100% found this document useful (1 vote)
3K views

AISC Design Guide 03 - Serviceability Design Considerations For Steel Buildings - 2Nd Edition

The document provides serviceability recommendations and deformation limits for various structural elements and cladding types including metal panels, precast walls, masonry walls, curtain walls, ceilings, partitions, equipment, and cranes. Maximum drift, deflection, and movement values are provided for elements under different load cases including wind, snow, dead, and live loads. The recommendations aim to limit cracking, damage, and vibration for a 10 or 50 year design life.

Uploaded by

Adnan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
3K views

AISC Design Guide 03 - Serviceability Design Considerations For Steel Buildings - 2Nd Edition

The document provides serviceability recommendations and deformation limits for various structural elements and cladding types including metal panels, precast walls, masonry walls, curtain walls, ceilings, partitions, equipment, and cranes. Maximum drift, deflection, and movement values are provided for elements under different load cases including wind, snow, dead, and live loads. The recommendations aim to limit cracking, damage, and vibration for a 10 or 50 year design life.

Uploaded by

Adnan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

SERVICEABILITY CONSIDERATIONS

CLADDING

CLADDING
STRUCTURAL RECOMMEN-
SUPPORT DEFORMATION LOADING
ELEMENT DATION
TYPE
DRIFT
METAL PANELS / H / 60 TO H/ 100
PERPENDICULAR 10 YEAR WIND
BARE FRAME MAXIMUM
TO WALL

METAL PANELS / HORIZONTAL L / 120


10 YEAR WIND
GIRTS DEFLECTION MAXIMUM

METAL PANELS / HORIZONTAL L / 120


10 YEAR WIND
WIND COLUMNS DEFLECTION MAXIMUM

FOUNDATION DRIFT
PRECAST WALLS / H / 100
PERPENDICULAR 10 YEAR WIND
BARE FRAME MAXIMUM
TO WALL
UNRIENFORCED DRIFT
1 / 16 IN. CRACK
MASONRY WALLS / PERPENDICULAR 10 YEAR WIND
BASE OF WALL
BARE FRAME TO WALL
RIENFORCED DRIFT
H / 200
MASONRY WALLS / PERPENDICULAR 10 YEAR WIND
MAXIMUM
BARE FRAME TO WALL

MASONRY WALLS / HORIZONTAL L / 240 ≤ 1.5 IN.


10 YEAR WIND
GIRTS DEFLECTION MAXIMUM

MASONRY WALLS / HORIZONTAL L / 240 ≤ 1.5 IN.


10 YEAR WIND
WIND COLUMNS DEFLECTION MAXIMUM

MASONRY WALLS / VERTICAL L / 600 ≤ 0.3 IN.


DL + LL
LINTEL DEFLECTION MAXIMUM

MASONRY WALLS / ≤ 1 DEGREE


ROTATION DL + LL
LINTEL MAXIMUM

PRE-ASSEMBLED RELATIVE 1 / 4 IN.


UNITS / COLUMNS SHORTENING MAXIMUM 0.5 × LL
COLUMN

PRE-ASSEMBLED
UNITS / BARE RACKING H / 500 10 YEAR WIND
FRAME

CURTAIN WALLS /
RACKING H / 500 10 YEAR WIND
BARE FRAME

CURTAIN WALLS / VERTICAL 3 / 8 IN. DL PRIOR TO


SPANDREL
SPANDRELS DEFLECTION MAXIMUM CLADDING

CURTAIN WALLS / VERTICAL L / 480 ≤ 5 / 8 IN.


TOTAL DL
SPANDRELS DEFLECTION MAXIMUM

L / 360
CURTAIN WALLS / VERTICAL
SPANDRELS DEFLECTION
≤ 1 / 4 - 1 / 2 IN. 0.5 × LL
MAXIMUM

CURTAIN WALLS / VERTICAL L / 600 ≤ 3 / 8 IN. DL INCL.


SPANDRELS DEFLECTION MAXIMUM CLADDING WEIGHT

40 / DESIGN GUIDE 3, 2ND EDITION / SERVICEABILITY DESIGN CONSIDERATIONS FOR STEEL BUILDINGS
SERVICEABILITY CONSIDERATIONS

CEILINGS AND PARTITIONS

FINISH STRUCTURAL RECOMMEN-


DEFORMATION LOADING
TYPE ELEMENT DATION

PLASTERED
ROOF MEMBER
VERTICAL L / 360 0.5 × LL OR
CEILING DEFLECTION MAXIMUM 50 YEAR SNOW

ROOF MEMBER
VERTICAL L / 240 0.5 × LL OR
DEFLECTION MAXIMUM 50 YEAR SNOW
NON-PLASTERED
CEILING
FLOOR BEAM / VERTICAL L / 360 ≤ 1 IN.
DL
GIRDER DEFLECTION MAXIMUM

HORIZONTAL H / 500
FRAME 10 YEAR WIND
MOVEMENT MAXIMUM

PARTITION ROOF MEMBER


VERTICAL 3 / 8 IN. TO 1 IN. 0.5 × LL OR
DEFLECTION MAXIMUM 50 YEAR SNOW

FLOOR BEAM / VERTICAL L / 360 ≤ 3 / 8 IN. TO


GIRDER DEFLECTION 1 IN., MAXIMUM 0.5 × LL

DESIGN GUIDE 3, 2ND EDITION / SERVICEABILITY DESIGN CONSIDERATIONS FOR STEEL BUILDINGS / 41
SERVICEABILITY CONSIDERATIONS

EQUIPMENT

EQUIPMENT STRUCTURAL RECOMMEN-


DEFORMATION LOADING
TYPE ELEMENT DATION

RUNWAY TOTAL INWARD 1 /2 IN. LL OR


SUPPORTS MOVEMENT MAXIMUM 50 YEAR SNOW

RUNWAY TOAL OUTWARD 1 IN.


SNOW
SUPPORTS MOVEMENT MAXIMUM
TOP RUNNING
CRANES HORIZONTAL L / 400
RUNWAY BEAM CRANE LATERAL
DEFECTION MAXIMUM

RUNWAY BEAM VERTICAL L / 600 CRANE LATERAL


CMAA ‘A’, ‘B’ & ‘C’ DEFLECTION MAXIMUM STATIC LOAD

RUNWAY BEAM VERTICAL L / 800 CRANE LATERAL


CMAA ‘D’ DEFLECTION MAXIMUM STATIC LOAD

RUNWAY BEAM VERTICAL L / 1000 CRANE LATERAL


CMAA ‘E’ & ‘F’ DEFLECTION MAXIMUM STATIC LOAD

TOP RUNNING DRIFT AT RUNWAY H / 100 ≤ 1-IN. CRANE LATERAL


BARE FRAME
CAB OPERATED ELEVATION MAXIMUM OR 10 YR. WIND

TOP RUNNING
DRIFT AT RUNWAY H / 240 ≤ 1-IN. CRANE LATERAL
PENDANT BARE FRAME
ELEVATION MAXIMUM OR 10 YR. WIND
OPERATED

UNDERHUNG RUNWAY BEAM VERTICAL L / 450


CRANE VERTICAL
CRANE CMAA ‘A’, ‘B’ & ‘C’ DEFLECTION MAXIMUM

VERTICAL H / 225
JIB CRANE BOOM CRANE VERTICAL
DEFLECTION MAXIMUM

H / 500
BARE FRAME DRIFT 10 YEAR WIND
MAXIMUM

ELEVATORS
MACHINE / VERTICAL L / 1666
DL + LL
SHEAVE BEAMS DEFLECTION MAXIMUM

MACHINE /
VERTICAL H / 1666
SHEAVE BEAMS DL + LL
DEFLECTION MAXIMUM
SUPPORTS

42 / DESIGN GUIDE 3, 2ND EDITION / SERVICEABILITY DESIGN CONSIDERATIONS FOR STEEL BUILDINGS