long with two components causing a pressure loss,
you can break the pipe into two pieces, each 50 feet long, and add one of the component pressure
losses to each piece. How you divide a pipe does not matter, only the total length of the pieces
added together matters – so that if the pipe is supposed to be 100 feet long, then the lengths of the
pieces need to add up to 100 feet.
NOTE: Be sure to enter the value for the pressure loss properties in the units displayed next to the
field. For example, if you are using imperial units, and psi.g for pounds per square inch is displayed
next to the Fixed Loss field, enter the value in pounds per square inch.
1. You can add the pressure loss using the Add Component Pressure Loss button on the
toolbar or the Add/Change Component Pressure Loss button in the Pipe Pane.
2. To add a pressure loss using the Add Component Pressure Loss tool bar button, click
3. When you click the Add Component Pressure Loss button, the pressure loss symbol is
displayed next to your mouse pointer when the pointer is in the Drawing pane.
4. Click on the pipe on the Drawing pane where you want to add a component pressure
loss.
5. Clicking on the pipe opens the Set Component Pressure Loss dialog.
104 Pipe Flow Expert User Guide
6. To add a pressure loss using the Add/Change Component Pressure Loss button in the
Pipe pane, select the pipe to which you want to add a pressure loss in the Drawing pane.
9. The number of component pressure losses currently on the selected pipe is displayed on
the Add/Change Component Pressure Loss button. Clicking the Add/Change
Component Pressure Loss button opens the Set Component Pressure Loss dialog.
10. To add a component’s pressure loss data from an existing .pfco file, click the Load From
File button, select the applicable .pfco file, click Open, edit the applicable fields, and then
click the OK button.
11. Type the name of the component pressure loss in the Component Name field.
12. Select the Fixed Loss option, if the component’s pressure loss is a fixed pressure loss,
and type the fixed pressure loss value.
Calculations and Results 105
13. Select the Curve Loss option, if the component’s pressure loss is based on a data curve.
14. Select Cv or Kv if the component flow versus pressure loss can is defined in this manner,
and type the appropriate value. See the next section about Cv and Kv values for
specific information about entering and using this type of data.
15. Click the Pressure Loss Scroll Up or Scroll Down button to select the component
pressure loss image you want displayed on the pipe system drawing.
16. The image you select does not affect any of the component’s pressure loss properties or
values.
17. Select the applicable units for the component pressure loss curve from the Curve Loss
flow and head lists.
18. The left Curve Loss column represents the fluid’s flow values, and the right Curve Loss
column represents the fluid head or pressure loss values.
19. Determine which points in the component’s pressure loss data curve, provided by the
component manufacturer, that you want to include in the component’s pressure loss
curve, and type the flow and head values for each of these points in the Curve Loss
table.
20. Add a minimum of three and maximum of eight points in the Curve Loss table. After
adding three curve points to the table, you can have Pipe Flow Expert calculate the
remaining points by clicking the Generate Curve button.
21. Click OK to save and add the component pressure loss data to the pipe.
The pressure loss data you enter can be saved to a .pfco file by clicking the Save To File button. By
saving the data to a .pfco file, you can reuse the component’s pressure loss data for other pipes in
the pipe system or future pipe systems.
When a component pressure loss is added to a pipe, the Include check box is displayed and
selected next to the Add/Change Component Pressure Loss button, . When the Include
check box is selected, Pipe Flow Expert includes the data from the component pressure loss on the
pipe in the calculations for solving the pipe system. To remove the component pressure loss data
from the calculations, clear the Include check box.
Information about calculating and solving pipe systems is available in Section: Calculating the
System Flow and Pressure.
106 Pipe Flow Expert User Guide
A Cv flow coefficient specifies the volume of water in US gpm at 60°F (15.55°C) that will flow through
a valve with a 1.0 psi pressure drop across the valve.
Thus a Cv flow coefficient of 10 indicates that a 1.0 psi pressure drop will occur with a flow of 10 US
gpm of water through the valve. Pressure drop for the different fluids and different flow rates can be
calculated from the Cv flow coefficient. See ‘Calculation Theory and Methods of Solution’ section for
further details.
3
A Kv flow coefficient specifies the volume of water in m /hour at 20°C (68 °F) that will flow through a
valve with a 1.0 bar pressure drop across the valve.
Thus a Kv flow coefficient of 10 indicates that a 1.0 bar pressure drop will occur with a flow of
3
10m /hour of water through the valve. Pressure drop for the different fluids and different flow rates
can be calculated from the Kv flow coefficient. See ‘Calculation Theory and Methods of Solution’
section for further details.
The component object is used to model the flow rate / pressure loss of control valves with Cv or Kv
flow coefficients.
The user should be aware that the Cv or Kv flow coefficient specifies the flow rate of water for a
particular pressure loss.
When the fluid density is greater or less than water, a different flow rate of the fluid will be required to
produce a 1.00 psi or a 1 bar pressure loss through the valve.
CAUTIONS:
If the fluid is a gas, the flow rate entered into the calculator must represent the actual flow rate for the
compressed gas condition, i.e. the volumetric flow rate of the gas based on the gas density defined
in the current fluid. Generally it would be better to use a mass flow rate entry for the calculation
instead of a volumetric flow rate.
If the fluid is a gas and the pressure drop exceeds 50% of the inlet pressure to the valve, the flow
will become choked and it will not be possible to achieve the calculated flow rate. If this
occurs, Pipe Flow Expert will warn of a problem in the Result Log.
Pipe Flow Expert does not model changes in the gas characteristics due to changes in pressure or
temperature. It uses the density and viscosity of the gas as defined in the current fluid. See section
on Working With Compressible Fluids for more information.
Important Note:
To correctly model the pressure drop for the entered Cv or Kv value the density of the gas used in
the calculation must be the density of the gas at the outlet of the valve/component.
In effect this means that the fluid data for the fluid zone associated with the pipe where the
component with a Cv or Kv value is, must be defined for the approximate pressure condition at the
outlet of the valve/component, i.e. specify the current fluid data so that the density represents the
approximate density of the gas at the outlet of the component after the additional pressure drop.
Pipe Flow Expert will calculate the pressure drop through the component/valve for a particular flow at
a given density (as defined by the current fluid zone) based on its Cv or Kv flow coefficient value.
If the fluid zone associated with the control valve does not represent the pressure condition at the
outlet of the valve/component, it may be necessary to use an adjusted Cv (or Kv) value for valve
selection to take in to account the effect of the gas expansion.
The adjusted Cv (or Kv) value should be based on the Cv or Kv formula for sub critical gas pressure
drop.
See ‘Calculation Theory and Methods of Solution’ section for further details about Cv and Kv flow
coefficient calculations for systems where the fluid is a gas.
The Cv (or Kv) flow coefficient of a component/valve is usually stated for the fully open flow
condition. The Cv (or Kv) flow coefficient will be less when the valve is partly closed. In an actual
system it is important to select a control valve which has an appropriate Cv or Kv flow coefficient for
the actual valve position that will be used.
A control valve that is too small or too large will not be able to provide the correct control
characteristics in a pipe system.
Most control valve manufactures recommend that you should select a valve where the required Cv
(or Kv) value matches the given valve Cv (or Kv) value when operating within 20% - 80% of the
valve’s range.
108 Pipe Flow Expert User Guide
When selecting a valve to control a ‘top end’ pressure loss you should select a valve where the
required Cv (or Kv) value is in the higher operating range of the valve, normally where the required
Cv (or Kv) value matches the given valve Cv (or Kv) value when operating at about 70% of the
valve’s range.
Some control valve manufactures recommend that an allowance of 30% should be added to the
required Cv (or Kv) flow coefficient to obtain the minimum Cv (or Kv) flow coefficient rating that the
selected valve should have.
Please check your control valve selection with the control valve manufacturer.
Calculations and Results 109
• A flow control valve (FCV) determines the required flow rate for the fluid in a pipe.
• A pressure reducing valve (PRV) controls the pressure at the end of a pipe.
• A back pressure valve (BPV) controls the pressure at the start of a pipe.
The modeling of Flow Control Valves, Pressure Reducing Valves and Back Pressure Valves requires
that the flow rates and pressures from adjacent pipes must be used as a reference to establish the
pressure loss that control valve must introduce.
To allow this modeling a control valve cannot be added to any pipe where a joining pipe already
includes a control valve.
1. You can add a flow control using the Add Control Valve button on the tool bar or the
Add/Change Control Valve button in the Pipe Pane.
2. To add a control valve using the Add Control Valve tool bar button, click the Add Control
Valve button, .
3. When you click the Add Control Valve button, the control valve symbol is displayed next to
your mouse pointer when the pointer is in the Drawing pane.
4. Click on the pipe on the Drawing pane where you want to add a control valve.
6. To add a flow control using the Add/Change Control Valve button in the Pipe pane, select
the pipe to which you want to add a control valve in the Drawing pane.
9. If there is a control valve currently on the selected pipe a number 1 is displayed on the
Add/Change Control Valve button. Clicking the Add/Change Control Valve button opens
the Set Control Data screen.
110 Pipe Flow Expert User Guide
10. Select the type of control valve to be added (FCV, PRV or BPV) by clicking one of the radio
buttons.
11. The screen will change to allow the entry of data for the type of valve selected.
12. Enter the appropriate data for the control valve type.
13. If you wish to enter an allowable differential pressure range for the valve operation click the
check box and enter the ‘From’ and ‘To’ pressure values. When the system is solved a
warning will be issued if the differential pressure across the control valve is outside the
entered range.
When a control valve of any type is added to a pipe, the Include check box is displayed
and selected next to the Add/Change Flow Control button.
When the Include check box is selected, Pipe Flow Expert includes the data from the flow controls
on the pipe in the calculations for solving the pipe system. To remove the flow control data from the
calculations, clear the Include check box.
Information about calculating and solving pipe systems is available in Section: Calculating the
System Flow and Pressure.
1. Open the Set Control Data dialog as described in the previous section.
3. Type the name of the flow control valve in the Control Name field.
Calculations and Results 111
4. Select the appropriate units of flow from the drop down list.
5. Type the required flow rate for the fluid in the pipe in the Set Flow field.
6. Enter the allowable differential pressure range for the valve operation if appropriate.
NOTE: The flow control valve (FCV) introduces an additional pressure loss in the pipe to control the
flow to the value specified by the user. The additional pressure loss is reported in the results tables.
Using the flow rate and the additional pressure loss the user can calculate the Cv or Kv value for a
suitable valve which will allow the flow to be controlled at the required flow rate.
The flow control valve (FCV) cannot introduce a negative pressure loss. The FCV would need to act
as pump to add pressure, which it cannot do. If this situation is encountered when a system is
analyzed it will not be possible to identify a valid solution. The flow control valve setting will have to
be amended or the flow control valve may have to be removed to allow a solution to be calculated.
1. Open the Set Control Data dialog as described in the previous section.
3. Type the name of the pressure reducing valve in the Control Name field.
5. Enter the allowable differential pressure range for the valve operation if appropriate.
NOTE: The pressure reducing valve (PRV) introduces an additional pressure loss in the pipe to
control the downstream pressure at the end of the pipe to the value specified by the user. The
additional pressure loss across the control valve is reported in the results tables.
A PRV can operate under three different conditions: (1) regulating, (2) fully closed, and (3) fully open.
How the valve operates depends on the defined set pressure value for the valve. The fully open and
fully closed positions represent the extreme operations of the valve. Each of the valve positions is
described below:
(1) Regulating The valve maintains the downstream pressure to the set value by introducing a
pressure loss across the valve, thus throttling the flow rate through the PRV.
(2) Fully Closed This mode of operation occurs if the valve’s set pressure is less than the
pressure downstream of the valve for the case where the valve is closed. When
this occurs in an actual pipe system, the flow through the PRV reverses and the
PRV acts as a check valve, closing the pipe. In PipeFlow Expert, this method of
operation is detected and reported but the system is not then solved for this
scenario. The user must decide if this method of operation is what they intended
and if so then they can close the pipe and continue to solve the system.
112 Pipe Flow Expert User Guide
(3) Fully Open This mode of operation occurs if the valve’s set pressure is greater than the
pressure upstream of the valve for the case where the valve is fully open. When
this occurs in an actual pipe system, the PRV maintains a fully open position
and it has no effect on the flow conditions (except to add a frictional loss through
the valve). In PipeFlow Expert, this method of operation is detected and
reported. But the system is not solved because the differential pressure across
the valve would have to be negative, i.e. the valve would be acting like a pump
rather than a pressure control.
Pipe Flow Expert will only solve a system when the PRV is operating in Regulating mode.
AVOIDING PRV OPERATION PROBLEMS: In general, PRV operation problems can be avoided by
finding the valve's pressure regulating range and specifying the valve’s set pressure to a value within
this range such that the mode of operation is ‘Regulating’. First, solve the system without the PRV
control and note the pressure at the node downstream of the pipe which previously contained the
PRV. This is the maximum pressure the PRV can be set to (i.e. it is equivalent to finding the valve’s
inlet pressure for the case where the valve is fully open). Secondly, solve the system after closing
the pipe that contains the PRV and note the pressure at the node downstream of the closed pipe.
This is the minimum pressure the PRV can be set to (i.e. it is equivalent to finding the pressure
downstream of the valve for the case where the valve is fully closed).
1. Open the Set Control Data dialog as described in the previous section.
3. Type the name of the back pressure valve in the Control Name field.
5. Enter the allowable differential pressure range for the valve operation if appropriate.
NOTE: The back pressure valve (BPV) introduces an additional pressure loss in the pipe to control
the upstream pressure at the start of the pipe to the value specified by the user. The additional
pressure loss across the control valve is reported in the results tables.
A BPV can operate under three different conditions: (1) regulating, (2) fully closed, and (3) fully open.
How the valve operates depends on the defined set pressure value for the valve. The fully open and
fully closed positions represent the extreme operations of the valve. Each of the valve positions is
described below:
(1) Regulating The valve maintains the upstream pressure to the set value by introducing a
pressure loss across the valve, thus reducing the flow rate through the BPV.
(2) Fully Closed This mode of operation occurs if the valve’s set pressure is greater than the
pressure upstream of the valve for the case where the valve is closed. When
this occurs in an actual pipe system, the flow through the BPV reverses and the
BPV acts as a check valve, closing the pipe. In PipeFlow Expert, this method of
operation is detected and reported but the system is not then solved for this
scenario. The user must decide if this method of operation is what they intended
and if so then they can close the pipe and continue to solve the system.
Calculations and Results 113
(3) Fully Open This mode of operation occurs if the valve’s set pressure is less than the
pressure downstream of the valve for the case where the valve is fully open.
When this occurs in an actual pipe system, the BPV maintains a fully open
position and it has no effect on the flow conditions (except to add a frictional
loss through the valve). In PipeFlow Expert, this method of operation is detected
and reported but the system is not solved because the differential pressure
across the valve would have to be negative, i.e. the valve would be acting like a
pump rather than a pressure control.
Pipe Flow Expert will only solve a system when the BPV is operating in Regulating mode.
AVOIDING BPV OPERATION PROBLEMS: In general, BPV operation problems can be avoided by
finding the valve's pressure regulating range and specifying the valve’s set pressure to a value within
this range such that the mode of operation is ‘Regulating’. First, solve the system without the BPV
control and note the pressure at the node upstream of the pipe which previously contained the BPV.
This is the minimum pressure the BPV can be set to (i.e. it is equivalent to finding the pressure at the
valve outlet for the case where the valve is fully open). Secondly, solve the system after closing the
pipe that contains the BPV and note the pressure at the node upstream of the closed pipe. This is
the maximum pressure the BPV can be set to (i.e. it is equivalent to finding the pressure at the valve
inlet for the case where the valve is fully closed).
114 Pipe Flow Expert User Guide
Pumps
A pump can be added to any pipe, except a pipe that contains a control valve.
A pump’s properties, including its pump curve, are defined and graphed on the Pump Data screen.
The Pump Data screen has an interactive graph that allows you to determine which elements of the
pump graph are displayed. It also provides functionality to calculate pump values for different points
on the graph, including the pump’s NPSHr (Net Positive Suction Head requirement) and efficiency
percentage.
You can also save the data associated with a Pump to the Pump Database or a .pfpm file. This
provides a way to share the pump data, and quickly load the pump data, when the same type of
pump is used again in the pipe system or a future pipe system. Saving and loading pump data also
provides a quick and easy way to evaluate different pumps at a specific point in the pipe system to
determine how each one affects the system.
NOTE: Be sure to enter the values for the pump data in the correct units (you can select which units
you wish to use). For example, if you are using metric units, and m for meter is displayed next to a
field, enter the pump value in meters.
Adding a Pump
To add a pump to a pipe:
1. You can add a pump using the Add Pump button on the tool bar or the Add/Change Pump
button in the Pipe Pane.
2. To add a pump using the Add Pump tool bar button, click the Add Pump button, .
3. When you click the Add Pump button, the pump symbol is displayed next to your mouse
pointer when the pointer is in the Drawing pane.
4. Click on the pipe on the Drawing pane where you want to add a pump.
5. You can add a pump to a pipe in the system. Clicking on the pipe opens a Confirm dialog.
6. The Distance Along Pipe and at Elevation fields are automatically populated with default
values. The value in the Distance Along Pipe field is determined by where you added the
pump along the pipe (the distance from start of the pipe). The value in the at Elevation field
is defaulted to the elevation at the start of the pipe.
Calculations and Results 115
7. Click Yes when asked, Do you want to enter the pump data now? Clicking Yes adds the
pump to the system, and opens the Pump Data screen.
8. To add a pump using the Add/Change Pump button in the Pipe pane, select the pipe to
which you want to add a pump in the Drawing pane.
11. The number of pumps currently on the selected pipe is displayed on the Add/Change Pump
button. Clicking the Add/Change Pump button opens the Pump Data screen.
12. The values for Distance Along Pipe and at Elevation fields should be entered by the user.
13. Click the Pump Scroll Up or Scroll Down button to select the pump symbol you want
displayed on the pipe system drawing.
14. The image you select does not affect any of the pump’s properties or values.
15. Use the Pump Data screen to choose the Pump Type to be modelled and to define the
properties of the pump.
This pump type is used to specify the pump flow rate for a positive displacement pump, such as a
piston pump or a peristaltic pump. The system will be solved and the required head from the pump
will be calculated.
If the performance curve for a pump is not available, this pump-type can also be used to establish
the flow / head requirements for a centrifugal pump. Setting the pump to a particular flow rate allows
the system to be solved and the required pump head is then calculated. A user can select a
centrifugal pump that meets the flow and head requirement, after which chosen pump’s flow / head
performance data can be entered and the system re-solved to find the exact operating point on the
pump curve.
116 Pipe Flow Expert User Guide
See the note about limitations of a fixed flow rate pump option.
1. Add a pump to a pipe (as described in the previous Adding a Pump section).
2. Ensure that the distance along the pipe and at elevation fields have been filled in and the
pump symbol you want displayed on the pipe system drawing has been selected.
5. Select the flow rate units and enter the flow rate required.
6. Click the Save button to save the pump flow rate data to the pipe.
The system can now be solved, using the fixed flow rate from the pump.
The fixed flow rate pump cannot adjust to give a flow / pressure balance within the system so some
other part of the system must be allowed to vary. If flow control valves are also used, at least one
flow path must have no control device fitted. If all flow paths are controlled, it will not be possible to
solve the system, and in this case the system is termed over-controlled.
If a pump with a fixed flow rate is used on a ‘main line’ that branches to other paths with flow control
valves then at least one path must have no flow control valve fitted. The flow rate along this path will
be set to the difference between the total flow in all other paths and the flow rate produced by the
fixed flow rate pump.
Flow control valves need to have a positive pressure at their inlet that is sufficient to meet the
ongoing system pressure loss plus the pressure loss that the flow control valve needs to introduce to
achieve a balance within the pipe system. If this positive pressure cannot be achieved, it will not be
possible to solve the system.
Calculations and Results 117
This pump type is used to specify the additional increase in head (pressure) that a pump will add in
to the system. When the system is solved, the flow produced by the pump will be calculated.
When difficulties are experienced in solving a system, perhaps because a chosen pump is not
capable of producing the required flow, it can be useful to solve the system using a fixed head pump
that adds a high pressure. The fixed head added by the pump can then be progressively reduced,
and the system re-solved, to identify the minimum pressure needed to produce the required flow
through the system
Using a fixed head pump as described above can often help identify bottlenecks in the system,
where perhaps design changes can be made to achieve the required flow rate with a lower pump
head
1. Add a pump to a pipe (as described in the previous Adding a Pump section).
2. Ensure that the distance along the pipe and at elevation fields have been filled in and the
pump symbol you want displayed on the pipe system drawing has been selected.
5. Select the head / pressure units and enter the head / pressure to be added.
6. Click the Save button to save the pump head / pressure data to the pipe.
The system can now be solved, using the fixed head / pressure added by the pump.
118 Pipe Flow Expert User Guide
1. Add a pump to a pipe (as described in the previous Adding a Pump section).
2. Ensure that the distance along the pipe and at elevation fields have been filled in and
the pump symbol you want displayed on the pipe system drawing has been selected.
5. Type the pump’s number of rotations per minute (rpm) in the Speed field.
6. Choose the diameter units and enter the pump impeller diameter (if applicable).
7. Select the applicable units for the pump curve from the Flow and Head drop down lists.
8. Determine the points from the manufacturer’s pump graph that you wish to include on the
Pump Curve graph, and enter the head, efficiency and NPSHr values for each of these
points in the Pump Curve section of the Pump Data performance table.
10. Type Define the Preferred Operating Region around the pump’s best efficiency point by
specifying the preferred flow rate range between a From percentage and a To
percentage of the flow at the best efficiency point.
11. Once the operating points have been entered, click the ‘Draw Graph’ button to produce
an operating curve for the pump.
12. Click the Save Pump to Pipe to add the pump data to the Pipe Flow Expert system.
13. The system can now be solved and the balanced operating point of the centrifugal pump
will be determined.
14. The pump will produce a flow rate and pump head to match the frictional resistance
throughout the system. The duty point will be identified on the performance curve for the
operating speed of the pump
.
15. More complex pump graphs can be produced which include speed & diameter
adjustments, together with iso lines that display an efficiency map for the pump.
16. The pump data that has been entered can be saved to a Standalone Pump File with a
pfpm extension by clicking the Save button on the toolbar on the pump ccreen or by
selecting the Save Standalone Pump File from the pump screen file menu options.
17. By saving the data to a Standalone Pump File (with a .pfpm extension), you can reuse
the pump data for other pumps in the pipe system or future pipe systems.
18. To add a pump’s data using an existing .pfpm file, click the Load Pump from File button
or select the Load Standalone Pump File from the pump screen menu options. Select
the applicable .pfpm file, click Open, edit the applicable fields, and then click the Save
Pump to Pipe button.
When a pump is added to a pipe, the Include check box is displayed and set as selected, next to the
Add/Change Pump button, .
When the Include check box is selected, Pipe Flow Expert includes the data from the pumps on the
pipe in the calculations for solving the pipe system. To remove the pump data from the calculations,
clear the Include check box.
120 Pipe Flow Expert User Guide
Once the data for a centrifugal pump has been added, you can view an interactive graphical
representation of the data in the graph section of the Pump Data screen.
1. Click on a pump in a Pipe Flow Expert system to open the Pump Data screen. Click the
Draw Graph button to generate and display the Pump Curve graph.
2. Click the Graph Options button to open the graph options screen. Select the check boxes for
the elements you wish to be displayed on the graph.
3. Clear the check boxes for the elements that you do not want displayed on the graph.
4. When you select a check box, the element appears on the graph. When you clear a check
box, the element is removed from the graph.
5. To view the pump head, NPSHr, efficiency percentage and power for a specific flow rate, type
the flow rate in the Flow field above the graph drawing.
7. The calculated pump head, NPSHr, efficiency percentage, and power for the entered flow
rate are displayed, and the point is mapped on the Pump Curve graph. The design point is
represented by a red marker on the graph.
8. To view the flow rate, NPSHr, efficiency percentage and power for a specific head, type the
pump head in the Head field above the graph drawing.
10. The calculated flow rate, NPSHr, efficiency percentage, and power for the entered pump
head are displayed, and the point is mapped on the Pump Curve graph. The design point is
represented by a red marker on the graph.
11. A logo may be added to the pump graph. Click the Add Logo button on the pump graph area
to load a logo image. Click the Expand button to view a larger graph.
14. Further functionality allows the import of a scanned image of a manufacturer’s pump curve,
plus modelling of performance predictions for changes in pump operating speed and
variations in impeller diameters. The following sections describe the use of these further
options.
122 Pipe Flow Expert User Guide
Pipe Flow Expert provides functionally to import and create a mathematical pump model which
allows adjustment of the pump performance for different operating speeds & impeller diameters.
Click on a pump in a Pipe Flow Expert system to open the Pump Data screen
Click the ‘Import Curve Image’ button to open the import screen.
Step 1:
Import an image of a pump manufacturer’s performance graph
Step 2:
Set the range of the X axis (flow) & the flow units.
Now click the start & end points of the X axis on the
imported image.
Step 3:
Set the range of the Y axis (head) & the head units.
Now click the start & end points of the Y axis on the
imported image.
Step 4:
Click on the ‘Select Points on Curve’ button.
Click the shut off head point at zero flow for the chosen curve.
A red cross shows the point that has been selected.
Calculations and Results 123
Step 5:
Click additional points on the chosen pump curve
(in order to define it across the flow range of the pump).
Enter the Efficiency & NPSHr associated with each operating point.
Repeat for up to 10 points to build the pump model.
Step 6:
This input table can be moved around the screen in order to allow viewing of
any parts of the pump curve which may be obscured. Click on the header
bar and drag it to a new position.
Select from the heading drop down to switch between display of Head,
Efficiency and NPSHr values.
Step 7:
Enter the pump operating speed, impeller diameter and specify the impeller
units.
The imported data produces a pump graph with a flow versus head performance curve. This simple
pump object can be ‘Saved’ on to a pipe within a system.
The Pump Catalog, Manufacturer, Pump Type, Motor rpm, Pump Size, Stages and Notes fields
should be filled in before saving the pump to a system or the pump database.
This supplementary information will be included on the PDF Pump Data Sheet and on the system’s
Results PDF Report when these documents are produced.
The supplementary information will also be available in the future when pump data is loaded from the
pump database.
124 Pipe Flow Expert User Guide
When a system is solved the pump’s operating point will be calculated and the Flow Rate, Head,
Efficiency and NPSHr values will be displayed together with shaft power. A system curve can also be
plotted through the operating point
Further options are available for the modelling of predicted pump performance when changes in
pump operating speed and variations to pump impeller diameters are applied. The following sections
describe the use of these further options
Calculations and Results 125
The pump model may be enhanced to predict the pump performance for a range different operating
speeds & different impeller diameters.
Click the ‘Draw Graph’ button to re-draw and show the new operating
range.
The pump graph will be re-drawn by using standard affinity laws to predict the flow & head
performance for the maximum & minimum impeller diameters.
In many cases the predicted performance curves will agree closely with a pump manufacturer’s
published graph, however for more accurate modelling of pump performance, it may be necessary to
adjust the predicted shut-off head, curvature & efficiency points for the predicted curves at the
maximum and minimum impeller diameters.
The ‘Adjust Flow v Head’ options can be used to adjust the shut-off head & the rate of curvature for
the minimum & maximum impeller diameter curves, to match them to the published performance
data.
The ‘Adjust Predicted Efficiencies’ options allow the predicted efficiency values to be modified to
match the published performance data.
Once a further adjustment has been made to the data the iso
efficiency shape selection type will become user defined match.
The slide adjustments allow the curvature of groups of iso efficiency lines to be moved as a block to
the left or right. The BEP (best efficiency point) on the base data performance curve is used to divide
the performance graph into different areas.
These adjustments should be used to match the efficiency points on the maximum and minimum
impeller performance curves.
Final adjustment of individual efficiency points on the maximum and minimum performance curves
can be made (if necessary) by selecting the ‘Update Individual Efficiency Points’ option.
Additional adjustments for NPSHr and efficiency predictions at different operating speeds can also
be made in order that the performance of the pump across a range of speeds and impeller diameters
is accurately mapped.
The efficiency of a centrifugal pump generally reduces as the operating speed is reduced. It can be
seen from many pump manufactures performance graphs that a speed reduction of 50% will reduce
the pump efficiency by around 5%.
When a pump is required to operate at low flow rates and/or in low efficiency areas a centrifugal
pump may not perform as expected. Operation in these areas may not be recommended.
The minimum flow line can be set as a percentage of the maximum flow on a particular curve.
Pipe Flow Expert will not include pumps which operate below the minimum flow line setting when
searching the pump database for suitable pumps to match a particular flow rate.
Once a pump has been modelled to match the published data, the complete pump model can be
saved to the searchable Pump Database for future use. A pump data sheet in PDF format can also
be produced. This shows detailed information about the pump and provides a scalable high
resolution image of the pump performance graph.
The adjusted pump graph can be used in a Pipe Flow Expert system to model the complete
performance of the pump over a range of speeds and impeller sizes.
A logo image can also be added to the pump graph to assist with identification of the pump.
Calculations and Results 129
The Pump Database can be used to search for pumps that match a set of specified criteria, which
include flow & head requirements within a given speed range. There are further search refinements
that filter the results to look for solutions with the best efficiencies, largest impellers or fastest
operating speeds.
The user can work through the pump search results by clicking on a row in the Filtered Results Grid
or by using the up and down cursor keys to scroll through rows in the grid. As a row on information
about a pump is highlighted, the corresponding pump performance graph is shown
Click the ‘Select this Pump’ button to transfer the chosen pump details to the
pump data screen.
130 Pipe Flow Expert User Guide
The Pump Database can also be switched in to Browse mode, which allows a user to select a Pump
Library from a dropdown list of folders. This is automatically populated with a list of available pump
folders from within the Pipe Flow Expert installation.
Once a folder is selected, the pumps within the chosen pump library folder are displayed in the
Browse List, where the user can click on a pump to show its corresponding pump performance
graph.
The units used to display the flow rate and pump head on the performance graph should be selected
from the dropdown options in the Browse window.
The pump data may have originally been created using flow rate units and head units that are
different from those now required. Selection of new flow and head units will produce a new
performance graph in the chosen units, with the software automatically converting the original data to
the new flow and head units.
Both the performance curve and the NPSHr curve can be shown in the pump graph window.
As the user browses a Pump Library folder, pumps can ‘saved’ for further consideration by clicking
the button to add them to the filtered list.
Once a user has found a suitable pump, it can be selected for use in the pipe system by clicking the
‘Select’ button, or by double clicking on the chosen pump.
Calculations and Results 131
When a user opens the Pump Database all sub-folders within the main ‘Pumps’ folder will be
displayed within the Library dropdowns of the Search and Browse sections. An appropriate folder
should be chosen on which to perform the Search or Browse.
The example pumps can be loaded and used to see the results that are produced by using different
pump operating data. This data is provided solely as example data and is not related to any specific
pump manufacturer.
When adding further pump data to the pump database, we recommend that a new folder is created
for each pump manufacturer. The pumps can then be organized and saved in named folders.
132 Pipe Flow Expert User Guide
Demand Flows
A demand in-flow or demand out-flow can be set at any join point in the system, or at the end of a
single pipe if flow is entering or leaving the system at that point. A demand can also be the pressure
required at an end node, however a node cannot have both a demand flow and a demand pressure.
A demand in-flow is the volume of fluid required to enter the system at a join point.
A demand out-flow is the volume of fluid required to leave the system at a join point.
Demand flows may also be used to specify the required flow rate at the end of a pipe where fluid is
flowing out of the system, or to specify the flow rate at the end of a pipe where fluid is entering the
system. A pipe can have a demand flow or a demand pressure at the end of a pipe but it cannot
have both.
Demand flows can be added to a join point from the Node pane or the Drawing pane. Demand flow
values are set on the Set Flow Demands dialog. The demand flows are then shown at the
appropriate node on the Drawing pane.
NOTE: Be sure to enter the value for the required fluid flow rate in the units displayed next to the
3
field. For example, if you are using imperial units, and ft /sec for cubic feet per second is displayed
next to the In Flow and Out Flow fields, enter the value in cubic feet per second.
2. When you click the Add Demand (Flow) button, the demand flow symbol is displayed next to
your mouse pointer when the pointer is in the Drawing pane.
3. Click on the join point on the Drawing pane where you want to add a demand flow.
5. To add a demand flow from the Node pane, select a join point on the Drawing pane to display
the join point’s properties in the Node pane, and then click one of the Edit buttons in the
Node pane to open the Set Flow Demands dialog. Both Edit buttons in the Node pane open
the Set Flow Demands dialog.
Calculations and Results 133
6. Select the flow units from the drop down list of available units.
7. Type the required flow rate for the fluid ENTERING the system at the join point in the In Flow
field, if applicable.
8. Type the required flow rate for the fluid LEAVING the system from the join point in the Out
Flow field, if applicable.
9. If you select a different flow unit, the value entry will be converted automatically to the
equivalent value for the current selected flow unit.
Demand Pressures
A demand pressure can only be set at exit points from the system, i.e. the boundaries or end nodes.
A demand pressure, referred to as an end pressure in the Node pane, is the required pressure
demand at the end of a pipe when the fluid is discharged. For example, in a sprinkler system, each
sprinkler head may have a required minimum pressure. To find the fluid flow rate exiting the pipe
system, a demand pressure is drawn and the required pressure set for each sprinkler head. Demand
pressures can only be set at the end of a pipe that does not join into anything else.
A pipe can have a demand flow or a demand pressure at the end of a pipe but it cannot have both.
2. When you click the Add Demand (Pressure) button, the demand pressure symbol is
displayed next to your mouse pointer when the pointer is in the Drawing pane.
3. Click on the end of a pipe on the Drawing pane where you want to add a demand pressure.
4. Click Yes when asked ‘Do you wish to change the type of node to an end demand pressure?’
5. The demand pressure is added to the pipe system, and is selected on the Drawing pane.
Define the demand pressure’s properties in the Node pane.
8. Click the Demand Pressure Scroll Up or Scroll Down button to select the demand pressure
image you want displayed on the pipe system drawing.
9. The image you select does not affect any of the demand pressure’s properties or values.
10. Type the required pressure for the end of the pipe in the Pressure field.
11. Type the elevation at the demand pressure in the Elevation field.
12. Type any applicable notes regarding the demand pressure in the Notes field.
13. To add additional demand pressures to the system, repeat Steps 3 – 12.
136 Pipe Flow Expert User Guide
Text Items
Text items allow you to add free text labels at any position on the pipe system drawing. These are
useful for annotating a system during and after the design process and provide an easy and clear
way to provide additional details about specific items on the drawing.
Using the Add Text button, , on the tool bar, you can add text to the drawing and/or modify text
that has been previously added.
2. A circle will appear at the top left of any text that has been previously added.
3. To modify previously added text click this circle to display the Add Free Text Label dialog.
4. To add new text click in a clear space on the drawing pane to display the Add Free Text
Label dialog.
5. Enter or amend the text, choose the color, size, style and angle for the text.
6. Click OK to place the text on the drawing at the position that was clicked.
7. To align the text to the nearest grid intersection check the Left Align to Grid / Top Align to
Grid check boxes before clicking the OK button
9. To move the individual text to a new position, use the Drag and Move menu button to
highlight all items on the drawing. Select a highlighted item of text, and while holding down
the left mouse button, drag the text to its new position on the drawing.
10. The text may also be moved as part of a selected group. Use the selection tool to enclose the
items to be moved, and include the top left area of any text to be moved.
138 Pipe Flow Expert User Guide
Additional details can be viewed for components by clicking the Show Item Info button, , on the
tool bar and selecting a specific component in the Drawing pane.
The following sub-sections describe zooming, viewing, panning, modifying and moving items.
If your mouse has a scroll button, you can also use the scroll button to zoom in and out in the
Drawing pane. Scroll down to zoom out, and scroll up to zoom in.
1. Click the, , Zoom Out button on the tool bar to view the system farther out in the
Drawing pane.
2. Click the, , Zoom In button on the tool bar to magnify the system in the Drawing pane.
3. To view a large pipe system in its entirety, you can click the , Zoom Drawing to Fit
Screen button to see the whole system in the Drawing pane.
4. Click a zoom percentage from the, , Zoom list on the tool bar to zoom in or out in
the Drawing pane.
2. When you click the Selection tool button, the selection icon is displayed next to your mouse
pointer when the pointer is in the Drawing pane.
3. Draw a box around the node or group of components you want to view in the Drawing pane.
Calculations and Results 139
4. To draw a box, click where you want to start the box in the Drawing pane and hold down the
left mouse button, then drag the mouse until you have drawn the box.
6. Click the selected area , , Zoom Tool Button, located among the ‘Selection Tool
Buttons’.
7. The selected area will be displayed in the center of the drawing pane.
If no selection has been made the selection zoom tool button will increase the display by one
scale increment.
To view the whole of a pipework system click the, , Zoom Drawing to fit Screen button, , on
the tool bar, to fit the system in the visible Drawing pane
2. When you click the Pan the drawing button, the hand symbol is displayed next to your
mouse pointer when the pointer is in the Drawing pane.
3. Click and hold down the left mouse button anywhere in the Drawing pane.
5. Release the left mouse button when you are done moving or panning the pipe system.
The pan function can also be accessed by clicking in ‘white space’, when either the ‘Show mode’
or the ‘Move mode’ has been selected.
140 Pipe Flow Expert User Guide
If the drawing scale is too small to see the pipe or node location, the zoom button , , can be used
to display the selected pipe or node in the visible drawing window at an increased scale.
Making amendments to your system usually involves changing the diameter, length or material of a
pipe or group of pipes. It may also involve changing the node elevations where the pipes are linked.
a. Use the Edit Grid to display, filter and edit the data for Pipes, Nodes, and other items.
b. Click on the pipe or node and update the entries shown on the Pipe Pane or the Node Pane.
c. Set the Default Pipe data, select a group of items to be amended, or select a collection of
individual items and then copy some or all of the Default Pipe attributes to the selected items.
2. Choose a tab to display data for Pipes, Tanks, End Pressures, Nodes, FCVs, PRVs, BPVs,
Cv Values, Kv Values, Fixed Losses, Pumps (Fixed Flow), Pumps (Fixed Head) and Pumps
(Curve).
3. Select the cell that contains the data you want to edit.
4. The Edit Grid can be over-typed and updated directly (changes are applied immediately).
Note: The changes will be applied immediately and the drawing will be updated. An Undo option
is not available hence amendments cannot be cancelled; the original data must be re-entered.
1. The Edit Grid can be ‘Filtered’ to only show rows that match certain specified criteria. For
example the data shown on the Pipe Tab can be filtered by: Pipe ID, Pipe Name, Nominal
Size, Material/Sch., Diameter, Roughness or length.
2. The filtered data values can be updated on an individual basis or they can be amended as a
group, in a single operation, by selecting an item to update from the drop down list, entering a
value to ‘Set’, and clicking on the ‘Update Rows’ button.
Using the Show Item Info button, , on the tool bar, you can view and/or modify the specific
details about any component in a pipe system. Depending on the type of component you select,
clicking a component in the Drawing either displays the component’s information in the Node or Pipe
pane, or opens up the dialog specific to the selected component.
2. When you click the Show Item Info button, SHOW is displayed next to your mouse pointer
when the pointer is in the Drawing pane.
3. Click a component in the Drawing pane that you want to view and/or edit.
4. When you select a tank, join point, or demand pressure, its details are displayed, and can be
edited in the Node pane.
5. When you select a demand flow, the Set Flow Demands dialog opens, and you can view
and edit the demand flow values.
6. When you select a pipe, the pipe’s details are displayed, and can be edited in the Pipe pane.
To view and edit a pipe’s material and/or size, click the Diam? or Material buttons in the Pipe
pane to open the Pipe diameter data screen.
7. When you click a fitting symbol or a valve symbol , on a pipe the Pipe fitting friction
coefficients screen opens. You can view and edit all fittings on the pipe containing the fitting
you selected in the Drawing pane. You can also select a pipe in the Drawing pane, and then
click the Add/Change Fittings button, , in the Pipe pane to open the Pipe fitting
friction coefficients screen.
8. When you click a component symbol on a pipe, , the Set Component Pressure Loss
dialog opens, and you can view and edit the component’s pressure loss values. You can also
select a pipe in the Drawing pane, and then click the Add/Change Component Pressure
Loss button, , in the Pipe pane to open the Set Component Pressure Loss dialog.
9. When you click a control valve symbol on a pipe, , the Control Valve Data screen
opens, and you can view and edit the control valve type or values. You can also select a pipe
in the Drawing pane, and then click the Add/Change Control Valve button, , in the
Pipe pane to open the Control Valve Data screen.
Calculations and Results 143
10. When you click a pump symbol on a pipe, , the Pump Data screen opens, and you can
view and edit the pump’s properties. You can also select a pipe in the Drawing pane, and
then click the Add/Change Pump button, , in the Pipe pane to open the Pump Data
screen.
The Selection tool button allows the user to select a group of items which are located within an
area defined by a rectangle. While holding down the left mouse button, drag the mouse to create a
rectangle around the item(s) you want to select.
The selected items can then be amended using the following operations:
Cut, Copy, Paste, Mirror, Invert, Zoom in, Adjust Attributes (Pipes), Adjust Attributes (Nodes), &
Delete.
When the ‘Adjust Attributes of Selected Pipes’ button is clicked, a screen showing the current
‘Default Pipe’ attributes and a list of selected pipes is displayed (selected pipes are shown as
checked). The ‘Default Pipe’ data can now be amended as required and then the buttons in the
middle of the screen can be used to copy items values to the group of selected pipes.
When the ‘Adjust Attributes of Selected Nodes’ button is clicked, a similar screen to the one
above is shown, except on the left hand side it shows Default Node values and on the right a list of
selected nodes is displayed. Data values can be copied from the default node to the selected nodes
using the ‘copy’ buttons in the middle of the screen.
The individual Selection tool button allows the user to select an adhoc group of pipes and
nodes, on a one-by-one basis. This is often useful when the group of items to updated are positioned
within different parts of the drawing, such that they cannot be selected inside a standard rectangle
(without including other items that are not wanted)
Again the characteristics for these individually selected ‘groups’ of items can be
updated in one operation by using the ‘Adjust Attributes of Selected Pipes’ and
‘Adjust Attributes of Selected Nodes’ buttons.
Using the Drag and Move Items button, , on the tool bar, you can move a node, and all the
components connected to the node, or you can move individual components on a pipe in the
Drawing pane.
Using the Selection tool button, , on the tool bar, you can move nodes or groups of components
in the Drawing pane.
To move system components using the Drag and Move Items button:
1. Click the Drag and Move Items button, , on the tool bar.
2. When you click the Drag and Move Items button, each of the pipe system’s components are
highlighted in the Drawing pane. MOVE is displayed next to your mouse pointer when the
pointer is in the Drawing pane.
3. Click the component you want to move and hold down the left mouse button in the Drawing
pane.
5. Release the left mouse button when you are done moving the component.
When you move components using the Drag and Move Items button, the values for the moved
components do not change. If you want to change the value of a moved component, such as pipe
length, the value needs to be manually updated in Pipe Flow Expert.
2. When you click the Selection tool button, the selection icon is displayed next to your mouse
pointer when the pointer is in the Drawing pane.
3. Draw a box around the node or group of components you want to move in the Drawing pane.
4. To draw a box, click where you want to start the box in the Drawing pane and hold down the
left mouse button, then drag the mouse until you have drawn the box.
6. Click in the box and hold down the left mouse button, then drag the box to the new location in
the Drawing pane. Moving the box automatically moves the node or group of components
within the box.
7. Release the left mouse button and right-click when you are done moving the component.
When you move components using the Selection tool button, the values for the components that
are moved do not change. If you want to change the value of a moved component, such as pipe
length, the value needs to be manually updated in Pipe Flow Expert.
When you paste a group of objects on to the Drawing pane, these items will initially appear slightly
offset from the position of the original copy operation. The group of objects will be contained in a
selection rectangle, to allow the objects to be moved to a new position. Once the selected items
have been positioned, click the right mouse button to complete the paste operation.
If you try to paste a node over the top of an existing node or an existing pipe, the paste action will be
disallowed.
NOTE: A cut, copy, or paste action in the Drawing pane cannot be undone.
To cut, copy, and paste nodes and pipes in the Drawing pane:
2. When you click the Selection tool button, the selection icon is displayed next to your mouse
pointer when the pointer is in the Drawing pane.
3. Draw a box around the pipes and nodes you want to cut or copy in the Drawing pane. To
draw a box, click where you want to start the box in the Drawing pane and hold down the left
mouse button, then drag the mouse until you have drawn the box and then release the left
mouse button.
4. To cut the nodes and pipes, click the Cut button, , on the tool bar or select Edit | Cut
Any pipes which have one end connected to a selected node but are not linked at the other
end to another selected node, will be permanently removed from the system.
146 Pipe Flow Expert User Guide
5. After clicking the Cut button or selecting Edit | Cut, a message asking if you are sure you
wish to cut the nodes and all pipes that connect to these nodes will be displayed.
6. Click Yes.
7. You may wish to copy rather than cut a set of selected items. To copy the nodes and pipes,
8. Click the Paste button, , on the tool bar or select Edit | Paste to paste the cut or copied
nodes and pipes to the Drawing pane.
9. When you paste nodes and pipes to the Drawing pane, these items will be pasted slightly
offset from the position of the original copy operation. The group of new objects will be
contained in a selection rectangle.
10. Click in the box and hold down the left mouse button, then drag the objects to their new
location in the Drawing pane.
11. Release the left mouse button, to allow the objects to locate on the drawing grid.
12. Click the right mouse button to complete the paste operation.
The Selection tool button, , allows a group of nodes and pipes to be copied, as described in
the previous section. It is possible to use the group copy and the paste feature to transfer a group of
nodes and pipes from one drawing to another drawing.
Nodes and pipes on the current drawing are selected and copied.
The Paste button, , can be used to place the copied nodes and pipes on to the new drawing
The Selection tool button, , allows a group of nodes and pipes to be selected, as described in
the previous section. It is possible to use the options on the edit menu to rotate the selected group
either 90 degrees clockwise or 90 degrees anticlockwise. The mirror or invert features can also be
applied to the selected group.
The Mirror Selection button, , can be used to mirror the selected group.
The Invert Selection button, , can be used to invert the selected group.
Pipe Flow Expert does not allow one node to be placed over the top of another node, or over the top
of an un-related pipe. This restriction is applied to prevent confusion.
When the rotated, or mirrored, or inverted group are added back to the drawing the action may be
disallowed if the above conditions apply. The selected group will have to be re-positioned to allow
the items to be ‘dropped’ back onto the drawing pane.
5. The ‘direction arrow’ end of the pipe will be unlinked to allow you to connect the pipe at a new
position.
The ‘Move / Unlink end of Pipe’ option can also be performed when in ‘Add Pipes’ drawing mode,
by ‘clicking’ on a pipe to first highlight it, then ‘clicking’ again on the highlighted pipe to ‘unlink’ it.
148 Pipe Flow Expert User Guide
To undo an add pipe or node action in the Drawing pane, click the Undo button, , on the tool bar
or select Edit | Undo.
To redo an undo action in the Drawing pane, click the Redo button, , on the tool bar or select
Edit | Redo.
NOTE: If you added new components, such as fittings or flow demands, to a pipe or node, and you
then click the Undo button or select Edit | Undo, and then click the Redo button or select Edit | Redo,
then the pipe or node will be re-added to the Drawing pane without the components. When you use
the undo action for a pipe or node with components, any components that were not drawn as part of
the default pipe are permanently removed from the pipe.
Nodes (tanks, demand pressures, or join points), individual pipes, and groups of components are
deleted from a pipe system using the Delete button, , on the tool bar. Other pipe system
components are deleted on the dialog associated with that component. For example, fittings on a
pipe are deleted from the Pipe fitting friction coefficients dialog.
2. Click the node or pipe you want to delete in the Drawing pane.
3. You can also select a node or pipe for deletion by using the Selection tool button, , on
the tool bar.
4. Click the Delete button, , on the tool bar or select Edit | Delete.
5. If you are deleting a node, the message, Are you sure you wish to delete the current
highlighted node and all pipes that connect to the highlighted node?, is displayed after
clicking the Delete button or selecting Edit | Delete.
Calculations and Results 149
6. If you are deleting a pipe, the message, Are you sure you wish to delete the current
highlighted pipe?, is displayed after clicking the Delete button or selecting Edit | Delete.
7. Click Yes.
8. The selected node or pipe is deleted. When you delete a node, all pipes and components
connected to the node are deleted. When you delete a pipe, all components on the pipe are
deleted with the pipe.
2. When you click the Selection tool button, the selection icon is displayed next to your mouse
pointer when the pointer is in the Drawing pane.
3. Draw a box around the group of components that you want to delete in the Drawing pane.
4. To draw a box, click where you want to start the box in the Drawing pane and hold down the
left mouse button, then drag the mouse until you have drawn the box.
6. Click the Delete button, , on the tool bar or select Edit | Delete.
7. The message, Are you sure you wish to delete the selected nodes and all pipes that connect
to these nodes?, is displayed after clicking the Delete button or selecting Edit | Delete.
8. Click Yes.
9. The selected nodes and all the pipes and their components that are connected to the nodes
are deleted.
2. Click the node containing the demand flow that you want to delete in the Drawing pane.
3. Click one of the Edit buttons in the Node pane to open the Set Demand Flow dialog.
5. If the Out Flow field contains a value other than 0.000, type 0.
150 Pipe Flow Expert User Guide
6. Click OK to save your changes and close the Set Demand Flow dialog.
7. The demand flow icon and value are removed from the selected node in the Drawing pane.
Deleting Fittings
To delete a fitting from a pipe system:
2. Click the fitting symbol, , on the pipe containing the fitting that you want to delete in the
Drawing pane.
3. Clicking the fitting symbol opens the Pipe fitting friction coefficients dialog with all the
fittings on the pipe listed in the Fittings on section.
4. You can also select the pipe containing the fitting that you want to delete in the Drawing
pane, and then click the Add/Change Fittings button, , in the Pipe pane to open the
Pipe fitting friction coefficients dialog.
5. Select the row containing the fitting that you want to delete in the Fittings on section.
6. Click the Delete button, , next to the row that shows the K value for the
fitting, to delete the fitting(s) from the selected pipe.
7. Click the Save button in the Pipe fitting friction coefficients dialog to save your changes
and close the Pipe fitting friction coefficients dialog.
8. If you deleted all the fittings on the pipe, the fittings symbol on the selected pipe is deleted in
the Drawing pane.
2. Click the component pressure loss symbol, , on the pipe containing the component
pressure loss that you want to delete in the Drawing pane.
3. Clicking the component pressure loss symbol opens the Set Component Pressure Loss
dialog.
4. You can also select the pipe containing the component pressure loss that you want to delete
in the Drawing pane, and then click the Add/Change Component Pressure Loss button,
, in the Pipe pane to open the Set Component Pressure Loss dialog.
5. If you want to save and reuse the component pressure loss data for other pipes in the pipe
system or future pipe systems, be sure to click the Save To File button and save the
Calculations and Results 151
pressure loss data to a .pfco file before deleting the component pressure loss from the
selected pipe.
7. The message, Are you sure you wish to delete the component and its data from this pipe?, is
displayed after clicking the Delete button.
8. Click Yes.
9. The component pressure loss icon and values are removed from the pipe in the Drawing
pane.
2. Click the flow control symbol, , on the pipe containing the flow control that you want to
delete in the Drawing pane.
3. Clicking the control valve symbol opens the Control Valve Data dialog.
4. You can also select the pipe containing the control valve that you want to delete in the
Drawing pane, and then click the Add/Change Control Valve button, , in the Pipe
pane to open the Control Valve Data dialog.
6. The control valve icon and value are removed from the pipe in the Drawing pane.
Deleting a Pump
To delete a pump from a pipe system:
2. Click the pump symbol, , on the pipe containing the pump that you want to delete in the
Drawing pane.
4. You can also select the pipe containing the pump that you want to delete in the Drawing
pane, and then click the Add/Change Pump button, , in the Pipe pane to open the
Pump Data dialog.
5. If you want to save and reuse the pump data for other pumps in the pipe system or future
pipe systems, be sure to click the Save To File button and save the pump data to a .pfpm file
before deleting the pump from the selected pipe.
152 Pipe Flow Expert User Guide
7. The message, Are you sure you wish to delete the pump and all pump data from this pipe?, is
displayed after clicking the Delete button.
8. Click Yes.
9. The pump icon and value are removed from the pipe in the Drawing pane.
The calculated values displayed in the Drawing pane are determined by the options selected on the
Labelling and Units tab of the Configuration Options dialog.
The Results tables contain all of the calculated values for the whole pipe system, including pipe data,
fitting data, component data, pump data, fluid data and node data.
When you calculate a pipe system, a log is generated and displayed in the Results Log dialog. If a
pipe system cannot be solved, the log provides additional information and may offer some
suggestions as to why the system cannot be solved.
To calculate the balanced results for a pipe system in the Drawing pane, click the Calculate button.
The ‘Include’ check boxes in the Pipe pane allow you to include or exclude the fittings, component
pressure losses, control valves, and pumps when solving the system. The check boxes allow you to
view and re-run the system calculations without having to delete and re-add the components to the
system.
Select an Include check box to include a component’s values in a system’s calculations. Clear an
Include check box to exclude a component’s values from a system’s calculations.
Calculation Theory and Method of Solution 153
The software interface is intuitive and it provides easy access to amend the system data as required,
however standalone changes to pipe diameters, pipe lengths and node elevations can sometimes
create inconsistence’s in the design data.
Where an Internal Diameter has been amended by over typing the data in the pipe pane or the edit
grid the Outer Diameter, Wall Thickness & Internal Diameter may no longer be consistent with each
other.
The option to update Outer Diameters and Wall Thicknesses should normally be accepted. This will
allow the diameter data to be made consistent and the nominal pipe size will then be recalculated.
Fitting sizes will be checked and matched to the nominal pipe size.
If the nominal pipe size does not match some of the fitting sizes associated with the pipe, then the
option to update the fitting sizes should normally be accepted. This will update the fitting sizes and
the fitting ‘K’ values so that the fitting pressure losses will be calculated correctly.
154 Pipe Flow Expert User Guide
Where pipe lengths are not sufficient to span the difference in node elevations, these pipes will be
identified and the user will be asked to confirm an update for each pipe. The pipe length can
automatically be set to the difference in start and end elevations of the pipe.
The changes in pipe length will be noted in the results log when the system is solved. The user may
wish to check that the lengths of these pipes are also sufficient to cover any additional length that
may be required if the pipe is not vertical (a none vertical, sloped pipe, would need to have a length
that was greater than just the change in elevation between its start and end node). Where the pipe
direction is not vertical and the length has been set to less than the difference in elevation between
its start node and end node, it will be necessary to amend each pipe length manually, in the pipe
pane or edit grid.
1. Open the .pfe file for the pipe system you want to calculate in Pipe Flow Expert.
2. The pipe system is displayed in the Drawing pane. In order to calculate a system’s values,
the pipe system must be open in the Drawing pane.
4. The system results are calculated and the Results Log dialog is shown.
Calculation Theory and Method of Solution 155
If the pipe system is solved, the message ‘The network was solved successfully’ is displayed in the
Results Log dialog.
If the pipe system is not solved, the log offers some suggestions as to why the system could not be
solved, and the message ‘The network was not solved. See log details above.’ is displayed in the
Results Log dialog. When this happens, review the log and click OK to return to the Drawing pane
in design mode. Make the necessary changes to the system to resolve the design errors in the
system, and click the Calculate button on the tool bar to recalculate the revised system.
If the Results Log has been closed, it can be re-opened by clicking the Show Log button on the
toolbar.
To change back to Design Mode, close the Results Log and then click on the Re-Design button on
the toolbar.
Click the View Results Drawing button on the results log to display the drawing with results.
156 Pipe Flow Expert User Guide
The details for the last node or pipe selected with a mouse click will be displayed in the hint pane.
Moving the cursor over an item on the drawing will allow the user to view the calculated results in a
pop-up data pane.
Click the View Results Sheet button on the results log to open the Results Table.
When an item is highlighted in the results sheet table, the selected item is also highlighted on the
drawing pane and data for the highlighted item is displayed in the Hint pane.
If the results tables have been closed, click the Result Sheet button on the toolbar to reopen the
Results Tables.
Units and Labelling Note: First configure the labelling and units to be used, as described in the
section ‘Configuring the System Results’.
Click the Create PDF Report button to open the PDF report dialog.
3. Select the Cover Sheet, Header Information and Page Information options.
5. Choose the Pipe Data, Node Data and Energy Data to be included.
6. Click the Create PDF Report button to generate a PDF results document.
158 Pipe Flow Expert User Guide
You can also reconfigure the units for the pipe system results on the Units tab of the Configuration
Options dialog. You can access the Units tab of the Configuration Options dialog by selecting
Specify Units from the Units menu, or clicking the Choose Units button, , on the toolbar, or
clicking the Choose Units button in the Results dialog.
1. Click the Choose Labelling button, , on the tool bar to open the Labelling tab of the
Configuration Options screen.
Calculation Theory and Method of Solution 159
2. Click one of the labelling options in the Pipe Results, Fitting Results, Pump Results and
Node Results sections to determine which of the pipe system’s calculation results are
displayed in the Drawing pane.
3. Click OK to close the Configuration Options dialog and apply your changes to the results
displayed in the Drawing pane.
To reconfigure the units used in a pipe system and its calculated results:
1. Click the Choose Units button, , in the Results dialog or on the tool bar, or select
Specify Units from the Units menu to open the Units tab of the Configuration Options
screen.
160 Pipe Flow Expert User Guide
Do not click the Imperial or Metric option in the Change All Units section of the Units tab, unless
you want to change the universal unit setting and reset all the values currently defined on the Units
tab.
NOTE: When you change the universal unit setting, it converts all unit values to the unit type
selected, and all values on the Units tab of the Configuration Options screen are converted to the
fields’ default values. For example, if you are changing the universal setting from imperial to metric,
all values, including any imperial units selected on the Units tab of the Configuration Options
screen, are converted to metric. All field values on the Units tab are also reset to their default metric
value.
Click OK to close the Configuration Options dialog and apply the unit configurations to the pipe
system and its results.
The Results Tables contain a series of tabs that display the calculated results for each component of
the pipe system in a table. The tabs are organized by component type, except for the All Results tab.
Calculation Theory and Method of Solution 161
The All Results tab displays all of the calculated results by component type. All values displayed in
the Results Tables are read-only.
1. After a pipe system has been calculated and solved, click the View Results Sheet button
on the Results Log dialog to open the Results Tables or close the results log and click
the Results Sheet button on the tool bar.
3. Click the Close button, , to close the Results Tables and return to the Drawing
pane.
1. After a pipe system has been calculated and solved, click the View Results Sheet button
on the Results Log dialog to open the Results Tables or close the results log and click
the Results Sheet button on the tool bar.
3. Click the Save button, , or select File | Save to Excel to open the Save As dialog.
162 Pipe Flow Expert User Guide
5. Select Pipe Flow Network (*xlsx) from the Save as type list.
6. Click Save to save the pipe system results from the selected tab.
1. After a pipe system has been calculated and solved, click the View Results Sheet button on
the Results Log dialog to open the Results Tables or close the results log and click the
Results Sheet button on the tool bar.
4. Clicking the Export to Excel button or menu selection opens the pipe system results from the
selected tab in a worksheet in Microsoft Excel.
If Microsoft Excel is not available the results can be copied to the Windows clipboard, so that the
data can be pasted into other spreadsheet applications.
Calculation Theory and Method of Solution 163
If you want to retain the original solved pipe system and the calculated values for the system before
you redesign the pipe system, be sure to save the pipe system and results before clicking the Re
Design button.
When a pipe system cannot be solved, additional information is displayed in the Results Log and the
message, ‘The network was not solved. See log details above.’, is shown. Clicking OK on the
Results Log automatically returns you to the Drawing pane in design mode.
a. Use the Edit Grid to display, filter and edit the data for Pipes, Nodes, and other items.
b. Click on the pipe or node and update the entries shown on the Pipe Pane or the Node Pane.
c. Set the Default Pipe data, select a group of items to be amended, or select a collection of
individual items and then copy some or all of the Default Pipe attributes to the selected items
These amendment options are described in the ‘System Amendments and Group Updates’ section
of this document.
164 Pipe Flow Expert User Guide
The report can contain a cover sheet with your logo, a scalable results drawing for high resolution
printing and a selection of tabulated results data, which provides a detailed breakdown of the
calculated results.
Note: First configure the results drawing labelling and the results units to be used, as described in
the section ‘Configuring the System Results’.
To display the Create PDF Report options dialog choose one of these actions:
• Click the ‘Create PDF Report’ button on the Results Log (after solving a system) OR
• Click the ‘Results PDF’ Tool Button in the tool bar at the top of the screen OR
• Click the ‘Create PDF – Customized Report’ option from the File menu
Choose the options for the PDF Report by selecting and checking the appropriate items from the
PDF Report Generator screen.
The company information, the cover sheet image, and all the other selected options can be saved for
future use. Click the ‘Save Report Options’ button to display the ‘Save As’ dialog.
Previously saved report options can be reloaded. Click the ‘Load Report Options’ button to display
the ‘Open dialog.
3. Select the Cover Sheet, Header Information and Page Information options.
5. Choose the Pipe Data, Node Data and Energy Data to be included.
6. Click the Create PDF Report button to generate a PDF results document
The generated PDF report file will be displayed in your PDF Adobe Reader program.
The PDF file will be automatically stored in the user’s local temporary folder, however the user may
wish to save a copy of this document to a different location using the ‘Save a Copy’ option from
Adobe Reader file menu.
166 Pipe Flow Expert User Guide
The pipeline system is modeled by drawing the join points and the connecting pipes on a drawing
pane. Horizontal, vertical or sloping lines can be used to connect one node to another node.
The physical data about the system is then entered, and typically this includes:
• The internal size, internal roughness and length of each connecting pipe.
• The elevation of each node (join point).
• The In-flow and the Out-flow at each node (if applicable).
• The elevation, liquid level and surface pressure data for each tank.
• The performance data for each pump.
The friction within the fluid is due to the fluid's viscosity. When fluids have a high viscosity, the speed
of flow tends to be low, and resistance to flow becomes almost totally dependent on the viscosity of
the fluid. This condition is known as 'Laminar flow'.
Fluids which have a low viscosity are usually moved at higher velocities. The flow characteristics
change, small eddy currents occur within the flow stream, and the friction between the pipe work and
the fluid becomes a factor to be considered. This type of flow is known as 'Turbulent flow'.
Fluid Viscosity
A fluid viscosity can be described by its Dynamic viscosity (sometimes called Absolute viscosity), or
it’s Kinematic viscosity. These two expressions of viscosity are not the same, but are linked via the
fluid density.
Dynamic Viscosity
-3
Water @ 20°C has a viscosity of 1.00 x 10 Pa • s or 1.00 Centipoise
-5
Water @ 70°F has a viscosity of 2.04 x 10 lb •s/ft²
Kinematic Viscosity
-6
Water @ 20°C has a viscosity of 1.004 x 10 m /s² or 1.004000 Centistokes
-6
Water @ 70°F has a viscosity of 10.5900 x 10 ft /s²
Pipe Flow Expert has a database of viscosities and densities for common fluids.
Calculation Theory and Method of Solution 167
Reynolds Numbers
Reynolds numbers (Re) describe the relationship between a fluid's velocity, the
Internal pipe diameter and the fluid's Kinematic viscosity.
Note : Kinematic viscosity (not Dynamic viscosity) must be used to calculate Reynolds numbers.
It is generally accepted that the 'changeover' point between laminar flow and turbulent flow, in a
circular pipe, occurs when the Reynolds number (Re) is approximately 2100.
i.e. Laminar flow occurs when the Re is less than 2100. Turbulent flow occurs when the Re is greater
than 2100.
Friction Factors
Many formulas have been developed to model the flow of fluids. The Hazen-Williams formula has
been a popular method of estimating the head loss in piping systems for a number of years.
However, this empirical formula will only give reasonable accuracy if the fluid is water at 60°F or
similar. The Hazen-Williams formula is therefore not useful in analyzing a complex pipe system.
The Colebrook-White formula may be used with confidence to calculate an accurate friction factor
applicable to the turbulent flow of fluids. The Colebrook-White formula is applicable over a whole
range of fluid densities and viscosities, provided that the fluid flow is turbulent.
Colebrook-White Formula
The Colebrook-White formula:
f = friction factor
Re = Reynolds number
Friction factors for turbulent flow calculated by Pipe Flow Expert are based on the Colebrook-White
formula.
If the level of fluid (fluid head) is increased in a supply container, the volume of fluid entering the
system from the supply container will increase due to the increase in pressure (force).
168 Pipe Flow Expert User Guide
Darcy-Weisbach Formula
Fluid head resistance can be calculated by using the Darcy-Weisbach formula.
h fluid = f (L/D) x (v ²/2g)
f = friction factor
L = length of pipe work
D = inner diameter of pipe work
v = velocity of fluid
g = acceleration due to gravity
Fluid head loss calculated by Pipe Flow Expert is based on the Darcy-Weisbach formula.
In many systems where pipe lengths are relatively long, the effect of the fitting losses may be
considered to be minor losses, and could be ignored during initial assessment.
If a partially open valve is part of the design, the effect of the valve should always be considered as
the valve loss may be large.
Pipe Flow Expert has a database of valve and fittings ‘K’ factors and calculation wizards for:
• gradual enlargements
• gradual contractions
• sudden enlargements
• sudden contractions
• rounded entrances
• long pipe bends
For further information on this subject please refer to ‘Flow of Fluids through valves, fittings and pipe’
- Crane Technical Paper No. 410
Calculation Theory and Method of Solution 169
The Energy Grade Line is a plot of the sum of the three terms of the Work-Energy equation or
Bernoulli theorem: Fluid Head = The Kinetic energy + The Flow energy + The Potential energy.
v = velocity
g = acceleration due to gravity
P = pressure
y = fluid density
The Hydraulic Grade Line is a plot of the sum of two of the terms of the Bernoulli theorem: Fluid
Head = The Flow energy + The Potential energy.
P = pressure
y = fluid density
Mass flow into a joint in the network must be equal to mass flow out of the joint. Assuming that the
fluid density does not change, the total flow rate entering the node must equal the total flow rate
leaving the node.
The pressure drop in the pipes around a loop must be equal to zero. In a recirculation loop the
pressure loss in each pipe must be the total of the fluid head energy being provided by the driving
force (normally a pump). In a loop where the flows are in opposite directions, the total pressure loss
in each pipe with a clockwise flow must equal the total pressure loss in each pipe with an
anticlockwise flow.
Loops within a pipeline network consist of a series of connected pipes that return to the start point
(the node where the loop started), however pseudo loops can exist between a supply or discharge
source, between two supply sources or between two discharge sources.
Calculation Theory and Method of Solution 171
A series of pressure equations describing the pressure loss in each loop must be generated. The
same pipe may be included in many different loops.
Where a loop includes a number of different fluid zones the elevation differences of the nodes and
the density of the fluid in each pipe along the path in the loop must be used to establish the
difference in pressures due to fluid density at the end points of the loop. This pressure difference is
used together with the fluid surface pressure difference to establish the net pressure difference
around the loop.
A series of mass flow continuity equations must be generated for the mass flow rate balance at each
node in the pipeline system.
Pipe Flow Expert will automatically analyze a system, identify all loops and pseudo-loops, generate
the pressure equations throughout the network and remove redundant loop equations (those which
are already fully described by combining other equations). It will also generate the mass flow balance
equations for each node in a pipeline system.
An initial approximate solution is obtained using Linear Theory methods and an iterative approach to
adjust the flow rates until an approximate pressure balance is achieved.
An alternative approach is to use estimates for the out-flows and to use these estimates to set an
initial flow rate in each pipe, with the total in-flow to each join point matching the total out-flow from
each join point. The initial flow estimates are unlikely to give a balanced pressure result over the
whole system and must be further refined using an iterative approach to adjust the flow rates until an
approximate pressure balance is achieved.
Pipe Flow Expert defines the elements of the pipeline system in a series of matrix equations and
uses the Newton method to adjust the estimates for the flow rate in each pipe.
Once an approximate solution has been obtained, the results are refined using a variation of the
Newton method to ensure convergence until a balanced pressure result is obtained.
A flow balance tolerance and an approximate pressure balance tolerance are used to allow Pipe
Flow Expert to find an approximate solution quickly. This approximate solution is then refined until
the system is solved within the final pressure balance tolerance.
The flow and pressure balance tolerances and the maximum number of iterations allowed, have
been carefully chosen to provide the best overall performance in finding a solution. It is
recommended that these values are not changed, as most systems will solve without adjustment to
these parameters.
System Components
The user is able to enter the flow rate and head loss information about a component which is to be
included in the pipeline system. Pipe Flow Expert generates a performance curve for the component
to allow the effect of the component to be modeled.
Cv Flow Coefficients:
A Cv flow coefficient specifies the amount of water at 60°F (15.55 °C) in US gpm that will flow
through a valve and produce a 1.0 psi pressure drop. Thus a Cv flow coefficient of 10 indicates that a
1.0 psi pressure drop will occur with a 10 US gpm of water throughput through the valve.
The Cv flow coefficient of a control valve can be calculated from the flow rate and the pressure drop
through the valve. For liquids other than water the ratio of the fluid density to the density of water
must also be used in the calculation.
Calculation Theory and Method of Solution 173
Where:
Cv = flow coefficient
Q = flow rate in US gpm
∆P = pressure loss in psi across the valve
SG = the ratio of the fluid density to the density of water
With a known Cv flow coefficient the above formula can be re-arranged to calculate the pressure loss
for a particular flow rate thus:
Where:
Cv = flow coefficient
Q = flow rate in US gpm
∆P = pressure loss in psi across the valve
SG = the ratio of the fluid density to the density of water
The pressure loss through a fitting or valve may also be calculated from:
Where:
h fluid = head of fluid in ft.
K = flow coefficient of a valve or fitting
V = fluid velocity entering the fitting in ft/s
2
g = acceleration due to gravity in ft/sec
also
Where:
P = pressure in psi
h fluid = head of fluid in ft.
3
D = density of fluid in lbs/ft
Thus a 1.0 psi pressure drop is equivalent to 2.31 ft head of water at Normal Temperature &
3
Pressure (NTP) or 62.3 lbs/ft .
When a pipe diameter is known it is possible to establish a flow velocity from the Cv flow coefficient
in US gpm for a 1 psi pressure drop. Thus it is possible to calculate an equivalent fitting ‘K’ factor
which will produce the same pressure loss as the control valve Cv rating.
174 Pipe Flow Expert User Guide
Pipe Flow Expert uses the equivalent fitting ‘K’ factor method to model the flow and pressure loss
through a control valve where a Cv flow coefficient is used to specify the control valve characteristics.
A change to the pipe diameter would result in a change to the value of the equivalent fitting ‘K’ factor.
Pipe Flow Expert re-calculates the equivalent fitting ‘K’ factor for the current pipe diameter and the
fluid density at the start of the solution calculation.
The calculation helper provided on the Cv component dialog uses the flow rate and pressure loss
entered by the user, together with the current fluid density to calculate a Cv value to match the
specified requirements.
Kv Flow Coefficients:
3
A Kv flow coefficient specifies the amount of water at 20°C (68 °F) in m /hour that will flow through a
valve and produce a 1.0 bar pressure drop. Thus a Kv flow coefficient of 10 indicates that a 1.0 bar
3
pressure drop will occur with a 10 m /hour of water throughput through the valve.
The Kv flow coefficient of a control valve can be calculated from the flow rate and the pressure drop
3
through the valve. The density of the liquid in kg/m must also be used in the calculation.
Where:
Kv = flow coefficient
3
Q = flow rate in m /hr
∆P = pressure loss in bar across the valve
3
D = the density of the fluid in kg/m
3
1000 = the density of water in kg/m
With a known Kv flow coefficient, the above formula can be re-arranged to calculate the pressure
loss for a particular flow rate thus:
Where:
Kv = flow coefficient
3
Q = flow rate in m /hr
∆P = pressure loss in bar across the valve
3
D = the density of the fluid in kg/m
3
1000 = the density of water in kg/m
The pressure loss through a fitting or valve may also be calculated from:
Calculation Theory and Method of Solution 175
Where:
h fluid = head of fluid in meters.
K = flow coefficient of a valve or fitting
V = fluid velocity entering the fitting in m/s
2
g = acceleration due to gravity in meters/sec
also
Where:
P = pressure in bar
h fluid = head of fluid in meters
3
D = density of fluid in kg/m
2
g = acceleration due to gravity in meters/sec
When a pipe diameter is known it is possible to establish a flow velocity from the Kv flow coefficient
3
in m /hr for a 1 bar pressure drop. Thus it is possible to calculate an equivalent fitting ‘K’ factor which
will produce the same pressure loss as the control valve Kv rating.
Pipe Flow Expert uses the equivalent fitting ‘K’ factor method to model the flow and pressure loss
through a control valve where a Kv flow coefficient is used to specify the control valve characteristics.
A change to the pipe diameter would result in a change the matching equivalent fitting ‘K’ factor.
Pipe Flow Expert re-calculates the equivalent fitting ‘K’ factor for the current pipe diameter and the
fluid density at the start of the solution calculation.
The calculation helper provided on the Kv component dialog uses the flow rate and pressure loss
entered by the user, together with the current fluid density to calculate a Kv value to match the
specified requirements.
1.000 Kv = 1.156 Cv
The user should be aware that the Cv or Kv flow coefficient specifies the flow rate of water for a
particular pressure loss.
When the fluid density is greater or less than water, a different flow rate will be required to produce a
1.00 psi or a 1 bar pressure loss through the valve.
CAUTIONS:
Choked Flow:
If the fluid is a gas and the pressure drop exceeds 50% of the inlet pressure to the valve, the flow
will become choked and it will not be possible achieve the calculated flow rate.
Pipe Flow Expert does not model changes in the gas characteristics due to pressure or temperature
changes.
To correctly model the pressure drop for the entered Cv or Kv value the density of the gas used in
the calculation must be the density of the gas at the outlet of the valve/component.
176 Pipe Flow Expert User Guide
In effect this means that the fluid data for the fluid zone associated with the control valve must be
defined for the approximate pressure condition at the outlet of the valve/component.
The pressure drop for the gas flow rate through the valve, based on the entered Cv or Kv flow
coefficient and the fluid zone density in the pipe will be calculated.
The calculated pressure drop accounts for the effect of the expansion of the gas through the valve
since using the approximate fluid density of the gas at the valve outlet (as specified in the fluid zone
associated with the pipe) during calculation of the solution, caters for this characteristic.
If the fluid zone associated with the control valve does not represent the pressure condition at the
outlet of the valve/component, it may be necessary to use an adjusted Cv (or Kv) value for valve
selection to take in to account the effect of the gas expansion.
The adjusted Cv (or Kv) value should be based on the Cv or Kv formula for sub critical gas pressure
drop.
A simplified version of the Cv formula for sub critical gas pressure drop is shown below:
Where:
Cv = flow coefficient
3
SCFH = flow rate in ft /hr (NTP)
3
Dn = the gas density in lbs/ft at 0.00 psig
o
F = gas temperature
∆p = pressure loss in psi absolute
po = valve outlet pressure in psi absolute
A simplified version of the Kv formula for sub critical gas pressure drop is shown below:
Where:
Kv = flow coefficient
3
Q = flow rate in m /hr (NTP)
3
Dn = the gas density in kg/m at 0.00 barg
o
C = gas temperature
∆p = pressure loss in bar absolute
po = valve outlet pressure in bar absolute
Please refer to an appropriate text book for a more detailed formula to take account of piping
geometry or gas compressibility, should this be necessary.
Calculation Theory and Method of Solution 177
The Cv (or Kv) flow coefficient of a control valve is usually stated for the fully open flow condition.
The Cv (or Kv) flow coefficient will be less when the valve is partly closed.
In an actual system it is important to select a control valve which has an appropriate Cv (or Kv) flow
coefficient for the actual valve position that will be used. A control valve that is too small or too large
will never be able to provide the correct control in a system.
Most control valve manufactures recommend that you should select a valve where the required Cv
(or Kv) value falls between 20% - 80% of the port opening.
Some control valve manufactures recommend that an allowance of 30% should be added to the
calculated Cv (or Kv) flow coefficient to obtain the minimum full flow Cv (or Kv) flow coefficient rating
which the selected valve should have (when fully open).
Please check your control valve selection with the control valve manufacturer.
No other pipe which connects to a pipe with a Flow Control Valve fitted can contain a control valve
(FCV, PRV or BPV).
The pressure difference between the ‘From node’ and the ‘To node’ must equal the pressure loss
introduced by the flow control valve plus the pressure loss that the flow in the pipe will produce, plus
the pressure loss that any other component on the pipe produces. The system balance will be
maintained when the pipe is reinstated along with the pressure loss introduced by the flow control
valve.
If the pressure difference between the ‘From node’ and the ‘To node’ is not great enough then the
pressure loss in the pipe and the flow control valve pressure loss cannot be set. A warning will be
displayed that the pressure in the pipe is not sufficient to deliver the set flow.
178 Pipe Flow Expert User Guide
A pipe with a Pressure Reducing Valve fitted cannot have a tank or pressure demand set on either
end. No other pipe which connects to a pipe with a Pressure Reducing Valve fitted can contain a
control valve (FCV, PRV or BPV).
Pipe Flow Expert removes the pipe from the system and sets the pressure at the downstream node
(N2) by replacing it with an appropriately defined tank. The tank elevation is set to equal the node
elevation, the liquid level is set to zero and the fluid surface pressure is set to the pressure reducing
valve setting. At the upstream node, an out-flow demand is then set equal to the flow from N2.
Hence the pipe is replaced by a tank at the downstream node and an out-flow at the upstream node
while the system is being solved. The outflow at the upstream node must equal the flow rate from the
downstream node that is now represented by the tank.
The pressure difference between the upstream node P1 and the downstream node P2 must equal
the pressure loss through the pipe, fittings and any components on the pipe plus the pressure loss
introduced by the PRV. The pressure balance is then maintained after the system is solved, when
the pipe is reinstated along with the pressure loss introduced by the pressure reducing valve.
MODES OF OPERATION: A PRV can operate under three different conditions: (1) regulating, (2)
fully closed, and (3) fully open. How the valve operates depends on the defined set pressure value
for the valve. The fully open and fully closed positions represent the extreme operations of the valve.
Each of the valve positions is described below:
(1) Regulating The valve maintains the downstream pressure to the set value by introducing a
pressure loss across the valve, thus throttling the flow rate through the PRV.
(2) Fully Closed This mode of operation occurs if the valve’s set pressure is less than the
pressure downstream of the valve for the case where the valve is closed. When
this occurs in an actual pipe system, the flow through the PRV reverses and the
PRV acts as a check valve, closing the pipe. In PipeFlow Expert, this method of
operation is detected and reported but the system is not then solved for this
scenario. The user must decide if this method of operation is what they intended
and if so then they can close the pipe and continue to solve the system.
(3) Fully Open This mode of operation occurs if the valve’s set pressure is greater than the
pressure upstream of the valve for the case where the valve is fully open. When
this occurs in an actual pipe system, the PRV maintains a fully open position
and it has no effect on the flow conditions (except to add a frictional loss through
Calculation Theory and Method of Solution 179
Pipe Flow Expert will only solve a system when the PRV is operating in Regulating mode.
AVOIDING PRV OPERATION PROBLEMS: In general, PRV operation problems can be avoided by
finding the valve's pressure regulating range and specifying the valve’s set pressure to a value within
this range, such that the mode of operation is ‘Regulating’. First, solve the system without the PRV
control and note the pressure at the node downstream of the pipe which previously contained the
PRV. This is the maximum pressure the PRV can be set to (i.e. it is equivalent to finding the valve’s
inlet pressure for the case where the valve is fully open). Secondly, solve the system after closing
the pipe that contains the PRV and note the pressure at the node downstream of the closed pipe.
This is the minimum pressure the PRV can be set to (i.e. it is equivalent to finding the pressure
downstream of the valve for the case where the valve is fully closed).
A pipe with a Back Pressure Valve fitted cannot have a tank or pressure demand set on either end.
No other pipe which connects to a pipe with a Back Pressure Valve fitted can contain a control valve
(FCV, PRV or BPV).
Pipe Flow Expert removes the pipe from the system and sets the pressure at the upstream node
(N1) by replacing it with an appropriately defined tank. The tank elevation is set to equal the node
elevation, the liquid level is set to zero and the fluid surface pressure is set to the back pressure
valve setting. . At the downstream node, an in-flow demand is then set equal to the flow into the
upstream node N1. Hence the pipe is replaced by a tank at the upstream node and an in-flow at the
downstream node while the system is being solved. The in-flow at the downstream node must equal
the flow rate into the upstream node that is now represented by a pressurized tank.
The pressure difference between the upstream node P1 and the downstream node P2 must equal
the pressure loss through the pipe, fittings and any components on the pipe plus the pressure loss
introduced by the BPV. The pressure balance is then maintained after the system is solved, when
the pipe is reinstated along with the pressure loss introduced by the pressure reducing valve.
180 Pipe Flow Expert User Guide
MODES OF OPERATION: A BPV can operate under three different conditions: (1) regulating, (2)
fully closed, and (3) fully open. How the valve operates depends on the defined set pressure value
for the valve. The fully open and fully closed positions represent the extreme operations of the valve.
Each of the valve positions is described below:
(1) Regulating The valve maintains the upstream pressure to the set value by introducing a
pressure loss across the valve, thus reducing the flow rate through the BPV.
(2) Fully Closed This mode of operation occurs if the valve’s set pressure is greater than the
pressure upstream of the valve for the case where the valve is closed. When
this occurs in an actual pipe system, the flow through the BPV reverses and the
BPV acts as a check valve, closing the pipe. In PipeFlow Expert, this method of
operation is detected and reported but the system is not then solved for this
scenario. The user must decide if this method of operation is what they intended
and if so then they can close the pipe and continue to solve the system.
(3) Fully Open This mode of operation occurs if the valve’s set pressure is less than the
pressure downstream of the valve for the case where the valve is fully open.
When this occurs in an actual pipe system, the BPV maintains a fully open
position and it has no effect on the flow conditions (except to add a frictional
loss through the valve). In PipeFlow Expert, this method of operation is detected
and reported but the system is not solved because the differential pressure
across the valve would have to be negative, i.e. the valve would be acting like a
pump rather than a pressure control.
Pipe Flow Expert will only solve a system when the BPV is operating in Regulating mode.
AVOIDING BPV OPERATION PROBLEMS: In general, BPV operation problems can be avoided by
finding the valve's pressure regulating range and specifying the valve’s set pressure to a value within
this range, such that the mode of operation is ‘Regulating’. First, solve the system without the BPV
control and note the pressure at the node upstream of the pipe which previously contained the BPV.
This is the minimum pressure the BPV can be set to (i.e. it is equivalent to finding the pressure at the
valve outlet for the case where the valve is fully open). Secondly, solve the system after closing the
pipe that contains the BPV and note the pressure at the node upstream of the closed pipe. This is
the maximum pressure the BPV can be set to (i.e. it is equivalent to finding the pressure at the valve
inlet for the case where the valve is fully closed).
and an equal In-flow demand at the ‘To node’. The pipe and the pump are replaced by these flow
demands while the system is being solved.
Since the head pressure provided by the pump is unknown, the system balance cannot be ‘tuned’ by
iterating along the pump performance curve. For this reason it is not possible to include pressure
control devices such as flow control valves on all outlet paths through the system when a fixed flow
rate pump has been selected (this would result in an over-controlled system).
Two-phase flow can produce an extremely high pressure drop many times greater than the pressure
drop of either individual fluid. The user should make due allowance for the two-phase flow pressure
drop by using a component to add an appropriate additional pressure loss.
Slurries
Slurries which have a constant density and a constant viscosity are able to be modeled, provided the
minimum velocity to keep the solids in suspension is maintained throughout the pipeline system. The
density and viscosity of the slurry mixture must be entered as the fluid data.
182 Pipe Flow Expert User Guide
The system calculations do not take account of any compression or expansion of the fluid that may
occur due to pressure changes in the fluid and therefore the results obtained for compressible fluids
may only be acceptable under certain conditions.
It is however common practice for the Darcy-Weisbach equation to be used to calculate the friction
losses for compressible fluids within a pipeline system, if certain constraints about the system being
modeled are understood.
It is up to the pipe systems engineer to be familiar with good engineering practice and to use their
own judgment about the accuracy of results for a system that contains a compressible fluid.
The Pipe Flow Expert software is intended for general use with either liquids or gases (subject to
certain criteria for gas systems).
Pipe Flow Expert uses the Colebrook-White equation to calculate friction factors. Pipe Flow Expert
uses the Darcy-Weisbach equation to calculate friction loss in a pipe.
These equations assume a constant fluid density & viscosity and they provide a very accurate
solution when working with none compressible fluids (liquids).
When using the software to model gas systems there are certain criteria that the model must operate
within to ensure the solution is of acceptable accuracy.
Changes in pressure and temperature will affect the gas density and viscosity. These property
changes affect the actual pressure drop and are not automatically accounted for in the Darcy-
Weisbach equation, therefore some limitations must be applied to ensure that the calculated results
are within an acceptable accuracy.
Where the pressure loss is less than 10% of the highest absolute pressure in the system, if the
pressure drop is calculated using the entering fluid density then good reliability of the results can be
expected.
Where the pressure loss is more than 10% but less than 40% of the highest absolute pressure in the
system, if the pressure drop is calculated using the average fluid density then good reliability of the
results can be expected.
Working with Compressible Fluids 183
Where a system has a total pressure loss which exceeds 40% of the highest absolute pressure in
the system, it is necessary to model the system using different fluid zones. Up to 20 fluid zones can
be used in a Pipe Flow Expert model.
Where a system has been split into a number of separate fluid zones, the fluid density and the fluid
viscosity for each fluid zone should be set independently.
The density of each fluid zone in the system must reflect the average density of the compressed fluid
condition in that fluid zone.
When a system is solved if the fluid density is not within 5% of the average fluid density for a
particular zone, a warning will be issued in the results log. Suggestions to Update Fluid Zone Data to
have a particular density based on the average pressure within the fluid zone will be issued in the
results log.
General Suggestions:
For systems that contain compressible fluids the following should be noted
The mass flow rates entering the system and the mass flow rates leaving the system must be
balanced. Normally In-Flow or Out-Flow values are entered using a mass flow rate units, such as
lb/sec, lb/min, lb/hour, kg/sec, kg/min or kg/hour, for a system which involve compressible fluids.
Where volumetric In-Flow rates entering the system have to be used these values must be entered
as the ‘actual’ flow rate of the fluid for that particular fluid zone applicable to the pipe from which the
fluid will enter, i.e. the flow rate of the fluid must be based on the density of the fluid zone (and not on
the uncompressed volumetric flow rate of the fluid).
Where volumetric Out-Flow rates leaving the system have to be used these values must be entered
as the ‘actual’ flow rate of the fluid for that particular fluid zone applicable to the pipe from which the
fluid will leave, i.e. the flow rate of the fluid must be based on the density of the fluid zone (and not
on the uncompressed volumetric flow rate of the fluid).
The pressure at all In-Flow points for an individual fluid zone must be the same to the degree that the
pressure does not change the volume and density of the fluid zone significantly.
Devices which change the volume/density of the fluid should not be included as part of the system
analysis.
Pipe Flow Expert uses a constant value for the compressible fluid density throughout each individual
fluid zone in the pipeline system. Where volumetric flow rates are used to specify the In-Flows and
Out-Flows to the system, the individual density for each fluid zone is used to convert from volumetric
flow rate units to the mass flow rate units used internally by Pipe Flow Expert. The calculations are
performed using the mass flow rates to achieve mass flow rate continuity and balance within the
pipeline system. The results are then converted back to the appropriate volumetric units for each
pipe, based on the fluid zone data associated with the pipe.
The effects of pressure changes and temperature changes on the fluid density are not modeled.
Note 1:
The Fluid density at the compressed fluid condition can be calculated using the normal density of the
compressible fluid and the fluid pressure.
Note 2:
The Actual flow rate of the fluid at the compressed fluid condition can be calculated using the
uncompressed volume of the fluid and the fluid pressure.
Example: If a flow of 10 m³/s of air at normal temperature and pressure is compressed to 6 bar g
the Actual flow rate would be:
10 x 1.01325 / (6.000 +1.01325) = 1.445 m³/s
Glossary 185
Glossary
Term Description
Absolute
Pressure measured with respect to zero pressure.
pressure
Atmosphere A standard atmospheric pressure of 1.01325 bar a or 14.696 psi a.
Centipoise Absolute viscosity of a fluid expressed in Pa • s x 10-3
Kinematic viscosity of a fluid expressed in m²/s x 10-6
Centistokes Note: Pipe Flow Expert requires fluid viscosity to be entered in
Centipoise.
An equation used to calculate accurate friction factors from the
Colebrook-White
internal diameter and internal roughness of a pipe and the Reynolds
equation
number for the flow conditions.
An equation used to calculate the frictional head loss due to fluid flow
Darcy-Weisbach
from the friction factor, the length and diameter of the pipe, the
equation
velocity of the fluid and the gravitational constant.
Demand flow The In-Flow entering the system or the Out-Flow leaving the system.
Demand
The pressure at a point of exit from the system.
pressure
Discharge Out-Flow leaving the system.
Dynamic
The absolute viscosity of a fluid.
viscosity
A factor to be used in the Darcy-Weisbach equation. Either calculated
Friction factor
from the Colebrook-White equation or read from the Moody diagram.
Elevation The height above sea level of a node or tank.
End pressure The pressure at a point where fluid leaves the system.
Fixed pressure A static pressure loss which is independent of the flow rate.
Fluid head The resistance to flow expressed in height of fluid as a motive force.
Gage pressure Pressure measured with respect to atmospheric pressure.
Hydraulic grade The pressure at a point in the system expressed in height of fluid plus
line the elevation above sea level of the node or the tank.
in Hg Height of a column of mercury in a barometer expressed in inches.
K value Coefficient of frictional loss through valve or pipe fittings.
Kinematic
The absolute viscosity of a fluid divided by the fluid density.
viscosity
A graphical representation of the relationship between Reynolds
Moody diagram
number, relative roughness and Friction factor.
Height of a column of mercury in a barometer expressed in
mm Hg
millimeters.
NPSHa Net Positive Such Head available.
NPSHr Net Positive Such Head requirement.
The friction loss due to fluid flow expressed in fluid head or Gage
Pressure loss
pressure.
The motive force developed by a pump expressed in height of fluid.
Pump head
(Pump performance graphs usually show pump head for water).
Relative A dimensionless number expressing the internal roughness of a pipe
roughness divided by the internal diameter of a pipe.
Reynolds A dimensionless number derived from the fluid velocity, the internal
number diameter of the pipe and the Kinematic viscosity of the fluid.
Supply In-Flow entering the system.
Vapor pressure The absolute pressure at which a liquid will start to evaporate.
A measure of a fluid‘s resistance to flow. See absolute viscosity and
Viscosity
Kinematic viscosity.
186 Pipe Flow Expert User Guide
Index
Adding Text Items, 136 creating
Adding Text to the Drawing, 136 pipe systems, 62
Automatic Checks and Updates, 153 Cv flow coefficient, 174
Cv Flow Coefficient, 43
back pressure valves, 181 Cv Flow Coefficients, 106
adding, 112 Cv Value, 174
understanding, 112 Cv Values, 106
balanced flow state, 172
BPV Darcy-Weisbach Formula, 170
adding, 109 Daxesoft Ltd.
contacting, 15
Calculating and Solving Defining Fluid Zones, 81
calculating, 154 demand flows
calculating pipe system results, 152 adding, 132
calculation theory, 168 deleting, 149
Change attributes of more than one node, 77 understanding, 132
Change attributes of more than one pipe, 75 demand in-flows
Change the system view, 64 adding, 132
Changing the fluid Density and Viscosity, 81 demand out-flows
choosing item labeling, 69 adding, 132
choosing pipe drawing defaults, 71 demand pressures
choosing system units, 70 adding, 134
Choosing units, 68 deleting, 148
Colebrook-White Formula, 169 understanding, 134
Component Pressure Loss, 43 Documentation Menu, 24
component pressure losses Drawing Menu, 22
deleting, 150 Drawing pane, 47
more than one on a pipe, 103 cutting, copying, and pasting nodes, 145
components inverted view, 140
adding, 103 mirror view, 140
adding, 103 moving components, 144
pressure loss, 103 panning pipe system, 139
understanding, 103 undo and redo functions, 148
Compressed fluid condition view whole of the pipe system, 139
Actual flow rate, 187 zoom in, 138
fluid density, 186 zoom out, 138
compressible fluids, 185
considerations, 185 Edit Menu, 19
computer minimum requirements, 12 end pressure. See demand flows, See demand
Configuration Options flows
Labelling Tab, 49 End Pressure Data, 32
Units Tab, 51
Configuration Options Calculations Tab, 57 FCV
Configuration Options Pipe Default Values Tab, adding, 109
53 File Menu, 17
Configuration Options Screen, 49 fitting head loss, 170
configuring fittings
calculation parameters, 79 adding, 97
results, 152, 158 adding to the database, 99
Control Valve Data, 44 deleting, 150
control valves Fixed flow rate pump
deleting, 151 Limited application, 116
Copying between drawing, 146 flow control valves, 179
Create a PDF Report, 165 adding, 110
understanding, 110
Index 187