Aspen Exchanger Design and Rating Fired Heater V11

This document provides specifications for a fired heater with a box firebox and horizontal and roof tubes. It will absorb a total duty of 7617.2 kW while heating a hydrocarbon process fluid from 25°C to 235°C. The process fluid will flow at 29856 kg/h with allowable and calculated pressure drops of 2990 kPa and 0 kPa respectively. Key operating parameters and inlet and outlet conditions are presented.

Uploaded by

Marco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
97 views

Aspen Exchanger Design and Rating Fired Heater V11

This document provides specifications for a fired heater with a box firebox and horizontal and roof tubes. It will absorb a total duty of 7617.2 kW while heating a hydrocarbon process fluid from 25°C to 235°C. The process fluid will flow at 29856 kg/h with allowable and calculated pressure drops of 2990 kPa and 0 kPa respectively. Key operating parameters and inlet and outlet conditions are presented.

Uploaded by

Marco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Aspen Exchanger Design and Rating Fired Heater V11

File: C:\Users\Hafidz Aliyufa\Documents\ALIYUFA\..\QFiredHeater7.EDR Printed: 11/7/2019 at 7:32:59 PM

API Process

Fired Heater Heat Exchanger Specification Sheet


1 Standard example: QFiredHeater7
2 Box firebox, horizontal wall tubes + roof tubes. Process fluid: Bjac hydrocarbon
3 Service of Unit: Our Reference:
4 Total absorbed duty kW 7617.2
5 PROCESS DESIGN CONDITIONS
6 Heater section Firebox Bank 1 Bank 2 Bank 3 Bank 4
7 Heat absorption kW 7617.2
8 Fluid 1
9 Flow rate kg/h 29856
10 Pressure drop, allowable kPa 2990
11 Pressure drop, calculated kPa 0
12 Avg. rad. sect. flux density, calc. kW/m² 11.4
13 Max. rad. sect. flux density kW/m² 19.3
14 Conv. sect. flux density (bare tube) kW/m²
15 Process fluid mass velocity kg/s/m² 37.08
16 Max. calc. inside film temperature °C 250
17 Fouling factor (tube-side) m²-K/W 0
18 INLET CONDITIONS:
19 Temperature °C 25
20 Pressure kPa 3000
21 Vapor mass fraction - 0
22 Liquid flow kg/h 29856
23 Vapor flow kg/h 0
24 Liquid density kg/m³ 1008.2
25 Vapor density kg/m³
26 Liquid viscosity cp 0.8904
27 Vapor viscosity cp
28 Liquid specific heat kJ/(kg-K) 4.31
29 Vapor specific heat kJ/(kg-K)
30 Liquid thermal conductivity W/(m-K) 0.611
31 Vapor thermal conductivity W/(m-K)
32 OUTLET CONDITIONS:
33 Temperature °C 235
34 Pressure kPa 3000
35 Vapor mass fraction - 0
36 Liquid flow kg/h 29856
37 Vapor flow kg/h 0
38 Liquid density kg/m³ 836.39
39 Vapor density kg/m³
40 Liquid viscosity cp 0.0699
41 Vapor viscosity cp
42 Liquid specific heat kJ/(kg-K) 4.717
43 Vapor specific heat kJ/(kg-K)
44 Liquid thermal conductivity W/(m-K) 0.7329
45 Vapor thermal conductivity W/(m-K)
46 REMARKS AND SPECIAL REQUIREMENTS:
47
48
49