0% found this document useful (0 votes)
53 views

Applied Loads Summary: Strength Service

This document summarizes the static load analysis and design of a pile cap foundation supporting a building. It provides the applied loads, dimensions of the pile cap, and details of the two circular piles. It analyzes the pile capacity in compression and bending. It also analyzes the pile cap for shear capacity in two directions, punching shear, pile pair punching shear, and one-way shear of Pile 1. The analyses show the pile cap and piles meet the required strength and service criteria.

Uploaded by

Ahmad Imanuddin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as RTF, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
53 views

Applied Loads Summary: Strength Service

This document summarizes the static load analysis and design of a pile cap foundation supporting a building. It provides the applied loads, dimensions of the pile cap, and details of the two circular piles. It analyzes the pile capacity in compression and bending. It also analyzes the pile cap for shear capacity in two directions, punching shear, pile pair punching shear, and one-way shear of Pile 1. The analyses show the pile cap and piles meet the required strength and service criteria.

Uploaded by

Ahmad Imanuddin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as RTF, PDF, TXT or read online on Scribd
You are on page 1/ 2

PC 3

Static
Applied Loads Summary
Strength Service
Analysis 3D Building Analysis 3D Building Analysis
Combination 4 (Erection) Cb1.1-1.4D+1.6I+1.6RI+NHFDir1+ 4 (Erection) Cb1.1-1.4D+1.6I+1.6RI+NHFDir1+
P 1335.1 kN 953.7 kN
Fx,sup -6.7 kN -4.8 kN
Fy,sup 0.0 kN 0.0 kN
Mx,sup 0.0 kNm 0.0 kNm
My,sup -10.0 kNm -7.1 kNm
Added Loads
Fswt 11.5 kN
Fsoil 0.0 kN
FGsur 0.0 kN
FQsur 0.0 kN

Foundation Details
Foundation Type Pile Cap
Concrete Class C25
Size 1300mm × 550mm
Overall Depth 700.0 mm
Top Cover 40.0 mm
Bottom Cover 40.0 mm
Side Cover 40.0 mm
Depth From Surface 0.0 mm
Number of Piles 2
Pile Shape and Size Circular 250 mm
Pile Installation Type Driven
Pile Length 20.000 m
Pile Edge Distance 150.0 mm
Pile Embedment 100.0 mm

Pile Capacity - Critical


Summary
Compression Tension
Analysis 3D Building Analysis -
Combination 4 (Erection) Cb1.1-1.4D+1.6I+1.6RI+NHFDir1+ -
Fpn,max 496.6 kN -
R 500.0 kN -
Ratio 0.993 -

Bending Capacity
Summary
Direction X Y
Analysis 3D Building Analysis 3D Building Analysis
Combination 3 (Erection) Cb1-1.4D+1.6I+1.6RI 4 (Erection) Cb1.1-1.4D+1.6I+1.6RI+NHFDir1+
mu 77.026 kNm/m 359.166 kNm/m
d 630.0 mm 650.0 mm
K / K' 0.050 0.218
z 598.5 mm 617.5 mm
As,reqd,bot 322 mm2/m 1453 mm2/m
As,prov,bot 1047 mm2/m 1795 mm2/m
As,min,bot 1033 mm2/m 1033 mm2/m
Ratio 0.307 0.810
Top - -
Bottom Type 2 T 20 @ 300.0-B2 Type 2 T 20 @ 175.0-B1

Shear Capacity
Summary
Direction X Y
Analysis 3D Building Analysis 3D Building Analysis
Combination 4 (Erection) Cb1.1-1.4D+1.6I+1.6RI+NHFDir1+ 3 (Erection) Cb1-1.4D+1.6I+1.6RI
vsu 1.922 N/mm2 0.000 N/mm2
vres 3.446 N/mm2 0.000 N/mm2
Ratio 0.558 0.000

Pile Punching Shear


Summary
Perimeter u0 / un vef vmax / vc Ratio Status
[mm] [N/mm2] [N/mm2]
Loaded - - - - Not required

Pile Pair Punching Shear


Check Not Required
Check is not required for any pile pair

Pile One-Way Shear


Summary : Pile 1
vsu vmax vres Ratio Status
[N/mm2] [N/mm2] [N/mm2]
2.424 4.000 3.014 0.804
Pass