Bently Nevada* Asset Condition Monitoring
Description
The vb8 instrument is a portable four-channel vibration data
collector, analyzer and balancer. You can use this device for
on-route and off-route data collection, machine-side analysis
and diagnosis as well as on-site dynamic balance correction.
Document: 116M5343
Rev. D
Page 1 of 9
such as bearing faults
n Unique 6Pack recording system
n Full analysis capabilities such as time synchronous
averaging, coastdown and runup, bump test, cross-
channel phase, orbit plot, and long time waveform
n Modal Impact Testing and Cross Channel Spectrum
(ODS)
n Ability to export data in Universal File Format (UFF)
for additional analysis in ODS software such as
Vibrant Technology ME'scope
n Numeric parameter input via keypad with trend and
alarm capability
n Sensor cable self-test feature
n Flex feature to add Remote Comms
n USB host port for data transfer to external USB
drive
n Upgradable Proflash system and free firmware
updates for 5 years
n Five-year warranty on the instrument hardware
Document: 116M5343
Rev. D
Page 2 of 9
Specifications Tachometer Sensor
Sensors Sensor type
Laser sensor with reflective tape
Sensor triggers on beam reflection
Sensor input Four channels simultaneous sampling Laser sensor 10 cm to 2 m nominal
Compatible Accelerometer, velocity, displacement, current, range Range depends on size of reflective tape
sensor types voltage output and 4 to 20 mA
16 V peak-peak Tachometer Input
AC coupled
Allows for ± 8 V sensor output swing
range Laser Tach, Contact, TTL Pulse, Keyphasor*
(± 80 g) Supported
sensor types Instrument has optically isolated input
0 V to 20 V,
DC coupled -10 V to 10 V, Power supply to
-20 V to 0 V 5 V, 50 mA
ranges sensor
E.g. For reading prox-probe gap 3.5 V (4 mA) min
1 x BNC (CH1) TTL pulse rating 28 V (5 mA) max
1 x LEMO (CH2/CH3/CH4) Off-state 0.8 V
Connectors
7.7 ± 0.5 V,
Safety feature: Break-free inline connector
Keyphasor* 13.2 ± 0.8 V,
Analog to digital thresholds 18.5 ± 1 V
24-bit ADC
conversion
Nominally 8 V, 13 V, 18 V
0 mA or 2.2 mA (configurable),
Sensor 24 V maximum 10 RPM to 300,000 RPM
excitation Speed range (0.2 Hz to 5 kHz)
current 2.2 mA required power for IEPE/ICP ® type
accelerometer Pulse width at least 0.1 ms
Document: 116M5343
Rev. D
Page 3 of 9
Parameter Indication
> 1000 g (10,000 m/s2) ≤ 0.1 dB 10 Hz to <100 Hz
> 1000 in/sec (25,000 mm/s) ≤ 1.5 dB 1 Hz to <10 Hz
Attenuation
Maximum > 20 in (500 mm)
> 10,000 amps due to Values apply to single integration.
levels (peak) Integration (Acceleration to velocity)
Effective limit is sensor sensitivity and output (normal mode)
voltage Double the values for double integration
(Acceleration to displacement)
Dynamic signal > 95 dB
Attenuation
range typical at 400 line resolution ≤ 0.1 dB 1 Hz to <100 Hz
due to
Less than -70 dB typical Integration (low ≤ 1.5 dB 0.2 Hz to <1 Hz
Harmonic
frequency Applies when coupling = DC and Fmax ≤ 100 Hz
distortion Other distortions and noise are lower mode)
g or m/s2 or adB
in/s or mm/s or vdB
mil or mm or µm
adB, vdB, amps, user defined
Units
0-peak, peak-peak or RMS
Auto-scale by 1000x when required
US and SI options for adB and vdB
Overall RMS value
Waveform True pk-pk
Magnitude & Dual cursors
cursors Harmonics
Digital readouts on chart
± 1% of readings
approximately 0.1 dB
Base accuracy
For AC signal: % of reading
For DC signal: % of full scale
≤ 0.1 dB 100 Hz to 10 kHz
High frequency ≤ 3 dB >10 kHz to 40 kHz
attenuation Attenuation tolerances are in addition to base
accuracy.
AC coupling ≤ 0.1 dB 10 Hz to <100 Hz
attenuation ≤ 3 dB 1 Hz to <10 Hz
Document: 116M5343
Rev. D
Page 4 of 9
Spectrum Display Time scale
10 ms to 512 seconds
or orders based from 1 to 999 revs
25, 50, 100, 125, 150, 200, 300, 400, 500, 600, 800,
Time 1, 2, 4, 8, 16, 32, 64, 128
1000, 1200, 1600, 2000, 2500, 3000, 4000, 5000,
synchronous
6000, 8000, 10,000, 15,000, 20,000, 30,000, 40,000, Only available when tachometer triggered
Fmax ranges 60,000, 80,000 Hz averages
Long time 25 Hz to 40 kHz
Or equivalent CPM values waveform
Or orders-based from 1X to 999X Fmax 20 kHz max for two or more channels
Number of 1 reference
1024, 2048, 4096, 8192, 16,384, 32,768 Up to 3 other sensors
samples Cross channel
spectrum Coherence and FRF for importing into ODS
software
Document: 116M5343
Rev. D
Page 5 of 9
Balancing Battery and Charger
Up to 2 planes Battery type Custom Lithium Ion pack, 7.4 V, 5 Ah
Planes
2 sensors
10 hours
Speed range 30 to 60 000 RPM Operating time
Backlight on — 60 second timeout
Acceleration Internal charging, automatic control
Measurement Charger type
Velocity External power pack 12 V DC, 3 A output
type
Displacement
3 A nominal
Angle 0° to 360° Charge rate
3 hours for complete charge
Fixed position
Circumference arc
Weight modes Mechanical
E.g. Weights on fan blades, linear dist. around
circumference 9.9" W x 5.8" L x 2.4" H
Size
(252 x 148 x 60 mm)
Remove trial Leave or remove trial weights for final balance
weights 2.7 lb (1.2 kg)
Automatic recalculation Weight
Including battery and strap
Manual data Yes
entry Allows re-entry of previous balance jobs Environmental Limits
In the data structure where machine vibration Operating
Storage of readings are stored 14 °F to 122 °F (-10 to 50 °C)
temperature
balancing jobs
No limits applied -4 °F to 140 °F (-20 to 60 °C), 95% RH
Storage
temperature & Up to 95 F (35 C), 85% RH if storage exceeds 1
Display and Communication humidity month
CSA/NRTL/C
Class I, Division 2,
(Approval
Groups A, B, C, D
Option 01)
Document: 116M5343
Rev. D
Page 6 of 9
DCCA0041 DC car adapter 1
Ordering Information SCOUT100 Series and vbSeries Quick
108M3536 1
Start Guide
For a detailed listing of country and product
MVBX0250 Instrument Reference guide 1
specific approvals, refer to the Approvals Quick
Reference Guide (108M1756) at Accessory Kits
www.GEmeasurement.com.
Balancing Kit - 108M4050-04
VB8-AXX
A: Agency Approval Part Number Description Qty
01 CSA / NRTL / C (Class 1, Division 2) Reflective tape
113M5529-01 1
One roll, 60 cm
Basic Kit Laser Tach Kit
LASA0315 1
Zone 2 rated
We offer the vb8 instrument in a basic kit with
Laser cable
the option to purchase System 1 or Ascent CBL50216
Five meters
1
software and license separately. MAGA0063 Laser magnetic stand 1
Document: 116M5343
Rev. D
Page 7 of 9
Impact Hammer Kit Additional Accessories
Impact_Hammer_Kit - Software
AXX-BXX-CXX-DXX-EXX-FXX
Part Number Description
A: 500lbf pk, 10mV/lbf, 0.3lbm (285570-01) 108M4051 ASCENT Level 1
00 None
108M4052 ASCENT Level 2
01 Hammer Included
B: 1000lbf pk, 5mV/lbf, 0.3lbm (285570-02) 3071/01 System 1
00 None
01 Hammer Included
C: 5000lbf pk, 1mV/lbf, 2.4lbm (285570-03)
Miscellaneous Parts
00 None
01 Hammer Included Part Number Description
D: NA Accelerometer magnetic base
E: NA MAGM0064
Male connection
F: NA
Keyphasor cable
KEY70258
BNC to LEMO
VBMR0222 Stainless safety rings (1 pair)
100M5828 The vbSeries hard case
DTC70262 The vbSeries dust cover
BATT0575 Replacement battery pack, Li-Ion 7.4 V 5 Ah
Document: 116M5343
Rev. D
Page 8 of 9
Copyright 2016 - 2018 Baker Hughes, a GE company, LLC ("BHGE") All rights reserved.
* Denotes a trademark of Bently Nevada, LLC, a wholly owned
subsidiary of Baker Hughes, a GE company.
All product and company names are trademarks of their respective holders.
Use of the trademarks does not imply any affiliation with or endorsement by the respective holders.
The information contained in this document is subject to change without prior notice.
1631 Bently Parkway South, Minden, Nevada USA 89423
Phone: 1-775.782.3611 www.GEmeasurement.com
Document: 116M5343
Rev. D
Page 9 of 9