Pump Slave MICRO Parameters PDF

This document provides instructions for setting up and configuring an iQpump Micro network. It includes: 1) A network configuration diagram showing how to wire the drives together using shielded communication cables. Each drive must have a unique serial address. 2) A 7-step process for manually setting up the network that involves wiring, setting serial addresses, programming controller parameters, recycling power, and verifying communication. 3) Default parameter settings for configuring the individual iQpump Micro drives on the network.

Uploaded by

albeiro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
79 views

Pump Slave MICRO Parameters PDF

This document provides instructions for setting up and configuring an iQpump Micro network. It includes: 1) A network configuration diagram showing how to wire the drives together using shielded communication cables. Each drive must have a unique serial address. 2) A 7-step process for manually setting up the network that involves wiring, setting serial addresses, programming controller parameters, recycling power, and verifying communication. 3) Default parameter settings for configuring the individual iQpump Micro drives on the network.

Uploaded by

albeiro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 15

Parameter Settings Report (Program) 26/11/2018 3:58:25 p. m.

Program (Drive Selected / Connected):


Drive Type / Model: iQpump Micro CIMR-PW2V0040***
Software: 10100

Project:
User:

Information

Network Configuration

H5-01=01 | H5-01=02 |

Note: Each iQpump Micro drive must have its own unique serial address (H5-01)
Use shielded communication cables to connect all iQpump Micro drives.
Connect all iQpump Micro drives according to the wiring shown above. (R+ to S+ and R- to S-)

DriveWizard iQpump for Windows (C) by Yaskawa America, Inc. 1/15


26/11/2018 3:58:25 p. m.
iQpump Micro Network Quick Start Instructions:
Note: Follow these instructions to setup your iQpump Micro network manually.

Step 1:
Wire all iQpump Micro drives according to the network configuration diagram (R+/R-/S+/S-) as shown on the first page of
this report.
Use shielded communication cables to connect all iQpump Micro drives.
Step 2:
Set Serial communication address parameter H5-01 for each iQpump Micro drive as shown on the first page of this report.

Step 3:
Program each iQpump controller parameter P9-25 (Highest Node Address) to: X
Step 4:
Program each iQpump controller parameter P1-01 (Pump Mode) to 3:
Step 5:
Recycle power to ALL iQpump Micro drives on the network.
Step 6:
Check U9-02 and verify that :
- No iQpump Micro drives have a value of "- 0"
- All iQpump Micro drives receive valid data and U9-02 changes regularly.
- At least one iQpump Micro drive has the unit , while the rest have the unit .

If there is an iQpump Micro drive with "- 0":


- Check communication wiring as shown on first page of this report
- Verify the serial communication address (H5-01) as shown on first page of this report
- Confirm P9-25 and P9-27 settings on all drives. P9-25 should be set to the highest H5-01 address and atleast one
iQpump Micro drive should have P9-27 = 0.
- Cycle power to all iQpump Micro drives.
Step 7:
Program each iQpump Micro drive on the network using the parameter list shown on the next page.

Step 8:
Verify pump rotation using hand mode operation. If rotation is incorrect, power-down the iQpump Micro drive and wait 5
minutes. Using Safety precaution, swap any two of the three output leads to the motor (U/T1, V/T2 and W/T3).
After the wiring change recheck motor direction using hand operation.

Step 9:
Ready to run pump system.

Digital operator control:


- Press Auto button on ALL the digital operators to initiate Auto mode operation.
Contact / Terminal Control:
- Close run contact on terminals on all iQpump controllers to initiate Auto mode operation.
Default
Parameter Value Information Setting

A1-01 Access level 2 Advanced Level 2


A1-02 Control method 0 V/f control 0
A1-03 Initialize Parameters 0 No Initialization 0
A1-04 Enter password 0 0
A1-05 Select password 0 0
A1-06 Application Preset 0 Pressure Control 0
A1-07 DWEZ Function Selection 0 Disabled 0

A2-01 User parameter 1 E2-01 Motor rated current E2-01


A2-02 User parameter 2 E2-04 Number of motor poles E2-04
A2-03 User parameter 3 P1-03 Feedback Scaling P1-03
A2-04 User parameter 4 Q1-01 PID Controller Setpoint 1 Q1-01
A2-05 User parameter 5 P1-04 Start / Draw Down Level P1-04
A2-06 User parameter 6 P1-06 Minimum Pump Speed P1-06
A2-07 User parameter 7 P4-10 AUTO Mode Operator Run Power Down Storage P4-10
A2-08 User parameter 8 P5-04 HAND Key Function Selection P5-04
A2-09 User parameter 9 Not Mapped -N/M-
A2-10 User parameter 10 Not Mapped -N/M-
A2-11 User parameter 11 Not Mapped -N/M-
A2-12 User parameter 12 Not Mapped -N/M-
A2-13 User parameter 13 Not Mapped -N/M-
A2-14 User parameter 14 Not Mapped -N/M-
A2-15 User parameter 15 Not Mapped -N/M-
A2-16 User parameter 16 Not Mapped -N/M-
A2-17 User parameter 17 Not Mapped -N/M-
A2-18 User parameter 18 Not Mapped -N/M-
A2-19 User parameter 19 Not Mapped -N/M-
A2-20 User parameter 20 Not Mapped -N/M-
A2-21 User parameter 21 Not Mapped -N/M-
A2-22 User parameter 22 Not Mapped -N/M-
A2-23 User parameter 23 Not Mapped -N/M-
A2-24 User parameter 24 Not Mapped -N/M-
A2-25 User parameter 25 Not Mapped -N/M-
A2-26 User parameter 26 Not Mapped -N/M-
A2-27 User parameter 27 Not Mapped -N/M-
A2-28 User parameter 28 Not Mapped -N/M-
A2-29 User parameter 29 Not Mapped -N/M-
A2-30 User parameter 30 Not Mapped -N/M-
A2-31 User parameter 31 Not Mapped -N/M-
A2-32 User parameter 32 Not Mapped -N/M-
A2-33 User parameter Automatic registration 0 Automatic registration is unavailable(Totally user setting from 0
Function A2-01 toA2-32)

b1-01 Reference selection 0 Digital operator 0


1 Control circuit terminal 0
0 Deceleration to stop 1
b1-04 Reverse operation 1 Reverse disabled 1

3/15
Default
Parameter Value Information Setting
b1-07 Run Command Retention when Source is 0 Require Cycle 0
Changed
1 Enabled - Run command accepted in all menus (except when 0
b1-02 = 0).
b1-11 Run Delay at Stop 0,0 sec 0,0 sec
b1-12 Run Delay Memory Selection 2 Running & Stop 2
1 Exchange the Phase turn (without PG only) 0
b1-15 Reference Selection in Local case 0 Digital Operator 0
b1-16 Operation method selection in Local case 0 Digital Operator 0
b1-17 Operation permission with power ON/OFF 1 Permission 1

b2-01 DC injection start frequency 0,5 Hz 0,5 Hz


b2-02 DC injection current 50 % 50 %
b2-03 DC injection time at start 0,00 sec 0,00 sec
b2-04 DC injection time at stop 0,50 sec 0,50 sec

b3-01 Speed search at start 0 Disabled 0


b3-02 Speed search current 120 % 120 %
b3-03 Speed search deceleration time 2,0 sec 2,0 sec
b3-05 Search wait time 0,2 sec 0,2 sec
b3-06 Output current 0,5 A 0,5 A
b3-08 ACR Gain for Speed Search 0,50 0,50
b3-10 Speed Search Detection Compensation Gain 1,05 1,05
b3-14 Bidirectional search selection 0 Disabled 0
b3-17 Retry current level 150 % 150 %
b3-18 Retry detection time 0,10 sec 0,10 sec
b3-19 Retry count 3 3
b3-24 Speed search method selection 0 Current detection type 0
b3-25 Speed search retry interval time 0,5 sec 0,5 sec

b4-01 Delay-ON timer 0,0 sec 0,0 sec


b4-02 Delay-OFF timer 0,0 sec 0,0 sec

b5-01 PID control mode selection 1 Enabled 1


2,30 2,00
1,3 sec 3,0 sec
b5-04 PID I limit 100,0 % 100,0 %
b5-05 PID D time 0,00 sec 0,00 sec
b5-06 PID limit 100,0 % 100,0 %
b5-07 PID offset adjustment 0,0 % 0,0 %
1,00 sec 0,00 sec
b5-09 Output level selection 0 Direct Acting 0
b5-10 PID output gain 1,00 1,00
b5-11 PID output reverse selection 0 0 limit when PID putput is negative 0
b5-12 Feedback Loss 4 to 20mA Detection 2 Fault 2
Selection
b5-13 Feedback Loss Goto Frequency 0,0 Hz 0,0 Hz
b5-14 Feedback Loss of Prime Level 0,0 A 0,0 A
b5-15 Feedback Loss Go To Frequency Time Out 0 sec 0 sec
b5-16 Feedback Loss Start Delay 0,0 sec 0,0 sec

4/15
Default
Parameter Value Information Setting
b5-17 Accel/Decel time for PID reference 0 sec 0 sec
b5-32 Integrator Ramp Limit 0,0 Hz 0,0 Hz
b5-34 PID Output Lower Limit 0,0 % 0,0 %
b5-35 PID Input Limit 1000,0 % 1000,0 %
b5-39 PID Setpoint Set up/Display Number of 1 One decimal place 1
decimals
b5-40 PID Fref monitor Selection 0 Fref Monitor with PID 0
b5-47 PID Output Reverse Selection2 1 Reverses when PID output is negative. 1

b6-01 Dwell frequency at start 0,0 Hz 0,0 Hz


b6-02 Dwell time at start 0,0 sec 0,0 sec
b6-03 Dwell frequency at stop 0,0 Hz 0,0 Hz
b6-04 Dwell time at stop 0,0 sec 0,0 sec

3,0 sec 20,0 sec


5,0 sec 10,0 sec
C1-03 Acceleration time 2 10,0 sec 10,0 sec
C1-04 Deceleration time 2 10,0 sec 10,0 sec
C1-09 Emergency stop time 10,0 sec 10,0 sec
C1-10 Accel/Decel time setting unit 1 0.1-second units 1
C1-11 Accel/Decel switching frequency 0,0 Hz 0,0 Hz
C1-14 Picking up speed and slowing down rate 0,0 Hz 0,0 Hz
setting standard frequency

C2-01 S-curve acceleration at start 0,20 sec 0,20 sec


C2-02 S-curve acceleration at end 0,20 sec 0,20 sec
C2-03 S-curve deceleration at start 0,20 sec 0,20 sec
C2-04 S-curve deceleration at end 0,00 sec 0,00 sec

C3-01 Slip compensation gain 0,0 0,0


C3-02 Slip compensation time 2000 ms 2000 ms
C3-03 Slip compensation limit 200 % 200 %
C3-04 Slip compensation regeneration 0 Disabled 0

C4-01 Torque compensation gain 1,00 1,00


C4-02 Torque compensation time 200 ms 200 ms

C6-02 Carrier frequency selection 07 Swing-PWM1 07

d1-01 Frequency reference 1 0,00 Hz 0,00 Hz


d1-02 Frequency reference 2 0,00 Hz 0,00 Hz
d1-03 Frequency reference 3 0,00 Hz 0,00 Hz
d1-04 Frequency reference 4 0,00 Hz 0,00 Hz
d1-05 Frequency reference 5 0,00 Hz 0,00 Hz
d1-06 Frequency reference 6 0,00 Hz 0,00 Hz
d1-07 Frequency reference 7 0,00 Hz 0,00 Hz
d1-08 Frequency reference 8 0,00 Hz 0,00 Hz
d1-09 Frequency reference 9 0,00 Hz 0,00 Hz
d1-10 Frequency reference 10 0,00 Hz 0,00 Hz

5/15
Default
Parameter Value Information Setting
d1-11 Frequency reference 11 0,00 Hz 0,00 Hz
d1-12 Frequency reference 12 0,00 Hz 0,00 Hz
d1-13 Frequency reference 13 0,00 Hz 0,00 Hz
d1-14 Frequency reference 14 0,00 Hz 0,00 Hz
d1-15 Frequency reference 15 0,00 Hz 0,00 Hz
d1-16 Frequency reference 16 0,00 Hz 0,00 Hz
d1-17 Jog frequency reference 6,00 Hz 6,00 Hz

d2-01 Frequency reference upper limit 100,0 % 100,0 %


d2-02 Frequency reference lower limit 0,0 % 0,0 %
d2-03 Master speed reference lower limit 0,0 % 0,0 %

d3-01 Jump frequency 1 0,0 Hz 0,0 Hz


d3-02 Jump frequency 2 0,0 Hz 0,0 Hz
d3-03 Jump frequency 3 0,0 Hz 0,0 Hz
d3-04 Jump frequency width 1,0 Hz 1,0 Hz

d4-01 MOP reference memory 0 Disabled 0


d4-03 Frequency reference bias steps(up/down2) 0,00 Hz 0,00 Hz
d4-04 Accel/Decel rate selection(up/down2) 0 Bias value Accel/Decel at the rate of current selected 0
Accel/Decel time
d4-05 Bias mode selection(up/down2) 0 Hold bias value while both of UP/DOWN command are 0
ON/OFF
d4-06 Bias value(up/down2) 0,0 % 0,0 %
d4-07 Analog change limit 1,0 % 1,0 %
d4-08 Frequency Reference Bias Upper Limit 100,0 % 100,0 %
(up/down2)
d4-09 Frequency Reference Bias Lower Limit 0,0 % 0,0 %
(up/down2)
d4-10 Up/Down Frequency Reference Limit 0 The lower limit is determined by d2-02 or analog input 0
Selection (H3-02/10 = 0)

E1-01 Input voltage setting 230 VAC 230 VAC


E1-03 V/F pattern selection 0F User-defined V/f pattern 0F
E1-04 Max. output frequency 60,0 Hz 60,0 Hz
E1-05 Max. voltage 230,0 VAC 230,0 VAC
E1-06 Base frequency 60,0 Hz 60,0 Hz
E1-07 Mid output frequency 3,0 Hz 3,0 Hz
E1-08 Mid output frequency voltage 16,1 VAC 16,1 VAC
E1-09 Min. output frequency 1,5 Hz 1,5 Hz
E1-10 Min. output frequency voltage 8,1 VAC 8,1 VAC
E1-11 Mid output frequency 2 0,0 Hz 0,0 Hz
E1-12 Mid output frequency voltage 2 0,0 VAC 0,0 VAC
E1-13 Base voltage 0,0 VAC 0,0 VAC

E2-01 Motor rated current 39,70 A 39,70 A


E2-02 Motor rated slip 1,70 Hz 1,70 Hz
12,00 A 11,20 A
E2-04 Number of motor poles 2 2
E2-05 Motor line-to-line resistance 0,230 Ohm 0,230 Ohm
E2-06 Motor leak inductance 19,5 % 19,5 %
E2-10 Torque compensation iron loss 245 W 245 W

6/15
Default
Parameter Value Information Setting
E2-11 Motor rated output 11,00 kW 11,00 kW

F6-01 Operation selection after communications 1 Coast to stop 1


error
F6-02 Selection of External Fault from 0 Always detect 0
Communication Option Board
F6-03 Stopping Method for External Fault from 1 Coast to Stop 1
Communication Option Board
F6-04 BUS error detection delay 2,0 sec 2,0 sec
F6-07 Fref Priority Selection 1 MultiStep Speed is vailable. 1
F6-08 Comm Parameter Initialize Selection 0 Comm Parameters are not initialized due to A1-02. 0
F6-10 Node Address 0 0
F6-11 Communication Speed 0 156 Kbps 0
F6-14 BUS Error Auto Reset 0 Disabled 0
F6-20 M-II Station Address 21 21
F6-21 M-II Frame length 0 32byte mode 0
F6-22 M-II Link Speed 0 10 Mbps 0
F6-23 M-II Mon E register 0000 0000
F6-24 M-II Mon F register 0000 0000
F6-25 M-II WDT error selection 1 Coast to stop 1
F6-26 M-II Number of bUS error detection 2 2
F6-30 Node Address 0 0
F6-31 Clear Mode Selection 0 Resets back to zero. 0
F6-32 ProfibusMap Selection 0 PPO Type 0
F6-35 CanOpen Node Address 0 0
F6-36 Communication Speed 6 500 Kbps 6
F6-40 Node Address 0 0
F6-41 Communication Speed 1 Auto-adjust 1
F6-50 MAC Address 64 64
F6-51 Baud Rate 4 Detect automatically 4
F6-52 PCA Setting 21 21
F6-53 PPA Setting 71 71
F6-54 Idle Mode Fault Detection 0 No Detection 0
F6-56 Speed Scaling 0 0
F6-57 Current Scaling 0 0
F6-58 Torque Scaling 0 0
F6-59 Power Scaling 0 0
F6-60 Voltage Scaling 0 0
F6-61 Time Scaling 0 0
F6-62 Heart Beat 0 0
F6-64 Dynamic Output Assembly 109 Parameter 1 0000 0000
F6-65 Dynamic Output Assembly 109 Parameter 2 0000 0000
F6-66 Dynamic Output Assembly 109 Parameter 3 0000 0000
F6-67 Dynamic Output Assembly 109 Parameter 4 0000 0000
F6-68 Dynamic Input Assembly 159 Parameter 1 0000 0000
F6-69 Dynamic Input Assembly 159 Parameter 2 0000 0000
F6-70 Dynamic Input Assembly 159 Parameter 3 0000 0000
F6-71 Dynamic Input Assembly 159 Parameter 4 0000 0000
F6-72 Node Address 0 0

7/15
Default
Parameter Value Information Setting
F7-01 IP Address1 192 192
F7-02 IP Address2 168 168
F7-03 IP Address3 1 1
F7-04 IP Address4 20 20
F7-05 Subnet Mask1 255 255
F7-06 Subnet Mask2 255 255
F7-07 Subnet Mask3 255 255
F7-08 Subnet Mask4 0 0
F7-09 Gateway Address1 192 192
F7-10 Gateway Address2 168 168
F7-11 Gateway Address3 1 1
F7-12 Gateway Address4 1 1
F7-13 Address Startup Mode 2 2
F7-14 Duplex Mode Setting 1 Auto Negotiate 1
F7-15 Speed Mode Setting 10 10 Mbps speed setting 10
F7-16 Timeout Value 0 0
F7-17 Speed Scaling 0 0
F7-18 Current Scaling 0 0
F7-19 Torque Scaling 0 0
F7-20 Power Scaling 0 0
F7-21 Voltage Scaling 0 0
F7-22 Time Scaling 0 0
F7-23 Dynamic Output Assembly 116 Parameter 1 0000 0000
F7-24 Dynamic Output Assembly 116 Parameter 2 0000 0000
F7-25 Dynamic Output Assembly 116 Parameter 3 0000 0000
F7-26 Dynamic Output Assembly 116 Parameter 4 0000 0000
F7-27 Dynamic Output Assembly 116 Parameter 5 0000 0000
F7-28 Dynamic Output Assembly 116 Parameter 6 0000 0000
F7-29 Dynamic Output Assembly 116 Parameter 7 0000 0000
F7-30 Dynamic Output Assembly 116 Parameter 8 0000 0000
F7-31 Dynamic Output Assembly 116 Parameter 9 0000 0000
F7-32 Dynamic Output Assembly 116 Parameter 10 0000 0000
F7-33 Dynamic Input Assembly 166 Parameter 1 0000 0000
F7-34 Dynamic Input Assembly 166 Parameter 2 0000 0000
F7-35 Dynamic Input Assembly 166 Parameter 3 0000 0000
F7-36 Dynamic Input Assembly 166 Parameter 4 0000 0000
F7-37 Dynamic Input Assembly 166 Parameter 5 0000 0000
F7-38 Dynamic Input Assembly 166 Parameter 6 0000 0000
F7-39 Dynamic Input Assembly 166 Parameter 7 0000 0000
F7-40 Dynamic Input Assembly 166 Parameter 8 0000 0000
F7-41 Dynamic Input Assembly 166 Parameter 9 0000 0000
F7-42 Dynamic Input Assembly 166 Parameter 10 0000 0000

H1-01 Terminal S1 function selection 40 Forward Run Command 40


H1-02 Terminal S2 function selection 0F Not used(Unused / when use it as a pass-through mode.) 0F
09 External baseblock (N/C) 26
H1-04 Terminal S4 function selection 14 Fault reset 14

8/15
Default
Parameter Value Information Setting
H1-05 Terminal S5 function selection 8D Multi Setpoint 1 8D
H1-06 Terminal S6 function selection 80 Hand Mode 80
H1-07 Terminal S7 function selection 81 Hand Mode 2 81
H1-21 External Fault 1 Delay Time 0,00 sec 0,00 sec
H1-22 External Fault 2 Delay Time 0,00 sec 0,00 sec
H1-23 External Fault 3 Delay Time 0,00 sec 0,00 sec
H1-24 External Fault 4 Delay Time 0,00 sec 0,00 sec
H1-25 External Fault 5 Delay Time 0,00 sec 0,00 sec
H1-26 External Fault 6 Delay Time 0,00 sec 0,00 sec
H1-27 External Fault 7 Delay Time 0,00 sec 0,00 sec

H2-01 Terminal MA/MB-MC Selection 000E Fault 000E


H2-02 Terminal P1 Selection 0037 During frequency output (ON: During frequency output) 0037
H2-03 Terminal P2 Selection 000E Fault 000E
H2-06 Output unit selection 0 0.1kWh unit 0

H3-01 Terminal A1 Signal Level Selection 0 0 to +10 V 0


H3-02 Terminal A1 Function Selection 20 Hand Frequency Reference 20
H3-03 Terminal A1 Gain Setting 100,0 % 100,0 %
H3-04 Terminal A1 Bias Setting 0,0 % 0,0 %
H3-09 Terminal A2 Signal Level Selection 2 4 to 20 mA 2
H3-10 Terminal A2 Function Selection 0B PID Feedback 1 0B
H3-11 Terminal A2 Gain Setting 100,0 % 100,0 %
H3-12 Terminal A2 Bias Setting 0,0 % 0,0 %
H3-13 Filter Avg time 0,03 sec 0,03 sec
H3-14 Terminal Analog Input Selection(when H1-xx 7 Terminal A1 and A2 Enable 7
= C)
H3-16 A1 Offset 0 0
H3-17 A2 Offset 0 0

H4-01 Multi-Function Analog 1(Analog Terminal 102 Output frequency 102


Monitor Selection)
H4-02 Multi-Function Analog 1(Analog Terminal 100,0 % 100,0 %
Output Gain)
H4-03 Multi-Function Analog 1(Analog Terminal 0,0 % 0,0 %
Output Bias)

02 1F
H5-02 Communication speed selection 3 9600 bps 3
H5-03 Communication parity selection 0 No parity 0
H5-04 Serial fault selection 3 Operation continued 3
H5-05 CE Detection Selection 1 Enabled 1
H5-06 Send wait time 5 ms 5 ms
H5-07 RTS control ON/OFF 1 Enabled 1
H5-09 CE detection time 2,0 sec 2,0 sec
H5-10 Output voltage monitor(Register No.25) unit 0 0.1V unit 0
H5-11 ENTER function selection of transmission 0 A constant is reflected and memorized when ENTER is input. 0
H5-12 Run Command Method Selection 0 FWD/STOP,REV/STOP type 0

H6-01 Pulse train input function selection 0 Frequency reference 0


H6-02 Pulse train input scaling 1440 Hz 1440 Hz

9/15
Default
Parameter Value Information Setting
H6-03 Pulse train input gain 100,0 % 100,0 %
H6-04 Pulse train input bias 0,0 % 0,0 %
H6-05 Pulse train input filter time 0,10 sec 0,10 sec
H6-06 Pulse train monitor selection 102 Output frequency 102
H6-07 Pulse train monitor scaling 1440 Hz 1440 Hz
H6-08 Pulse Train Min Input Frequency 0,5 Hz 0,5 Hz

L1-01 Motor protection selection 1 General-purpose motor protection 1


L1-02 Motor protection time constant 1,0 min 1,0 min
L1-03 MOL thermistor input 3 Operation continued 3
L1-04 MOL filter time 1 Coast to stop 1
L1-05 MOL reserved 1 0,20 sec 0,20 sec
L1-13 Electronic thermal continues 1 Enabled 1

L2-01 Momentary power loss detection 2 Enabled while CPU is operating 2


L2-02 Momentary power loss ridethru time 1,0 sec 1,0 sec
L2-03 Min. baseblock time 0,9 sec 0,9 sec
L2-04 Voltage recovery time 0,3 sec 0,3 sec
L2-05 Undervoltage detection level 190 VDC 190 VDC
L2-06 KEB deceleration time 0,0 sec 0,0 sec
L2-07 Momentary recovery time 0,0 sec 0,0 sec
L2-08 KEB Frequency 100 % 100 %
L2-11 Desired DC Bus Voltage during KEB 240 V 240 V

L3-01 StallP acceleration selection 1 Enabled 1


L3-02 StallP acceleration level 120 % 120 %
L3-03 StallP CHP level 50 % 50 %
L3-04 StallP deceleration selection 0 Disabled - The drive decelerates at the selected Dec time.If 0
the load is too large or the Dec time is too short, an OV fault
L3-05 StallP running selection 0 Disabled
may occur. 0
L3-06 StallP running level 120 % 120 %
L3-11 OV Inhibit selection 0 Disable 0
L3-17 Overvoltage Suppression and Deceleration 370 V 370 V
Stall and Desired DC Bus Voltage during
L3-20 Adjustment
Motor Stall Gain 1,00 1,00
L3-21 Deceleration rate operation gain 1,00 1,00
L3-23 StallP running level output auto reduction 0 Sets the stall prevention level throughout the entire frequency 0
range to the value in parameter L3-06.
L3-24 Inertia conversion motor acceleration time 0,265 sec 0,265 sec
L3-25 Load inertia P 1,0 1,0

L4-01 Speed agreement level 0,0 Hz 0,0 Hz


L4-02 Speed agreement width 2,0 Hz 2,0 Hz
L4-03 Speed agreement level +- 0,0 Hz 0,0 Hz
L4-04 Speed agreement width +- 2,0 Hz 2,0 Hz
L4-05 Reference loss selection 0 Stop 0
L4-06 Frequency reference at floss 80,0 % 80,0 %
L4-07 Conditions of Frequency detection 0 No detection during baseblock. 0

L5-01 Number of auto restart attempts 5 time(s) 5 time(s)

10/15
Default
Parameter Value Information Setting
L5-02 Auto restart operation selection 0 Not output(Fault contact is not activated) 0
L5-04 Fault Reset Interval Time 20,0 sec 20,0 sec
L5-40 Low Feedback Fault Retry Selection 0 No retry 0
L5-41 High Feedback Fault Retry Selection 0 No retry 0
L5-42 Feedback Loss Fault Retry Selection 0 No retry 0
L5-50 Setpoint Not Met Fault Retry Selection 0 No retry 0
L5-51 Loss Of Prime Fault Retry Selection 0 No retry 0
L5-52 Pump Over Cycle Fault Retry Selection 0 No retry 0
L5-53 Volute-Thermostat Retry Selection 0 No retry 0

L6-01 Torque detection selection 1 0 Disabled 0


L6-02 Torque detection level 1 15 % 15 %
L6-03 Torque detection time 1 10,0 sec 10,0 sec
L6-04 Torque detection selection 2 0 Disabled 0
L6-05 Torque detection level 2 150 % 150 %
L6-06 Torque detection time 2 0,1 sec 0,1 sec
L6-13 Motor Underload Protection Selection 0 Base Frequency enable 0
L6-14 Motor Underload Protection Level at Min. 15 % 15 %
Frequency

L8-01 DB resistor protect 0 Disabled 0


L8-02 Overheat pre-alarm level 121 deg 121 deg
L8-03 Overheat pre-alarm selection 3 Operation continued(monitor display only) 3
L8-05 Phase loss input selection 1 Enabled 1
L8-07 Phase loss output selection 1 1PH loss detection 1
L8-09 Ground protection selection 1 Enabled 1
L8-10 Cooling fan control selection 0 Operates when inverter is running 0
L8-11 Cooling fan control delay time 300 sec 300 sec
L8-12 Ambient temperature 40 deg 40 deg
L8-15 OL characteristics at low speeds 1 L8-16,17 setting enable 1
L8-18 Software CLA selection 1 Software CLA enable 1
L8-19 Frequency Reduction Rate during OH 0,8 0,8
Pre-Alarm
L8-38 Carrier frequency decel selection 2 Overload career frequency decreases gradually 2
L8-40 Reduction carrier frequency time 0,50 sec 0,50 sec
L8-41 Current warning 0 Disable 0

n1-01 Hunting-prevention selection 1 Enabled 1


n1-02 Hunting-prevention gain 1,00 1,00
n1-03 Hunting-prevention time 10 ms 10 ms
n1-05 Reverse hunting prev gain 0,00 0,00

n3-13 Over exciting deceleration gain 1,10 1,10


n3-21 Over slip inhibit current level 100 % 100 %
n3-23 Over Excitation Run 0 Disable 0

o1-01 Monitor selection 106 Output voltage 106


o1-02 Monitor selection after power up 1 Frequency reference 1
o1-03 Display scaling 0 0.01Hz units 0

11/15
Default
Parameter Value Information Setting
o1-05 LCD Contrast 3 3
o1-06 User Monitor Selection Mode 1 3 Monitor Selectable 1
o1-07 Second Line Monitor Selection 102 Output frequency 102
o1-08 Third Line Monitor Selection 191 191
o1-12 Home Help Text 1 Enabled 1

o2-02 Operation STOP key 1 Always enabled 1


o2-04 KVA selection 6B CIMR-PW2V0040*** 6B
o2-05 Frequency Reference Setting Method 0 Disabled 0
Selection
o2-06 Operator detection 0 Operation continues even if the dig. Operator is disconnected 0
o2-07 Bidirectional when the inverter power is on 0 Forward run 0
o2-09 Initialize mode selection 1 American spec 1
o2-30 Monitor Position Save 0 Disabled 0

o3-02 Copy Allowed Selection 1 Enabled - Copying allowed. 1

o4-02 Cumulative operation time selection 1 Cumulative Inverter run time 1


o4-03 Fan operation time setting 0 1=10H 0 1=10H
o4-05 Capacitor maintenance setting 0% 0%
o4-07 Rush-in prevention relay maintenance setting 0 % 0%
o4-09 IGBT maintenance setting 0% 0%

3 Memobus network 0
P1-02 System Units 1 PSI (Pounds per Square Inch) 1
200,0 PSI 145,0 PSI
-7,0 PSI 0,0 PSI
P1-05 Start Level Delay Time 1 sec 1 sec
30,0 Hz 40,0 Hz
P1-07 Minimum Pump Speed Units 0 Hz 0
15,0 PSI 0,0 PSI
P1-09 Low Feedback Level Fault Delay Time 10 sec 10 sec
P1-10 Low Feedback Selection 0 Fault 0
120,0 PSI 155,0 PSI
P1-12 High Feedback Level Fault Delay Time 5 sec 5 sec
P1-13 High Feedback Selection 0 Fault 0
P1-14 Hysteresis Level 0,0 PSI 0,0 PSI
P1-15 Maximum Set Point Difference 0,0 PSI 0,0 PSI
P1-16 Not Maintaining Setpoint Time 60 sec 60 sec
P1-17 Not Maintaining Setpoint Selection 0 Fault 0
P1-18 Prime Loss Detection Method 0 Current (A) 0
12,0 A 0,0 A
P1-20 Loss of Prime Time 20 sec 20 sec
P1-21 Loss of Prime Frequency 0,0 Hz 0,0 Hz
P1-22 Loss of Prime Selection 0 Fault 0
P1-23 Loss of Prime Maximum Restart Time After 0,2 min 0,2 min
Fault
P1-30 Low Water DI Configuration 0 Normally Open 0
P1-31 High Water DI Configuration 0 Normally Open 0

12/15
Default
Parameter Value Information Setting

P2-01 Sleep Level Type 0 Output Frequency 0


49,0 Hz 0,0 Hz
10 sec 5 sec
P2-04 Sleep Activate Level 0,0 Hz 0,0 Hz
5,0 PSI 0,0 PSI
P2-06 Sleep Boost Hold Time 5,0 sec 5,0 sec
P2-07 Sleep Boost Maximum Time 20,0 sec 20,0 sec
P2-08 Delta Sleep Feedback Drop Level 0,0 PSI 0,0 PSI
P2-09 Feedback Detection Drop Time 10,0 sec 10,0 sec
P2-10 Sleep Mode: Cycling Protection 0 0
P2-11 Sleep Mode: Maximum Cycling Protection 300 sec 300 sec
Time
P2-12 Over Cycling Mode 0 Disabled 0
P2-13 Setpoint Compensation 0,0 PSI 0,0 PSI
P2-14 Maximum Setpoint Compensation 0,0 PSI 0,0 PSI
P2-23 Anti-No-Flow BandWidth 0,40 % 0,40 %
P2-24 Anti-No-Flow Detection Time 10,0 sec 10,0 sec
P2-25 Anti-No-Flow Release Level 3,0 PSI 3,0 PSI

40,0 PSI 0,0 PSI


40,0 Hz 0,0 Hz
1,0 min 0,0 min
P4-05 Pre-Charge Loss Of Prime Level 0,0 A 0,0 A
P4-06 Pre-Charge Frequency 2 0,0 Hz 0,0 Hz
P4-07 Pre-Charge Time 2 0,0 min 0,0 min
P4-08 Pre-Charge Loss Of Prime Level 2 0,0 A 0,0 A
P4-10 AUTO Mode Operator Run Power Down 0 Disabled 0
Storage
P4-11 Thrust Bearing Acceleration Time 1,0 sec 1,0 sec
0,0 Hz 30,0 Hz
P4-13 Thrust Bearing Deceleration Time 5,0 sec 5,0 sec
P4-17 Utility Start Delay 0,2 min 0,2 min
P4-21 Low City Input Select 1 Normally Closed 1
P4-22 Low City On-Delay Time 10 sec 10 sec
P4-23 Low City Off-Delay Time 5 sec 5 sec
P4-24 Low City Water Alarm Text 0 Low City Pressure 0
P4-25 Remote Drive Disable Selection 1 Normally Closed 1
P4-26 Remote Drive Disable On-Delay 0 sec 0 sec
P4-27 Remote Drive Disable Off-Delay 0 sec 0 sec
P4-29 Lube Pump Message 0 Lube Pump 0
P4-30 Lube Pump Active during Run 0 Disabled 0
P4-31 Lube Pump Delay Timer 0,0 sec 0,0 sec
P4-32 Pre-Charge Level 2 0,0 PSI 0,0 PSI

P5-01 Hand Mode Reference Source 1 P5-02 (Hand Reference) 1


60,0 Hz 40,0 Hz
P5-03 Hand/Auto During Run Selection 0 Disabled 0
0 Disabled 1

13/15
Default
Parameter Value Information Setting
P5-05 Hand Reference 2 0,0 Hz 0,0 Hz
P5-06 Hand Ref. 1 Loss Of Prime Level 0,0 A 0,0 A
P5-07 Hand Ref. 2 Loss Of Prime Level 0,0 A 0,0 A
P5-09 HAND References Set via Motor Operated 0 Disabled 0
Pot Selection

P7-01 Anti-jam Selection 0 Disabled 0


P7-02 Anti-Jam Cycle Count 1 1
P7-03 Anti-Jam Detection Current Level 120 % 120 %
P7-04 Anti-Jam Detection Time at Start 0,3 sec 0,3 sec
P7-05 Anti-Jam During Run Current 0% 0%
P7-06 Anti-Jam During Run Time 0,3 sec 0,3 sec
P7-07 Anti-Jam Frequency Reference 25,00 Hz 25,00 Hz
P7-08 Anti-Jam Release Time 2,0 sec 2,0 sec

0 Next Available 1
3 Network Only 0
1 min 24 min
3 LIFO at Sleep 0
P9-05 Lag Mode 0 Fixed Speed 0
59,0 Hz 55,0 Hz
1 sec 5 sec
2 Feedback Level + Output Frequency 0
P9-09 Add Frequency Level 59,5 Hz 59,5 Hz
1,0 PSI 4,0 PSI
1 sec 10 sec
2 Feedback Level + Output Frequency 0
51,0 Hz 40,0 Hz
1,0 PSI 0,0 PSI
6 sec 10 sec
P9-16 Stabilization Time 3 sec 3 sec
P9-17 Setpoint Modifier 0,0 PSI 0,0 PSI
P9-18 High Feedback Quick De-stage 97,0 % 97,0 %
1 Minutes (min) 0
P9-20 Allow Network Run 0 Always 0
P9-21 Run Priority 8 8
P9-22 System Fault Retry 5 5
2 4
P9-24 Lead Swap at Sleep 0 sec 0 sec
2 4
P9-26 Master Time-out 4,0 sec 4,0 sec
P9-27 Network Recovery 0 Automatic 0
P9-28 NETSCAN Alarm Time 2,0 sec 2,0 sec
P9-29 Net Start Delay 2,0 sec 2,0 sec
P9-30 Lag Drive Speed FolLower Gain 100,0 % 100,0 %
P9-31 Lag Drive Speed FolLower Bias 0,00 Hz 0,00 Hz
P9-32 Lag FolLower Deceleration Time 60,0 sec 60,0 sec
P9-33 Lag FolLower Decel. Active Time 0,0 sec 0,0 sec

14/15
Default
Parameter Value Information Setting
P9-34 Low Feedback Quick De-stage 0,0 PSI 0,0 PSI
P9-99 Network Compatibility Selection 2 iQ Smart Network 2

45,0 PSI 0,0 PSI


Q1-02 PID Controller Setpoint 2 0,0 PSI 0,0 PSI
Q1-03 PID Controller Setpoint 3 0,0 PSI 0,0 PSI
Q1-04 PID Controller Setpoint 4 0,0 PSI 0,0 PSI
Q1-09 PID Setpoint Set via Motor Operated Pot 0 Disabled 0

Q3-01 Output Current Limit Select 0 Disabled 0


Q3-02 Current Limit 0,0 A 0,0 A
Q3-10 Single Phase Foldback Selection 1 Enabled 1
Q3-11 Ripple Regulator Setpoint 95,0 % 95,0 %

S6-01 Emergency Override Speed 0,00 Hz 0,00 Hz


S6-02 Emergency Override Reference Selection 0 Use S6-01 Reference 0