Design of T-Beam

1) A tee beam with a 150mm thick slab spanning 3m is designed. The beam has an 8m effective span and carries a 4kN/m2 live load. 2) The beam is designed as a singly reinforced rectangular section with M20 concrete and Fe415 steel. 3) The required bottom reinforcement is calculated as 2-25mm bars and 1-32mm bar. Stirrups of 2 legged 10mm bars at 300mm spacing are sufficient for shear.

Uploaded by

Dinesh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
551 views

Design of T-Beam

1) A tee beam with a 150mm thick slab spanning 3m is designed. The beam has an 8m effective span and carries a 4kN/m2 live load. 2) The beam is designed as a singly reinforced rectangular section with M20 concrete and Fe415 steel. 3) The required bottom reinforcement is calculated as 2-25mm bars and 1-32mm bar. Stirrups of 2 legged 10mm bars at 300mm spacing are sufficient for shear.

Uploaded by

Dinesh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

EX.NO: 8 NAME : S.

DINESH KUMAR
26/09/19 DESIGN OF T-BEAM REG NO : 122105003

1)A tee beam of an office comprises of a slab 150 mm thick spanning between ribs spaced at 3 m
centers. The effective span of the beam is 8 m. Live load on floor is 4 kN/m2. Using M-20 grade
concrete and Fe415 HYSD bars, design one of the intermediate tee beam.

S.No Description Notation Relation Value Unit Remarks

Given Data:
Effective span L = 8m
Effective breadth of flange B = 3m
Depth of flange df = 150 mm
Live load wL = 4 kN/m
2
Grade of concrete fck = 20 N/mm
2
Grade of steel fy = 415 N/mm

1) SETTING OF DIMENSIONS:

Assume, L/d = 15 → d = L/15 → d = 0.53333333 ≈ 550 mm


Effective cover d' = 50 mm (Assume)
Overall depth of beam D = 600 mm (D=d+d')
Depth of web dw = 450 mm (dw=D-df )
Breadth of web b = 300 mm ( b=D/2 )

2) LOAD CALCULATION:

i) Self weight of the flange (df Bϒc) = 11.25 kNm (ϒc →25kN/m3)
ii) Self weight of the web (dw bϒc) = 3.375 kNm
iii) Live load (BwL) = 12 kN/m
iv) Finishing load FL = 1.375 kN/m
v) Total load w = 28 kN/m

Factored load wu = 42 kN/m (PSF=1.5)

3) CALCULATION OF BENDING MOMENT AND SHEAR FORCE:

Bending moment Mu = 336 kNm (wuL2/8)


Shear force Vu = 168 kN (wuL/2)

4) DETERMINATION OF TYPE OF DESIGN:

Muf = 0.36 fck Bdf (d-0.42df ) → Muf = 1577.88 kNm


Since, Mu < Muf → it must be designed as a Rectangular section.
For Fe415, Mu,lim = 0.138 fck Bd2 → Mu,lim = 2504.7 kNm
Since, Mu < Mu,lim → it must be designed as a Singly Reinforced Beam.
S.No Description Notation Relation Value Unit Remarks

5) CALCULATION OF STEEL REQUIRED:

Mu = 0.87 fy Ast d(1-[(Ast fy)/(Bd fck)]) → ( fy/fck B )Ast2 - dAst + ( Mu/0.87fy ) = 0 → ①


a = 0.006916667 b= -550 & c= 930619
2
By solving the quadratic equation, Ast1 = 1729.6576 & Ast2 = 77788.4 mm

6) PROVISION OF STEEL REINFORCEMENT:

2
Ast,min = (0.85 bd)/fy → Ast,min = 337.951807 mm (Ast,m=1730)
2
Ast,max = 0.04 bD → Ast,max = 7200 mm
2
Therefore, Ast,req = 1729.65763 mm (Astmin<Ast1)

2 2 2
dia: 25mm → 490.9 mm (2 nos) = 981.746875 mm (ast = ∏d /4)
2 2
dia: 32mm → 804.25 mm (1 nos) = 804.24704 mm
2
1785.99392 mm

Therefore, provide 2 - 25mm Ø bars and 1 - 32mm Ø bars in the bottom.


2
Therefore, Ast,pro = 1785.99392 mm

7) CHECK FOR SHEAR:

2
Ʈv = Vu/bd → Ʈv = 0.00101818 kN/mm
Pt = 100 Ast ,pro/bd Pt = 1.08242055 %
2
From Table 19, for the obtained Pt , Ʈc = 0.63 kN/mm

Since, Ʈv < Ʈc → No shear reinfotrcement is needed.


Therefore, provide 2 - legged 10mm Ø stirrups @ 300 mm spacing.

8) DEFLECTION CHECK:

To be safe, (L/d)act < (L/d)base kt kc kf


For this problem, kc = 1 & for simply supported beams, (L/d)base =20

2
fs = 0.58 fy Ast,req / Ast,pro fs = 233.107508 N/mm
For the obtained Pt and fs values, kt = 0.95
b/B = 0.1
For the obtained ( b/B ) value, kf = 0.8

Therefore, (L/d)max = 15.2


(L/d)act = 14.5454545

Since, (L/d)act < (L/d)max → The beam is safe under deflection crieteria.
S.No Description Notation Relation Value Unit Remarks

9) DESIGN OF FLANGED PORTION:

2
Bending moment mu = 31.5 kNm (mu= wuB /12)
By using mu instead of Mu in ① ,

mu = 0.87 fy Ast d(1-[(Ast fy)/(1000d fck)]) → ( fy/1000fck )Ast2 - dAst + ( mu/0.87fy ) = 0


a = 0.02075 b= -550 & c= 87245.5
2
By solving the quadratic equation, Ast1 = 159.6 & Ast2 = 26346.5 mm

Ast,min = 0.12% of bdf Ast,min = 180 mm2


2
Therefore, Ast,req = 180 mm

Spacing of reinforcement S = (ast/Ast) X 1000


2
dia: 8mm → 50.3 mm S = 279.252444 mm (ast = ∏d2/4)
2
dia: 10mm → 78.54 mm S = 436.331944 mm

Therefore, provide 10mm Ø bars @ 300mm spacing in the shoter span direction and the same as
distribution reinforcement.
2
Therefore, Ast,pro = 261.799167 mm

10) DESIGN SUMMARY: (M20 Concrete & Fe415 Steel)

CONCRETE T- BEAM DETAILS:

Effective span L = 8 m
Effective breadth of flange B = 3 m
Depth of flange df = 150 mm
Effective cover d' = 50 mm
Overall depth of beam D = 600 mm
Depth of web dw = 450 mm
Breadth of web b = 300 mm

REINFORCEMENT DETAILS:

Main reinforecement : Provide 2 - 25mm & 1 - 32mm Ø bars in the bottom.


Hanger bars : Provide 2 - 12mm Ø bars in the top.
Shear reinforceement : Provide 2 - legged 8mm Ø stirrups @ 300 mm spacing.
Slab reinforcement: Provide 10mm Ø bars @ 300mm spacing in both directions.
`

You might also like