Hydrometer No. Average Temperature (°C) R R' - C +C

This document contains data from a hydrometer test. It includes hydrometer readings taken over time at different temperatures to determine particle size distribution and percent finer. Calculations are shown to convert hydrometer readings into effective size using Stokes' law and the percent of particles finer than various sizes based on the original soil weight. The results indicate that after 1440 minutes, 1.1% of particles were finer than 0.0111 mm in size.

Uploaded by

Rafiq Mir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
82 views

Hydrometer No. Average Temperature (°C) R R' - C +C

This document contains data from a hydrometer test. It includes hydrometer readings taken over time at different temperatures to determine particle size distribution and percent finer. Calculations are shown to convert hydrometer readings into effective size using Stokes' law and the percent of particles finer than various sizes based on the original soil weight. The results indicate that after 1440 minutes, 1.1% of particles were finer than 0.0111 mm in size.

Uploaded by

Rafiq Mir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 3

Hydrometer No.

Average 23.45
Temperature (°C)

R=R'h-Cd+Ct

Hydrometer Reading R'h=Rh+Cm


Temperature Elapsed Time
(°C) T(min) Cd always negative; Ct
from handout: Ct take
-ve when temp<27 ;
(in terms of divisions) not in Cm not in terms of Sp Ct=+ve when temp>27
terms of Sp Gr Gr

24 0.5 26 27 26.7
24 1 24 25 24.7
24 2 15 16 15.7
24 5 13 14 13.7
24 10 11 12 11.7
24 15 9.1 10.1 9.8
23.8 30 8.7 9.7 9.4
23.7 60 7.2 8.2 7.9
24 120 5.4 6.4 6.1
24.9 240 2.4 3.4 3.1
16 480 1.5 2.5 2.2
25 1440 1.1 2.1 1.8
Cm 1 Gs 2.49 Ws (g) 50
Ct -0.3 W (g) 1000
Cd 0 Wp (g) 968.00

Particle Size
Percent finer N' %
D=K*(L/T)0.5
L effective depth K
(cm)
Hydrometer reading in L/T N' = (��*𝑅*100)/
terms of Gs (cm/min) (L/T)0.5
((��-1)∗��)
D in mm
(from te K= (0.3n/g(G- wrt 50g soil
calibration chart) 1)Yw)
R from col F

1.026 11.9300 0.00138 23.8600 4.8836 0.0674 89.18


1.024 12.2600 0.00138 12.2600 3.5014 0.0483 82.50
1.015 13.7300 0.00138 6.8650 2.6201 0.0362 52.44
1.013 14.0600 0.00138 2.8120 1.6769 0.0231 45.76
1.011 14.3600 0.00138 1.4360 1.1983 0.0165 39.08
1.0091 14.7200 0.00138 0.9812 0.9906 0.0137 32.73
1.0087 14.7900 0.00138 0.4930 0.7021 0.0097 31.40
1.0072 15.0200 0.00138 0.2503 0.5000 0.0069 26.39
1.0054 15.2900 0.00138 0.1274 0.3569 0.0049 20.37
1.0024 15.7800 0.00138 0.0657 0.2563 0.0035 10.35
1.0015 15.9600 0.00138 0.0333 0.1825 0.0025 7.35
1.0011 16.0200 0.00138 0.0111 0.1054 0.0015 6.01
% finer on the total wt
W (N)

N = (� ∗𝑁′)/�

86.33
79.87
50.76
44.30
37.83
31.68
30.40
25.55
19.72
10.02
7.11
5.82

You might also like