KOCOM Manual KVL Series
KOCOM Manual KVL Series
com
Warranty
SINCE
Cautions
Warnings & Cautions for Safety
Cautions for installation
For safe use, please stick to the following cautions.
■ Read this cautions carefully and keep it within easy reach of you. ● The relevant law obliges users to have a qualified electrician carry out wiring work for power supply.
■ For right installation, read this cautions thoroughly. Please install the product according to its Work by disqualified persons may cause fire and electric shock.
specifications.
● Wiring work for communication cables need techniques and experiences. For this type of wiring work, please consult to
■ This Cautions for Safety may include items that are not contained in specifications of the product that
your local sales agent.
consumer purchases.
● According to the standard for electric work and other relevant regulations, install communication cables at the place away
■ Reading this cautions, use the product in a right manner. For further information,
from power cables. The failure to install cables separately may cause fire, electric shock and communication troubles.
please contact our A/S center.
● Do not install the product on rolling table or sloping place. Dropping or falling may cause damage on your product.
About symbol ● In installation, avoid the place exposed to tremor or shocks, which may cause damages on your product.
A variety of symbols are used in this Cautions for Safety and your products to guide you to use ● Even if your product is waterproof, do not install it slanted place of water leakage, which may cause a short circuit.
products in a right and safe manner and to prevent possible risks for users and other persons and
● For the product of wall-mounting type with fixing pegs, keep it safely.
damages to their property. The meaning of each symbol is as follows. After fully aware of meaning
Fixing pegs may cause injury of user.
of each symbol, read the following cautions.
● Install the product of wall-mounting type carefully not to drop from the wall.
This symbol means that wrong handling or ignorance of matters that this symbol indicates Dropping due to earthquake or tremors may cause injury of user.
may cause serious injury or even death of user. ● When installing the product on the wall, consider the thickness and material of the wall.
Dropping in use may cause injury of user.
This symbol means that wrong handling or ignorance of matters that this symbol indicates
may cause serious injury or property damage of user. Cautions for use
● Do not put heavy thing on the product. Dropping or falling due to heavy things on it may cause injury of user.
This symbol means the matter that user should not do at nay event.
Cautions for repairs and maintenance
This symbol means that user should follow the instructions. ● Clean the dust inside the product regularly. Failure to clean the dust for long time may cause fire.
For inspection and cleaning of the inside of product, please contact your local sales agent.
This symbol means that contents (high voltage, electric shock, warnings, etc.) to which user
● When putting your hands into the inside of equipment, be sure that plug is already detached form an outlet or
should pay attention are included.
circuit-breaker is turned off.
This symbol means that a certain action is not permitted. Specific points not permitted are ● Be careful not to expose the product to benzene, thinner or hot water.
depicted around this symbol (for example, in the left drawing, disassembly is not permitted.). ● Do not expose detergent directly to the product in a way of spraying, etc.
2 3
Warnings Warnings
4 5
Installation Components
Main body Concealed box Adaptor "L" Wrench
Common gate camera Installation
Concealed
box I-Button key (Option) Sun visor (Option)
Main body
Screws
Screw Wrench screw 2EA
Standard height for installation Caution of camera installation 4 pin connector between
Common gate camera common gate camera & household monitor
Center
of Lens 1. White(VIDEO)
500mm
lens 1
2. Red(VOICE) 2
1,675
3
3. Yellow(GND) 4
1,500
500mm
4. Blue(VCC)
1,325
2
3
8 7 8
5 6 6 5 6 5 6
4 4 4 3 4 3 4
2 2 2 1 2 1 2
6
7 8
KVL-TC308i
NO. Name
1 C-Mic
■ EXTENSION UNIT ■ KVL series to KEL series wiring
2 Camera lens
9 3 White LED KEL-312 KEL-T324
4 Speaker 12 House 24 House
KVL series KEL series
10 5 I-Button probe
6 Name indicator-shows house information
11 7 Call button
12 8 House connection terminals
9 Camera angle adjustment by manual
10 Adjust the audio switch
11 Terminal for door opener
12 Power input terminal
13 Power & DATA
14 GND
I-Button Key
13 ※ connect to
extension
unit
14 (KEL series)
8 9
Wiring Information Wiring Connection
A. Adjust audio
Button 5 House
KCV-801R
KCV-W354
Button 3 House
A
KCV-A374
Button 7 House
C D B
: Common gate camera → Monitor audio volume
Button 1 House
Using a screwdriver, increase(+) or decrease(-) the
volume from the Common gate camera to the house
E : Monitor → Common gate camera audio volume
KVM-301
Using a screwdriver, increase(+) or decrease(-) the
volume from the house to the Common gate camera
7
5
3
1
Additional power supply
should be used
GND
N.C
DC+12V/1.5A
C. Terminal for door opener 1 D. Terminal for door opener 2 E. House connection
(Extra adaptor not used) (Extra adaptor is needed) Terminals consist of
Normal opne Normal close 8pin wafer
1. WHITE : VIDEO
Yellow : Yellow : 2. RED : VOICE
Common Common
RED : Black : GND
3. YELLOW : GND
8
6
4
2
POWER 4. BLUE : VCC
DC+12V Black : Brown : 5. WHITE : VIDEO
Button 2 House
300mA DOOR Normal Normal
Button 8 House
open close 6. RED : VOICE
RELEASE
Door Door 7. YELLOW : GND
KCV-802R
DC+12V DC DC
relese relese
300mA 8. BLUE : VCC
KVM-301
adaptor adaptor
Because the common gate camera Door opener 2 is output in N.O / N.C and is
supplies the door opener power, used in connection in compliance with door
12V 300mA, it is not necessary to
1
2
3
4
5
6
7
8
release specification.
install an extra door opener adaptor.
3. YELLOW : GND
7. YELLOW : GND
1. WHITE : VIDEO
5. WHITE : VIDEO
KCV-W354
2. RED : VOICE
6. RED : VOICE
4. BLUE : VCC
8. BLUE : VCC
※ Connection specification of opening/closing device of the above C, D door is not
Button 4 House
operated in individual motion. You have to use by selecting one between two specifications.
Button 6 House
KCV-801R
Common gate camera to monitor 4pin port wiring
upto 50m : CAT5 Cable
upto 80m : TIV 0.6mm(0.3mm²) Cable
upto 100m : TIV 0.8mm(0.5mm²) Cable
upto 150m : TIV 1.0mm(0.8mm²) Cable
10 11
Operation Explanation I-BUTTON Registration and Deletion
■ Communication with house monitor ※ TACT SWITCH Location
1. When the visitor presses the call button for certain house on the common gate camera,
the certain house monitor gets call signal.
2. In case of hanging up the hand-set or pressing talk button, the conversation is available.
3. When finishing talk, put the hand-set onto the HOOK BAR or press talk button once again.
TACT SWICH is necessary to initialize the Common gate camera and to set door opening time.
I-BUTTON Registration and Deletion ※Only when the power is connected to the Terminal ②, TACT SWICH is available.
■ First registration method of I-BUTTON KEY ■ Deletion method 1 of the entire I-BUTTON KEY: Not revealed
1. Call household device connected to the common gate camera. 1. TACT SWITCH of I-BUTTON PBA is pushed 4 times within 2 seconds.
2. Connect call between called household device and common gate camera. 2. During 2 seconds, total deletion buzzer sound is transmitted and total KEY information is deleted to
3. I-BUTTON KEY is contacted on I-BUTTON PROBE for 5 seconds. be changed as the initial status.
4. As it is recognized as unregistered I-BUTTON KEY, error sound occurs 5 times consecutively.
5. For 5 seconds, mode entry status is notified in sound. ■ Deletion method 2 of the entire I-BUTTON KEY: Not revealed
(Input waiting status notification sound is generated for 10 seconds.)
1. Two of registered I-BUTTON KEYs are prepared.
6. Door opening button is pushed on household device under calling.
2. After calling connected household devices, calls are connected.
(It is registered after recognizing household door opening button.)
3. Under calling status, two KEYs are contacted to I-BUTTON PROBE 4 times in turn during 4 seconds.
7. Buzzer sound advising registration of I-BUTTON KEY after the registration is transmitted.
4. For 5 seconds, it is entered into mode entry status and buzzer sound is transmitted.
5. For 10 seconds, input waiting status notification buzzer sound is transmitted and within 10 seconds,
■ Additional registration method of I-BUTTON KEY
door opening button of household device connected to calling is pushed.
1. Registered I-BUTTON KEY is contacted to I-BUTTON PROBE for 5 seconds. 6. For 2 seconds, total deletion notification sound is generated and stored KEY information is deleted.
2. After generation of recognition sound of I-BUTTON KEY, common main entrance door is
opened/closed 1 time for the first time. ■ Set door opening time
3. I-BUTTON KEY to register additionally after maintaining contact for 5 seconds is contacted to
1. Under waiting status, TACT SWITCH within I-BUTTON PBA is pushed for 4 seconds.
I-BUTTON PROBE.
2. Currently set door opening time buzzer sound is generated for 0.5 seconds.
4. When I-BUTTON KEY is registered, registration sound is transmitted.
3. Once internal PCB button is pushed one time, together with buzzer sound, door opening time is
* In case additionally registering I-BUTTON KEY is contacted to I-BUTTON PROBE within 10 seconds
increased per 1 second.
under the status of registration, it is registered additionally and registration sound is transmitted.
* Do-1 second, Re-2 seconds, Mi-3 seconds, Pa-4 seconds (Basic values), Sol-5 seconds,
(When10 seconds elapse, completion sound becomes in a status of waiting after transmission.)
La-6 seconds, Si-7 seconds, Do-8 seconds (Maximum)
12 13
Explanation of I-BUTTON Specification
■ I-BUTTON KEY maximum registration quantity
1. Using EEPROM, maximum up to 1022 are registered.
2. it is impossible to store more than 1022 units and when storage capacity is exceeded, buzzer sound
is transmitted for 4 seconds.
* The same I-BUTTON KEY can store and motion but maintains the existing DATA.
Product Specifications