100% found this document useful (1 vote)
680 views2 pages

Guard House

The document provides structural design criteria for a guard house project, including design codes, dead and live loads for the ground floor and metal roof, wind loads, and load combinations. The dead and live loads are specified according to various British Standards and Malaysian Standards. Load combinations are also listed following standard formulas.

Uploaded by

Kevin Low
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
680 views2 pages

Guard House

The document provides structural design criteria for a guard house project, including design codes, dead and live loads for the ground floor and metal roof, wind loads, and load combinations. The dead and live loads are specified according to various British Standards and Malaysian Standards. Load combinations are also listed following standard formulas.

Uploaded by

Kevin Low
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Project: Ajinomoto - Guard House 22 September, 2019

STRUCTURAL DESIGN CRITERIA

Design Codes
British Standard, BS 8004-1986, Code of Practice for Foundations
British Standard, BS 8007:1987, Code of Practice for Design of Concrete
Structures for Retaining Aqueous Liquids
British Standard, BS 8110-1:1997, Structural Use of Concrete -
(Part 1 : Code of Practice for Design and Construction)
British Standard, BS 5950-1:2000, Structural Use of Steelwork in Building -
(Part 1 : Code of Practice for Design - Rolled and Welded Sections)
British Standard, BS 6399-1:1996, Loading for Buildings -
(Part 1 : Code of Practice for Dead and Imposed Loads)
British Standard, BS 648:1964, Schedule of Weights of Building Materials
Malaysian Standard, MS 1553:2002,
Code of Practice on Wind Loading for Building Structure
Project: Ajinomoto - Guard House 22 September, 2019

STRUCTURAL DESIGN CRITERIA

Ground Floor
Dead Loads
2
Floor 1.2 kN/m

Live Loads (BS 6399-1: 1996 and BS 6399-3: 1988)


2
Floor 5 kN/m

Metal Roof
Dead Loads (BS 5950-1:2000)
2
Metal Roofing & Purlin 0.5 kN/m

Live Loads (BS 6399-1: 1996 and BS 6399-3: 1988)


2
Roof Live Loads (without access) 0.25 kN/m

Wind Loads (MS 1553 : 2002)


2
Wind Load 0.65 kN/m

Load Combinations
1.4G+1.6Q
1.2G+1.2Q+1.0Nx
1.2G+1.2Q-1.0Nx
1.2G+1.2Q+1.0Ny
1.2G+1.2Q-1.0Ny
1.2G+1.2Q+1.2W
1.2G+1.2Q-1.2W