Structural Design Report
CONTENT
Structural Design Report
1. INTRODUCTION
Mr. Abdul sought the assistance to conduct a design report for the two story structure. This
report is to elaborate the design calculations and cross sections. Design was conducted
according to euro code standards.
3.0 PRELIMINARIES
Loads were extracted from the given structural drawings and summary of loads are
mentioned in Table 1.
Dead Loads
Self-weights were derived based on elements dimensions and material properties. The
super imposed dead loads and live loads were assessed based on the floor usage and
architectural floor plans of the building.
Live Loads
Live Loads were defined according to the provided structural drawings and by verifying with
the eurocode standards.
Loading Combinations
Total Dead Load (DL) was calculated from the sum of self-weight of element and
corresponding superimposed loads. Live load (LL) was calculated with corresponding live load
value. Ultimate Loading Combination According to Australian code was taken as follows.
Dead Loads
Finishers = 1 kN/m2
Live Loads
Residential = 2 kN/m2
Structural Design Report
ANALYSIS
Geometry
Geometry (m) - Steel (EC3) - UKC 203x203x46
Self Weight
Permanent
Imposed
Load combination
;
Partial factors - Section 6.1
Resistance of cross-sections; M0 = 1
Resistance of members to instability; M1 = 1
Resistance of tensile members to fracture; M2 = 1.1
B1 - Span 1 design
Section details
Section type; UKC 203x203x46 (Tata Steel Advance)
Steel grade - EN 10025-2:2004; S275
Nominal thickness of element; tnom = max(tf, tw) = 11 mm
Nominal yield strength; fy = 275 N/mm2
Nominal ultimate tensile strength; fu = 410 N/mm2
Modulus of elasticity; E = 210000 N/mm2
Structural Design Report
Lateral restraint
Both flanges have lateral restraint at supports only