Digital Energy
Digital Energy
Introduction:
Advanced protection, control and
communications Protection, Control, Metering, Monitoring,
Analysis and Energy Management System
• Supports open communications
protocols such as ModBus/DNP for
integration with other IEDs
• Applicable for electrical utilities as
well as industrial electrical systems
• Best value for price
• Building block for systems
• Large graphical built-in interface
• Meets well established IEC 61131-
3 standard for easy logic
configuration
• Graphical editor for programming
logic
• Pre-assigned interlocking 2/
GE /
June 19, 2015
Applications
Advanced Protection for Industrial and Distribution
Utilities The F650 can be used for:
• Comprehensive feeder protection
and control functionality at any
voltage level
• Backup protection for transformers,
busbars, generators and large
motors
• Control functions include
synchronism-check, recloser and
breaker failure
• Monitoring functions:
Oscillography
Event Recorder
Fault Recorder
Data Logger 3/
GE /
June 19, 2015
Features & Benefits
Supporting design flexibility with multiple I/O
options
The F650 features advantage
such as:
• Modular hardware architecture:
Main CPU board with two plug and
play comm boards
Universal magnetic (CTs & VTs)
module
Programmable I/O module
Single or redundant power supply
Front board: HMI ( Graphical or
alphanumerical display, LEDs,
RS232)
• Modern and open communication
protocols for easy integration
4/
GE /
June 19, 2015
Block Diagram
Complete Feeder Protection and Control of Multiple
Devices
5/
GE /
June 19, 2015
Protection
Complete Feeder Protection and Control of Multiple
Devices
• Phase, neutral and ground • Under and overvoltage elements
TOCs and IOCs
• Under and overfrequency elements
• Standard curves and
programmable user curves: • RMS / DFT choice independent from
mains frequency (50 / 60 Hz)
IEEE
• Use of established protection
IEC algorithms
ANSI • Designed to withstand surges,
IAC overcurrents and DC-biased faults
I2t • True universal current range 1/5 A
Definite time • DSP to unload main CPU (64
samples/cycle)
Rectifier
• Bidirectional protection
User curves
• Sensitive earth fault
6/
GE /
June 19, 2015
Control
Control of Multiple Devices including Main Breaker and
Motorized Switches
PC design mode example
F650 Control functions
•include:
Synchrocheck
• 4 Shot autorecloser is fully
programmable
• Breaker failure
• Fuse failure
• One line diagram in graphic LCD display
F650 Actual screen example with capability to display switchgear
elements
• Full control of switches and breakers
• Built in pre-configured interlockings for
secure control.
• Annunciator panel viewing
• Three setting groups available
7/
GE /
June 19, 2015
Monitoring & Metering
Reduce Troubleshooting time and maintenance Cost –
Event Reports, Waveform Capture, IRIG-B Time
Synchronization
The F650 provides:
• Data logger (16 Channels)
• Event recording of up to 479 time-
tagged events
• Programmable oscillography feature
(up to 20 records)
• Monitoring of current, voltage, power,
power factor, energy, demand and
frequency
• Fault recording and location with 10
fault reports
• IRIG-B DC for accurate 1 ms time
tagging
• Breaker monitoring
• Three phase energy metering
8/
GE /
June 19, 2015
Typical Wiring
Multiple configurations suitable for various applications
9/
GE /
June 19, 2015
Mechanical
Various I/O Options, Dual Power Supply Capable, High
Speed Communications
10 /
GE /
June 19, 2015
Hardware
Advanced design – Dual Power Supply, DSP to improve
CPU Performance
Redundant Power Supply CPU+DSP
• Wide input range (HI & LO) • High-speed 32-Bit RISC CPU > 50
LO 24 - 48 VDC MIPS with more than 32 Megabytes
memory
HI 110 - 250 VDC 120 - 230
VAC • Firmware upgrades through the use of
flash memory
• Switching Mode Power Supply with
High Efficiency > 80% • Modular communications for flexibility
and cost effective solutions
• Redundant model available through
the use of 2 modules assembled in • High-speed communications:
the mother board 10/100Mbps Ethernet LAN,
single/redundant Fiber Optic 100Mbps.
11 /
GE /
June 19, 2015
Hardware
Accurate Metering and Expandable I/Os via Internal and
External I/O Modules
Magnetic Module Digital I/O
FRONT PORT
Electrically isolated front USB
communication port
13 /
GE /
June 19, 2015
Hardware
Complete Expandability based on modular design
Standard I/O
Module Magnetic Module for AC
Optional I/O Current and Voltage Inputs
Module
Standard Power
Supply Async F/O Com1
Rear-View diagram
Distributed I/O displays I/O,
Fiber Optic CAN
Magnetic Module
Redundant Power 10/100BaseT (CTs & VTs), and
Supply (Optional) other connector
100BaseFx locations
Redundant
100BaseFx
Settings Metering
Configuration
15 /
GE /
June 19, 2015
Configuration
Reduce Overall System Costs and Improve System
reliability by Reducing the number of Auxiliary Devices
16 /
GE /
June 19, 2015
Communications
High speed communication capabilities
Block Diagram:
• Internal serial buses to
optimize security and
immunity to EMC.
• High speed buses to avoid
bottlenecks.
• 100 Mbps Ethernet fibre
optic for maximum
performance.
• CAN bus for distributed IO
up to 1 km.
17 /
GE /
June 19, 2015
Communications
Access to Information – Wide Area Network Integration,
Multiple Communication Media and Protocols
Physical layer:
• RS485 asynchronous port up to
115200 bauds.
• Fibre optics asynchronous port
up to 115200 bauds.
• Synchronous Ethernet port up to
100 Mbits/s.
• CAN port for distributed I/O.
• Option for redundant ports (both
synchronous and
asynchronous).
18 /
GE /
June 19, 2015
Communications
Powerful Communications reducing Wiring Costs with
Peer-to-peer Communication
Protocols:
• Modbus RTU and Modbus TCP/IP
• DNP 3.0 Level 2 over TCP/IP, UDP/IP and
serial
• IEC 61850, IEC 60870-5-104 PROTECTION RELAYS
MULTINET
MULTILINK SWITCH
Fiber Optic
DIRECT I/O
BUS CAN
Fiber Optic
C30 CIO CIO CIO HMI
REMOTE DI/DO/AO EXTENSION
19 /
GE /
June 19, 2015
Reliability
Reliable Design Features based on Extensive Industry
Experience
Hardware:
• Redundant power supply
• Distributed supply concept
• “Cool” temperature design through low power consumption
• Replacing hardware by firmware reduces parts count
Firmware:
• Double Flash memory concept avoids program
crashes during field upgrades. This allows secure
remote reprogramming
• CMM model approach for quality
• OOP in high level C language
20 /
GE /
June 19, 2015
F650 Ordering Code
21 /
GE /
June 19, 2015
Dimensions
22 /
GE /
June 19, 2015
CAN Bus Remote I/O Module
Remote CAN Bus Input/Output
Module for the 650 Family
24 /
GE /
June 19, 2015
CIO Ordering Code
25 /
GE /
June 19, 2015
F-650
Feeder Manager and Bay Controller
Advanced Protection for Industrial and Distribution
Utilities
• Integrate protection and
control
> Remote control
> Local control
• Monitor trip/close
circuits, rack in/out
switches
• Applicable for radial and
looped feeders
26 /
GE /
June 19, 2015
F-650 Bay Controller
Standardization & Minimization
• Control Points Eliminate the Need For:
> Trip/Close Switches & Indicators
> Miscellaneous Function Switches
– Metering Display
– Maintenance Lockout
– Transfer, Autotransfer, Block Transfer
• PLC Logic Eliminates the Need For:
> Auxiliary Relays
> Timers
• Dynamic Mimic Eliminates the Need For:
> On-Panel Hard Mimic and Indicators
27 /
GE /
June 19, 2015
Appendix
F650
Product Positioning
28 /
GE /
June 19, 2015
Feeder Protection – F650
Functionality
F60
SR 750/760
F650 F35
MIFII
F650
FMII SR 735/737 Price
“Designed and Built for the Industrial Environment”