0% found this document useful (0 votes)
495 views

LS Inverter Series: Variable Frequency Drive

The document provides information on the LS Variable Frequency Drive series, including models iE5, iC5, iG5A, iS5, iS7, iP5A, and iV5. It lists the key features of simplicity, flexibility, ease of use, and diversity. LS is positioned as a one-stop solution provider for general power transmission applications. Specifications and details are then provided for several of the models.

Uploaded by

Alistair Ciantar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
495 views

LS Inverter Series: Variable Frequency Drive

The document provides information on the LS Variable Frequency Drive series, including models iE5, iC5, iG5A, iS5, iS7, iP5A, and iV5. It lists the key features of simplicity, flexibility, ease of use, and diversity. LS is positioned as a one-stop solution provider for general power transmission applications. Specifications and details are then provided for several of the models.

Uploaded by

Alistair Ciantar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

Variable Frequency Drive

LS Inverter Series
iE5 / iC5 / iG5A / iS5 / iS7 / iP5A / iV5
Simplicity-Precision, Flexibility-Standardization and
Easy to use-Diversity are the inherent qualities of
LS Variable Frequency Drives.
As an one-stop drive solution provider,
LS is ready to offer its own competitive solutions
into the general power transmission industry.

2
Contents
�iE5 4 �iV5 10
�iC5 5 �Comparison 11
�iG5A 6 �Option list 13
�iS5 7 �Dynamic Braking Unit list 14
�iS7 8 �External resistor list 14
�iP5A 9

LS Inverter Series 3
iE5 User friendly micro size slim VFD
1 phase 0.1~0.4kW(0.1~0.5HP), 200~230V
Variable Frequency Drive / Inverter 3 phase 0.1~0.4kW(0.1~0.5HP), 200~230V

● V/f control
● Compact size: 68×128×85mm (2.7×5×3.3 inch)
● 0.1 ~ 200Hz frequency output

● 1 ~ 10kHz carrier frequency

● Fault history: Last 3 faults

● IP20 enclosure

● RS485 (LS Bus / Modbus RTU) communication (Built-in option)

● DC Injection braking

● Selectable manual/automatic torque boost

● Selectable PNP/NPN input signal

● PI control

● Up-Down & 3-Wire operation

● Automatic restart after instantaneous power failure

● Built-in potentiometer

● Monitoring & commissioning PC based software tool (Drive View)

● Parameter copy unit

Model Number
SV 004 iE5 - 1 C

LS inverter brand Motor rating Series name Symbol Input rating Symbol Communication
001: 0.1kW ~ 004: 0.4kW iE5 1 Single-phase, 200~230V None Not available
2 Three-phase, 200~230V C RS485 (LS Bus / Modbus RTU)

General specification
Model number: SV���iE5-� 001-1 002-1 004-1 001-2 002-2 004-2

Motor rating [HP] 0.13 0.25 0.5 0.13 0.25 0.5


[kW] 0.1 0.2 0.4 0.1 0.2 0.4
Output rating Capacity [kVA] 0.3 0.6 0.95 0.3 0.6 1.14
Current [A] 0.8 1.4 2.5 0.8 1.6 3.0
Voltage [V] Three-phase 200 ~ 230V
Frequency [Hz] 0.1 ~ 200Hz
Input rating Voltage [V] Single-phase 200 ~ 230V (±10%) Three-phase 200 ~ 230V (±10%)
Frequency [Hz] 50 ~ 60Hz (±5%)
Current [A] 2.0 3.5 5.5 1.2 2.0 3.5
Weight [kg] 0.44 0.46 1.68 0.43 0.45 0.67

Control Spec Control method V/f, Slip compensation


Speed reference resolution Digital command: 0.01Hz / Analog reference: 0.1Hz (Max freq., 60Hz)
Frequency accuracy Digital command: 0.01% of Max output freq. / Analog signal command of 0.1% of Max output freq.
V/f curve Linear, Squared V/f
Overload capacity 150% for 1 minute
Torque boost Auto & manual torque boost
Operation Keypad Display 4 digit, 7 segment LED
Operation method Keypad / Terminal / Communication
Frequency setting Analog: 0 to 10V / 0 to 20mA / Potentiometer / Digital: Keypad
Operation function PI control / Up-Down operation / 3-Wire operation
Input signal Multi-function terminal PNP / NPN selectable
(P1 ~ P5) 5 points (programmable)
Output signal Multi-function relay Fault output & inverter status output (N.O., N.C.) Less than AC 250V, 0.3A / Less than DC 30V 1A
Analog output 0 to 10Vdc (less than 10mA): frequency / current / voltage / DC voltage selectable

Protection Inverter trip Over voltage / Low voltage / Over current / Ground fault / Inverter overload / Overload trip / Inverter overheat /
Condenser overload / Output phase open / Frequency command loss / Hardware fault / etc.
Inverter alarm Stall prevention

Enclosure IP20
Option Communication, copy unit RS485(LS Bus / Modbus RTU), Parameter copy unit

4
iC5 High torque micro VFD
1 phase 0.4~2.2kW(0.5~3HP), 200~230V
Variable Frequency Drive / Inverter

● EMC filter - class A (Built-in option)


● Selectable V/f, sensorless vector control
● Motor parameter Auto-tuning

● 150% torque at 0.5Hz

● 0.1 ~ 400Hz frequency output

● 1 ~ 15kHz carrier frequency

● 0 ~ 10Vdc analog input

● IP20 enclosure

● Selectable manual/automatic torque boost

● Built-in potentiometer

● Selectable PNP/NPN Input signal

● Fault history: Last 5 faults

● Enhanced process PID control

● Up-Down & 3-Wire operation

● Modbus RTU communication (optional)

● 8 programmable I/O

● Parameter copy unit

● Monitoring & commissioning PC based software tool (Drive View)

Model Number
SV 004 iC5 - 1 F

LS inverter brand Motor rating Series name Symbol Input rating Symbol Filter
004: 0.4kW ~ 022: 2.2kW iC5 1 Single-phase, 200~230V None Not available
F EMC filter

General specification
Model number: SV���iC5-� 004-1 008-1 015-1 022-1
Motor rating [HP] 0.5 1 2 3
[kW] 0.4 0.75 1.5 2.2
Output rating Capacity [kVA] 0.95 1.9 3 4.5
Current [A] 2.5 5 8 12
Voltage [V] Three-phase 200 ~ 230V
Frequency [Hz] 0.1 ~ 400Hz
Input rating Voltage [V] Single-phase 200 ~ 230V (±10%)
Frequency [Hz] 50 ~ 60Hz (±5%)
Current [A] 5.5 9.2 16 21.6
Weight [kg] 0.87 0.89 1.79 1.85

Control Spec Control method V/f, Slip compensation, Sensorless vector


Speed reference resolution Digital command: 0.01Hz / Analog reference: 0.06Hz (Max freq., 60Hz)
Frequency accuracy Digital command: 0.01% of Max output freq. / Analog signal command of 0.1% of Max output freq.
V/f curve Linear, Squared, User custom V/f
Overload capacity 150% for 1 minute, 200% for 30 seconds
Torque boost Auto & manual torque boost
Operation Keypad Display 3 digit, 7 segment LED
Operation method Keypad / Terminal / Communication
Frequency setting Analog: 0 to 10V / 4 to 20mA / Potentiometer / Digital: Keypad
Operation function PID control / Up-Down operation / 3-Wire operation
Input signal Multi-function terminal PNP / NPN selectable
(P1 ~ P5) 5 points (programmable)
Output signal Multi-function relay (N.O., N.C.) Less than AC 250V, 0.3A / Less than DC 30V 1A
Fault output & inverter status output
Multi-function open collector DC24V (less than 50mA)
Analog output 0 to 10Vdc (less than 10mA): frequency / current / voltage / DC voltage selectable

Protection Inverter trip Over voltage / Low voltage / Over current / Ground fault / Inverter overheat / Output phase open / Inverter overload
Overload trip / Communication error / Frequency command loss / Hardware fault / Fan fault / etc.
Inverter alarm Stall prevention, Overload

Enclosure IP20
Option Communication, copy unit Modbus RTU, Parameter copy unit

LS Inverter Series 5
iG5A Powerful & compact sensorless vector control VFD
1 phase 0.4~1.5kW(0.5~2HP), 200~230V
3 phase 0.4~22kW(0.5~30HP), 200~230V
Variable Frequency Drive / Inverter
3 phase 0.4~22kW(0.5~30HP), 380~480V

● Selectable V/f, sensorless vector control ● Built-in Dynamic braking transistor as standard
● Motor parameter Auto-tuning ● Enhanced process PID control
● Powerful torque at overall speed range ● Built-in RS485 (LS Bus / Modbus RTU) communication

● 0.1 ~ 400Hz frequency output ● Cooling fan On/Off control & Easy change

● 1 ~ 15kHz carrier frequency ● Remote control using external keypad * RJ45 cable(Optional)

● -15% ~ +10% input voltage margin ● Upgraded functions: Sleep & Wake-up (Energy savings)

● Fault history: Last 5 faults KEB (Kinetic Energy Buffering) protection


● 0~10Vdc / -10~+10Vdc analog input Low leakage PWM algorism
● IP20 enclosure, UL Type 1 (Option) ●Monitoring & commissioning PC based software tool (Drive View)

● Selectable manual/automatic torque boost ●Footprint EMC Filter (Option)

● Selectable PNP/NPN input signal ●Communication options

● 2nd motor control and parameter setting - DeviceNet, EtherNet, Profibus-DP, CANOpen

Model Number
SV 015 iG5A - 2 FB

LS inverter brand Motor rating Series name Symbol Input rating Symbol Type
004: 0.4kW ~ 220: 22kW iG5A 1 Single-phase, 200 ~ 230V FB Field bus communication
2 Three-phase, 200 ~ 230V EN EMC Filter
4 Three-phase, 380 ~ 480V ENC EMC Filter + Field bus communication
General specification
Model number: SV���iG5A-1� 004 008 015
Motor rating [HP] 0.5 1 2
[kW] 0.4 0.75 1.5
Output rating Capacity [kVA] 0.95 1.9 3.0
Current [A] 2.5 5 8
Voltage [V] Three-phase 200 ~ 230V
Frequency [Hz] 0.1 ~ 400Hz
Input rating Voltage [V] Single-phase 200 ~ 230V (+10%, -15%)
Frequency [Hz] 50 ~ 60Hz (±5%)
Weight [kg] 0.77 1.12 1.84

Model number: SV���iG5A-2� 004 008 015 022 037 040 055 075 110 150 185 220
Motor rating [HP] 0.5 1 2 3 5 5.4 7.5 10 15 20 25 30
[kW] 0.4 0.75 1.5 2.2 3.7 4.0 5.5 7.5 11 15 18.5 22
Output rating Capacity [kVA] 0.95 1.9 3 4.5 6.1 6.5 9.1 12.2 17.5 22.9 28.2 33.5
Current [A] 2.5 5 8 12 16 17 24 32 46 60 74 88
Voltage [V] Three-phase 200 ~ 230V
Frequency [Hz] 0.1 ~ 400Hz
Input rating Voltage [V] Three-phase 200 ~ 230V (+10%, -15%)
Frequency [Hz] 50 ~ 60Hz (±5%)
Weight [kg] 0.76 0.77 1.12 1.84 1.89 1.89 3.66 3.66 9.00 9.00 13.3 13.3

Model number: SV���iG5A-4� 004 008 015 022 037 040 055 075 110 150 185 220
Motor rating [HP] 0.5 1 2 3 5 5.4 7.5 10 15 20 25 30
[kW] 0.4 0.75 1.5 2.2 3.7 4.0 5.5 7.5 11 15 18.5 22
Output rating Capacity [kVA] 0.95 1.9 3 4.5 6.1 6.5 9.1 12.2 18.3 22.9 29.7 34.3
Current [A] 1.25 2.5 4 6 8 9 12 16 24 30 39 45
Voltage [V] Three-phase 380 ~ 480V
Frequency [Hz] 0.1 ~ 400Hz
Input rating Voltage [V] Three-phase 380 ~ 480V (+10%, -15%)
Frequency [Hz] 50 ~ 60Hz (±5%)
Weight [kg] 0.76 0.77 1.12 1.84 1.89 1.89 3.66 3.66 9.00 9.00 13.3 13.3
Control Spec Control method V/f, Slip compensation, Sensorless vector
Speed reference resolution Digital command: 0.01Hz / Analog reference: 0.06Hz (Max freq., 60Hz)
Frequency accuracy Digital command: 0.01% of Max output freq. / Analog signal command of 0.1% of Max output freq.
V/f curve Linear, Squared, User custom V/f
Overload capacity 150% for 1 minute
Torque boost Auto & manual torque boost
Operation Keypad Display 4 digit, 7 segment LED
Operation method Keypad / Terminal / Communication
Frequency setting Analog: 0 to 10V / -10 to 10V / 0 to 20mA / Digital: Keypad
Operation function PID control / Up-Down operation / 3-Wire operation
Input signal Multi-function terminal PNP / NPN selectable
(P1 ~ P8) 8 points (programmable)
Output signal Multi-function relay (N.O., N.C.) Less than AC250V, 0.3A / Less than DC 30V 1A
Fault output & inverter status output
Multi-function open collector DC24V (less than 50mA)
Analog output 0 to 10Vdc (less than 10mA): frequency / current / voltage / DC voltage selectable
Protection Inverter trip Over voltage / Low voltage / Over current / Over Current 2 / Ground fault / Inverter overheat / Output phase open /
OInverter overload / Overload trip / Communication error / Frequency command loss / Hardware fault / Fan fault / Brake error / etc.
Inverter alarm Stall prevention, Overload
Enclosure IP20, NEMA1 (Optional)
Option Cable, conduit kit Remote cable(2M/3M/5M) plus external keypad, Conduit kit for NEMA 1
Communication DeviceNet, EtherNet, CANOpen, Profibus-DP
Others Built-in Dynamic braking transistor, Built-in RS485(LS Bus / Modbus RTU)

6
iS5 Precise vector control standard VFD
3 phase 0.75~55kW(1~75HP), 200~230V
Variable Frequency Drive / Inverter 3 phase 0.75~75kW(1~100HP), 380~480V

● Selectable V/f, Sensorless vector, Sensored vector control (Optional)


● Built-in process PID control
● Optimum acceleration & deceleration for a maximum torque

● APP parameter group for special operations:

Traverse, Multi Motor Control, DRAW


● Multi-function I/O terminal:

Input: 27 functions / Output: 21 functions


● Multi Motor Control (Up to 4 motors: Optional)

● Motor parameter Auto-tuning

● Parameter Read/Write function using a detachable LCD Keypad

● 8 Preset speeds

● Extension I/O boards (Optional): Sub-A, Sub-B, Sub-C

● Communication options:

Modbus RTU, Profibus-DP, DeviceNet, RS485(LS Bus), Fnet(LS PLC link)


● Built-in Dynamic braking transistor (Up to 7.5kW[10HP])

● Monitoring & commissioning PC based software tool (Drive View)

Model Number
SV 008 iS5 - 2 N O , 380V

LS inverter brand Motor rating Series name Symbol Input rating Symbol Loader Symbol UL certification Symbol Rated voltage
008: 0.75kW ~ 750: 75kW iS5 2 Three-phase, 200 ~ 230V None Loader O Open type None 200~230V or 380~480V
4 Three-phase, 380 ~ 480V N Non Loader E Enclosed type 1 **** 380V, 440V, 460V, 480V

General specification
Model number: SV���iS5-2� 008 015 022 037 055 075 110 150 185 220 300 370 450 550
Motor rating [HP] 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75
[kW] 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55
Output rating Capacity [kVA] 1.9 3 4.5 6.1 9.1 12.2 17.5 22.9 28.5 33.5 46 55 68 84
Current [A] 5 8 12 16 24 32 46 60 74 88 122 146 180 220
Voltage [V] Three-phase 200 ~ 230V
Frequency [Hz] 0.1 ~ 400Hz (Sensorless control: 0.1~300Hz, Sensored control: 0.1~120Hz)
Input rating Voltage [V] Three-phase 200 ~ 230V (±10%)
Frequency [Hz] 50 ~ 60Hz (±5%)
Weight [kg] 4.6 4.6 4.8 4.9 7.5 7.7 13.8 14.3 19.4 20.0 42.0 42.0 61 61

Model number: SV���iS5-4� 008 015 022 037 055 075 110 150 185 220 300 370 450 550 750
Motor rating [HP] 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100
[kW] 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Output rating Capacity [kVA] 1.9 3 4.5 6.1 9.1 12.2 17.5 22.9 29.7 34.3 45 56 68 82 100
Current [A] 2.5 4 6 8 12 16 24 30 39 45 61 75 91 110 152
Voltage [V] Three-phase 380 ~ 480V
Frequency [Hz] 0.1 ~ 400Hz (Sensorless control: 0.1~300Hz, Sensored control: 0.1~120Hz)
Input rating Voltage [V] Three-phase 380 ~ 480V (±10%)
Frequency [Hz] 50 ~ 60Hz (±5%)
Weight [kg] 4.7 4.7 4.8 4.9 7.7 7.7 13.9 14.4 20 20 45 45 63 63 68

Control Spec Control method Sensorless vector, Sensored vector, V/f


Speed reference resolution Digital command: 0.01Hz (less than 100Hz),0.1Hz (greater than 100Hz) / Analog reference: 0.03Hz (Max freq., 60Hz)
Frequency accuracy Digital command: 0.01% of Max output freq. / Analog signal command of 0.1% of Max output freq.
V/f curve Linear, Squared, User custom V/f
Overload capacity 150% for 1 minute, 200% for 0.5 second
Torque boost Auto & manual(0 ~ 15%) torque boost
Operation Keypad Display 32 characters LCD keypad / 4 digit, 7 segment LED keypad
Operation method Keypad / Terminal / Communication
Frequency setting Analog: 0 to 10V / 4 to 20mA / Additional port for Sub-board(0~10V) / Digital: Keypad
Operation function DC braking / Frequency limit / Frequency jump / Second function / Second Function / Slip compensation / Reverse rotation prevention / Auto restart / Inverter By-pass
/ Auto-Tuning / PID control
Input signal Sart signal Forward / Reverse
Multi-step Up to 8 speeds can be set (Use Multi-function terminal)
Multi-step Accel/Decel time 0~6,000 sec, Up to 8 types can be set and selected for each setting (Use Multi-function terminal)
Accel/Decel curve : Linear, U curve, S curve
Emergency stop Interrupts the Output from Inverter
JOG JOG operation
Auto operation Operates from Internal sequence by setting Multi-function terminal (5 way * 8 Step)
Fault reset Trip status is removed when Protection function is active
Output signal Operating status Frequency detection level / Overload alarm / Stalling / Over voltage / Low voltage / Inverter overheat / Run / Stop / Constant speed /
Inverter By-pass / Speed search / Auto-operation step / Auto-operation sequence
Fault output Contact output (30A, 30C, 30B) - AC250V 1A, DC30V 1A
Indicator Ouput frequency / Output current / Output voltage(0~10V) / DC voltage / Output torque selectable

Protection Inverter trip Over voltage / Low voltage / Over current 1, 2 / Fuse open / Ground fault / Inverter overheat / Electronic thermal / Output phase open / overload /
External Fault A, B / Over speed / Communication Error / Frequency command loss / Hardware fault / M/C fail / etc
Inverter alarm Stall prevention / Overload / Temperature sensor fault

Enclosure IP20(0.75~7.5kW[1~10HP]), IP00(11~75kW[15~100HP])


Option Board, cable, keypad LCD Keypad, Remote cable(2M/3M/5M), Sub-A board(Extension I/O), Sub-B board(Encoder I/O), Sub-C board(Extension I/O: current input), MMC board
Communication RS485(LS Bus), Modbus RTU, DeviceNet, Profibus-DP, Fnet
Others Built-in Dynamic braking transistor(0.75~7.5kW[1~10HP])

LS Inverter Series 7
iS7 High Torque Performance and Precise VFD
3 phase 200V : 0.75~75kW(1~100HP), 200~230V
Variable Frequency Drive / Inverter 3 phase 400V : 0.75~375kW(1~500HP), 380~480V

● Constant torque / Variable torque dual rating ● 2nd motor sensorless control and parameter setting
● Selectable V/f, V/f PG, sensorless vector, sensored vector ● Available IP54 enclosure(0.75~22kW[1~30HP]) as built-in option
● 150 MIPS(million instructions per second) high speed DSP ● Built-in RS485(LS Bus / Modbus RTU) communication
● High performances & functions: ● Built-in Dynamic braking transistor (0.75~22kW[1~30HP])

Droop control (automatic torque balance) ● Available EMC Filter & DC Reactor as built-in option

KEB (Kinetic Energy Buffering) protection EMC Filter(0.75~22kW[1~30HP]) / DC Reactor(0.75~160kW[1~215HP])


Ride Through (LV Trip Delay) protection ● Wide graphic LCD keypad (6 different languages)

Under Load Trip protection ● PLC board (optional):

PMSM sensorless vector function Master-K platform: 14 max. inputs & 7 max. outputs
Power brake & Flux Brake function ● Extension I/O boards (Optional):

Static motor parameter Auto-tuning* 11 max. inputs & 6 max outputs


● Easy to control: Easy Start Mode, User & Macro group, ● Communication boards (Optional):

Multi Function Key Profibus-DP, DeviceNet, Modbus TCP, Rnet, LonWorks, CANopen
● Monitoring & commissioning PC based software tool (Drive View)

Model Number
SV 0008 iS7 - 2 N O F D W

LS inverter brand Motor rating Series name Symbol Input rating Symbol Loader Symbol UL Certification Symbol Filter Symbol DCR
0008 : 0.75kW ~ 3750 : 375kW iS7 2 Three-phase, 200 ~ 230V Non O Open type None Not available None Not available
N
4 Three-phase, 380 ~ 480V Loader Enclosed Type 1 F EMC filter D DC Reactor
E
Graphic (NEMA1)
S
Loader P NEMA 12
General specification
Symbol Application
Model number: SV���iS7-2� 008 015 022 037 055 075 110 150 185 220 0300 0370 0450 0550 0750 None Normal application
Motor rating [HP] 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 W Web application
[kW] 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Output rating Capacity [kVA] 1.9 3 4.5 6.1 9.1 12.2 17.5 22.9 28.5 33.5 46 57 69 84 116
Current (CT) [A] 5 8 12 16 24 32 46 60 74 88 116 146 180 220 288
Current (VT) [A] 8 12 16 24 32 46 60 74 88 124 146 180 220 288 345
Voltage [V] Three-phase 200 ~ 230V
Frequency [Hz] 0.01 ~ 400Hz (Sensorless-1 control: 0.01~300Hz, Sensorless-2 or Sensored control: 0.01~120Hz)
Input rating Voltage [V] Three-phase 200 ~ 230V (-15% ~ +10%)
Frequency [Hz] 50 ~ 60Hz (±5%)
Current (CT) [A] 8.3 12.9 18.6 24 32.9 41.4 58 69 88 96 121 154 191 233 305
Current (VT) [A] 7 10.6 14.8 21.8 28 42 52 60 75 107 152 190 231 302 326

Model number: SV���iS7-4� 008 015 022 037 055 075 110 150 185 220 300 370 450 550 750 900 1100 1320 1600 1850 2200 2800 3150 3750
Motor rating [HP] 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 120 150 180 225 250 300 375 420 500
[kW] 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 185 220 280 315 375
Output rating Capacity [kVA] 1.9 3 4.5 6.1 9.1 12.2 17.5 22.9 29.7 34.3 46 57 69 84 116 139 170 201 248 286 329 416 467 557
Current (CT) [A] 2.5 4 6 8 12 16 24 30 39 45 61 75 91 110 152 183 223 264 325 370 432 547 613 731
Current (VT) [A] 4 6 8 12 16 24 30 39 45 61 75 91 110 152 183 223 264 325 370 432 547 613 731 877
Voltage [V] Three-phase 380 ~ 480V
Frequency [Hz] 0.01 ~ 400Hz (Sensorless-1 control: 0.01~300Hz, Sensorless-2 or Sensored control: 0.01~120Hz)
Input rating Voltage [V] Three-phase 380 ~ 480V (-15% ~ +10%)
Frequency [Hz] 50 ~ 60Hz (±5%)
Current (CT) [A] 4.3 7.2 10.6 15.4 21 25.8 39 44 57 57 57 69 83 113 154 195 239 286 362 404 466 605 674 798
Current (VT) [A] 3.5 5.3 7.3 10.8 13.8 22.5 26 33 40 52.2 90 109 123 162 195 237 282 350 403 463 590 673 796 948
Control Spec Control method V/f, V/f PG, Slip compensation, Sensorless-1 vector, Sensorless-2 vector, Sensored vector
Speed reference resolution Digital command: 0.01Hz / Analog reference: 0.06Hz (Max freq., 60Hz)
Frequency accuracy Digital command: 0.01% of Max output freq. / Analog signal command of 0.1% of Max output freq.
V/f curve Linear, Squared, User custom V/f
Overload capacity CT(Heavy duty): 150% for 1 minute, VT(Normal duty): 110% for 1 minute
Torque boost Auto & Manual torque boost
Operation Keypad Display Wide graphic LCD keypad (available 6 languages)
Operation method Keypad / Terminal / Communication
Frequency setting Analog: 0 to 10V / -10 to 10V/ 0 to 20mA / Digital: Keypad
Operation function PID control / Up-Down operation / 3-Wire operation / DC braking / Frequency limit / Second function / Slip compensation / Reverse rotation prevention /
Auto restart / Inverter By-pass / Auto-tuning / Flying star / Energy buffering / Power braking / Flux braking / Low leakage / MMC / Easy start
Input signal Multi-function terminal PNP / NPN selectable
(P1 ~ P8) 8 points (programmable)
Output signal Multi-function relay (N.O., N.C.) Less than AC250V, 1A / Less than DC 30V 1A
Fault output & inverter status output
Multi-function open collector DC24V (less than 50mA)
Analog output 0 to 10Vdc (less than 10mA): frequency / current / voltage / DC voltage selectable
Protection Inverter trip Over current / Over voltage / Low current / External trip / Ground fault / Inverter overheat / I/O phase open / Overload / Communication error /
Frequency command loss / Hardware fault / Fan fault / Pre-PID fault / No motor trip / External brake trip / etc.
Inverter alarm Stall prevention / Overload / Light load / Encoder connection error / Keypad command loss /
Speed command loss
Enclosure IP00 (30~75kW, 200V/ 90~375kW, 400V), IP21 (0.75~22kW, 200V / 0.75~75kW, 400V), IP54 / NEMA12 (0.75~22kW, 200V/ 400; Optional)
Option Board, Cable, Keypad Graphic LCD keypad(IP21), Extension I/O, Isolation I/O, Encoder board, PLC board, Remote cable(2M/3M)
Communication Profibus-DP, DeviceNet, Modbus TCP, Rnet, LonWorks, CANopen, EtherNet/IP
Others Built-in Dynamic braking transistor (0.75~22kW[1~30HP]), Built-in RS485(LS Bus / Modbus RTU)
*Available soon

8
iP5A Fan & Pump specialized VFD
3 phase 200V : 0.75~30kW(1~400HP), 200~230V
Variable Frequency Drive / Inverter 3 phase 400V : 0.75~450kW(1~600HP), 380~480V

● Specialized functions for Fan & Pump: Automatic carrier frequency change
Advanced PID control (Pre-PID, Dual PID) ● Selectable V/f, Sensorless vector control
Multi Motor Control function ● Long-life condenser & Simple framework

(Up to 4 motors: 5.5 ~ 90kW[7.5~125HP]) ● Easy Start function


● Energy saving & High efficiency: ● Selectable PNP/NPN input signal

Sleep & Wake-up function ● Plug-in type control terminals

Flying Starting function ● Cooling fan On/Off control

Automatic energy saving function ● Built-in RS485(LS Bus) communication

Flux Braking Algorithm ● Communication boards (Optional):


● Improved protection functions: Modbus RTU, DeviceNet, Profibus-DP, LonWorks,
Pre-heater function BACnet, Modbus TCP*, CANOpen, CC-Link
Low Leakage PWM ● Monitoring & commissioning PC based software tool

Safety stop function (Drive View)


● DNV Certification

Model Number
SV 055 iP5A - 2 N O L (CLASS)

LS inverter brand Motor rating Series name Symbol Input rating Symbol Loader Symbol UL Certification Symbol DCR Symbol Certificate
008 : 0.75kW ~ 4500 : 450kW iP5A 2 Three-phase, 200 ~ 230V None Loader O Open type None Not available (CLASS) DNV
4 Three-phase, 380 ~ 480V N Non Loader E Enclosed Type 1 L DC Reactor
General specification
Model number: SV���iP5A-2� 008 015 022 037 055 075 110 150 185 220 300
Motor rating [HP] 1 2 3 5 7.5 10 15 20 25 30 40
(Fan/Pump) [kW] 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30
Current [A] 5 8 12 16 24 32 46 60 74 88 115
(110% overload) Normal duty: 110% for 1 minute
Motor rating [HP] 0.5 1 2 3 5 7.5 15 15 20 25 30
(General load) [kW] 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22
Current [A] 2.5 5 8 12 17 23 33 44 54 68 84
(150% overload) Heavy duty: 150% for 1 minute
Output rating [kVA] 1.9 3.0 4.6 6.1 9.1 12.2 17.5 22.9 28.2 33.5 43.8
Voltage [V] Three-phase 200 ~ 230V
Frequency [Hz] 0.01 ~ 120Hz
Input rating Voltage [V] Three-phase 200 ~ 230V (-15% ~ +10%)
Frequency [Hz] 50 ~ 60Hz (±5%)
Weight Non DCR type [kg] 4.1 4.2 4.2 4.9 4.9 6 6 13 13.5 20 20

Model number: SV���iP5A-4� 008 015 022 037 055 075 110 150 185 220 300 370 450 550 750 900 1100 1320 1600 2200 2800 3150 3750 4500
Motor rating [HP] 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 175 215 300 350 400 500 600
(Fan/Pump) [kW] 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 220 280 315 375 450
Current [A] 2.5 4 6 8 12 16 24 30 39 45 61 75 91 110 152 183 223 264 325 432 547 613 731 877
(110% overload) Normal duty: 110% for 1 minute
Motor rating [HP] 0.5 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 175 215 300 350 400 500
(General load) [kW] 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 220 280 315 375
Current (Non DCR / DCR) [A] 1.25 2.5 4 6 8.8 12 16 22/24 28/30 34/39 44/45 61 75 91 110 152 183 223 264 325 432 547 613 731
(150% overload) Heavy duty: 150% for 1 minute
Output rating [kVA] 2.0 3.2 4.8 6.4 9.6 12.7 19.1 23.9 31.1 35.9 48.6 59.8 72.5 87.6 121.1 145.8 178 210 259 344 436 488 582 699
Voltage [V] Three-phase 380 ~ 480V
Frequency [Hz] 0.01 ~ 120Hz
Input rating Voltage [V] Three-phase 380 ~ 480V (-15% ~ +10%)
Frequency [Hz] 50 ~ 60Hz (±5%)
Weight Non DCR type [kg] 4.1 4.2 4.2 4.9 4.9 6 6 12.5 13 20 20 27 27 29 42 43 243 280 380
Built-in DCR type [kg] 19.5 19.5 26.5 26.5 39 40 42 67 68 101 101 114 200 200
Control Spec Control method V/f, Slip compensation, Sensorless vector
Speed reference resolution Digital command: 0.01Hz (below 100Hz), 0.1Hz(over 100Hz) / Analog reference: 0.1Hz/60Hz
Frequency accuracy Digital command: 0.01% of Max output freq. / Analog signal command of 0.1% of Max output freq.
V/f curve Linear, Squared, User custom V/f
Overload capacity 110% for 1 minute, 120% for 1 minute(based on ambient 25°C)
Torque boost Auto & Manual(0 ~ 15%) torque boost
Operation Keypad Display 32 characters LCD keypad
Operation method Keypad / Terminal / Communication
Frequency setting Analog: 0 ~ 12V / -12V ~ 12V / 4 ~ 20mA or 0 ~ 20mA / Pulse / Ext - PID / Digital: Keypad
Operation function DC braking / Frequency limit / Frequency jump / Second function / Slip compensation / Reverse rotation prevention / Auto restart / Inverter By-pass / Auto-tuning
/ PID control / Flying star / Safety stop / Flux braking / Low leakage / Pre-PID / Dual-PID / MMC / Easy start / Pre-heater
Input signal Sart signal Forward / Reverse
Multi-step Up to 8 speeds can be set including JOG (Use Programmable Digital Input terminal)
Multi-step Accel/Decel time 0.1~6,000 sec, Up to 4 types can be set (Use Multi-function terminal)
Accel/Decel curve : Linear, U curve, S curve
Emergency stop Interrupts the Output from Inverter
JOG JOG operation
Fault reset Trip status is removed when Protection function is active
Output signal Operating status Frequency detection level / Overload alarm / Stalling / Over voltage / Low voltage / Inverter overheating / Run / Stop / Constant speed /
Inverter By-pass / Speed search
Fault output Contact output (3A, 3C, 3B) - AC250V 1A, DC30V 1A
Indicator Ouput frequency / Output current / Output voltage / DC Link voltage(Output valtage:0~10V)
Protection Inverter trip Over voltage / Low voltage / Over current 1, 2 / Ground fault / Inverter overheating / Electronic thermal / Output phase open / overload /
External Fault A, B / Communication Error / Frequency command loss / Hardware fault / Option fault / etc
Inverter alarm Stall prevention / Overload / Temperature sensor fault
Enclosure IP20/UL type 1(5.5~11kW[7.5~15HP]), IP00/UL open type(15~450kW[20~600HP])
Option Board, cable, keypad LCD Keypad, Remote cable(2M/3M/5M), Sub-E board(Current output)
Communication DeviceNet, Profibus-DP, Modbus TCP, Modbus RTU, Matasys N2, LonWorks, BACnet, CC-Link, CANopen
*Available soon
LS Inverter Series 9
High duty full flux vector control VFD
iV5 3 phase 200V :2.2~37kW(3~50HP), 200~230V
3 phase 400V : 2.2~500kW(1~666HP), 380~480V
Variable Frequency Drive / Inverter DC input type : 5.5~500kW(7.5~666HP)

● Ultimate performance solution for System Drive ● Built-in Dynamic braking transistor (2.2~22kW[3~30HP])
● Advanced Speed & Torque control ● User-friendly LCD keypad (Detachable)
(200% instantaneous torque: Max. 250%) ● Plug-in type control terminals

● Precious Speed & Position synchronization operation ● Extension I/O boards (Optional):

● Static motor parameter Auto-tuning EL I/O (for Elevator application)


● Draw / Droop / Process PID control Encoder division (open collector)
● Highly precious control through optional Sincos Encoder Synchronization option (Speed/Position control)
● Synchronous motor sensorless control Sincos encorder
(SPM & IPM motors) ● Communication boards (Optional)

● Specialized functions for various applications RS485(LS Bus / Modbus RTU)


Load balance function Profibus-DP
Diameter calculation / Taper function DeviceNet
Splicing / Inertia compensation function ● Monitoring & commissioning PC based software tool

Quick stop function (Drive View)

Model Number
SV 022 iV5 - 2 DB (MD) (DC) , 380V

LS inverter brand Motor rating Series name Symbol Input rating Symbol Dynamic Brake Symbol Cover type Symbol Input type Symbol Rated voltage
022: 2.2kW ~ 3750: 370kW iV5 2 Three-phase, 200 ~ 230V None Not available None Metallic cover None AC Input None 200~230V or 380~480V
4 Three-phase, 380 ~ 480V DB Dynamic Braking (MD) Mold cover* (DC) DC Input **** 380V, 460V, 480V*

General specification
Model number: SV���iV5-2� 022 037 055 075 110 150 185 220 300 370
Motor rating [HP] 3 5 7.5 10 15 20 25 30 40 50
[kW] 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37
Output rating Capacity [kVA] 4.5 6.1 9.1 12.2 17.5 22.5 28.2 33.1 46 55
Current [A] 12 16 24 32 46 59 74 88 122 146
Voltage [V] Three-phase 200 ~ 230V
RPM 0 ~ 3600 [RPM]
Input rating Voltage [V] Three-phase 200 ~ 230V (+10%, -10%)
Frequency [Hz] 50 ~ 60Hz (±5%)
Weight Mold cover type [kg] 6 6 7.7 7.7 13.7 13.7 20.3 20.3
Metallic cover type [kg] 14 14 28 28 28 28 42 42

Model number: SV���iV5-4� 022 037 055 075 110 150 185 220 300 370 450 550 750 900 1100 1320 1600 2200 2800 3150 3750 5000
Motor rating [HP] 3 5 7.5 10 15 20 25 30 40 50 60 75 100 120 150 175 215 300 373 420 500 666
[kW] 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 220 280 315 375 500
Output rating Capacity [kVA] 4.5 6.1 9.1 12.2 18.3 22.9 29.7 34.3 46 57 70 85 116 140 170 200 250 329 416 468 557 732
Current [A] 6 8 12 16 24 30 39 45 61 75 91 110 152 183 223 264 325 432 546 614 731 960
Voltage [V] Three-phase 380 ~ 480V
RPM 0 ~ 3600 [RPM]
Input rating Voltage [V] Three-phase 380 ~ 480V (+10%, -10%)
Frequency [Hz] 50 ~ 60Hz (±5%)
Weight Mold cover type [kg] 6 6 7.7 7.7 13.7 13.7 20.3 20.3
Metallic cover type [kg] 14 14 28 28 28 28 42 42 63 63 68 98 98 112 112 175 243 380 380 476

Model number: SV���iV5-4 (DC) 055 075 110 150 185 220 300 370 450 550 750 900 1100 1320 1600 2200 2800 3150 3750 500
Motor rating [HP] 7.5 10 15 20 25 30 40 50 60 75 100 120 150 175 215 300 373 420 500 666
[kW] 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 220 280 315 375 500
Output rating Capacity [kVA] 9.1 12.2 18.3 22.9 29.7 34.3 46 57 70 85 116 140 170 200 250 329 416 468 557 732
Current [A] 12 16 24 30 39 45 61 75 91 110 152 183 223 264 325 432 546 614 731 960
Voltage [V] 380 ~ 480V
RPM 0 ~ 3600 [RPM]
Input rating Voltage [V] DC 540 ~ 680V (+10%,)
Weight [kg] 12 12 24 24.5 25 25 38.5 38.5 50 50 55 79 79 98.5 98.5 154.5 206 343 343 466
Control Spec Control method Sensored Vector (speed sensor)
Speed reference resolution Digital command: 0.1rpm / Analog reference: ±0.0005% of Max output freq.
Speed accurancy Digital command: ±0.01(0~40°C) of Max output freq. / Analog signal reference: ±0.02(25±10°C) of Max output freq.
Cut-off frequency of ASR 50Hz
Torque control accuracy 3%
Accel/Decel time 0.00~6000.0 sec
Accel/Decel combination 4 combinations of Accel/Decel time
Aceel/Decel curve Linear / S curve
Frequency setting Analog: -10 to 10V / 4 to 20mA / Digital: Keypad
Input signal Analog input 3 channels (AI1, AI2, AI3): Extention I/O 2 channels (AI4, AI5)
-10 to 10V / 0 to 10V / 10 to 0V / 4 to 20mA / 20 to 4mA / (AI3, AI5[Extention I/O]: Motor NTC/PTC selectable)
Selectable among 15 diferent Multi-function analog inputs
AI3, AI5: NTC is avaliable only with LG-OTIS motors (both of NTC and PTC are available in case of SV2800iV5~SV3750iV5)
Contact input FX, RX, BX, RST, P1~P7
Selectable among 40 diferent Multi-function analog inputs
Output signal Aanalog output 2 channels (AO1, AO2)
-10 to 10V / 10 to -10V / 0 to 10V / 10 to 0V
Selectable among 40 diferent Multi-function analog outputs
Contact output Multi-function contact output: 2 channels (1A-1B, 2A-2B)
Fault contact output: 1 channel (30A-30C, 30B-30C)
Open collector 1 channel (OC1/EG)
Protection Over voltage / Over current / Low voltage / Inverter overheat / Inverter thermal malfunction / Motor overheat / Motor thermal malfunction /
Overspeed / BX(Instantaneous IGBT gate block) / Fuse open / External fault / Encoder error / Electronic thermal / Overload / IGBT short /
Communication error / etc.
Enclosure IP00 (2.2~22kW[3~30HP]: Mold cover* / 30~374kW[40~500HP]: Metallic cover), IP20 (2.2~22kW[3~30HP]: Metallic cover)
Option Board EL I/O(for Elevator application), Encorder division(open collector), Synchronization option(Speed/Position control), Sincos encorder
Communication RS485(LS Bus / Modbus RTU), Profibus-DP, DeviceNet
*Available soon

10
Comparison
Variable Frequency Drive / Inverter

Model Series iE5 iC5 iG5A iS5


Input Phase Single-phase Three-phase Single-phase Single-phase Three-phase Three-phase
Voltage Range 200~230V 200~230V 200~230V 380~480V 200~230V 380~480V
Motor rating 0.1~0.4kW 0.1~0.4kW 0.4~2.2V 0.4~1.5kW 0.4~22kW 0.4~22kW 0.75~55kW 0.75~75kW
0.13~0.5HP 0.13~0.5HP 0.5~3HP 0.5~2HP 0.5~30HP 0.5~30HP 1~75HP 1~100HP
Constant Torque Standard Standard Standard Standard
Variable Torque
Control method V/f Standard Standard Standard Standard
Sensorless Vector Standard Standard Standard
Sensored Vector Option
Enclosure IP00 Standard Standard
11~22kW 11~75kW
15~30HP 15~100HP
IP20 Standard Standard Standard Standard
0.1~0.4kW 0.4~2.2kW 0.4~22kW 0.75~7.5kW
0.13~0.5HP 0.5~3HP 0.5~30HP 1~10HP
IP21

IP54

UL Type 1 Option
0.4~22kW
0.5~30HP
Keypad Type Fixed type Fixed type Fixed type Detachable type
Built-in 0.1~0.4kW 0.4~2.2kW 0.4~22kW 30~55kW 30~75kW
0.13~0.5HP 0.5~3HP 0.5~30HP 40~75HP 40~100HP
Option 0.75~22kW
1~30HP
Remote cable 2 meters Option Option
3 meters Option Option
5 meters Option Option
Braking transistor Standard Standard
0.4~22kW 0.75~7.5kW
0.5~30HP 1~10HP
EMC Filter Built-in Option Footprint Filter* note 1)
0.4~2.2kW 0.4~4kW
0.5~3HP 0.5~5.4HP
DC Reactor

RS485(LS Bus) Standard Standard Standard* note 2) Option


Modbus RTU Standard Option Standard Standard* note 2) Option
Modbus TCP Option* note 3)
DeviceNet Option* note 4) Option
Profibus-DP Option
Fnet(LS PLC link) Option
Rnet
LonWorks
CANopen Standard* note 3&4)
BACnet
EtherNet/IP Standard* note 3)
CC-Link
MMC(Mulit Motor Control) Option
Encoder Option
Sincos encoder
PLC
Extension I/O Option
Elevator I/O
Synchronization I/O
Note1) SV��� iG5A-4EN-4EN or ENC
Note2) SV��� iG5A-FB and ENC
Note3) SV��� iG5A-FB
Note4) SV��� iG5A-ENC

LS Inverter Series 11
Comparison
Variable Frequency Drive / Inverter

Model Series iS7 iP5A iV5


Input Phase Three-phase Three-phase Three-phase
Voltage Range 200~230V 380~480V 200~230V 380~480V 200~230V 380~480V
Motor rating 0.75~22kW 0.75~375kW 5.5~30kW 5.5~450kW 2.2~37kW 2.2~375kW
1~30HP 1~500HP 7.5~40HP 7.5~600HP 3~50HP 3~666HP
Constant Torque Standard Standard
Variable Torque Standard Standard
Control method V/f Standard Standard
Sensorless Vector Standard Standard
Sensored Vector Option Standard
Enclosure IP00 Standard Standard Standard Standard Standard Standard30~75kW
30~75kW 90~375kW 15~30kW 15~450kW 2.2~22kW 2.2~375kW
40~100HP 125~500HP 20~40HP 20~600HP 3~30HP 3~500HP
IP20 Standard Standard
5.5~11kW 5.5~22kW
7.5~15HP 7.5~30HP
IP21 Standard Standard
0.75~22kW 0.75~75kW
1~30HP 1~100HP
IP54 Built-in Option
0.75~22kW
1~30HP
UL Type 1 Option Standard Standard
0.75~75kW 5.5~11kW 5.5~11kW
1~100HP 7.5~15HP 7.5~15HP
Keypad Type Detachable type Detachable type Detachable type
Built-in 90~160kW 37~450kW 2.2~370kW
125~215HP 50~600HP 3~500HP
Option 0.75~75kW 5.5~30kW
1~100HP 7.5~40HP
Remote cable 2 meters Option Option
3 meters Option Option
5 meters Option
Braking transistor Standard Standard
0.75~22kW 2.2~22kW
1~30HP 3~30HP
EMC Filter Built-in Option
0.75~22kW
1~30HP
DC Reactor Built-in Option Built-in Option Built-in Option
0.75~22kW 0.75~160kW 15~280kW
1~30HP 1~215HP 20~350HP
RS485(LS Bus) Standard Standard / Option Option
Modbus RTU Standard Option Option
Modbus TCP Option Option
DeviceNet Option Option Option
Profibus-DP Option Option Option
Fnet(LS PLC link)
Rnet Option
LonWorks Option Option
CANopen Option
BACnet Option
EtherNet/IP Option
CC-Link Option
MMC(Mulit Motor Control) Standard Standard
Encoder Option Standard
Sincos encoder Option
PLC Option
Extension I/O Option
Elevator I/O Option
Synchronization I/O Option
* Available soon

12
Option list
Variable Frequency Drive / Inverter

Series Option Description


SV-iC5 Modbus RTU iC5 Modbus communication card
iC5
SV-iC5 Copy Unit iC5 Copy Unit
SV-iG5A REMOTE CABLE 2M 2 meter connection cable between inverter and keypad plus fixture
SV-iG5A REMOTE CABLE 3M 3 meter connection cable between inverter and keypad plus fixture
SV-iG5A REMOTE CABLE 5M 5 meter connection cable between inverter and keypad plus fixture
NEMA OPTION 1 (SV004/008iG5A-2/4) Conduit Kit for NEMA 1 (iG5A 0.4~0.75kW)
iG5A Conduit Kit for NEMA 1 (iG5A 1.5kW)
NEMA OPTION 2 (SV015iG5A-2/4)
NEMA OPTION 3 (SV022~040iG5A-2/4) Conduit Kit for NEMA 1 (iG5A 2.2~4kW)
NEMA OPTION 4 (SV055/075iG5A-2/4) Conduit Kit for NEMA 1 (iG5A 5.5~7.5kW)
NEMA OPTION 5 (SV110/150iG5A-2/4) Conduit Kit for NEMA 1 (iG5A 11~15kW)
NEMA OPTION 6 (SV185/220iG5A-2/4) Conduit Kit for NEMA 1 (iG5A 18.5~22kW)
SV-iS5 LCD KEYPAD LCD display keypad for iS5
SV-iS5/iP5A REMOTE CABLE(2M) 2 meter connection cable between inverter and keypad
SV-iS5/iP5A REMOTE CABLE(3M) 3 meter connection cable between inverter and keypad
SV-iS5/iP5A REMOTE CABLE(5M) 5 meter connection cable between inverter and keypad
SV-iS5 SUB BOARD A Extension I/O module, 3 multi-functional inputs and 3 outputs
SV-iS5 SUB BOARD B Encoder pulse input and output module
SV-iS5 SUB BOARD C Extension I/O module, 3 inputs, 1 output and 2 analog meter outputs
iS5
SV-iS5/iP5A SUB BOARD E Current output board (Only available in case that the dedicated O/S is installed)
SV-iS5 MMC Multi Motor Control board
SV-iS5/iH RS485 RS485(LS Bus) communication board
SV-iS5 MODBUS Modbus RTU communication board
SV-iS5/iP5A/iV5 DEVICENET DeviceNet communication board
SV-iS5 F-NET LS PLC link board
SV-iS5/iP5A/iV5 PROFIBUS ProfiBus DP communication board
Graphic LCD display keypad for iS7 (128x64 COG, 11 Rubber Key, 3 LED, IP21)- Multi Languages
SV-iS7 LCD KEYPAD
(English, Italian, Spanish, Russian, Turkish, Arabic) *
SV-iS7 REMOTE CABLE(2M)* 2 meter connection cable between inverter and keypad
SV-iS7 REMOTE CABLE(3M)* 3 meter connection cable between inverter and keypad
SV-iS7 ISOLATION I/O Insulated I/O module, 8 multi-functional inputs and 2 output
SV-iS7 EXTENSION I/O Extension I/O module, 3 multi-functional inputs and 3 output
iS7 SV-iS7 ENCODER Encoder board for closed loop control
SV-iS7 PROFIBUS-DP Profibus-DP communication board
SV-iS7 PLC PLC card (MK120S Platform)
SV-iS7 R-net Rnet communication board
SV-iS7 Modbus TCP 100M BASE-TX, 10M BASE-T support
SV-iS7 DEVICENET DeviceNet Communication board
SV-iS7 LONWORKS LonWork Communication board
SV-iS7 CANopen CanOpen communication board
SV-iP5A LCD KEYPAD LCD display keypad for iP5A
SV-iP5A LonWork Extension LonWorks communication board
SV-iP5A BACNet BACnet communication board
SV-iP5A/iV5 RS485/Modbus-RTU RS485(LS Bus / Modbus RTU) communication board
SV-iS5/iP5A/iV5 DEVICENET DeviceNet communication board
iP5A SV-iS5/iP5A/iV5 PROFIBUS Profibus-DP communication board
SV-iS5/iP5A SUB BOARD E Current output board
SV-iS5/iP5A REMOTE CABLE(2M) 2 meter connection cable between inverter and keypad
SV-iS5/iP5A REMOTE CABLE(3M) 3 meter connection cable between inverter and keypad
SV-iS5/iP5A REMOTE CABLE(5M) 5 meter connection cable between inverter and keypad
SV-iP5A MODBUS TCP* Modbus TCP communication card
SV-iV5 EL I/O I/O interface board for Elevator application
SV-iV5 ENC_DIV(OC) Encoder division board (Open collector)
SV-iV5 SYNC I/O Synchronization operation board (Speed/Positioning control)
iV5 SV-iS5/iP5A/iV5 PROFIBUS Profibus-DP communication board
SV-iS5/iP5A/iV5 DEVICENET DeviceNet communication board
SV-iP5A/iV5 RS485/Modbus-RTU RS485(LS Bus / Modbus RTU) communication board
SV-iV5 Sincos Encoder Sincos encoder signal input board

* Available soon

LS Inverter Series 13
Dynamic Braking Unit list
Variable Frequency Drive / Inverter

Model name Specifications


Dynamic Braking Unit : Based on 150% torque for 100 seconds
SV150DBU-2 Brake unit for 11 to 15kW, 230V / 10%ED
SV220DBU-2 Brake unit for 18.5 to 22kW, 230V / 10%ED

SV037DBH-2(NEW) Brake unit for 30 to 37kW, 230V / 10%ED

SV150DBU-4 Brake unit for 11 to 15kW, 400V / 10%ED


SV220DBU-4 Brake unit for 18.5 to 22kW, 400V / 10%ED

SV037DBH-4(NEW) Brake unit for 30 to 37kW, 400V / 10%ED


SV075DBH-4(NEW) Brake unit for 45 to 75kW, 400V / 10%ED

SV150DBU-2U Brake unit for 11 to 15kW, 230V / 10%ED (UL, cUL listed)
SV220DBU-2U Brake unit for 18.5 to 22kW, 230V / 10%ED (UL, cUL listed)
SV370DBU-2U Brake unit for 30 to 37kW, 230V / 10%ED (UL, cUL listed)
SV550DBU-2U Brake unit for 45 to 55kW, 230V / 10%ED (UL, cUL listed)

SV150DBU-4U Brake unit for 11 to 15kW, 400V / 10%ED (UL, cUL listed)
SV220DBU-4U Brake unit for 18.5 to 22kW, 400V / 10%ED (UL, cUL listed)
SV370DBU-4U Brake unit for 30 to 37kW, 400V / 10%ED (UL, cUL listed)
SV550DBU-4U Brake unit for 45 to 55kW, 400V / 10%ED (UL, cUL listed)
SV750DBU-4U Brake unit for 75kW, 400V / 10%ED (UL, cUL listed)

SV750DB-4* Brake unit for 45 to 75kW, 400V / 100%ED (CE marked )


SV2200DB-4* Brake unit for 160 to 220kW, 400V / 100%ED (CE marked )
* Available soon

External resistor list


Variable Frequency Drive / Inverter

Model name Specifications


External brake resistors : Based on 5% ED (Enable duty)
MCRA 120 W 100 OHM J 120 watt, 100 ohm resistor
MCRA 120 W 50 OHM J 120 watt, 50 ohm resistor
MCRA 120 W 40 OHM J 120 watt, 40 ohm resistor
MCRA 200 W 100 OHM J 200 watt, 100 ohm resistor
MCRA 200 W 160 OHM J 200 watt, 160 ohm resistor
MCRA 200 W 200 OHM J 200 watt, 200 ohm resistor
MCRB 300 W 100 OHM J 300 watt, 100 ohm resistor
MCRB 400 W 200 OHM J 400 watt, 200 ohm resistor
MCRB 400 W 160 OHM J 400 watt, 160 ohm resistor
MCRB 400 W 100 OHM J 400 watt, 100 ohm resistor
MCRB 400 W 50 OHM J 400 watt, 50 ohm resistor
MCRB 400 W 40 OHM J 400 watt, 40 ohm resistor
MCRB-ST 0.6 KW 130 OHM J 600 watt, 130 ohm resistor
MCRB-ST 0.6 KW 33 OHM J 600 watt, 33 ohm resistor
MCRM-ST 0.8 KW 20 OHM J 800 watt, 20 ohm resistor
MCRM-ST 1.0 KW 85 OHM J 1 kW, 85 ohm resistor
MCRM-ST 1.2 KW 60 OHM J 1.2 kW, 60 ohm resistor
MCRM-ST 1.2 KW 15 OHM J 1.2 kW, 15 ohm resistor
MCRM-ST 2.0 KW 40 OHM J 2 kW, 40 ohm resistor
MCRM-ST 2.4 KW 30 OHM J 2.4 kW, 30 ohm resistor
MCRM-ST 2.4 KW 10 OHM J 2.4 kW, 10 ohm resistor
MCRM-ST 2.4 KW 8 OHM J 2.4 kW, 8 ohm resistor
MCRM-ST 3.6 KW 20 OHM J 3.6 kW, 30 ohm resistor
MCRM-ST 3.6 KW 5 OHM J 3.6 kW, 5 ohm resistor

14
Memo
Variable Frequency Drive / Inverter

LS Inverter Series 15
� For your safety, please read user's manual thoroughly before operating.
� Contact the nearest authorized service facility for examination, repair, or adjustment.
� Please contact a qualified service technician when you need maintenance.
Do not disassemble or repair by yourself!
Safety Instructions � Any maintenance and inspection shall be performed by the personnel having expertise concerned.

ⓒ 2003.4 LSIS Co.,Ltd. All rights reserved. www.lsis.biz

� HEAD OFFICE � Global Network


�LSIS (Middle East) FZE �
�Dubai, U.A.E.
Korea Gyeonggi-do Anyang-si dongan-gu Address: LOB 19 JAFZA VIEW TOWER Room 205, Jebel Ali Freezone P.O. Box 114216, Dubai, United Arab Emirates
Tel: 971-4-886 5360 Fax: 971-4-886-5361 e-mail: [email protected]
LS-ro 127 (Hogye-dong) �Dalian LSIS Co., Ltd. �
�Dalian, China
Address: No.15, Liaohexi 3-Road, Economic and Technical Development zone, Dalian 116600, China
Tel: 86-411-8273-7777 Fax: 86-411-8730-7560 e-mail: [email protected]
� Middle East +82-2-2034-4901 / [email protected] �LSIS (Wuxi) Co., Ltd. �
�Wuxi, China
Address: 102-A , National High & New Tech Industrial Development Area, Wuxi, Jiangsu, 214028, P.R.China
� Europe & Africa +82-2-2034-4376 / [email protected] Tel: 86-510-8534-6666 Fax: 86-510-522-4078 e-mail: [email protected]
�LSIS-VINA Co., Ltd. �
�Hanoi, Vietnam
� Asia Pacific +82-2-2034-4645 / [email protected] Address: Nguyen Khe - Dong Anh - Ha Noi - Viet Nam
Tel: 84-4-882-0222 Fax: 84-4-882-0220 e-mail: [email protected]
�LSIS-VINA Co., Ltd. �
�Hochiminh , Vietnam
Address: 41 Nguyen Thi Minh Khai Str. Yoco Bldg 4th Floor, Hochiminh City, Vietnam
Tel: 84-8-3822-7941 Fax: 84-8-3822-7942 e-mail: [email protected]
�LSIS Shanghai Office �
�Shanghai, China
Address: Room E-G, 12th Floor Huamin Empire Plaza, No.726, West Yan'an Road Shanghai 200050, P.R. China
Tel: 86-21-5237-9977 (609) Fax: 89-21-5237-7191 e-mail: [email protected]
�LSIS Beijing Office � �Beijing, China
Address: B-Tower 17FL.Beijing Global Trade Center B/D. No.36, BeiSanHuanDong-Lu, DongCheng-District,
Beijing 100013, P.R. China
Tel: 86-10-5825-6025,7 Fax: 86-10-5825-6026 e-mail: [email protected]
�LSIS Guangzhou Office �
�Guangzhou, China
Address: Room 1403,14F,New Poly Tower,2 Zhongshan Liu Road,Guangzhou, P.R. China
Tel: 86-20-8326-6764 Fax: 86-20-8326-6287 e-mail: [email protected]
�LSIS Chengdu Office �
�Chengdu, China
Address: Room 1701 17Floor, huanminhanjun internationnal Building, No1 Fuxing Road Chengdu, 610041, P.R. China
Tel: 86-28-8670-3101 Fax: 86-28-8670-3203 e-mail: [email protected]
�LSIS Qingdao Office �
�Qingdao, China
Address: 7B40,Haixin Guangchang Shenye Building B, No.9, Shandong Road Qingdao 26600, P.R. China
Tel: 86-532-8501-6568 Fax: 86-532-583-3793 e-mail: [email protected]
�LSIS NETHERLANDS Co.Ltd �
�Qingdao, Netherlands
Address: 1st. Floor, Tupolevlaan 48, 1119NZ,Schiphol-Rijk, The Netherlands
Tel: 31-20-654-1420 Fax: 31-20-654-1429 e-mail: [email protected]
Specifications in this catalog are subject to change without notice due to �LSIS Gurgaon Office �
�Gurgaon ,India
continuous product development and improvement. Address: 109 First Floor, Park Central, Sector-30, Gurgaon- 122 002, Haryana, India

2011. 08 LS Inverter Series(E) 2003.04/(31)2011.08 PrintedinKorea STAFF