CD2000 Parameters
CD2000 Parameters
Function Factory
Illustration Setting Range Minimum
Code Default
Unit
0:Panel control
Control channel 1:Terminal control
F0.00 1 0
selection 2:Communication
control
0: Two-wire 1
Terminal control 1: Two-wire 2
F0.01 1 0
mode 2: Three-wire 1
3: Three-wire 2
0:Digital setting for
UP,DOWN
adjustment
1:AI1
Selection of 2:AI2
F0.02 main frequency 1 0
3:PULSE setting (X6)
source A
4: Multi-speed
5:PLC
6:PID
7:Communication
setting
0:Digital setting for
UP,DOWN
adjustment
Selection of
auxiliary 1:AI1
F0.03 1 1
frequency
source B 2:AI2
6:PID
7: Communication
setting
Range selection
0: Relative to
of auxiliary
F0.04 1 0
frequency maximum frequency
source B 1: Relative to
frequency source A
Range of 1% 100%
auxiliary
F0.05 0~100%
frequency
source B
0:Main frequency
source A
1: Main frequency
source A + auxiliary
frequency source B
2: Switch main
Frequency frequency source A
F0.06 1 0
source selection
and auxiliary
frequency source B
3: Switch main
frequency source A
and main frequency
source A + auxiliary
frequency source B
0:Non-memory
Digital setting
F0.07 for memory 1 1
1:Shutdown memory
selection
2:Shutdown,power-off
memory
Lower frequency limit
F0.08 Preset frequency – Upper limiting 0.01Hz 50.00Hz
frequency
Maximum
F0.09 50.00 - 300.0HZ 0.01Hz 50.00Hz
frequency
Upper limiting Lower frequency limit
F0.10 0.01Hz 50.00Hz
frequency - Maximum frequency
Lower 0.00Hz - Upper
F0.11 0.01Hz 00.00Hz
frequency limit limiting frequency
0:Positive direction
Running
F0.12 1 0
direction
1:Negative direction
0.00 - Maximum
Inching
F1.00 0.01Hz 5.00Hz
frequency frequency(F0.09)
Inching
F1.01 acceleration 0.0s – 3200.0s 0.1s 1.0s
time
Inching
F1.02 deceleration 0.0s - 3200.0s 0.1s 1.0s
time
0.00hz –Maximum
Hopping
F1.03 0.01Hz 0.00Hz
frequency frequency(F0.09)
Range of 0.00hz –Maximum
F1.04 hopping 0.01Hz 0.00Hz
frequency(F0.09)
frequency
Positive and
F1.05 negative 0.0s – 200.0s 0.1s 0.0s
dead-zone time
Acceleration
F1.06 0.0s - 3200.0s 0.1s 20.0s
time 1
Deceleration
F1.07 0.0s - 3200.0s 0.1s 20.0s
time 1
Acceleration
F1.08 0.0s - 3200.0s 0.1s 20.0s
time 2
Deceleration
F1.09 0.0s - 3200.0s 0.1s 20.0s
time 2
Acceleration and 0: Straight-line
F1.10 1 0
deceleration acceleration and
mode selection deceleration
1: S curve
acceleration and
deceleration
S curve start
F1.11 0.0 - 40.0% 0.1% 30.0%
time
F1.12 S curve end time 0.0 - 40.0% 0.1% 30.0%
0: Permit reversal
F1.13 Reversal control 1 0
1: Inhibit reversal
0:Direct start
F2.00 Starting mode 1 0
1 : Speed tracking
mode
0:Slowdown
F2.05 Stop mode 1 0
1:Stop immediately
0: Running at lower
frequency limit
Below lower
F2.06 1 0
frequency limit 1 : Stop after Delay
stop time(F2.07)
F2.07 Delay stop time 0.0s – 600.0s 0.1s 300.0s
DC brake
0.00hz –Maximum
F2.08 frequency when 0.01Hz 0.00Hz
frequency
machine halts
DC brake
electric current
F2.09 0% - 100% 1% 0%
when machine
halts
DC brake
waiting time
F2.10 0.0s – 600.0s 0.1s 0.0s
when
machine halts
DC brake
waiting time
F2.11 0.0s – 600.0s 0.1s 0.0s
when
machine halts
F2.12 Brake usage rate 0% - 100% 1% 50%
F2.13 reserved
F2.14 reserved
F2.15 reserved
F2.16 reserved
0 :Invalid
Water supply
F2.17 1 0
sleep function
1 :Valid
Water supply
wakeup delay
F2.18 0.0s – 600.0s 0.1s 1.0s
time from
sleeping
Duration of start
F2-19 0.0s – 600.0s 0.1s 0.0s
DC braking
0:No function
1:Forward running
2: Reversal running
3: Three-wire mode
4::Terminal UP
5:Terminal down
6:Forward inching
7:Reversal inching
8:Multi-speed
terminal 1
9:Multi-speed
terminal 2
10:Multi-speed
terminal 3
11:Pause running
F3.00 X1 1 0
12:Stop immediately
13:Fault reset
terminal
14:reserved
15 : generating
external fault
when terminal is
closed
16:Remote command
and keyboard
command switch
1
17: Communication
and terminal
command switch
2
F3.01 X2 1 0
18 : Frequency
F3.02 X3 1 0
F3.03 X4 source switches 1 0
F3.04 X5 terminal, refer to 1 0
F3.05 X6 function 1 0
F3.06 description of 1 1
F3.07 reserved F0.06 1 2
F3.08 1 0
19:Clear UP/DOWN
settings
21:PID pauses
23: Reserved
24:Reserved
25:Reserved
26:Reserved
27:Reserved
11:Special processing
12 : Ready for
operation
13: Reserved
14 : Pre-alarm for
Collector Y2 motor
F4.03 output function overloading 1 0
selection 15 : Communication
setting
16 : Frequency
reaching the FDT
value
17:Reserved
18:Reserved
Relay 1 output
F4.04 0.0s – 300.0s 0.1 0.0s
time delays
Relay 2 output
F4.05 0.0s – 300.0s 0.1 0.0s
time delays
Collector Y1
F4.06 output time 0.0s – 300.0s 0.1 0.0s
delays
Collector Y2
F4.07 output time 0.0s – 300.0s 0.1 0.0s
delays
AO1 output
F4.08 0:Running frequency 1 0
selection
AO2 output
F4.09 1:Frequency setting 1 0
selection
2:current(0 – 2times
rated current of
Motor)
3:Output voltage of
frequency
converter , 0 ~
1.2times rated
voltage of
DO(FM) output frequency
F4.10 1 0
selection converter)
4:AI1 Voltage output
6:Reserved
7:Reserved
8:PULSE input
9:Communication set
F4.11 AO1 Gain -10.00 – 10.00 0.01 1.00
AO1 offset
F4.12 -100.0% - 100.0% 0.1% 0.0%
coefficient
F4.13 AO2 Gain -10.00 – 10.00 0.01 1.00
AO2 offset
F4.14 -100.0% - 100.0% 0.1% 0.0%
coefficient
Maximum
F4.15 frequency D0 0.1khz – 50.0khz 0.1kHz 50.0kHz
PULSE outputs
Frequency
0.00hz –Maximum
F5.00 detected value 0.01Hz 50.00Hz
frequency
(FDT)
Frequency
F5.01 detection (FDT) 0.0% - 100.0% 0.1% 5.0%
drop value
Detection rate
0.0% - 100.0%
F5.02 when frequency 0.1% 0.0%
arrives Maximum frequency
Proportion
coefficient when
F5.03 0.000 - 1.5000 0.001 1.000
displaying
rotating speed
Total run time
F5.04 0 - 9999 1 0
record
Display
0 - 9999(refer to
F5.05 parameters of 1 21
schedule)
LED running
Display
0 - 9999(refer to
F5.06 parameters when 1 3
schedule)
LED is
shutdown
0:Invalid
1:Switch of keyboard
and remote
Function
control
selection of
F5.07 1 0
multi-function 2: Switch of positive
key (JOG)
and negative running
3:Forward inching
4:Reversal inching
STOP/RES key
F5.08 0:Valid only under 1 0
function
the control of
keyboard
1: Valid under the
control of other
control mode
F5.09 Software version 0.1 - 999.9 0.1 Factory set
Frequency
F5.10 0 – 100 1 Factory set
converter
temperature
0 : Digital setting
( F6.01 ) (up/down
adjustable)
1:AI1 setting
Multi-speed
F6.00 ZERO given 2:AI2 setting 1 0
mode
3:PULSE setting
4:PID setting
5 : Communication
setting
-100.0% - 100.0%
( 100%
F6.01 Multi-speed 0 corresponding to 0.1% 0.0%
maximum frequency
F0.09)
-100.0% - 100.0%
( 100%
F6.02 Multi-speed 1 corresponding to 0.1% 0.0%
maximum frequency
F0.09)
F6.03 Multi-speed 2 -100.0% - 100.0% 0.1% 0.0%
( 100%
corresponding to
maximum frequency
F0.09)
-100.0%-100.0%
( 100%
F6.04 Multi-speed 3 corresponding to 0.1% 0.0%
maximum frequency
F0.09)
-100.0% - 100.0%
( 100%
F6.05 Multi-speed 4 corresponding to 0.1% 0.0%
maximum frequency
F0.09)
-100.0% - 100.0%
( 100%
F6.06 Multi-speed 5 corresponding to 0.1% 0.0%
maximum frequency
F0.09)
-100.0% - 100.0%
( 100%
F6.07 Multi-speed 6 corresponding to 0.1% 0.0%
maximum frequency
F0.09)
-100.0% - 100.0%
( 100%
F6.08 Multi-speed 7 corresponding to 0.1% 0.0%
maximum
frequencyF0.09)
0 : Power down
PLC power-fail
without memory
F6.10 memory 1 0
selection 1:Power down with
memory
0:Minute
PLC run time
F6.11 1 0
unit
1:Hour
Run time of
F6.12 0.0m(h) - 999.9 m(h) 0.1m(h) 0.0m(h)
PLC 0 section
0 : acceleration and
deceleration time 1
1 : acceleration and
Acceleration and
deceleration deceleration time 2
F6.13 1 0
time selection of
2 : acceleration and
PLC 0 section
deceleration time 3
3 : acceleration and
deceleration time 4
Runtime of PLC
F6.14 0.0m(h) - 999.9 m(h) 0.1m(h) 0.0m(h)
first section
0 : acceleration and
deceleration time 1
1 : acceleration and
Acceleration and
deceleration deceleration time 2
F6.15 1 0
time selection of
2 : acceleration and
PLC first section
deceleration time 3
3 : acceleration and
deceleration time 4
Run time of
F6.16 PLC second 0.0m(h) - 999.9 m(h) 0.1m(h) 0.0m(h)
section
0 : acceleration and
deceleration time 1
Acceleration and 1 : acceleration and
deceleration
deceleration time 2
F6.17 time selection of 1 0
PLC second 2 : acceleration and
section
deceleration time 3
3 : acceleration and
deceleration time 4
Run time of
F6.18 PLC third 0.0m(h) - 999.9 m(h) 0.1m(h) 0.0m(h)
section
0 : acceleration and
deceleration time 1
Acceleration and 1 : acceleration and
deceleration
deceleration time 2
F6.19 time selection of 1 0
PLC third 2 : acceleration and
section
deceleration time 3
3 : acceleration and
deceleration time 4
Run time of
F6.20 PLC fourth 0.0m(h) - 999.9 m(h) 0.1 m(h) 0.0m(h)
section
0 : acceleration and
deceleration time 1
Acceleration and
1 : acceleration and
deceleration
F6.21 time selection of deceleration time 2 1 0
PLC fourth
2 : acceleration and
section
deceleration time 3
3 : acceleration and
deceleration time 4
Run time of
F6.22 PLC fifth 0.0m(h) - 999.9 m(h) 0.1m(h) 0.0m(h)
section
0 : acceleration and
deceleration time 1
Acceleration and 1 : acceleration and
deceleration
deceleration time 2
F6.23 time selection of 1 0
PLC fifth 2 : acceleration and
section
deceleration time 3
3 : acceleration and
deceleration time 4
Run time of
F6.24 PLC sixth 0.0m(h) - 999.9 0.1m(h) 0.0m(h)
section
0 : acceleration and
deceleration time 1
Acceleration and 1 : acceleration and
deceleration
deceleration time 2
F6.25 time selection of 1 0
PLC sixth 2 : acceleration and
section
deceleration time 3
3 : acceleration and
deceleration time 4
Run time of
F6.26 PLC seventh 0.0m(h) - 999.9 m(h) 0.1m(h) 0.0m(h)
section
0 : acceleration and
Acceleration and deceleration time 1
deceleration
1 : acceleration and
F6.27 time selection of 1 0
PLC seventh deceleration time 2
section
2 : acceleration and
deceleration time 3
3 : acceleration and
deceleration time 4
0:F7.01
1:AI1
2:AI2
PID given
F7.00 0 0
source 3:PULSE
4:Multi-speed
5 : Communication
setting
PID value
F7.01 0.0% - 100.0% 0.1% 50.0%
setting
0:AI1
PID feedback
F7.02 1:AI2 1 0
source
2:PULSE
0:Positive function
PID function
F7.03 1 1
direction
1:Negative function
PID feedback
F7.04 0 - 9999 1 1000
measuring range
Proportional
F7.05 0.1 - 100.0 0.1 20.0
gain P
Integral
F7.06 00.00s – 10.00s 0.01 2.00s
coefficient I
Derivation time
F7.07 00.00s – 10.00s 0.001s 00.00s
D
F7.08 Deviation limit 0.0% - 100.0% 0.1% 0.5%
0: None check(N,8,
2)
1: Even check(E,8,
F8.02 Data format 1 0
1)
2: Odd check(O,8,
1)
Communication
F8.03 0ms~20ms 1ms 10ms
response delay
Communications
F8.04 timeout fault 0.0s ~ 100.0s 0.1s 10.0s
time
2 : Multi-point V/F
curve
F9.05 Torque upgrade 0.0%- 30.0% 0.1% 5.0%
Torque upgrades
0.00HZ – Maximum
F9.06 and cutoff 0.01hz 30.00HZ
frequency
frequency
Slip
F9.07 compensation 0.0% - 200.0% 0.1% 0.0%
factor
Over excitation
F9.08 0 - 200 1 30
gain
0:G model
F9.09 Motor model 1 0
1:P model
Oscillation
F9.10 0 - 100 1 0
suppression gain
Carrier
F9.11 0.5khz–16.0khz 0.1 4kHZ
frequency
Multipoint v/f
F9.12 frequency point F9.14- F0.09 0.01hz 0.00Hz
f3
Multipoint v/f
F9.13 F9.15 - 100.0% 0.1% 0.0%
voltage point v3
Multipoint v/f
F9.14 frequency point F9.16 - F9.12 0.01Hz 0.00Hz
f2
Multipoint v/f
F9.15 F9.17 - F9.13 0.1% 0.0%
voltage point v2
Multipoint v/f
F9.16 frequency point 0 –F9.14 0.01Hz 0.00Hz
f1
Multipoint v/f
F9.17 0.0% - F9.15 0.1% 0.0%
voltage point v1
0:Disable
Over-current
1 : Valid only when running at
FA.10 speed protection 1 2
select constant speed
2:Valid all the time
Over-current
FA.11 speed protection 50% - 200% 1% 150%
current level
Over-current
speed
FA.12 1.0-600.0s 0.1s 10.s
deceleration
time
0:Invalid
FA.13 AVR select 1 1
1:Valid all the time
2:Valid only when the speed is
decreasing
0:Invalid
Output lacking
FA.14 0 1
phase protection
1:Valid
FA.15 Reservation 0 0 0
The former
FA.16
second fault type
The former first
FA.17
fault type
The last fault
FA.18
type
Frequency when
FA.19
error occurs
Electric current
FA.20 when fault
occurs
DC bus voltage
FA.21
when fault
occurs
Input terminal
FA.22 state when fault
occurs
Output state
FA.23 when fault
occurs
FB Group Reserved
FC Group added parameters
Acceleration
FC.00 0.0s – 3200.0s 0.1s 10.0s
time 3
Deceleration
FC.01 0.0s – 3200.0s 0.1s 10.0s
time3
Acceleration
FC.02 0.0s – 3200.0s 0.1s 10.0s
time 3
Deceleration
FC.03 0.0s – 3200.0s 0.1s 10.0s
time3
FD Group
FD.00 password 0 - 9999 1 0
FD.01 Set run time 0 - 9999 1 0
0:Hour
FD.02 Set run time unit 1 0
1:Minute
0:No operation
FE.01
1:Restore the factory parameters 1 0