Structural Analysis
Structural Analysis
PREPARED BY:
STRUCTURAL PERSPECTIVE
SEISMIC LOCATION
DESIGN CRITERIA
A. Minimum Design Loads (NSCP 2015)
i. Dead Load
Ceilings
Electromechanical 0.1 kPa
Ceiling Board 0.13 kPa
Floor Finishes 1.1 kPa
Wall Partition on slab 1.866 kPa
Interior Wall on Beam 9.33 kN/m
Exterior Wall on Beam 12.21 kN/m
Roof Covering
Purlins 0.4 kPa
Roof Sheet 0.1 kPa
B. MATERIAL PROPERTIES
i. Slabs & Foundation
Concrete Compressive Strength, f'c 20.7 MPa 3000 PSI
Main Reinforcement Strength, fy 275 MPa A572-50 G40
Side Bar Reinforcement Strength (Foundations), fy 275 MPa A572-50 G40
Temperature Bar Reinforcement Strength (Slabs), fy 275 MPa A572-50 G40
OTHER VARIABLES
Nv : 1.26
Cv : 0.71
Na : 1.00
Ca : 0.40
Importance Factor (I) : 1.00
COMPUTATION
V = CvIW/RT : 491.49 kN Required Base Shear
Vmax = 2.5CaIW/R : 218.86 kN Maximum Base Shear
Vmin = 0.8ZNvIW/R : 88.35 kN Minimun Base Shear
T = Ct(hn)⁰˙⁷⁵ : 0.3146 sec Time Period (if Less than 0.7 Ft=0)
Ft = 0.07TV : 48.20 kN Required Force @ the top
Ftmax = 0.25V : 54.72 kN Maximum Force @ the top
Therefore:
Ft = 0.00 kN
Vd = 218.86 kN
Weight (kN) Height (m)
1860.31 7.00 m
Factor Used
Seismic Factor : 1.00
Accidental Torsion Moment : 0.05
Natural Torsion Moment : 1.00
DESIGN MOMENTS
Short Span Positive Moment At Midspan
M1 = 1.20 kNm
Area of Reinforcement Required = 130.00 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 300mm Spacing
= 261.80 sq.mm/l.m
Short Span Negative Moment At Continuous Support
M1 = - kNm
Area of Reinforcement Required = - sq.mm/l.m
Reinforcement Provided = -
= - sq.mm/l.m
Short Span Negative Moment At Discontinuous Support
M1 = -1.05 kNm
Area of Reinforcement Required = 130.00 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 300mm Spacing
= 261.80 sq.mm/l.m
Long Span Positive Moment At Midspan
M1 = 1.54 kNm
Area of Reinforcement Required = 150.00 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 300mm Spacing
= 261.80 sq.mm/l.m
Long Span Negative Moment At Continuous Support
M1 = - kNm
Area of Reinforcement Required = - sq.mm/l.m
Reinforcement Provided = -
= - sq.mm/l.m
Long Span Negative Moment At Discontinuous Support
M1 = -1.35 kNm
Area of Reinforcement Required = 150.00 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 300mm Spacing
= 261.80 sq.mm/l.m
Distribution Reinforcement
Area of Reinforcement Required = 200.00 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 375mm Spacing
= 209.44 sq.mm/l.m
DESIGN OF SLAB S2
DESIGN DATA
Slab Name: = S2
Design Code = NSCP 2015
Grade of Concrete = 20.7 Mpa
Grade of Steel Reinforcement = 275 Mpa
Clear Cover = 20 mm
Long Span, Ly = 2.4804 m
Short Span, Lx = 2.05 m
Imposed Load = 3.2 kN/sq.m
Live Load, Qk = 1.9 kN/sq.m
Slab Thickness = 100 mm
Effective Depth Along Ly, Deffx = 75 mm
Effective Depth Along Lx, Deffy = 65 mm
Self Weight = 2.4 kN/sq.m
Total Load, TL (ultimate) = 9.76 kN/sq.m
Span = Two Way Slab
DESIGN MOMENTS
Short Span Positive Moment At Midspan
M1 = 2.93 kNm
Area of Reinforcement Required = 186.29 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 300mm Spacing
= 261.80 sq.mm/l.m
Short Span Negative Moment At Continuous Support
M1 = -4.557 kNm
Area of Reinforcement Required = 293.65 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 200mm Spacing
= 392.70 sq.mm/l.m
Short Span Negative Moment At Discontinuous Support
M1 = -2.56 kNm
Area of Reinforcement Required = 162.52 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 300mm Spacing
= 261.80 sq.mm/l.m
Long Span Positive Moment At Midspan
M1 = 3.28 kNm
Area of Reinforcement Required = 179.90 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 300mm Spacing
= 261.80 sq.mm/l.m
Long Span Negative Moment At Continuous Support
M1 = -5.10 kNm
Area of Reinforcement Required = 282.93 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 200mm Spacing
= 392.70 sq.mm/l.m
Long Span Negative Moment At Discontinuous Support
M1 = -2.87 kNm
Area of Reinforcement Required = 157.03 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 300mm Spacing
= 261.80 sq.mm/l.m
Distribution Reinforcement
Area of Reinforcement Required = 200.00 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 375mm Spacing
= 209.44 sq.mm/l.m
DESIGN OF SLAB S3
DESIGN DATA
Slab Name: = S3
Design Code = NSCP 2015
Grade of Concrete = 20.7 Mpa
Grade of Steel Reinforcement = 275 Mpa
Clear Cover = 20 mm
Long Span, Ly = 4.6 m
Short Span, Lx = 2.2264 m
Imposed Load = 3.2 kN/sq.m
Live Load, Qk = 1.9 kN/sq.m
Slab Thickness = 100 mm
Effective Depth Along Ly, Deffx = 65 mm
Effective Depth Along Lx, Deffy = 75 mm
Self Weight = 2.4 kN/sq.m
Total Load, TL (ultimate) = 9.76 kN/sq.m
Span = One Way Slab
DESIGN MOMENTS
Short Span Positive Moment At Midspan
M1 = 3.46 kNm
Area of Reinforcement Required = 189.92 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 300mm Spacing
= 261.80 sq.mm/l.m
Short Span Negative Moment At Continuous Support
M1 = -5.375 kNm
Area of Reinforcement Required = 298.89 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 200mm Spacing
= 392.70 sq.mm/l.m
Short Span Negative Moment At Discontinuous Support
M1 = -3.02 kNm
Area of Reinforcement Required = 165.75 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 300mm Spacing
= 261.80 sq.mm/l.m
Long Span Positive Moment At Midspan
M1 = - kNm
Area of Reinforcement Required = - sq.mm/l.m
Reinforcement Provided = -
= - sq.mm/l.m
Long Span Negative Moment At Continuous Support
M1 = - kNm
Area of Reinforcement Required = - sq.mm/l.m
Reinforcement Provided = -
= - sq.mm/l.m
Long Span Negative Moment At Discontinuous Support
M1 = - kNm
Area of Reinforcement Required = - sq.mm/l.m
Reinforcement Provided = -
= - sq.mm/l.m
Distribution Reinforcement
Area of Reinforcement Required = 200.00 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 375mm Spacing
= 209.44 sq.mm/l.m
DESIGN OF SLAB S4
DESIGN DATA
Slab Name: = S4
Design Code = NSCP 2015
Grade of Concrete = 20.7 Mpa
Grade of Steel Reinforcement = 275 Mpa
Clear Cover = 20 mm
Long Span, Ly = 4.6 m
Short Span, Lx = 1.5 m
Imposed Load = 3.2 kN/sq.m
Live Load, Qk = 1.9 kN/sq.m
Slab Thickness = 100 mm
Effective Depth Along Ly, Deffx = 65 mm
Effective Depth Along Lx, Deffy = 75 mm
Self Weight = 2.4 kN/sq.m
Total Load, TL (ultimate) = 9.76 kN/sq.m
Span = One Way Slab
DESIGN MOMENTS
Short Span Positive Moment At Midspan
M1 = 1.37 kNm
Area of Reinforcement Required = 150.00 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 300mm Spacing
= 261.80 sq.mm/l.m
Short Span Negative Moment At Continuous Support
M1 = -2.440 kNm
Area of Reinforcement Required = 150.00 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 300mm Spacing
= 261.80 sq.mm/l.m
Short Span Negative Moment At Discontinuous Support
M1 = - kNm
Area of Reinforcement Required = - sq.mm/l.m
Reinforcement Provided = -
= - sq.mm/l.m
Long Span Positive Moment At Midspan
M1 = - kNm
Area of Reinforcement Required = - sq.mm/l.m
Reinforcement Provided = -
= - sq.mm/l.m
Long Span Negative Moment At Continuous Support
M1 = - kNm
Area of Reinforcement Required = - sq.mm/l.m
Reinforcement Provided = -
= - sq.mm/l.m
Long Span Negative Moment At Discontinuous Support
M1 = - kNm
Area of Reinforcement Required = - sq.mm/l.m
Reinforcement Provided = -
= - sq.mm/l.m
Distribution Reinforcement
Area of Reinforcement Required = 200.00 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 375mm Spacing
= 209.44 sq.mm/l.m
DESIGN OF SLAB S5
DESIGN DATA
Slab Name: = S5
Design Code = NSCP 2015
Grade of Concrete = 20.7 Mpa
Grade of Steel Reinforcement = 275 Mpa
Clear Cover = 20 mm
Long Span, Ly = 2.9 m
Short Span, Lx = 2.4 m
Imposed Load = 3.2 kN/sq.m
Live Load, Qk = 1.9 kN/sq.m
Slab Thickness = 100 mm
Effective Depth Along Ly, Deffx = 75 mm
Effective Depth Along Lx, Deffy = 65 mm
Self Weight = 2.4 kN/sq.m
Total Load, TL (ultimate) = 9.76 kN/sq.m
Span = Two Way Slab
DESIGN MOMENTS
Short Span Positive Moment At Midspan
M1 = 3.51 kNm
Area of Reinforcement Required = 224.46 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 300mm Spacing
= 261.80 sq.mm/l.m
Short Span Negative Moment At Continuous Support
M1 = -6.246 kNm
Area of Reinforcement Required = 408.32 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 150mm Spacing
= 523.60 sq.mm/l.m
Short Span Negative Moment At Discontinuous Support
M1 = - kNm
Area of Reinforcement Required = - sq.mm/l.m
Reinforcement Provided = -
= - sq.mm/l.m
Long Span Positive Moment At Midspan
M1 = 4.49 kNm
Area of Reinforcement Required = 248.18 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 300mm Spacing
= 261.80 sq.mm/l.m
Long Span Negative Moment At Continuous Support
M1 = -6.98 kNm
Area of Reinforcement Required = 392.09 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 200mm Spacing
= 392.70 sq.mm/l.m
Long Span Negative Moment At Discontinuous Support
M1 = -3.93 kNm
Area of Reinforcement Required = 216.42 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 300mm Spacing
= 261.80 sq.mm/l.m
Distribution Reinforcement
Area of Reinforcement Required = 200.00 sq.mm/l.m
Reinforcement Provided = 10mmØ @ 375mm Spacing
= 209.44 sq.mm/l.m
BEAM DESIGN OF 2B-2
DESIGN DATA
Concrete
Base b = 200 mm
Height h = 400 mm
Concrete Cover Cc = 40 mm
Main Bar Diameter d - main = 16 mm
Shear Reinforcements
Bar Diameter d - sec = 10 mm
• • • • • • • •
Compression Area
Tension Area
Tension Area
0 0 0
0 0 0
0 0 0
Effective Depth, d
Effective Depth, d
0 0 0
0 0 0
Effective Depth, d
0 0 0
Height, h
Height, h
Height, h
Compression Area
Compression Area
Tension Area
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
• 0 0 0 0 0 0 0
• • 0 0 0
•
1 0 0 0
• • 0 0 0 0 0 0 0
•
Shear Reinforcements
Bar Diameter d - sec = 10 mm
Bar Spacing
1st Spacing S-1 = 1@ 50 mm
2nd Spacing S-2 = 2@ 100 mm
3rd Spacing S-3 = 2@ 150 mm
4th Spacing S-4 = mm
5th Spacing S - rest = Rest @ 300 mm
For Midspan
Area of Steel
At Tension As = 603.19 mm²
At Compression As' = 402.12 mm²
Effective Depth
At Tension d = 342.00 mm
At Compression d' = 58.00 mm
Compression Block Depth a = 70.96 mm
Steel Stresses
At Tension fs = 1857.90 Mpa
At Compression fs' = 183.16 Mpa
Computed Reduction Factor φf = 0.90
Moments
Ultimate Moment Capacity φMn = 87.72 kN-m
Factored Moment Mu = 21.37 kN-m
Demand-Capacity Ratio DC Ratio = 0.24 SAFE
For Midspan
Area of Steel
At Tension As = 402.12 mm²
At Compression As' = 603.19 mm²
Effective Depth
At Tension d = 342.00 mm
At Compression d' = 58.00 mm
Compression Block Depth a = 47.31 mm
Steel Stresses
At Tension fs = 3086.85 Mpa
At Compression fs' = 0.00 Mpa
Computed Reduction Factor φf = 0.90
Moments
Ultimate Moment Capacity φMn = 47.70 kN-m
Factored Moment Mu = -20.69 kN-m
Demand-Capacity Ratio DC Ratio = 0.43 SAFE
• • • • • •
Compression Area
Tension Area
Tension Area
0 0 0
1
0
• • 0
0
1
0
• •
Effective Depth, d
Effective Depth, d
0 0 0
0 0 0
Effective Depth, d
0 0 0
Height, h
Height, h
Height, h
Compression Area
Compression Area
Tension Area
0 0 0
0 0 0
0 0 0
0 0 0
0
0
1
0
• • 0
0
• 0 0 0 0 0 0 0
• • 0 0 0 0 0 0 0
• • 0 0 0 0 0 0 0
•
Shear Reinforcements
Bar Diameter d - sec = 10 mm
Bar Spacing
1st Spacing S-1 = 1@ 50 mm
2nd Spacing S-2 = 2@ 100 mm
3rd Spacing S-3 = 2@ 150 mm
4th Spacing S-4 = mm
5th Spacing S - rest = Rest @ 300 mm
For Midspan
Area of Steel
At Tension As = 804.25 mm²
At Compression As' = 402.12 mm²
Effective Depth
At Tension d = 321.50 mm
At Compression d' = 58.00 mm
Compression Block Depth a = 94.62 mm
Steel Stresses
At Tension fs = 1132.93 Mpa
At Compression fs' = 287.37 Mpa
Computed Reduction Factor φf = 0.90
Moments
Ultimate Moment Capacity φMn = 109.57 kN-m
Factored Moment Mu = 48.66 kN-m
Demand-Capacity Ratio DC Ratio = 0.44 SAFE
For Midspan
Area of Steel
At Tension As = 402.12 mm²
At Compression As' = 804.25 mm²
Effective Depth
At Tension d = 342.00 mm
At Compression d' = 78.50 mm
Compression Block Depth a = 47.31 mm
Steel Stresses
At Tension fs = 3086.85 Mpa
At Compression fs' = 0.00 Mpa
Computed Reduction Factor φf = 0.90
Moments
Ultimate Moment Capacity φMn = 47.70 kN-m
Factored Moment Mu = -2.19 kN-m
Demand-Capacity Ratio DC Ratio = 0.05 SAFE
• • • • • • • •
Compression Area
Tension Area
Tension Area
0 0 0
1
0
• • 0
0
1
0
• •
Effective Depth, d
Effective Depth, d
0 0 0
0 0 0
Effective Depth, d
0 0 0
Height, h
Height, h
Height, h
Compression Area
Compression Area
Tension Area
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
• 0 0 0
•
1 0 0 0
• • 0 0 0
•
1 0 0 0
• • 0 0 0
•
1 0 0 0
•
Shear Reinforcements
Bar Diameter d - sec = 10 mm
Bar Spacing
1st Spacing S-1 = 1@ 50 mm
2nd Spacing S-2 = 2@ 100 mm
3rd Spacing S-3 = 3@ 150 mm
4th Spacing S-4 = mm
5th Spacing S - rest = Rest @ 300 mm
For Midspan
Area of Steel
At Tension As = 603.19 mm²
At Compression As' = 402.12 mm²
Effective Depth
At Tension d = 342.00 mm
At Compression d' = 58.00 mm
Compression Block Depth a = 70.96 mm
Steel Stresses
At Tension fs = 1857.90 Mpa
At Compression fs' = 183.16 Mpa
Computed Reduction Factor φf = 0.90
Moments
Ultimate Moment Capacity φMn = 87.72 kN-m
Factored Moment Mu = 55.78 kN-m
Demand-Capacity Ratio DC Ratio = 0.64 SAFE
For Midspan
Area of Steel
At Tension As = 402.12 mm²
At Compression As' = 603.19 mm²
Effective Depth
At Tension d = 342.00 mm
At Compression d' = 58.00 mm
Compression Block Depth a = 47.31 mm
Steel Stresses
At Tension fs = 3086.85 Mpa
At Compression fs' = 0.00 Mpa
Computed Reduction Factor φf = 0.90
Moments
Ultimate Moment Capacity φMn = 47.70 kN-m
Factored Moment Mu = -30.49 kN-m
Demand-Capacity Ratio DC Ratio = 0.64 SAFE
LEFT SUPPORT
0 0 0 0 0 0 0 0 0 0 0
• •
0
0
300 mm
1
• •
0
• •
200 mm
Shear Reinforcements
Bar Diameter d - sec = 10 mm
Bar Spacing Provided
1st Spacing S-1 = 4@ 50 mm
2nd Spacing S-2 = rest @ 200 mm
Minimum Required Reinforcement
Joint S-1 = 3.1 @ 50 mm
Rest S-2 = rest @ 200 mm
Demand - Capacity Ratio DC Ratio = 1.00 SAFE
For Axial
Axial Capacity per axis
Axial Capacity @ x-axis Pux = 645.32 kN
Axial Capacity @ y-axis Puy = 796.55 kN
Pure Axial Capacity Puo = 858.99 kN
Steel to Concrete Ratio ρ% = 2.01%
Forces
Ultimate Axial Capacity φPn = 609.43 kN
Factored Axial Pu = 42.16 kN
Demand - Capacity Ratio DC Ratio = 0.07 SAFE
Column Design C2 Level-1
DESIGN DATA
Concrete
Width @ x-axis Wx = 200 mm
Width @ y-axis Wy = 400 mm
Concrete Cover Cc = 40 mm
Main Bar Diameter d - main = 16 mm
LEFT SUPPORT
0 0 0 0 0 0 0 0 0 0 0
• •
0
0
400 mm
1
• •
0
• •
200 mm
Shear Reinforcements
Bar Diameter d - sec = 10 mm
Bar Spacing Provided
1st Spacing S-1 = 4@ 50 mm
2nd Spacing S-2 = rest @ 200 mm
Minimum Required Reinforcement
Joint S-1 = 3.1 @ 50 mm
Rest S-2 = rest @ 200 mm
Demand - Capacity Ratio DC Ratio = 1.00 SAFE
For Axial
Axial Capacity per axis
Axial Capacity @ x-axis Pux = 449.02 kN
Axial Capacity @ y-axis Puy = 985.78 kN
Pure Axial Capacity Puo = 1056.05 kN
Steel to Concrete Ratio ρ% = 1.51%
Forces
Ultimate Axial Capacity φPn = 435.81 kN
Factored Axial Pu = 83.84 kN
Demand - Capacity Ratio DC Ratio = 0.19 SAFE
Column Design C4 Level-1
DESIGN DATA
Concrete
Width @ x-axis Wx = 250 mm
Width @ y-axis Wy = 550 mm
Concrete Cover Cc = 40 mm
Main Bar Diameter d - main = 16 mm
LEFT SUPPORT
0 0 0 0 0 0 0 0 0 0 0
• •
0
1
• •
0
0
550 mm
1
• •
0
1
• •
0
• •
250 mm
Shear Reinforcements
Bar Diameter d - sec = 10 mm
Bar Spacing Provided
1st Spacing S-1 = 5@ 50 mm
2nd Spacing S-2 = rest @ 250 mm
Minimum Required Reinforcement
Joint S-1 = 3.3 @ 62.5 mm
Rest S-2 = rest @ 250 mm
Demand - Capacity Ratio DC Ratio = 1.00 SAFE
For Axial
Axial Capacity per axis
Axial Capacity @ x-axis Pux = 1517.40 kN
Axial Capacity @ y-axis Puy = 435.63 kN
Pure Axial Capacity Puo = 1801.15 kN
Steel to Concrete Ratio ρ% = 1.46%
Forces
Ultimate Axial Capacity φPn = 416.78 kN
Factored Axial Pu = 130.95 kN
Demand - Capacity Ratio DC Ratio = 0.31 SAFE
Column Design C6 Level-1
DESIGN DATA
Concrete
Width @ x-axis Wx = 250 mm
Width @ y-axis Wy = 600 mm
Concrete Cover Cc = 40 mm
Main Bar Diameter d - main = 16 mm
LEFT SUPPORT
0 0 0 0 0 0 0 0 0 0 0
• •
1
• •
0
1
• •
0
600 mm
1
• •
0
1
• •
0
1
• •
• •
250 mm
Shear Reinforcements
Bar Diameter d - sec = 10 mm
Bar Spacing Provided
1st Spacing S-1 = 5@ 50 mm
2nd Spacing S-2 = rest @ 250 mm
Minimum Required Reinforcement
Joint S-1 = 3.3 @ 62.5 mm
Rest S-2 = rest @ 250 mm
Demand - Capacity Ratio DC Ratio = 1.00 SAFE
For Axial
Axial Capacity per axis
Axial Capacity @ x-axis Pux = 1342.35 kN
Axial Capacity @ y-axis Puy = 899.32 kN
Pure Axial Capacity Puo = 2102.84 kN
Steel to Concrete Ratio ρ% = 1.88%
Forces
Ultimate Axial Capacity φPn = 723.92 kN
Factored Axial Pu = 206.06 kN
Demand - Capacity Ratio DC Ratio = 0.28 SAFE
Column Design C7 Level-1
DESIGN DATA
Concrete
Width @ x-axis Wx = 200 mm
Width @ y-axis Wy = 500 mm
Concrete Cover Cc = 40 mm
Main Bar Diameter d - main = 16 mm
LEFT SUPPORT
0 0 0 0 0 1 0 0 0 0 0
• • •
0
1
• •
0
0
500 mm
1
• •
0
1
• •
0
• • •
200 mm
Shear Reinforcements
Bar Diameter d - sec = 10 mm
Bar Spacing Provided
1st Spacing S-1 = 4@ 50 mm
2nd Spacing S-2 = rest @ 200 mm
Minimum Required Reinforcement
Joint S-1 = 3.1 @ 50 mm
Rest S-2 = rest @ 200 mm
Demand - Capacity Ratio DC Ratio = 1.00 SAFE
For Axial
Axial Capacity per axis
Axial Capacity @ x-axis Pux = 327.39 kN
Axial Capacity @ y-axis Puy = 1382.43 kN
Pure Axial Capacity Puo = 1520.92 kN
Steel to Concrete Ratio ρ% = 2.41%
Forces
Ultimate Axial Capacity φPn = 320.48 kN
Factored Axial Pu = 97.17 kN
Demand - Capacity Ratio DC Ratio = 0.30 SAFE
Footing Design F1
DESIGN DATA
Concrete
Concrete Cover Cc = 75 mm
Bottom Reinforcement
Main Bar Diameter d - main = 12 mm
No. of Rebars perpendicular to X-axis bnx = 6 pcs
No. of Rebars perpendicular to Y-axis bny = 6 pcs
Yield Strength Fy = 275 Mpa
Top Reinforcement
Main Bar Diameter d - main = 0 mm
No. of Rebars perpendicular to X-axis tnx = 0 pcs
No. of Rebars perpendicular to Y-axis tny = 0 pcs
Yield Strength Fy = 0 Mpa
Column 1 Loads (Right Hand Rule)
Axial Load Pu = 42.16 KN
Moment @ X-axis Mx = 10.25, -8.8 KN-m
Moment @ Y-axis My = 27.03, -26.76 KN-m
Column 2 Loads (Right Hand Rule)
Axial Load Pu = 0 KN
Moment @ X-axis Mx = 0, 0 KN-m
Moment @ Y-axis My = 0, 0 KN-m
Column 3 Loads (Right Hand Rule)
Axial Load Pu = 0 KN
Moment @ X-axis Mx = 0, 0 KN-m
Moment @ Y-axis My = 0, 0 KN-m
Column 4 Loads (Right Hand Rule)
Axial Load Pu = 0 KN
Moment @ X-axis Mx = 0, 0 KN-m
Moment @ Y-axis My = 0, 0 KN-m
1 0 0 ↓300 0 0 2
0 0 1 ←200 0 0
Thickness:
300 mm
0 0 0 0 0 0
Y-axis
1000
0 0 0 0 0 0
Depth:
1500 mm
0 0 0 0 0 0
0 0 0 0 0 0
3 X-axis 4
1000
Flexural @ Y-axis
Area of Steel
At Tension As = 678.58 mm²
At Compression As' = 0 mm²
Effective Depth
At Tension d = 207 mm
At Compression d' = 75 mm
Compression Block Depth a = 10.61 mm
Steel Stresses
At Tension fs = 9353.9 MPa
At Compression fs' = 0 MPa
Computed Reduction Factor φf = 0.9
Moments
Ultimate Moment Capacity φMn = 33.87 KN-m
Factored Moment Mu = 12.94 KN-m
Demand-Capacity Ratio DC Ratio = 0.38 SAFE
1 0 0 0 0 0 2
0 0 0 0 0 0
Thickness:
300 mm
0 0 0 0 ↓250 0
Y-axis
2300
0 0 0 0 1 ←600
Depth:
1500 mm
0 0 0 0 0 0
0 0 0 0 0 0
3 X-axis 4
1400
Flexural @ Y-axis
Area of Steel
At Tension As = 3015.93 mm²
At Compression As' = 0 mm²
Effective Depth
At Tension d = 201 mm
At Compression d' = 75 mm
Compression Block Depth a = 30.85 mm
Steel Stresses
At Tension fs = 2722.48 MPa
At Compression fs' = 0 MPa
Computed Reduction Factor φf = 0.9
Moments
Ultimate Moment Capacity φMn = 208.54 KN-m
Factored Moment Mu = 200.48 KN-m
Demand-Capacity Ratio DC Ratio = 0.96 SAFE
1 0 0 0 0 0 2
0 0 0 0 0 0
Thickness:
300 mm
0 0 0 0 ↓500 0
Y-axis
1500
0 0 0 0 1 ←200
Depth:
1500 mm
0 0 0 0 0 0
0 0 0 0 0 0
3 X-axis 4
1500
Flexural @ Y-axis
Area of Steel
At Tension As = 2211.68 mm²
At Compression As' = 0 mm²
Effective Depth
At Tension d = 201 mm
At Compression d' = 75 mm
Compression Block Depth a = 34.69 mm
Steel Stresses
At Tension fs = 2354.77 MPa
At Compression fs' = 0 MPa
Computed Reduction Factor φf = 0.9
Moments
Ultimate Moment Capacity φMn = 151.34 KN-m
Factored Moment Mu = 136.42 KN-m
Demand-Capacity Ratio DC Ratio = 0.90 SAFE
1 0 0 0 0 0 2
0 0 0 0 0 0
Thickness:
300 mm
0 0 0 0 ↓400 0
Y-axis
1200
↓200 0 0 0 2 ←200
Depth:
1500 mm
1 ←300 0 0 0 0
0 0 0 0 0 0
3 X-axis 4
1821.4
Flexural @ Y-axis
Area of Steel
At Tension As = 1608.5 mm²
At Compression As' = 0 mm²
Effective Depth
At Tension d = 201 mm
At Compression d' = 75 mm
Compression Block Depth a = 31.54 mm
Steel Stresses
At Tension fs = 2650.25 MPa
At Compression fs' = 0 MPa
Computed Reduction Factor φf = 0.9
Moments
Ultimate Moment Capacity φMn = 111.01 KN-m
Factored Moment Mu = 102.34 KN-m
Demand-Capacity Ratio DC Ratio = 0.92 SAFE
1 0 0 0 0 0 2
0 0 0 0 0 0
Thickness:
300 mm
1 ←300 0 0 ↓400 0
Y-axis
1400
0 0 0 0 2 ←200
Depth:
1500 mm
0 0 0 0 0 0
0 0 0 0 0 0
3 X-axis 4
1914.6
Flexural @ Y-axis
Area of Steel
At Tension As = 1608.5 mm²
At Compression As' = 0 mm²
Effective Depth
At Tension d = 201 mm
At Compression d' = 75 mm
Compression Block Depth a = 27.03 mm
Steel Stresses
At Tension fs = 3191.96 MPa
At Compression fs' = 0 MPa
Computed Reduction Factor φf = 0.9
Moments
Ultimate Moment Capacity φMn = 112.36 KN-m
Factored Moment Mu = 106.5 KN-m
Demand-Capacity Ratio DC Ratio = 0.95 SAFE