Functional Change of Sac Into Iac: Standard Field Operating Procedure
Functional Change of Sac Into Iac: Standard Field Operating Procedure
FUNCTIONAL CHANGE
OF SAC INTO IAC
INDEX
1. OBJECTIVE
2. SCOPE
3. INTRODUCTION
4. RESPONSIBILITY
5. SAFETY PRECAUTIONS
6. SAFETY PPE’S
7. STEPS FOLLOWED
8. ABBREVIATIONS
1. OBJECTIVE:
Smooth functional change of SAC in IAC.
2. SCOPE:
This SOP is applicable for 4 no. of Service air Compressor.
3. INTRODUCTION:
During the emergency condition when IAC is not available for any
reason we can produce instrument air from service air compressor
using the dryer of IAC and compressor of SAC. Changeover is only
possible in the connected Instrument air compressor and service air
compresssor i.e. between (IAC A & SAC A), (IAC B & SAC B), (IAC C &
SAC C) and (IAC D & SAC D).
4. RESPONSIBILITY:
Unit Control Engineer, Desk Engineer and Field Operator.
5. SAFETY PRECAUTIONS:
Field Operator ensures no permit to work is pending on regarding this
system by checking with CCR.
6. SAFETY PPE’S:
Ear Plugs, Safety Goggles, Hand Gloves, etc.
7. STEPS FOLLOWED
STEP 1:- Close SAC A service air outlet valve.