Experiment - 10: Performance Test On Flat Plate Solar Water Heater Aim
Experiment - 10: Performance Test On Flat Plate Solar Water Heater Aim
Aim
To study the characteristics of a Flat plate Solar Water Heater and to plot its characteristic
curves.
Apparatus required
Flat plate solar water heating system setup, Digital thermometer and flowmeter and water
pump,
Description
The flat plate solar water heating system works on greenhouse effect, where the
incident solar radiation is trapped inside the gap between the glass cover and absorber
plate. The radiation losses are cut down by using a selective absorber surface. The three
sides of the collector system are insulated where as the top is left open to receive solar
radiation.
Black chrome and black nickel are the most widely used selective surfaces for absorber pipe.
Copper tubes of φ 12 mm and 1900 mm long are mechanically polished and then coated
with nickel layer by electrolysis deposition technique. A storage tank is provided at the top of
the collector to provide cold water. Thermocouples are provided to record the temperature
of glass cover, inlet water, outlet water and absorber plate. A rotameter is provided in the
flow circuit to control the mass flow rate of water flowing in the pipes.
20
Procedure
1. Open the inlet valve to allow cold water into the collector and make sure that the
all the tubes are filled with the water. The collector system should not be run
without water as the pipes will be subjected to thermal stresses.
2. Measure and control the water to a required flow rate using rotameter and the
temperature readings are noted down using the digital thermometer.
3. Take the readings in regular interval of 10 to 15 minutes and plot the
characteristic curves.
Formulae used
Calculations for steady flow condition
mw C p w To Ti
Efficiency,
Is A
mw = mass flow rate of water, kg/sec Is = solar flux, W/m2
Cp = specific heat of water, J/kg.K A = area of absorber plate = (2 x 1) m2
To = water outlet temperature, °C Ta= atmospheric temperature, oC
Ti = water inlet temperature, °C
Graph
1. Time Vs Solar insolation (W/m2)
21
2. Solar insolation Vs Outlet water temperature
3. Performance Curve
Tfi Ta I
s
Vs i
21
Find a and b from the graph (see Fig.3)
Fig.2 Experimental collector efficiency data measured for a liquid heating in Flat plate solar
water heater with one cover and a selective absorber.
Fig.3 Line diagram of solar liquid flat plate collector experimental setup
22
LAB WORK
Observation
24
Model calculation – calculation for Reading no.1
o LPH kg/s
o mV W/m2
o Efficiency:
=0.9978
o From the tabular column and observations we see that the outlet
temperature of water increases with decrease in mass flow rate.
o The efficiency also decreases on decreasing the mass flow rate.
o The temperature difference between the inlet and outlet temperature is
coming around 5-7 deg Celsius.
o Solar radiation was constant throughout the experiment.
25
26