User Manual
Read and save these instructions before use
Email: [email protected]
Web: www.jmatek.com
Model :
MN09 Series: MN09CES, MN09CESBB, MN09CESWW, MN09CHES, MN09CHESBB, MN09CHESWW
MN10 Series: MN10CES, MN10CESBB, MN10CESWW, MN10CHES, MN10CHESBB, MN10CHESWW
MN12 Series: MN12CES, MN12CESBB, MN12CESWW, MN12CHES, MN12CHESBB, MN12CHESWW
MN13 Series: MN13CES, MN13CESBB, MN13CESWW, MN13CHES, MN13CHESBB, MN13CHESWW
THANK YOU
USER TIPS
Honeywell Portable Air Conditioners are ideal for spot cooling. The compressor, condenser and
evaporator are housed in a compact unit. The air is filtered, dehumidified and cooled while a flexible air
outlet hose sends heat outside. The air conditioner includes a window venting kit.
No permanent installation is needed. The unit is easy to move from room to room and offers a truly
flexible air conditioning solution.
Auto Evaporation System - The unit automatically evaporates the condensate through the air
outlet hose. There is no need to empty the drainage tank except in very high humidity conditions.
Read and follow the instructions carefully.
USER TIPS
To ensure optimal efficiency of the product, keep doors and windows closed when it is used as an air
conditioner or dehumidifier. If the product is being used with the fan function only, an open window could
improve air circulation.
Important:
Before installing the unit, place it UPRIGHT for 20 minutes before use to allow the refrigerant to
stabilize.
Manually adjust the air vent located at the top of the unit to adjust the direction of air flow.
1
EN
SAFETY
WARNING:
• DO NOT operate the unit with a damaged plug or loose wall outlet. If the power cord is damaged, it
must be replaced by the manufacturer or an authorized service agent.
• DO NOT cover the air intake and exhaust when in use.
• This appliance is not intended for use by children. Children should be supervised and should not play
on or around the appliance.
• DO NOT place objects on or sit on the unit.
• Always turn off and unplug the unit when cleaning or servicing.
• If service is needed contact an authorized service agent.
• Unplug the unit when stored or not in use.
• DO NOT run the power cord under carpeting and rugs.
• Use caution to prevent tripping on cord.
• DO NOT use in areas where gasoline, paint or other flammable goods are stored.
• Basic safety precautions should always be followed when using electrical appliances.
• This appliance has been manufactured for use in domestic environments and should not be used for
other purposes.
PARTS DESCRIPTION
(5)
(6)
(2)
(1)
(3)
(11)
(7)
(9)
(10)
(4) (8)
2
EN
INSTALLATION
Installation Kit: 1 2 3
1. Window Bracket Kit............................. 1 Set x1 x1
2. Window Bracket Panel Adapter........... 1 Piece
3. Hose Connector.................................. 1 Piece
4 x1
4. Plastic Hose........................................ 1 Piece
Installation Steps: x1
1. Install the plastic hose with window bracket adapter and hose connector on both sides. Ensure
proper fit on both ends.
2. The Window Brackets are approximatley 72 cm / 28.3 inches each, allowing you to install to
windows and balcony doors of different heights or width.
2 m / 78.7”
3 parts To install the window bracket to the
window frame, you need to adjust the
72 cm / 28.3” to height or width of the window bracket by
135 cm / 53.1”
2 parts extending the length according to the
height or width of the window or balcony
28.3” door. When the length is set, tighten the
72 cm
1 part butterfly screws (preinstalled on the
window bracket) to ensure the window
bracket is secured in the desired position.
Use one or all three pieces of window
bracket as needed.
Butterfly Screws
3. Connect the plastic hose to the rear exhaust 5. Connect the window bracket to the window.
outlet on the back of the unit. Push-in until it is
locked in place.
4. Connect the window bracket to the opposite 6. The Portable Air Conditioner is now ready to
end of the plastic hose. Ensure that all use.
connections are tight and installed properly.
3
EN
INSTALLATION
Installation Kit: 1 2 3 4
1. Window Bracket Kit............................. 1 Set
2. Window Bracket Panel Adapter........... 1 Piece
3. Plastic Pin............................................ 2 Pieces x1 x2 x1
4. Hose Connector.................................. 1 Piece
5. Plastic Hose........................................ 1 Piece 5
x1 x1
Installation Steps:
1. Install the plastic hose with window bracket adapter and hose connector on both sides.
Ensure proper fit on both ends.
2. Adjust the window bracket as per width or height of your window and insert the plastic pins to fix at
the desired position. There is a hole where the Plastic Hose will be inserted later. Make sure this hole
is not blocked.
3. Connect the plastic hose to the hose 5. Connect the window bracket to the window.
connector on back of the unit. Push-in until it
is locked in place.
4. Connect the window bracket to the opposite 6. The Portable Air Conditioner is now ready to
end of the plastic hose. Ensure that all use.
connections are tight and installed properly.
3
EN
INSTALLATION
Installation kit: 1 2 3
1. Flange Fixture...................................... 1 Piece
2. Hose Connector.................................. 2 Pieces x1 x2 x1
3. Hole Cover.......................................... 1 Piece
4. Plastic Hose........................................ 1 Piece
5. Exhaust Nozzle.................................... 1 Piece 4 5
x1 x1
Through an Open Window
1. Install the plastic hose with exhaust nozzle and hose connector on both sides. Ensure proper fit on
both ends.
2. Connect the plastic hose to the rear exhaust 3. Extend the plastic hose through an open
outlet on the back of the unit. Push-in until it is window and close the window as far as possible
locked in place. trapping the Exhaust Nozzle (as shown below).
MIN. 36 cm / 14”
3
EN
INSTALLATION (CONTINUED)
NOTE:
1. The supplied exhaust hose can be extended from 30 cm to 120 cm / 12 inches to 47 inches.
2. Do not bend (to the extent shown below) the exhaust hose. A bent hose will block exhaust air and
cause the unit to malfunction or shut-off.
50 cm / 20”
MIN. 36 cm / 14”
NOT RECOMMENDED RECOMMENDED
• The length of the exhaust hose is determined by the product specifications. Do not replace or
lengthen it as this could cause the unit to malfunction.
• Make sure the back of the unit is at least 50 cm / 20 inches away from. Do not place the unit in front
of curtains or drapes as this could obstruct the airflow.
(1) Timer Control (2) Fan Speed Control (3) Timer / Temperature Set Controls
(4) Mode Control (5) Power Control (6) Warning Light (when flashing)
POWER CONTROL
The Power Control turns the unit on and off.
MODE CONTROL
3
4 settings: Cool, Dehumidify, Fan.
Heater*, Dehumidify & Fan.
A light will indicate which setting is currently being used.
• Cooling Mode
The unit works as an air conditioner. Adjust fan speed and air temperature to suit your desired comfort
level. Temperature setting range is 16°C- 32°C (61°F- 89°F).
• Heating Mode*
When heating mode is selected the indicator light will shine. Heating is activated only when the ambient
temperature is below 25°C (77°F). In this mode, the desired temperature can be set between 16°C- 25°C
(61°F- 77°F). Note: The air exchange hoses must vent outside the room when using heating mode.
4
EN
USE & OPERATION (CONTINUED)
• Dehumidifying Mode
Air is dehumidified as it passes through the unit, without being in full cooling mode. If room tempera-
ture is higher than 25°C (77°F) fan speed can be adjusted; otherwise fan speed is preset to LOW.
Note: If the unit will be used mainly as a dehumidifier, do not connect the exhaust hose and let the
warm air return in the room. Continuous drainage is then necessary and more efficient (refer to
Continuous Draining).
• Fan Mode
For air circulation without air conditioner cooling.
TIMER CONTROL
While the unit is turned on, press the timer button then press the ▼ or ▲ to select the number of hours
you would like the unit to continue to run. The unit will turn off automatically.
AUTO TURN OFF:
While unit is running, press the press the ▼ or ▲ button to select the number of hours you want the unit
to run in air conditioning mode.
AUTO TURN ON:
When unit is in a standby mode (plugged in with power light on), then press the ▼ or ▲ button to select
the number of hours until you want the unit to automatically start running.
WARNING LIGHT
Condensed water may accumulate in the unit. If the internal tank becomes full, the Power Control light
will flash and the unit will not operate until the unit has been drained (refer Water Condensation
Drainage).
After switching the air conditioner off, you must wait 3 minutes before switching it back on
again.
5
EN
USE & OPERATION (CONTINUED)
REMOTE CONTROL
The functions work the same as the portable air conditioner's Touch Screen Control Panel.
All key functions can be accessed from the remote control.
Power Control
ON / OFF Temperature / Timer Set
Note:
• Battery Installation: Remove the cover on the back of the remote control and insert two AAA batteries
with + and - pointing in the proper direction according to the polarity markings.
Caution:
• Use only two AAA or IEC R03 1.5V batteries.
• Remove the batteries if the remote control is not in use for a month or longer.
• All batteries should be replaced at the same time, do not mix with old batteries.
• Properly dispose of used batteries.
6
EN
CLEANING & MAINTENANCE
Appliance Maintenance:
1. Turn off the appliance before disconnecting the power supply.
2. Always clean the appliance with a soft dry cloth.
Air Filter Maintenance:
The air filter should be cleaned every two weeks. Clean it as follows:
1. Turn off the appliance and remove the air filter .
2. Rinse it in lukewarm water. After cleaning, dry in a shaded and
cool place, then reinstall.
1. Be sure to drain the left-over water condensation. Remove the lower drain plug and use a
shallow pan to collect the water (make sure to replace the drain plug when finished).
2. To dry excess moisture, run the unit in Fan only mode for 30 minutes before storing.
3. Turn off and unplug the air conditioner from the power supply.
4. Remove the air filter and clean with water. Dry the air filter and then reinstall onto the unit.
5. Disconnecting the Window Installation Kit:
• Remove the Plastic Hose from the unit by pulling away from the unit at the same time.
• Remove the Window Bracket, Window Bracket Panel Adapter and Hose Connector.
• It is recommended to store the Window Kit parts in a bag together with the Remote Control and
placing them together with the air conditioner unit.
• If needed, you can clean the Window Kit with a damp cloth and water before storing. Make sure all
parts of the Window Kit are dry before storage.
6. Cover the air conditioner with a cloth/ plastic bag before storage, to protect from dust and scratches
collecting on the surface of the unit.
7. It is recommended to coil the power cord and store it away from the floor to ensure the cord is
protected from bents and creases.
7
EN
WATER CONDENSATION DRAINAGE
WATER CONDENSATION DRAINAGE
When there is excess water condensation inside the unit, the air conditioner stops running and
shows a warning light. This warning light indicates that the water condensation needs to be drained
using the following procedures:
Manual Draining for AC & Dehumidifier Mode
Water may need to be drained in high humidity areas.
1. Unplug the unit from power source.
2. Place a shallow pan under the lower drain plug.
See diagram.
Lower
3. Remove the lower drain plug. Drain Plug
4. Water will drain out and collect in the shallow pan.
5. After the water is drained, replace the lower drain Shallow Pan
plug firmly. (Not included)
8
EN
TROUBLESHOOTING GUIDE
The following troubleshooting guide addresses the most common problems. If problems persist, call
customer service. Unplug and disconnect the appliance from the power source before attempting to
troubleshoot.
Will not run and • Excess water condensation inside • Drain the water (refer to Water
water full indicator the tank. Condensation Drainage).
light is ON
Heater is not • Heating function not activated yet. • Check that the Heating function
switching ON The ambient temperature is too high. has been activated. will be
(This may only be illuminated when the Heater is
applicable for switched ON.
Portable Air • Heating is activated only when the • Switch on the Heating function
Conditioner models ambient temperature is below 25°C when the ambient temperature
with built-in Heating (77°F). reaches below 25°C (77°F).
function only).
9
EN
JMATEK North America LLC © 2015 JMATEK Limited. All rights reserved.
Mahwah, New Jersey 07495 USA The Honeywell Trademark is used under license from
Honeywell International Inc.
Phone: 1-800-474-2147 Honeywell International Inc. makes no representations
Email: [email protected] or warranties with respect to these products.