0% found this document useful (0 votes)
148 views

Slab Design Strip Method v1.0

This document summarizes the design checks for a reinforced concrete element. It includes calculations for shear capacity, service moment capacity, ultimate moment capacity, and temperature and shrinkage reinforcement checks. All capacity checks show the element is adequate, with utilization percentages below 80% for shear, service moment, ultimate moment, and temperature/shrinkage reinforcement. Material properties, section dimensions, and reinforcement details are provided.

Uploaded by

Kyra Aleson
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
148 views

Slab Design Strip Method v1.0

This document summarizes the design checks for a reinforced concrete element. It includes calculations for shear capacity, service moment capacity, ultimate moment capacity, and temperature and shrinkage reinforcement checks. All capacity checks show the element is adequate, with utilization percentages below 80% for shear, service moment, ultimate moment, and temperature/shrinkage reinforcement. Material properties, section dimensions, and reinforcement details are provided.

Uploaded by

Kyra Aleson
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

Engineer

Project Title
Checker
Location
Sheet Number
Element Type
Element Mark
Reference
Client

Material Strength Material Elasticity


Concrete Strength, f'c = 21.00 MPa Modulus of Elasticity of Concrete, Ec = 21538.11
Steel Yield Stress, fy = 275.00 MPa Modulus of Elasticity of Steel, Es = 200000.00

Section Properties Reinforcing Bars


Thickness, h = 200 mm Bar Diameter, db = 12
cover, c = 40 mm Bar Spacing, s = 100
Effective Depth = 154 mm Area of Reinforcement per 1m = 1130.97

Shear Check Reference: ACI 318M-08 Chapter 11

Shear Capacity of Section, Vc = ∅ 0.17√(𝑓^′ 𝑐) 𝑏 � = 89.98 kN Note: ø for shear = 0.75

Ultimate Shear Force, Vu = 50.00 kN Section Adequate for Shear!

Serviceability Check Reference: ACI 224R-01 and ACI 318M-08 Section 10.
Cracked Section Dimensions
Permissible Crack width = 0.30 mm Depth of Compressive block, x = 47.33
Beta ratio, β = 1.43 Cracked Moment of Intertia, Ic = 154839440.89
modular ratio = 9.29 Concrete Area symm. w/ rebar, A = 920000

crack width, w = 0.011023 𝛽 𝑓𝑠 ∛�𝑐𝐴 10−3 permissible fs (due to crack width limit) = 57.17

Service Moment Capacity = 8.94 kN-m

Service Moment, Ms = 5.00 kN-m Section Adequate for Service Moment!

Ultimate Flexure Check Reference: ACI 318M-08 Chapter 10

Depth of Compression Block Factor, β1 = 0.85

Balanced Steel Ratio, ρb


0.85 𝛽1 𝑓′𝑐/𝑓𝑦 600/(600+𝑓𝑦) Actual Steel Ratio, ρactual 𝐴𝑠/(𝑏 �) =
= = 0.0378 =

Steel Yields! Section is Ductile!

Resultant Tension, T = 𝐴𝑠 𝑓𝑦 = 311017.67 N

By ΣF Horizontal:

Compressive Block Resultant, C = 0.85 𝑓^′ 𝑐 𝛽1 𝑐 (1000) = 311017.67 N Depth of Neutral Axis, c =
Depth of Compressive Block, a =
By ΣMoment about Tension Steel:

Ultimate Moment Capacity, Mucap = 40.67 kN-m

Ultimate Moment, Mu = 30 kN-m Section Adequate for Ultimate Moment!

Temperature and Shrinkage Reinforcement Check Reference: ACI 318M-08 Section 7.12.2

Face of Slab Exposure: Face not exposed to Soil Reinforcement Grade: Grade 280 or 530
Minimum Temperature and Shrinkage Reinforcement: = 0.002 b t = 400.00

Reinf. Adequate for Temp. and Shrinkage Requirem

Percentage of Utilization Summary

Shear 35
Servi ce Moment 74
Ul timate Moment
56
Temp. and
Shri nkage 56

0 10 20 30 40 50 60 70 80
21538.11 Mpa
200000.00 MPa

12 mm
100 mm
1130.97 mm2

0.75

Section Adequate for Shear!

ACI 224R-01 and ACI 318M-08 Section 10.6.4

47.33 mm
154839440.89 mm4
920000 mm2

57.17 Mpa

Section Adequate for Service Moment!

0.0073

Steel Yields! Section is Ductile!

20.50 mm
17.42 mm

Section Adequate for Ultimate Moment!


mm2

Reinf. Adequate for Temp. and Shrinkage Requirement!

35
74
56
56

0 30 40 50 60 70 80

You might also like