0% found this document useful (0 votes)
38 views

1 Input Data: Profis Anchor 2.8.5

This document provides an analysis of anchor forces for a proposed anchor installation. It includes: 1. Input data on the anchor type, material properties, load case, and geometry. 2. Calculations of tension and shear forces on individual anchors under the design load case, with the maximum resulting tension force being 1.592 kN. 3. Evaluation of the anchor capacities in tension, including steel strength, pullout strength, concrete breakout strength, and splitting failure, confirming the design is acceptable. 4. Evaluation of the anchor capacities in shear, including steel strength, pryout strength, and concrete edge failure, again confirming the design is acceptable.

Uploaded by

Nithin M.T
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
38 views

1 Input Data: Profis Anchor 2.8.5

This document provides an analysis of anchor forces for a proposed anchor installation. It includes: 1. Input data on the anchor type, material properties, load case, and geometry. 2. Calculations of tension and shear forces on individual anchors under the design load case, with the maximum resulting tension force being 1.592 kN. 3. Evaluation of the anchor capacities in tension, including steel strength, pullout strength, concrete breakout strength, and splitting failure, confirming the design is acceptable. 4. Evaluation of the anchor capacities in shear, including steel strength, pryout strength, and concrete edge failure, again confirming the design is acceptable.

Uploaded by

Nithin M.T
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

www.hilti-me.com Profis Anchor 2.8.

5
Company: FENCON Page: 1
Specifier: Project: SKYDIVE
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 12/11/2019
E-Mail:

Specifier's comments:

1 Input data
Anchor type and diameter: HST3-R M10 hef1
Seismic/Filling set or any suitable annular gap filling solution
Effective embedment depth: hef = 40 mm, hnom = 48 mm
Material: A4
Evaluation Service Report: ETA-98/0001
Issued I Valid: 2/9/2018 | -
Proof: Engineering judgement SOFA - based on ETAG testing
Stand-off installation: eb = 0 mm (no stand-off); t = 14 mm
Anchor plate: ALUMINIUM; E = 70,000.00 N/mm2; fyk = 160.00 N/mm2; gMs = 1.200
lx x ly x t = 1,043 mm x 55 mm x 14 mm; (Recommended plate thickness: calculated (2 mm))
Profile: Double flat bar, ; (L x W x T) = 1,043 mm x 55 mm x 14 mm
Base material: cracked concrete, C25/30, fc,cube = 30.00 N/mm2; h = 150 mm
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement

R
- The anchor calculation is based on a rigid anchor plate assumption.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.8.5
Company: FENCON Page: 2
Specifier: Project: SKYDIVE
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 12/11/2019
E-Mail:

2 Load case/Resulting anchor forces y


Load case: Design loads

Anchor reactions [kN]


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 0.531 0.044 0.000 -0.044
2 0.822 0.044 0.000 -0.044 2 1 3 x 4
3 0.240 0.044 0.000 -0.044 Tension Compression
4 0.000 0.044 0.000 -0.044

max. concrete compressive strain: 0.02 [‰]


max. concrete compressive stress: 0.46 [N/mm2]
resulting tension force in (x/y)=(-260/0): 1.592 [kN]
resulting compression force in (x/y)=(480/0): 1.555 [kN]

Anchor forces are calculated based on the assumption of a rigid anchor plate.

3 Tension load (ETAG, Annex C, Section 5.2.2)


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel Strength* 0.822 20.500 5 OK
Pullout Strength* N/A N/A N/A N/A
Concrete Breakout Strength** 1.592 11.529 14 OK
Splitting failure** N/A N/A N/A N/A
* anchor having the highest loading **anchor group (anchors in tension)

3.1 Steel Strength


NRk,s [kN] gM,s NRd,s [kN] NSd [kN]
28.700 1.400 20.500 0.822

3.2 Concrete Breakout Strength


Ac,N [mm2] A0c,N [mm2] ccr,N [mm] scr,N [mm]
43,200 14,400 60 120
ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N
110 0.578 0 1.000 1.000 1.000
k1 N0Rk,c [kN] gM,c NRd,c [kN] NSd [kN]
7.200 9.977 1.500 11.529 1.592

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.8.5
Company: FENCON Page: 3
Specifier: Project: SKYDIVE
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 12/11/2019
E-Mail:

4 Shear load (ETAG, Annex C, Section 5.2.3)


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel Strength (without lever arm)* 0.044 20.480 1 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 0.174 71.033 1 OK
Concrete edge failure in direction y-** 0.174 165.602 1 OK
* anchor having the highest loading **anchor group (relevant anchors)

4.1 Steel Strength (without lever arm)


VRk,s [kN] gM,s VRd,s [kN] VSd [kN]
25.600 1.250 20.480 0.044

4.2 Pryout Strength


Ac,N [mm2] A0c,N [mm2] ccr,N [mm] scr,N [mm] k-factor
57,600 14,400 60 120 2.670
ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N
0 1.000 0 1.000 1.000 1.000
N0Rk,c [kN] gM,c,p VRd,cp [kN] VSd [kN]
9.977 1.500 71.033 0.174

4.3 Concrete edge failure in direction y-


lf [mm] dnom [mm] k1 a b
40 10.0 1.700 0.014 0.035
c1 [mm] Ac,V [mm2] A0c,V [mm2]
1,971 1,021,950 17,481,785
y s,V y h,V y a,V ec,V [mm] y ec,V y re,V
1.000 4.440 1.000 0 1.000 1.000
V0Rk,c [kN] gM,c VRd,c [kN] VSd [kN]
957.129 1.500 165.602 0.174

5 Combined tension and shear loads (ETAG, Annex C, Section 5.2.4)

Steel failure
bN bV a Utilization bN,V [%] Status
0.138 0.002 1.500 6 OK
baN + baV ≤ 1.0

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.8.5
Company: FENCON Page: 4
Specifier: Project: SKYDIVE
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 12/11/2019
E-Mail:

6 Displacements (highest loaded anchor)


Short term loading:
NSk = 0.609 [kN] dN = 0.085 [mm]
VSk = 0.032 [kN] dV = 0.008 [mm]
dNV = 0.085 [mm]
Long term loading:
NSk = 0.609 [kN] dN = 0.184 [mm]
VSk = 0.032 [kN] dV = 0.012 [mm]
dNV = 0.184 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements are
valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not included in
this calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

7 Warnings
• The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.). This
means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be
sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum required anchor plate
thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate
assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the existing conditions and
for plausibility! 
• Checking the transfer of loads into the base material is required in accordance with ETAG 001, Annex C(2010)Section 7! The software considers
that the grout is installed under the anchor plate without creating air voids and before application of the loads.
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of ETAG 001, Annex C! For larger
diameters of the clearance hole see Chapter 1.1. of ETAG 001, Annex C!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to be
followed to ensure a proper installation.
• The design method SOFA assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by filling the gap
with mortar of sufficient compressive strength (e.g. by using the HILTI Seismic/Filling set) or by other suitable means
• The compliance with current standards (e.g. EC3) is the responsibility of the user
• An SLS-check is not performed for SOFA and has to be provided by the user!

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.8.5
Company: FENCON Page: 5
Specifier: Project: SKYDIVE
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 12/11/2019
E-Mail:

8 Installation data
Anchor plate, steel: ALUMINIUM; E = 70,000.00 N/mm2; fyk = 160.00 Anchor type and diameter: HST3-R M10 hef1
N/mm
Profile: Double flat bar, ; (L x W x T) = 1,043 mm x 55 mm x 14 mm Installation torque: 0.045 kNm
Hole diameter in the fixture: df = 12 mm Hole diameter in the base material: 10 mm
Plate thickness (input): 14 mm Hole depth in the base material: 55 mm
Recommended plate thickness: calculated (2 mm) Minimum thickness of the base material: 80 mm
Drilling method: Hammer drilled
Cleaning: Manual cleaning of the drilled hole according to instructions
for use is required.

8.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Manual blow-out pump • Hilti SIW 22T-A impact screw driver
• Properly sized drill bit • Seismic/Filling set
• Torque wrench
• Hammer

522 522

28 28

28 28
2 1 3 4 x

72 300 300 300 72

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -150 0 - - 1,971 372
2 -450 0 - - 1,971 372
3 150 0 - - 1,971 372
4 450 0 - - 1,971 372

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.8.5
Company: FENCON Page: 6
Specifier: Project: SKYDIVE
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 12/11/2019
E-Mail:

9 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and
security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly
complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using
the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in.
Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you.
Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms
and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific
application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the
regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use
the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
HST3 (-R) subject to:
Anchor size M8 M10 M12 M16 M20 M24
Hammer drilling*

TE2(-A) – TE30(-A) TE40 – TE70

Diamond core drilling*

DD-30W, DD-EC1

Setting tool*
Setting tool HS-SC -

Hollow drill bit drilling*

- TE-CD, TE-YD

Seismic Set/ Filling Set**

Seismic/Filling Set M8-M20 (Carbon and Stainless Steel A4) -

*Installation methods provided in ETA-98/0001


**Seismic set needed to fill the annular gap between anchor and fixture:
No annular gap, double design resistance (agap=1)