0% found this document useful (0 votes)
426 views

AMF9

The document describes an InteliLite controller for single generator applications. It provides key features, technical specifications, and dimensions of the controller. Extension modules are also available to add functionality to the controller.

Uploaded by

Ayadi39
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
426 views

AMF9

The document describes an InteliLite controller for single generator applications. It provides key features, technical specifications, and dimensions of the controller. Extension modules are also available to add functionality to the controller.

Uploaded by

Ayadi39
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

InteliLite

AMF9

Order code: IL-NT AMF 9

Controller for single gen-set applications


Datasheet
Product description
Compact gen-set controller for single gen-set
Application overview
operating in standby mode
Meets all requirements for Auto Mains Failure
(AMF) applications
Full gen-set monitoring and protection

Key features
Outstanding EFI engine support with diagnostic
messages in plain text via J1939
Running hours event and performance log
Plug-in extension modules capability
Supports prime power (MRS) applications
Automatic and manual GCB and MCB control
D+ preexcitation terminal
True RMS measurement
3 phase power measurement of gen-set and mains

| InteliLite NT Datasheet | Related HW ver: 1.6 | Related SW ver: 2.2 | Date of issue: 2019-02-04
Technical data
Power supply Max. measured
9A
current
Power supply
8-36 V DC Max. allowed
range 10 A continuous, 50 A/1 s
current
Power supply
100 ms (from min. 10 V) Current accuracy 2 % from nominal current
drop-out immunity
Power approx. 100 mA / 8 V; 40 mA / 36 Binary inputs
consumption V
Number 4 non-isolated
Peak power
approx. 0,33 A / 8 V; 0,18 A / 36 V Input resistance 4.2 kΩ
consumption (LT)
Common pole Positive, V = 8-36 V DC
Backup battery s
CR 1225
type Close/Open 0-0.8 V close contact

Estimated backup indication 2 - 36 V - V open contact


s
10 years
battery lifetime
Binary outputs
Operating conditions Number 6 non-isolated
Operating Operating voltage 8-36 V DC
-20 ˚C to +70 ˚C
temperature
Switching to Negative supply terminal
Operating
Max current 0.5 A (2 A per group)
temperature (LT -40 ˚C to +70 ˚C
version) Analog inputs
Operating 95 % w/o condensation
Number 3, non-isolated
humidity (IEC/EN 60068-2-30)
Electrical range 0-2500 Ω
Protection degree
IP 65 10 bits, 4 digits
(front panel) Resolution

5-25 Hz, ± 1.6 mm Precision 2 % from measured value


Vibration
25-100 Hz, a = 4 g Predefined: VDO 10Bar, VDO
Shocks a 500 m/s2 Supported sensor Temperature, VDO Fuel level
max
types User-defined: 10 points non-linear
Storage sensors can be defined by the user
-30 ˚C to +80 ˚C
temperature
Communication
Voltage measurement
External modules, 250 kbps, max
Measurement 3 ph-n Gen voltage CAN1
200 m
inputs 3 ph mains voltage

Measurement type True RMS Magnetic pick-up


Voltage range 480 V Ph-Ph (277 V Ph-N) Voltage input
2–70V
range pp
Max. measured
340 V Ph-N
voltage 4 Hz to 10 kHz
Frequency input
Voltage accuracy 2 % from nominal voltage (min 2 V @ 4 Hz, 6 V @ 10
range pp pp
kHz)
Frequency range 30-70 Hz, measured from L3

Frequency Frequency
0.05 Hz 0.2 %
accuracy measurement
tolerance
Current measurement
D+
Measurement
3 ph generator current 250 mA, during the engine start
inputs Excitation current
only
Measurement type True RMS
Charging fail
Current range 5A 80 % of Usupply
threshold

InteliLite NT Datasheet 2
Display
Type Build-in monochromatic
Resolution 128 × 64 px

InteliLite NT Datasheet 3
Dimensions, terminals and mounting

Note: Dimension x depends on plug-in module.

Panel door mounting Overview of parameter x


Plug-in module Parameter x [mm]
IL-NT-AOUT8 75
IL-NT-BIO8 74
IL-NT-RS232 113
IL-NT-RS232-485 115 @ RS232 / 74 @ RS485
IL-NT-GPRS 122
IL-NT-S-USB 128

Note: Parameter x includes reserve for connectors of plug-in modules.

Note: The controller is to be mounted onto the switchboard door. The requested cut-out size is 175x115 mm.
Use the screw holders delivered with the controller to fix the controller into the door.

InteliLite NT Datasheet 4
Available extension modules
Product Description Order code

IL-NT AOUT8 8 analog outputs packed in a unit IL-NT-AOUT8


IL-NT BIO8 8 binary inputs in a unit (HW switchable to 8 binary outputs) IL-NT-BIO8
IL-NT RS232 Communication module which provides additional RS232 interface for controller IL-NT-RS232
IL-NT RS232-485 Communication module which provides additional RS232 and RS485 interface for controller IL-NT-RS232-485
IL-NT GPRS Communication module with integrated GSM modem with GPRS Internet connection IL-NT-GPRS
IL-NT S-USB Communication module which provides additional USB interface for controller IL-NT-S-USB

Related products
Product Description Order code

IL-NT RD (SW) Remote Display Software for InteliLite NT IL-NT RD

Functions and protections


Description ANSI code Descritption ANSI code

Overvoltage 59 Overfrequency 81H

Undervoltage 27 Underfrequency 81L

Gas (Fuel) Level 71 Overload 32

Phase Rotation 47 Overcurrent 50+51

Certificates and standards


EN 61010-1:95 +A1:97

EN 61000-6-3:2006

EN 61000-6-3:2006

EN 61000-6-1:2005

EN 61000-6-2:1999

List of standards is available on: https://webstore.iec.ch/

Manufacturer:
ComAp a.s.
Czech Republic E-mail: [email protected]
Phone: +420 246 012 111 Web: www.comap-control.com

© ComAp. Features and specification are subject to change without prior notice.