Pump - Speed Torque Curve

This document contains speed-torque curves and specifications for a closed drain pump. The maximum torque is 20.01 Nm at startup and the required starting torque is also 20.01 Nm. The maximum torque at 143 rotations per minute is 8.15 Nm. The pump is designed to pump hydrocarbon liquids or water and has a plunger diameter of 36mm.

Uploaded by

Mostafa El Sayed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
152 views

Pump - Speed Torque Curve

This document contains speed-torque curves and specifications for a closed drain pump. The maximum torque is 20.01 Nm at startup and the required starting torque is also 20.01 Nm. The maximum torque at 143 rotations per minute is 8.15 Nm. The pump is designed to pump hydrocarbon liquids or water and has a plunger diameter of 36mm.

Uploaded by

Mostafa El Sayed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

CLOSED DRAIN PUMP - SPEED TORQUE CURVE

torque [Nm] result of torque calculation


20
start-up torque
15 max. torque 20.01 Nm
mean torque 9.19 Nm
10
max min. torque -0.05 Nm
mid
min
torque at 143 1/min
5
max. torque 8.15 Nm
mean torque 3.05 Nm
0
min. torque -0.71 Nm
200 400 600 800 1000 1200 1400
rotational speed of the fast shaft [1/min]
torque at 143 1/min
torque [Nm] max. torque 8.15 Nm
8 mean torque 3.05 Nm
min. torque -0.71 Nm
6

4
max
Required Starting Torque : 20.01 Nm
2 Required Torque : 4.07 Nm
Required Power : 0.61 kW
0 Absorbed Power : 0.41 kW
100 200 300 Absorbed Power : 0.46 kW
rotation angle of the crankshaft [°]

fluid hydrocarbon liquid / water


element
drive unit LDE
i 10
eccentricity 0
plunger diameter [mm] 36
volumetric efficiency[%] 94.28
max. operating pressure [bar] 29.0
PSV set pressure [bar] 34.8
internal PRV set pressure [bar] 0.0