Phillips Vessel Book
Phillips Vessel Book
Capabilities
Facility
In 2011 Phillips built and moved into a brand new facility located in DeKalb, IL. Due to extremely high demand, an addition was
built in 2012, which brings our total manufacturing space to 25,000 square feet. Phillips continues to grow to meet customer
demand.
Welding Quality
H.A. Phillips & Co.’s welding fabrication processes are second-to-none in industrial refrigeration. All of our welders are ASME
certified and have completed rigorous training. We maintain several sub-arc welding stations, which allow for greater production
efficiency and consistency. Our welders are skilled in MIG, TIG, stick, flux-core and sub-arc welding processes. We are equally
proficient in welding carbon steel as well as stainless steel. In February 2013 we installed a new CNC controlled pipe cutting
machine for cutting nozzle holes into shells.
ASME Certification
H.A. Phillips & Co. holds an ASME ‘U’ stamp and a National Board ‘R’ stamp. Our Quality Management System and welders are
certified in accordance with the ASME Code Section VIII, Division 1. Every welder certification test is evaluated in accordance
with Section IX of the ASME code by an outside authority. Furthermore, all ASME Code work is inspected by an independent
agency prior to applying the U-stamp of approval.
ISO 9001 Certification
H.A. Phillips & Co. has been ISO certified since 2000. We are currently certified to ISO 9001:2015. The organization of
H.A. Phillips & Co. is committed to being a preeminent global manufacturer of high quality welded, machined, electrical and
electronically controlled products.
Pump Recirculation Packages
Phillips mechanical pump recirculation packages are available up to 144” diameter. Each pump recirculation package is custom
designed and packages come standard with Phillips check valves and Danfoss hand valves. While Phillips and Danfoss valve
options provide the most economical design, we can package with any valve brand per the customer’s preference. We also
package with customer’s choice of Nikkiso, Teikoku or Cornell pumps.
Plate & Frame Chiller Packages
Factory-packaged plate and frame heat exchangers with surge drums, columns, oil pots and liquid makeup valve trains are
available. We can provide the complete skid-mounted turnkey package with customer’s choice of plate heat exchangers, or the
customer can supply the the heat exchanger and Phillips can provide the packaging. Either option reduces expensive field labor
and increases quality by using our highly qualified fitters in a factory environment.
Gas Recirculation Systems
As a pioneer in gas-driven recirculation systems, Phillips continues to provide engineering assistance and vessel fabrication for
these energy-and maintenance-efficient overfeed systems. Phillips engineers can size the CPR, Gas Recirculating System and
High Side Control to meet your recirculation needs.
Engineering
Our engineering staff can help you custom-design the vessel or packaged system for your application in terms of storage
capacity, liquid-vapor separation, pressure rating, nozzle sizing and mounting requirements.
CAD
We utilize the latest SolidWorks modeling software and can provide 3D models of vessels and systems upon request. Utilizing
DriveWorks software, our Engineers have developed a rapid quotation system integrated with SolidWorks that allows for the
fastest quote turnaround in the industry and quick drawing turnaround for customer approval.
Valve Trains
H.A. Phillips can assist you by sub-assembling valve trains to ensure correct and fast installation at the job site. Phillips
engineers will help you with your selection, whether you prefer solenoid, motorized valve, or Pulse-Width Modulated control.
Danfoss ICF valve stations are also available from Phillips.
Level Columns
Let Phillips provide you with the level column for your vessel. We can supply you with 2”, 2-1/2”, 3” and 4” diameter columns with
Level Eye® sight glasses available with clear or reflex lenses, with or without frost shields, with drain and/or probe connections
and float switch couplings. Options include factory mounted float switches, drain valves and valved and/or flanged vessel
connections. Columns are available with rapid turnaround.
Danfoss Products
H.A. Phillips has been a distributor of Danfoss Industrial Refrigeration products for over 20 years. Our large inventory allows
us to process orders quickly from a single item to a complete project. Danfoss valves come as standard on all our packaged
systems.
1 630.377.0050 [email protected]
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
Vessel Standards
Standard Features
• ASME Certification: All pressure vessels are designed, fabricated, tested, inspected and stamped in accordance with ASME
Section VIII, Division 1 Pressure Vessel Code and are National Board registered.
• Maximum Allowable Working Pressure (MAWP): 250 PSI low side vessels, 300 PSI high side vessels from -20°F to +450°F
Dual stamped to -60°F at reduced pressure (unless otherwise noted). Other MAWPs and lower temperatures are available.
• Heads: 2:1 Semi-elliptical SA 516-70N carbon steel
• Shells: 24” diameter and smaller are SA 106 S/B or SA 53 E/B or S/B pipe. 30” diameter and larger are rolled SA 516-70
carbon steel plate.
• Lifting lugs are standard on all vessels 30” in diameter and larger
• Nozzle Materials: ASTM A-53 B and ASTM A-106B. ASTM A-333 Gr. 6 available where necessary.
• Nozzle Thickness: 2” and smaller, Schedule 80. Larger than 2” are Schedule 40.
• Fittings: Class 3000
Stock Vessels
• All stock vessels including oil pots, dump traps, and Anhydrators include 1/16’’ corrosion allowance as standard in the design.
Available Options
• Stainless Steel construction
• Abrasive blasting
• Radiography (X-Ray)
• Post Weld Heat Treat (PWHT)
Table 2 - Separation Capacities of Separation Vessels, Tons of Refrigeration*
Nominal Vertical Vessel Horizontal Vessel† Horizontal, Split Flow Baffle†°
Diameter -50ºF -20ºF 0ºF 30ºF -50ºF -20ºF 0ºF 30ºF -50ºF -20ºF 0ºF 30ºF
8 7.8 11.8 15.0 21 3.8 5.9 7.5 11 6 9.2 12.5 18.2
10 12.3 18.7 24.0 34 6.2 9.4 12.0 17 10.1 15.0 20.6 29.0
12 17.6 27 34 48 8.8 14.0 17 24 13 19.0 26.0 37
14 22 33 42 58 11.4 17 21 29 18.5 28.0 37 52
16 28 43 55 77 14 22 28 39 24 37 48 68
18 36 55 70 98 18 28 35 49 31.5 48 63 88
20 44 68 87 121 22 34 44 61 39 59 77 108
24 63 97 124 173 31 49 62 87 56 85 110 154
30 100 153 196 273 50 77 98 137 89 136 175 245
Table 1 - Vessel Volumes 36 145 222 284 397 72 111 142 199 130 198 255 356
Shell 42 199 304 389 543 99 152 195 272 178 272 350 489
Nominal Single 2:1
48 261 399 511 713 130 200 256 357 234 358 459 642
Diameter Head, ft³ ft3/ft 54 329 501 643 897 164 251 322 449 295 450 579 808
6 0.043 0.205 60 407 621 797 1111 203 311 399 556 366 559 717 1001
8 0.086 0.360 72 586 892 1146 1598 293 446 573 799 526 804 1032 1440
10 0.177 0.573 84 797 1222 1567 2185 398 611 784 1093 716 1094 1404 1959
12 0.276 0.818 96 1045 1594 2044 2850 522 797 1022 1425 940 1436 1843 2570
14 0.352 0.994 108 1322 2015 2583 3603 661 1008 1292 1802 1189 1816 2330 3250
16 0.500 1.31 120 1630 2485 3186 4444 815 1243 1593 2222 1466 2240 2874 4008
144 2345 3586 4594 6413 1172 1793 2297 3207 2109 3223 4133 5764
18 0.684 1.67
*Assumes 96ºF liquid feed
20 0.907 2.07
†Horizontal capacity assumes max liquid level, including surge, at midpoint of vessel
24 1.44 2.95
°Split flow sizing is for suction accumulators and split flow surge drums. See page 34 for horizontal recirculator sizing.
30 2.67 4.67
36 4.45 6.78 Table 3 - Various Nozzle Capacities, Tons of Refrigeration
42 6.86 9.28 Liquid Wet Suction Nozzle Dry Suction Nozzle
IPS (in)
48 10.0 12.2 Leg* -50 -20ºF 0ºF 30ºF -50 -20ºF 0ºF 30ºF
54 13.8 15.3 ¾ 1 0.21 0.37 0.49 0.68 0.54 1.2 1.9 4.0
60 18.7 19.0 1 2 0.4 0.76 1 1.4 1 2.1 3.5 7.4
72 31.4 27.3 1-¼ 4 0.9 1.6 2.1 2.9 2 4.2 7.0 15
84 49.1 37.3 1-½ 6 1.4 2.4 3.2 4.5 2.9 6.2 10.1 21
96 72.0 48.7 2 11 3.4 5.8 7.7 11 5.5 12 19 41
2½ 18 5.9 9.7 13 17 8.7 18 30 64
108 101 61.6
3 30 9.9 16 21 30 15 31 50 106
120 137 75.9
4 60 21 35 45 63 29 63 105 229
144 234 110 5 105 38 63 82 115 51 108 180 384
*Assumes thickness required Z:\SW Orders\Vessel6 Booklet\BookletTOC
160 62 103 134 187 80 168 275 578
for 250PSIG rating 8 330 127 211 276 386 150 287 443 846
10 600 266 405 535 815 349 531 703 1070
12 925 416 633 837 1274 510 776 1027 1563
14 1150 531 808 1069 1628 628 956 1264 1924
16 1750 752 1144 1514 2303 843 1283 1697 2583
18 2400 998 1518 2009 3058 1097 1670 2210 3363
20 3186 1279 1946 2575 3919 1373 2090 2766 4209
24 5201 1943 2957 3912 5954 2039 3103 4106 6249
* Liquid line capacity doubles if integral oil pot larger than the liquid leg is used.
18
630.377.0050 [email protected] 2
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
W Y V
T
Z
U
Z
REF.
18
A B C D T U V W X Y Z
Est.
Liquid Liquid Column
Model No. Dia. OAH Head Shell Equal Purge Drain Relief Shipping
Inlet Outlet (Qty 2)
Wt. (lbs.)
HPRV-20111 20 111 7½ 96 1¼ ¾ ¾ ¾ ¾ ¾ 1¼ 590
HPRV-20135 20 135 7½ 120 1¼ 1 1 ¾ ¾ ¾ 1¼ 690
HPRV-20207 20 207 7½ 192 1½ 1 1 ¾ ¾ ¾ 1¼ 1020
HPRV-24137 24 137 8½ 120 1½ 1¼ 1¼ ¾ ¾ ¾ 1¼ 1210
HPRV-24209 24 209 8½ 192 2 1½ 1¼ ¾ ¾ ¾ 1¼ 1780
HPRV-30140 30 140 10 120 2½ 1½ 1½ ¾ ¾ ¾ 1¼ 1590
HPRV-30212 30 212 10 192 2½ 1½ 2 ¾ ¾ ¾ 1¼ 2310
HPRV-36143 36 143 11½ 120 2½ 1½ 1½ ¾ ¾ ¾ 1¼ 1940
HPRV-36215 36 215 11½ 192 3 2 2 ¾ ¾ ¾ 1¼ 2810
HPRV-42146 42 146 13 120 3 2 2 ¾ ¾ ¾ 1¼ 2360
HPRV-42218 42 218 13 192 3 2 2 ¾ ¾ ¾ 1¼ 3370
HPRV-48149 48 149 14½ 120 3 2 2 ¾ 1 ¾ 1¼ 2750
HPRV-48221 48 221 14½ 192 3 2 2 ¾ 1 ¾ 1¼ 3910
HPRV-54152 54 152 16 120 3 2 2 ¾ 1 ¾ 1¼ 4140
HPRV-54224 54 224 16 192 4 2½ 2½ ¾ 1 ¾ 1¼ 5880
HPRV-60155 60 155 17½ 120 4 2½ 2½ ¾ 1 ¾ 1¼ 4750
HPRV-60227 60 227 17½ 192 4 3 3 ¾ 1 ¾ 1¼ 6680
HPRV-72161 72 161 20½ 120 4 3 3 ¾ 1 ¾ 1¼ 7550
HPRV-72233 72 233 20½ 192 4 3 3 ¾ 1 1 1¼ 10440
HPRV-84167 84 167 23½ 120 4 3 3 ¾ 1 ¾ 1¼ 9250
HPRV-84239 84 239 23½ 192 5 4 4 ¾ 1 1 1¼ 12630
HPRV-84287 84 287 23½ 240 6 5 5 ¾ 1 1¼ 1¼ 14890
HPRV-96173 96 173 26½ 120 6 5 5 ¾ 1 1 1¼ 13420
HPRV-96245 96 245 26½ 192 8 5 5 ¾ 1 1¼ 1¼ 18050
HPRV-96293 96 293 26½ 240 8 5 5 ¾ 1 1¼ 1¼ 21130
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
3 630.377.0050 [email protected]
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
B A
C D
T V Y W U Z
REF.
X Z
A B C D T U V W X Y Z
Est.
Liquid Column
Model No. Dia. OAL Head Shell Liquid Inlet Equal Purge Drain Relief Shipping
Outlet (Qty 2)
Wt. (lbs.)
HPRH-20111 20 111 7½ 96 1¼ ¾ ¾ ¾ ¾ ¾ 1¼ 600
HPRH-20135 20 135 7½ 120 1¼ 1 1 ¾ ¾ ¾ 1¼ 700
HPRH-24113 24 113 8½ 96 1½ 1¼ 1¼ ¾ ¾ ¾ 1¼ 1050
HPRH-24137 24 137 8½ 120 1½ 1¼ 1¼ ¾ ¾ ¾ 1¼ 1240
HPRH-30116 30 116 10 96 2 1¼ 1¼ ¾ ¾ ¾ 1¼ 1380
HPRH-30140 30 140 10 120 2½ 1½ 1½ ¾ ¾ ¾ 1¼ 1630
HPRH-36119 36 119 11½ 96 2 1½ 1½ ¾ ¾ ¾ 1¼ 1730
HPRH-36143 36 143 11½ 120 2½ 1½ 1½ ¾ ¾ ¾ 1¼ 2020
HPRH-42122 42 122 13 96 2½ 1½ 1½ ¾ ¾ ¾ 1¼ 2120
HPRH-42146 42 146 13 120 3 2 2 ¾ ¾ ¾ 1¼ 2460
HPRH-48149 48 149 14½ 120 3 2 2 ¾ 1 ¾ 1¼ 2890
HPRH-48221 48 221 14½ 192 3 2 2 ¾ 1 ¾ 1¼ 4040
HPRH-48269 48 269 14½ 240 4 2½ 2½ ¾ 1 ¾ 1¼ 4820
HPRH-54152 54 152 16 120 3 2 2 ¾ 1 ¾ 1¼ 4280
HPRH-54224 54 224 16 192 4 3 3 ¾ 1 ¾ 1¼ 6030
HPRH-54272 54 272 16 240 4 3 3 ¾ 1 ¾ 1¼ 7180
HPRH-60155 60 155 17½ 120 4 2½ 2½ ¾ 1 ¾ 1¼ 4930
HPRH-60227 60 227 17½ 192 4 3 3 ¾ 1 ¾ 1¼ 6860
HPRH-60275 60 275 17½ 240 4 3 3 ¾ 1 1 1¼ 8150
HPRH-72233 72 233 20½ 192 5 3 3 ¾ 1 1 1¼ 10490
HPRH-72281 72 281 20½ 240 5 4 4 ¾ 1 1 1¼ 12440
HPRH-84239 84 239 23½ 192 5 4 4 ¾ 1 1 1¼ 12770
HPRH-84287 84 287 23½ 240 6 4 4 ¾ 1 1¼ 1¼ 15020
HPRH-96245 96 245 26½ 192 6 4 4 ¾ 1 1¼ 1¼ 18140
HPRH-96293 96 293 26½ 240 8 4 4 ¾ 1 1¼ 1¼ 21220
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
18
630.377.0050 [email protected] 4
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
W Y V
S T
Z A
R
STANDPIPE
D B
U
Z
REF.
18
A B C D R S T U V W X Y Z
Est.
To Oil From Oil Liquid Column
Model No. Dia. OAH Head Shell Standpipe Liquid Inlet Equal Purge Drain Relief Shipping
Cooler Cooler Outlet (Qty 4)
Wt. (lbs.)
HPRTSV-20135 20 135 7½ 120 1½ 2 6"Ø x 18" 1¼ ¾ 1 ¾ ¾ ¾ 1¼ 750
HPRTSV-24137 24 137 8½ 120 2 2½ 6"Ø x 18" 1½ 1¼ 1¼ ¾ ¾ ¾ 1¼ 900
HPRTSV-30140 30 140 10 120 2 2½ 6"Ø x 18" 2 1¼ 1¼ ¾ ¾ ¾ 1¼ 1680
HPRTSV-36143 36 143 11½ 120 2½ 3 6"Ø x 18" 2 1½ 1½ ¾ ¾ ¾ 1¼ 2050
HPRTSV-42146 42 146 13 120 2½ 3 6"Ø x 18" 2½ 1½ 2 ¾ ¾ ¾ 1¼ 2500
HPRTSV-48221 48 221 14½ 192 3 4 6"Ø x 18" 3 2 2 ¾ 1 ¾ 1¼ 4090
HPRTSV-54224 54 224 16 192 3 4 6"Ø x 18" 4 3 3 ¾ 1 ¾ 1¼ 6100
HPRTSV-60227 60 227 17½ 192 3 4 6"Ø x 18" 4 3 3 ¾ 1 ¾ 1¼ 6940
HPRTSV-72281 72 281 20½ 240 4 5 6"Ø x 18" 5 4 4 ¾ 1 1 1¼ 12750
HPRTSV-84287 84 287 23½ 240 5 6 8"Ø x 18" 6 4 4 ¾ 1 1¼ 1¼ 18240
HPRTSV-96293 96 293 26½ 240 5 6 10"Ø x 18" 8 4 4 ¾ 1 1¼ 1¼ 21760
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
5 630.377.0050 [email protected]
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
B A
C D 2
T V Y S W U Z
REF.
X
R Z
A B C D R S T U V W X Y Z
Est.
To Oil From Oil Liquid Liquid Column
Model No. Dia. OAL Head Shell Equal Purge Drain Relief Shipping
Cooler Cooler Inlet Outlet (Qty 2)
Wt. (lbs.)
HPRTSH-20135 20 135 7½ 120 1½ 2 1¼ ¾ 1 ¾ ¾ ¾ 1¼ 690
HPRTSH-24137 24 137 8½ 120 2 2½ 1½ 1¼ 1¼ ¾ ¾ ¾ 1¼ 1250
HPRTSH-30140 30 140 10 120 2 2½ 2 1¼ 1¼ ¾ ¾ ¾ 1¼ 1630
HPRTSH-36143 36 143 11½ 120 2½ 3 2 1½ 1½ ¾ ¾ ¾ 1¼ 2020
HPRTSH-42146 42 146 13 120 2½ 3 2½ 1½ 2 ¾ ¾ ¾ 1¼ 2460
HPRTSH-48221 48 221 14½ 192 3 4 3 2 2 ¾ 1 ¾ 1¼ 4050
HPRTSH-54224 54 224 16 192 3 4 4 3 3 ¾ 1 ¾ 1¼ 6060
HPRTSH-60227 60 227 17½ 192 3 4 4 3 3 ¾ 1 ¾ 1¼ 6870
HPRTSH-72281 72 281 20½ 240 4 5 5 4 4 ¾ 1 1 1¼ 12460
HPRTSH-84287 84 287 23½ 240 5 6 6 4 4 ¾ 1 1¼ 1¼ 15040
HPRTSH-96293 96 293 26½ 240 5 6 8 4 4 ¾ 1 1¼ 1¼ 21240
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
18
630.377.0050 [email protected] 6
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
R Y S
D B
V
Z
REF.
X
18
A B C D R S T U V W X Y Z
Est.
Liq Trans. Column
Model No. Dia. OAH Head Shell Gas Inlet Gas Outlet Oil Pot Vent Liq. Inlet Liq. Outlet Drain Relief Shipping
Inlet (Qty 2)
Wt. (lbs.)
CPRV-20144 20 144 7½ 129 ¾ ¾ ¾ ¾ 1¼ ¾ 1 ¾ 1¼ 740
CPRV-24144 24 144 8½ 127 ¾ ¾ ¾ 1 1¼ ¾ 1 ¾ 1¼ 1260
CPRV-24192 24 192 8½ 175 ¾ ¾ ¾ 1¼ 1½ ¾ 1 ¾ 1¼ 1640
CPRV-30140 30 140 10 120 ¾ ¾ ¾ 1¼ 1½ ¾ 1 ¾ 1¼ 1590
CPRV-36143 36 143 11½ 120 ¾ ¾ ¾ 1¼ 2 ¾ 1 ¾ 1¼ 1940
CPRV-42146 42 146 13 120 ¾ ¾ ¾ 1½ 2 1¼ 1 ¾ 1¼ 2360
CPRV-48149 48 149 14½ 120 ¾ 1¼ ¾ 2 2½ 1¼ 1 ¾ 1¼ 2750
CPRV-48197 48 197 14½ 168 ¾ 1¼ ¾ 2 2½ 1¼ 1 ¾ 1¼ 3520
CPRV-54152 54 152 16 120 ¾ 1¼ ¾ 2 3 1¼ 1 ¾ 1¼ 4150
CPRV-54200 54 200 16 168 ¾ 1¼ ¾ 2 3 1¼ 1 ¾ 1¼ 5300
CPRV-60155 60 155 17½ 120 ¾ 1¼ ¾ 2 3 2 1¼ ¾ 1¼ 4750
CPRV-60203 60 203 17½ 168 ¾ 1½ ¾ 2½ 4 2 1¼ ¾ 1¼ 6040
CPRV-72161 72 161 20½ 120 ¾ 1½ ¾ 2½ 4 2 1¼ ¾ 1¼ 7550
CPRV-72209 72 209 20½ 168 ¾ 2 ¾ 3 4 2 1¼ ¾ 1¼ 9480
CPRV-84167 84 167 23½ 120 ¾ 2 1 3 4 3 1½ ¾ 1¼ 9260
CPRV-84215 84 215 23½ 168 ¾ 2 1 3 4 3 1½ 1 1¼ 13690
CPRV-84239 84 239 23½ 192 1 2 1 3 4 3 1½ 1 1¼ 15030
CPRV-96173 96 173 26½ 120 1 2 1 3 4 3 1½ ¾ 1¼ 13400
CPRV-96221 96 221 26½ 168 1 2 1 3 5 3 1½ 1 1¼ 16490
CPRV-96245 96 245 26½ 192 1 2½ 1 4 5 3 1½ 1 1¼ 18030
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
7 630.377.0050 [email protected]
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
Pilot Receiver
W Y
W Y
U
U
Z
Z
D B
Z
D B
Z V
REF.
REF.
C
X
X
18
18
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
18
630.377.0050 [email protected] 8
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
Thermo-Syphon Receiver
Y
Z 2
W
D B
REF.
U
Vertical
B A
C D
V Z Y
REF.
W X
U
Horizontal
A B C D U V W X Y Z
Heat of Est.
Oil Cooler Oil Cooler Liq.
Model No.* Rejection Dia. OAL/OAH Head Shell Liq. Inlet Vent Relief Shipping
Supply Return Outlet
[Btu/min]** Wt. (lbs.)
TSR0836V/H 1500 8 36 4 28 1¼ 1½ 1½ 1½ 1½ ½ 120
TSR1048V/H 3000 10 48 5 38 1½ 2 2 2 1½ ½ 170
TSR1060V/H 4500 10 60 5 50 2 2½ 2½ 2½ 2 ½ 200
TSR1272V/H 9000 12 72 5½ 61 2 2½ 3 3 2½ ½ 260
TSR1672V/H 15000 16 72 6½ 59 2½ 3 4 4 3 ½ 370
TSR2072V/H 22500 20 72 7½ 57 3 4 4 4 4 ¾ 450
TSR2472V/H 30000 24 72 8½ 55 4 5 5 5 4 ¾ 730
TSR3072V/H 45000 30 72 10 52 5 6 5 5 5 ¾ 920
TSR3084V/H 60000 30 84 10 64 5 6 6 6 5 ¾ 1040
* Specify vertical or horizontal vessel by indicating "V" or "H" suffix in model number
** Capacities listed are for R-717. For R-22, multiply Heat of Rejection by 0.3
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
9 630.377.0050 [email protected]
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
Vertical Intercooler
R* Y R*
S T
VACUUM WEEP
BREAKER HOLE A
D B
U
V
*COIL IS OPTIONAL
REF.
Z 1
22
C
18
A B C D R S T U V W X Y Z
OPTIONAL *Est.
OPTIONAL Liquid Oil Pot Column
Model No. Dia. OAH Head Shell Coil Conn. Inlet Outlet Liquid Out Drain Relief Shipping
Coil Makeup Vent (Qty 2)
(Qty 2) Wt. (lbs.)
ICV-1696 16 96 6½ 83 S-W,23.5T ¾ 3 3 ¾ ¾ ¾ 1 ¾ 1¼ 730
ICV-2096 20 96 7½ 81 D-W,16.5T ¾ 4 4 1 1 ¾ 1 ¾ 1¼ 850
ICV-2496 24 96 8½ 79 D-W,14.5T 1 5 5 1¼ 1¼ ¾ 1 ¾ 1¼ 1360
ICV-30116 30 116 10 96 D-W,15.5T 1¼ 6 6 1½ 1½ ¾ 1 ¾ 1¼ 2250
ICV-36119 36 119 11½ 96 D-W,17.5T 1¼ 8 8 2 2 ¾ 1 ¾ 1¼ 2990
ICV-42122 42 122 13 96 D-W,16.5T 1¼ 8 8 2½ 2½ ¾ 1 ¾ 1¼ 3580
ICV-48149 48 149 14½ 120 T-W,13.5T 1½ 10 10 2½ 2½ ¾ 1 ¾ 1¼ 5350
ICV-54152 54 152 16 120 T-W,12.5T 2 10 10 3 3 ¾ 1 ¾ 1¼ 7620
ICV-60155 60 155 17½ 120 T-W,13.5T 2 12 12 3 3 ¾ 1¼ ¾ 1¼ 9060
ICV-72161 72 161 20½ 120 Q-W,16.5T 1½ 14 14 4 4 ¾ 1¼ ¾ 1¼ 12740
ICV-84167 84 167 23½ 120 Q-W,17.5T 2 16 16 5 5 ¾ 1½ ¾ 1¼ 15440
ICV-96173 96 173 26½ 120 Q-W,18.5T 2½ 18 18 5 5 ¾ 1½ ¾ 1¼ 20360
*Optional coil included in estimated vessel shipping weight.
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
18
630.377.0050 [email protected] 10
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
A
S T
V WEEP
HOLE
D B
Z
REF.
X
18
A B C D S T U V W X Y Z
Est.
Suction Suction Oil Pot 3-Way Column
Model No. Dia. OAH Head Shell Liquid Out Drain Relief Shipping
Inlet Outlet Vent Vent (Qty 2)
Wt. (lbs.)
ACV-1272 12 72 5½ 61 3 3 1¼ ¾ ¾ 1 ½ 1¼ 290
ACV-1696 16 96 6½ 83 4 3 1¼ ¾ ¾ 1 ¾ 1¼ 440
ACV-2096 20 96 7½ 81 5 4 1¼ ¾ ¾ 1 ¾ 1¼ 560
ACV-2496 24 96 8½ 79 6 5 1¼ ¾ ¾ 1 ¾ 1¼ 950
ACV-30116 30 116 10 96 8 6 1½ ¾ ¾ 1 ¾ 1¼ 1450
ACV-36119 36 119 11½ 96 10 8 2 ¾ ¾ 1 ¾ 1¼ 1830
ACV-42122 42 122 13 96 10 8 2 ¾ ¾ 1 ¾ 1¼ 2220
ACV-48149 48 149 14½ 120 10 8 3 ¾ 1¼ 1 ¾ 1¼ 2970
ACV-54152 54 152 16 120 12 10 3 ¾ 1¼ 1 ¾ 1¼ 4470
ACV-60155 60 155 17½ 120 12 12 3 ¾ 1¼ 1¼ ¾ 1¼ 5140
ACV-72161 72 161 20½ 120 16 14 4 ¾ 1¼ 1¼ ¾ 1¼ 8130
ACV-84167 84 167 23½ 120 18 16 4 1 1¼ 1½ ¾ 1¼ 10050
ACV-96173 96 173 26½ 120 20 18 (2) 4 1 2 1½ ¾ 1¼ 14440
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
11 630.377.0050 [email protected]
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
B A
B A
C D
C D
TT
REF.
Y Y ZZ
REF.
SS
WW V V
(4)
(4)
WELD
WELD
PADS
PADS
ZZ
UU
XX
A B C D S T U V W X Y Z
Est.
Sump Gas Liquid Oil Pot 3-Way Column
Model No. Dia. OAL Head Shell Sump Dia. Gas Inlet Drain Relief Shipping
Length Outlet Out Vent Vent (Qty 2)
Wt. (lbs.)
ACH-30140 30 140 10 120 4 18 6 5 1¼ ¾ ¾ 1 ¾ 1¼ 1880
ACH-36143 36 143 11½ 120 4 18 8 6 1¼ ¾ ¾ 1 ¾ 1¼ 2250
ACH-42146 42 146 13 120 4 18 8 6 1½ ¾ 1¼ 1 ¾ 1¼ 2620
ACH-48149 48 149 14½ 120 4 18 8 6 2 ¾ 1¼ 1 ¾ 1¼ 3000
ACH-54152 54 152 16 120 6 18 10 8 2 ¾ 1¼ 1 ¾ 1¼ 4490
ACH-60155 60 155 17½ 120 6 18 10 8 2 ¾ 1¼ 1¼ ¾ 1¼ 5860
ACH-72161 72 161 20½ 120 8 18 12 10 3 ¾ 1¼ 1¼ ¾ 1¼ 7830
ACH-84167 84 167 23½ 120 8 20 12 12 3 1 1¼ 1½ ¾ 1¼ 9530
ACH-96173 96 173 26½ 120 10 20 14 12 4 1 1¼ 1½ ¾ 1¼ 13390
ACH-108179 108 179 29½ 120 10 20 16 14 4 1 1¼ 1½ 1 1¼ 18180
ACH-120185 120 185 32½ 120 10 20 18 16 4 1 1¼ 1½ 1 1¼ 23980
ACH-144197 144 197 38½ 120 12 20 20 18 (2) 4 1 2 1½ 1¼ 1¼ 36270
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
18
630.377.0050 [email protected] 12
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
T Y T
V
U
WEEP
HOLE
D B
Z
REF.
18
A B C D T U V W X Y Z
*Est.
Alternate Coil Conn. Suction Suction Oil Pot Column
Model No. Dia. OAH Head Shell Coil Drain Relief Shipping
Coil (Qty 2) Inlet Outlet Vent (Qty 2)
Wt. (lbs.)
ACCV-1696 16 96 6½ 83 S-W,17.5T ¾ 4 3 ¾ 1 ¾ 1¼ 640
ACCV-2096 20 96 7½ 81 S-W,17.5T 1 5 4 ¾ 1 ¾ 1¼ 780
ACCV-2496 24 96 8½ 79 S-W,17.5T 1 6 5 ¾ 1 ¾ 1¼ 1190
ACCV-30116 30 116 10 96 S-W,20.5T 1¼ 8 6 ¾ 1 ¾ 1¼ 1920
ACCV-36119 36 119 11½ 96 S-W,20.5T 1½ 10 8 ¾ 1 ¾ 1¼ 2520
ACCV-42122 42 122 13 96 S-W,18.5T D-W,13.5T 1½ 10 8 ¾ 1 ¾ 1¼ 2960
ACCV-48149 48 149 14½ 120 S-W,17.5T D-W,12.5T 2 10 8 ¾ 1 ¾ 1¼ 3850
ACCV-54152 54 152 16 120 S-W,17.5T D-W,13.5T 2 12 10 ¾ 1 ¾ 1¼ 5450
ACCV-60155 60 155 17½ 120 S-W,17.5T D-W,14.5T 2 12 12 ¾ 1¼ ¾ 1¼ 6230
ACCV-72161 72 161 20½ 120 S-W,17.5T D-W,14.5T 2 16 14 ¾ 1¼ ¾ 1¼ 9220
ACCV-84167 84 167 23½ 120 S-W,17.5T D-W,14.5T 2 18 16 1 1½ ¾ 1¼ 11140
ACCV-96173 96 173 26½ 120 S-W,17.5T D-W,14.5T 2 20 18 1 1½ ¾ 1¼ 15540
*Single wound coil included in estimated vessel shipping weight.
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
13 630.377.0050 [email protected]
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
Economizer
W* W*
D B
Z
REF. *COIL IS OPTIONAL
X
18
A B C D S T U V W X Y Z
Coil *Est.
Optional Suction Liquid Liquid Oil Pot Column Econ.
Model No. Dia. OAH Head Shell Conn. Drain Relief Sys. Tons Shipping
Coil Outlet Inlet Outlet Vent (Qty 2) Tons
(Qty 2) Wt. (lbs.)
ECON-1084 10 84 5 74 ¾ ¾ ¾ ¾ ½ 1 ½ 1¼ 7 43 260
ECON-1284 12 84 5½ 73 1 ¾ ¾ ¾ ½ 1 ½ 1¼ 12 62 300
ECON-1696 16 96 6½ 83 S-W,23.5T 1¼ 1 1 ¾ ¾ 1 ¾ 1¼ 20 98 620
ECON-2096 20 96 7½ 81 D-W,16.5T 1½ 1 1 ¾ ¾ 1 ¾ 1¼ 31 155 720
ECON-2496 24 96 8½ 79 D-W,14.5T 2 1 1 ¾ 1 1 ¾ 1¼ 51 225 1130
ECON-30116 30 116 10 96 D-W,15.5T 2½ 1½ 1½ ¾ 1¼ 1 ¾ 1¼ 75 350 1820
ECON-36119 36 119 11½ 96 D-W,17.5T 2½ 1½ 1½ ¾ 1¼ 1 ¾ 1¼ 75 508 2320
ECON-42122 42 122 13 96 D-W,16.5T 3 1½ 1½ ¾ 1¼ 1 ¾ 1¼ 122 696 2750
ECON-48149 48 149 14½ 120 T-W,13.5T 4 2 2 ¾ 1½ 1 ¾ 1¼ 203 913 3600
ECON-54152 54 152 16 120 T-W,12.5T 4 2 2 ¾ 2 1 ¾ 1¼ 203 1150 5130
ECON-60155 60 155 17½ 120 T-W,13.5T 5 2½ 2½ ¾ 2 1¼ ¾ 1¼ 308 1425 5840
System Tons at +55°F/+95°F
Economizer Tons based on suction outlet line size at +55°F/+95°F
*Optional coil included in estimated vessel shipping weight.
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
18
630.377.0050 [email protected] 14
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
B A
C D
V Z Y
REF.
W U Z
A B C D U V W X Y Z
Est.
Gas Column
Model No. Dia. OAL Head Shell Gas Inlet Liquid Leg Makeup Relief Shipping
Outlet (Qty 2)
Wt. (lbs.)
SDH-12048 12 48 5½ 37 2½ 2 3 ¾ ½ 1¼ 200
SDH-16060 16 60 6½ 47 3 2½ 4 ¾ ½ 1¼ 330
SDH-20072 20 72 7½ 57 4 3 4 ¾ ¾ 1¼ 450
SDH-24072 24 72 8½ 55 4 4 4 1 ¾ 1¼ 730
SDH-30092 30 92 10 72 5 4 5 1¼ ¾ 1¼ 1140
SDH-36095 36 95 11½ 72 6 5 6 1½ ¾ 1¼ 1410
SDH-42122 42 122 13 96 8 6 8 1½ ¾ 1¼ 2150
SDH-48149 48 149 14½ 120 8 8 8 2 ¾ 1¼ 2880
SDH-54152 54 152 16 120 8 8 8 2½ ¾ 1¼ 4280
SDH-60155 60 155 17½ 120 10 8 10 2½ ¾ 1¼ 4920
SDH-72161 72 161 20½ 120 10 10 10 3 ¾ 1¼ 7660
SDH-84167 84 167 23½ 120 12 10 12 3 ¾ 1¼ 9480
SDH-96173 96 173 26½ 120 12 12 12 4 ¾ 1¼ 13350
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
15 630.377.0050 [email protected]
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
D B
X
REF.
Z
W
A B C D U V W X Y Z
Est.
Column
Model No. Dia. OAH Head Shell Gas Inlet Gas Outlet Liquid Leg Makeup Relief Shipping
(Qty 2)
Wt. (lbs.)
SDV-12048 12 48 5½ 37 4 3 4 ¾ ½ 1¼ 200
SDV-16054 16 54 6½ 41 5 4 5 ¾ ½ 1¼ 370
SDV-20060 20 60 7½ 45 6 5 6 1 ½ 1¼ 370
SDV-24060 24 60 8½ 43 6 6 8 1¼ ¾ 1¼ 620
SDV-30080 30 80 10 60 8 8 8 1½ ¾ 1¼ 1020
SDV-36083 36 83 11½ 60 10 8 10 2 ¾ 1¼ 1330
SDV-42098 42 98 13 72 10 8 10 2½ ¾ 1¼ 1760
SDV-48125 48 125 14½ 96 10 8 10 2½ ¾ 1¼ 2480
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
18
630.377.0050 [email protected] 16
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
B A
C D
V Y Z
REF.
(4)
WELD
PADS T
U W Z
A B C D T U V W X Y Z
Est.
Oil Pot Column
Model No. Dia. OAL Head Shell Gas Inlet Gas Outlet Liquid Leg Makeup Relief Shipping
Vent (Qty 2)
Wt. (lbs.)
SFSDH-12048 12 48 5½ 37 ¾ 4 3 4 ¾ ½ 1¼ 200
SFSDH-16060 16 60 6½ 47 ¾ 4 3 4 ¾ ½ 1¼ 290
SFSDH-20072 20 72 7½ 57 ¾ 5 4 5 1 ¾ 1¼ 430
SFSDH-24072 24 72 8½ 55 ¾ 6 5 6 1¼ ¾ 1¼ 770
SFSDH-30092 30 92 10 72 ¾ 8 6 8 1½ ¾ 1¼ 1340
SFSDH-36095 36 95 11½ 72 ¾ 8 6 8 1½ ¾ 1¼ 1600
SFSDH-42122 42 122 13 96 ¾ 10 8 10 2 ¾ 1¼ 2440
SFSDH-48149 48 149 14½ 120 ¾ 10 8 10 2½ ¾ 1¼ 3270
SFSDH-54152 54 152 16 120 ¾ 10 10 10 2½ ¾ 1¼ 4790
SFSDH-60155 60 155 17½ 120 ¾ 12 10 12 3 ¾ 1¼ 5460
SFSDH-72161 72 161 20½ 120 ¾ 14 12 14 4 ¾ 1¼ 8260
SFSDH-84167 84 167 23½ 120 1 16 16 16 4 ¾ 1¼ 10390
SFSDH-96173 96 173 26½ 120 1 18 16 18 5 ¾ 1¼ 14350
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
17 630.377.0050 [email protected]
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
C D
V W X
REF.
2
Z*
*OPTIONAL HEATER CONNECTION
NOT INCLUDED ON STOCK OIL POTS
A B C D V W X Y Z
Est.
Model No. Dia. OAL Head Shell Inlet Vent Relief Drain Heater* Shipping
Wt. (lbs.)
6P 6 36 3½ 29 1 ¾ ½ ½ 1 70
8P 8 36 4 28 1 ¾ ½ ½ 2 90
10P 10 36 5 26 1¼ ¾ ½ ½ 2 110
12P 12 36 5½ 25 1½ 1 ½ ½ 2 130
*Optional heater connection - Not included on stock oil pots
Phillips stock oil pots
• 4 sizes of standard design oil pots, 6"x36", 8"x36", 10"x36", 12"x36"
• Stock oil pot nozzles are as shown in table above, less the heater coupling
• Standard rating is -50ºF @ 300 PSI
• Sold in 3 trim levels, identified by the following suffix:
• PA - Oil pot only
• PB - Oil Pot with 250 PSI relief valve
• PC - Oil pot with 250 PSI relief valve, inlet & vent globe valves, drain valve train including stop valve and spring-return valve
• Example: 8" stock design oil pot with all accessories: 8PC
OPTIONAL
END CONNECTIONS
4''(MIN.)
2'' S/80
PIPE OPTIONAL
TO CONNECTIONS OPTIONAL
SUIT CONNECTIONS
OPTIONAL FLOAT SWITCH
CONNECTIONS
D 3/4 FPT 3'' S/40
D D D PIPE D
'V' 2 1/2''
(TOTAL S/40 4'' S/40
VISION) PIPE PIPE
Z:\SW Orders\Vessel Booklet\BookletTOC
1-1/4'' 1-1/4''
1'' OR
1-1/4'' OR
PIPE LARGER
PIPE LARGER
18
630.377.0050 [email protected] 18
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
R Z
WEEP Q
HOLE A
D B
V W V
S PUMP SUCTION W/
VORTEX BREAKER
Z MOTOR COOLANT
U RECIRC./PUMP VENT*
REF.
V PUMP BYPASS
. C
W OIL POT VENT
X *USAGE DEPENDS ON
PUMP TYPE
60
S S
A B C D Q R S T U V W X Y Z
Pump Pump Est.
Suction Suction Pump Oil Pot Column
Model No. Dia. OAH Head Shell Makeup Vent/Recirc Bypass Drain† Relief Shipping
Inlet Outlet Suction Vent (Qty 2)
(Qty 2) (Qty 2) Wt. (lbs.)
RVV-24113 24 113 8½ 96 6 5 4 1¼ ¾ ¾ ¾ 1 ¾ 1¼ 1300
RVV-30116 30 116 10 96 8 6 4 1½ ¾ ¾ ¾ 1 ¾ 1¼ 1700
RVV-36119 36 119 11½ 96 8 6 4 2 ¾ ¾ ¾ 1 ¾ 1¼ 2020
RVV-42146 42 146 13 120 10 8 4 2½ ¾ ¾ ¾ 1 ¾ 1¼ 2880
RVV-48149 48 149 14½ 120 10 10 4 2½ ¾ ¾ ¾ 1 ¾ 1¼ 3330
RVV-54152 54 152 16 120 12 10 5 3 ¾ ¾ ¾ 1 ¾ 1¼ 4800
RVV-60155 60 155 17½ 120 12 12 5 3 ¾ 1 ¾ 1¼ ¾ 1¼ 5520
RVV-72161 72 161 20½ 120 16 14 6 4 ¾ 1 ¾ 1¼ ¾ 1¼ 8600
RVV-84167 84 167 23½ 120 18 16 8 5 ¾ 1¼ 1 1½ ¾ 1¼ 10610
RVV-96173 96 173 26½ 120 20 18 8 5 ¾ 1¼ 1 1½ ¾ 1¼ 15220
RVV-108179 108 179 29½ 120 20 20 10 6 ¾ 1¼ 1 1½ 1 1¼ 20200
RVV-120185 120 185 32½ 120 24 24 10 6 ¾ 1½ 1 1½ 1 1¼ 26840
RVV-144197 144 197 38½ 120 24 24 12 8 ¾ 1½ 1 1½ 1¼ 1¼ 39970
†For temperatures below -20° oil drain size is 1-1/2''
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
19 630.377.0050 [email protected]
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
B A
C D
R
REF.
T Y
Z Q
(4) WELD
PADS
U* V Z W S S
*USAGE DEPENDS
ON PUMP TYPE X
A B C D I J Q R S T U V W X Y Z
Pump Pump Est.
Drop Leg Drop Leg Suction Suction Pump Oil Pot Column
Model No. Dia. OAL Head Shell Makeup Vent/Recirc Bypass Oil Drain† Relief Shipping
Dia. Len. Inlet Outlet Suction Vent (Qty 2)
(Qty 2) (Qty 2) Wt. (lbs.)
RVH-24137 24 137 8½ 120 4 12 6 5 4 1¼ ¾ ¾ ¾ 1 ¾ 1¼ 1580
RVH-30140 30 140 10 120 4 12 8 6 4 1½ ¾ ¾ ¾ 1 ¾ 1¼ 2020
RVH-36143 36 143 11½ 102 4 12 8 6 4 1½ ¾ ¾ ¾ 1 ¾ 1¼ 2370
RVH-42146 42 146 13 120 4 12 10 8 4 2 ¾ ¾ ¾ 1 ¾ 1¼ 2880
RVH-48149 48 149 14½ 120 4 12 10 8 4 2½ ¾ ¾ ¾ 1 ¾ 1¼ 3260
RVH-54152 54 152 16 120 4 12 10 10 4 2½ ¾ 1 ¾ 1 ¾ 1¼ 4660
RVH-60155 60 155 17½ 120 4 12 12 10 5 3 ¾ 1 ¾ 1¼ ¾ 1¼ 5300
RVH-72161 72 161 20½ 120 4 12 14 12 6 4 ¾ 1 ¾ 1¼ ¾ 1¼ 8020
RVH-84167 84 167 23½ 120 4 12 16 16 8 4 ¾ 1 1 1½ ¾ 1¼ 9840
RVH-96173 96 173 26½ 120 4 12 18 16 8 5 ¾ 1¼ 1 1½ ¾ 1¼ 13290
RVH-108179 108 179 29½ 120 4 12 20 18 8 5 ¾ 1¼ 1 1½ 1 1¼ 18020
RVH-120185 120 185 32½ 120 4 12 24 20 10 6 ¾ 1½ 1 1½ 1 1¼ 23730
RVH-144197 144 197 38½ 120 4 12 24 24 12 8 ¾ 1½ 1 1½ 1¼ 1¼ 36430
†For temperatures below -20° oil drain size is 1-1/2''
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
18
630.377.0050 [email protected] 20
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
A B
V W
45°
U* U* Y
A B U V W Y Z
21 630.377.0050 [email protected]
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
Z
Z
A
Y
A
Y
T
V
V T
U
D
U
B
V C B
V
X W X
W
REF. REF.
C
C
4
4
8''-20'' 24''-48''
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
18
630.377.0050 [email protected] 22
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
If your air purger is venting air, it is leaving behind the moisture that entered the system with the air. Since water is condensable, it is not removed
by the purger. Rather, it seeks the lowest temperature location in the system. That's where it can be removed.
Aside from being a great preventative maintenance tool, the payback can be quite fast. Each percent of water in the ammonia is equal to a 1% drop
in compressor efficiency. Put another way, water increases the temperature - pressure relationship of the mixture, causing the compressor to work
harder to maintain the same temperature. A clean refrigeration system uses much less energy - that translates into savings.
Trim levels:
• ANH: Bare Anhydrator vessel
• ANH-CV: Anhydrator vessel with valve group shipped loose
• ANH-CV-A: Anyhydrator vessel with valve group shipped factory installed (relief, liquid feed stop valve, and strainer ship loose)
Also availalble: 100ml lab-grade moisture sampling container, part number ANH-MS
Moisture sampling test stand, part number ANH-AS
SUCTION OUT
RELIEF VALVE
SHIP LOOSE ITEM
CONTAMINATED
LIQUID IN
Z:\Engineering\Vessel Spreadsheets\BookletTOC
OUTLET TO SYSTEM
INLET- HIGH PRESSURE LIQUID
CONTAMINENT DRAIN
Accessories
The Phillips PUR Air Purger is a simple, robust, high-capacity device that removes non-condensable gases from the refrigerant vapor in a system.
The unit operates by condensing foul gas (the mixture of refrigerant vapor and non-condensables) from one or more purge points, metering the
purified liquid refrigerant back to the system through a protected suction connection, and venting the non-condensables to atmosphere.
The single size model PUR will effectively purge non-condensables from any sized refrigeration system and works with all typical refrigerants.
The smaller PURJR is designed to operate single condensor systems.
VENT SOLENOID
WATER IN
AIR VENT
LEVEL LEVEL PROBE
PROBE
VENT SOLENOID
WET
SUCTION
LINE
WATER IN WET
TEMP SUCTION
AIR VENT LINE
SENSOR
TEMP
SENSOR
TEMP SENSOR
AIR & WATER ORIFICE ACCESS ON FOUL GAS
OUT
LIQUID SUPPLY FOUL GAS INLET
(BACKSIDE)
LIQUID SUPPLY
EXPANSION
SOLENOID
The
The PURPURAirAir Purger
Purger ships
ships bracket
bracket mounted
mounted with
with thethe following
following available
available options:
options: The PURJR Air Purger ships with factory insulation, bubbler, and
• Factory
Factory insulation
insulation The PURJR Air Purger ships with factory insulation, bubbler, and 3-point controller included.
• Bubbler
Bubbler
• 12-Point
12-Point control
control with
with available
available 29-point
29-point expansion
expansion module.
module.
When
When ordering,
ordering, please
please specify
specify desired
desired trimtrim level:
level:
• PUR-CV:
PUR-CV: Purger
Purger with
with valves
valves
• PUR-B:
PUR-B: Purger
Purger with
with valves
valves andand bubbler
bubbler
• PUR-I:
PUR-I: Purger
Purger with
with valves
valves andand insulation
insulation
• PUR-P:
PUR-P: Purger
Purger with
with valves
valves andand 12-point
12-point control
control panel
panel
• PUR-BI:
PUR-BI: Purger
Purger withwith valves,
valves, bubbler
bubbler andand insulation
insulation
• PUR-BP:
PUR-BP: Purger
Purger withwith valves,
valves, bubbler
bubbler andand 12-point
12-point control
control panel
panel
• PUR-IP:
PUR-IP: Purger
Purger withwith valves,
valves, insulation
insulation andand 12-point
12-point control
control panel
panel
• PUR-BIP:
PUR-BIP: Purger
Purger withwith valves,
valves, bubbler,
bubbler, insulation
insulation andand 12-point
12-point control
control panel
panel
• Purge
Purge point
point expansion
expansion module
module ordered
ordered at time
at time of purchase
of purchase depending
depending on on system
system requirements
requirements
18
630.377.0050 [email protected] 24
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
PRESSURE
REGULATOR
LIQUID TOTAL LIQUID DUMP TRAP MIN. DRAIN LINE SIZES (IPS-IN.)
DIM. SHIPPING
RETURN TONS AT RETURN SIZE HEIGHT 'X' L-1 L-2 L-4
'Y' L-3 WEIGHT
UNIT ACCUMU- CAPACITY (D. X HT.) REQ'D (TRAP) (GAS) DRAIN
(IN.) (LBS.)
FROM HIGH
SIDE CONTROL
L-4
L-2 L-4
'Y' L-3 WEIGHT
UNIT ACCUMU- CAPACITY (D. X HT.) REQ'D L-3
(TRAP) (GAS) DRAIN
(IN.) (TRANSFER) (LBS.)
CAT. NO. LATOR (GPM) (IN.) (IN.) TRANSFER
(VENT)
"X"
25 630.377.0050 [email protected]
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
PILOT FLOAT
VALVE
UPPER
EQ.
LINE PILOT LINE-1/4'' NOMINAL LP.
PRESSURE
GAUGE
GAUGE
LOWER VALVE
EQ.
LINE
MIN.
18''
SERIES 700H
PILOT OPERATED
VALVE TO
L-5 CPR
MANUAL
BYPASS
18
630.377.0050 [email protected] 26
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
SYSTEM COMPONENTS
Dump Trap: Pressure vessel rated for -50ºF and 300 PSI, stamped and National Board registered
3-Way Valve: Phillips Series 3000 solenoid-operated 3-way valve, with angle filter (other valve arrangements available for very
large systems)
Check Valves: Phillips Series 600 and 700 flanged in-line disc and piston type check valves as indicated in piping schematics
Service Valves: Hand stop valves as indicated in system piping schematics
Level Control: External float switch (initiates transfer cycle)
Accessories: Level Eyes®, gauge and gauge valve, relief valve, unions, floor flanges (vertical traps)
Control Panel: UL/NEMA4 enclosure with adjustable timer(s), manual transfer switch, mounted cycle counter, alarm selector switch and
pilot light indicators.
ADDITIONAL ITEMS FOR TYPE G SYSTEMS:
Pump: Nikkiso or Teikoku sealless liquid refrigerant pump is standard. Corken centrifugal and magnetic drive pumps available as options.
Pump Relief: A check valve is placed in the bypass line going back to pump suction to prevent deadheading
SEQUENCE OF OPERATIONS
For all types of transfer system, the transfer cycle is initiated when the liquid draining from the suction accumulator reaches the middle of
the upper Level Eye on the dump trap. This signal energizes the 3-way valve changing its operation from vent to hot gas supply. Liquid
is then transferred according to system type:
TYPE T: As liquid starts to transfer, the level in the trap drops causing the float switch to open. This starts the adjustable off-delay cycle
timer. When the cycle times out, the 3-way valve de-energizes and allows the trap to vent back to the accumulator. The timer should be
set so that all liquid is drained past the outlet check valve.
TYPE A: As liquid starts to transfer, the level in the trap drops causing the float switch to open. This starts the adjustable off-delay cycle
timer. When the cycle times out, the 3-way valve de-energizes and allows the trap to vent back to the accumulator. The timer should be
set so that all liquid is drained past the hand valve at the HPR.
TYPE DK: When the 3-way valve is energized so is the interrupting valve, causing it to change from wide open to differential pressure
control. Since the pressure in the hot gas line to the trap is higher than the HPR pressure, the liquid will start to flow out of the trap,
causing the float switch to open. This starts the adjustable off-delay cycle timer. When the cyle times out, the 3-way valve de-energizes,
allowing the trap to vent back to the accumulator and the interrupting valve is de-energized. The timer should be set to drain the liquid
completely past the outlet check valve.
TYPE G: The float switch actuation also starts 2 adjustable on-delay relays, one for the pump and one for pump protection. When the
pump on-delay timer times out, the pump starts and the transfer begins. As liquid starts to transfer, the level in the trap drops causing
the float switch to open. This starts the adjustable off-delay cycle timer. When the cycle timer times out, the pump stops and the 3-way
valve is de-energized, allowing the trap to vent back to the accumulator. The pump on-delay timer must be set to allow time for the trap
to become fully pressurized before the pump starts. The off-delay timer should be set to time out when the liquid level reaches the lower
Level Eye (take care to never let the pump run dry). The pump protection on-delay timer should be set 10-15 seconds longer than the
complete cycle and is meant to stop the pump if the float switch ever sticks open.
INSTALLATION HINTS
ALWAYS mount the inlet check valve as low and close to the dump trap as possible.
On Type A systems, mount the outlet check valve vertically as close to the HPR as possible.
Disc type checks should be mounted in the vertical orientation unless it is absolutely necessary to mount horizontally.
Piston type checks can be mounted in either orientation but horizontal is preferred. It should be mounted below the lower Level Eye on
the trap.
Insulate the dump trap; do not insulate the check valves
Take care to set the timers properly. Adjust the timers as necessary whenever the refrigeration system operating parameters change.
27 630.377.0050 [email protected]
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
FROM
HIGH
SIDE
CONTROL
L1
GAS SUPPLY
(UTILIZED DOWNSTREAM
REGULATOR)
L2
3-WAY
VALVE
HP LP
FILTER
CONTROLLED
PRESSURE
RECEIVER
L1
RELIEF SUCTION
LIQUID
ACCUMULATOR
GAUGE &
LEVEL EYE VALVE
L4
DUMP
TRAP
L3
"Y"
CHECK VALVE V2
24'' MAX.
"X"
ACCUM. SYSTEM DUMP TRAP "Y" IPS LINE SIZES SHIPPING
CATALOG (MIN REQ'D, IN.)
CAP CAPACITY DIA x LNG (REF.) WEIGHT
NUMBER* L1 L2 L3 L4
(TONS) (GPM) (IN.) VERT. HOR. (IN.) (LBS.)
VENT GAS TRANSFER DRAIN
T187V/H** 140 3.7 12 x 26 30 25 10 ¾ ¾ ¾ 1¼ 270
T287V/H 240 6.1 12 x 26 30 25 10 ¾ ¾ ¾ 1½ 285
T387V/H 440 10.9 16 x 38 40 30 11 ¾ ¾ 1¼ 2 430
T487V/H 760 19.1 20 x 40 46 35 13 1¼ 1¼ 1¼ 3 670
T587V/H 1480 31.2 24 x 42 47 42 16 1¼ 1¼ 2 4 810
T687H 2000 56.5 24 x 72 SP. 42 16 1¼ 1¼ 3 4 1180
T787H 3000 73.4 24 x 84 SP. 42 16 2 1¼ 3 4 (2) 1630
Ordering Instructions:
* When ordering, specify suffix "V" (for vertical dump trap) or suffix "H" (for horizontal dump trap).
** Do not use 187 size systems when accumulator suction temperature is below 0°F. Upsize to 287 system.
If system is to be used for Halocarbon refrigerant, use 1/4 of the tonnage ratings shown for R-717.
Add an "F" in front of the Catalog Number. Seal cap valves and accessories will be furnished.
18
630.377.0050 [email protected] 28
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
DISCHARGE LINE
L1
L2
3-WAY
VALVE
LP HP
FILTER
RELIEF
GAUGE &
VALVE
FLOAT SWITCH
L4
DUMP
TRAP
SUCTION
ACCUMULATOR CHECK VALVE V1
MOUNT LOW AND
CLOSE TO DUMP
TRAP
"X" L3
"X/3"
CHECK VALVE V2
MAX. 24'' MOUNT CLOSE TO
RECEIVER
CL
HIGH PRESSURE
RECEIVER
"X"
ACCUM. SYSTEM DUMP TRAP (MIN REQ'D) IPS LINE SIZES SHIPPING
CATALOG
CAP CAPACITY DIA x LNG (IN.) WEIGHT
NUMBER*
(TONS) (GPM) (IN.) L1 L2 L3 L4 (LBS.)
VERT. HOR.
VENT GAS SUPPLY TRANSFER DRAIN
A187V/H** 100 2.7 12 x 26 38 28 ¾ ¾ 1¼ 1¼ 270
A287V/H 200 6.7 12 x 26 40 30 ¾ ¾ 1½ 1½ 285
A387V/H 300 7.5 16 x 38 55 36 ¾ ¾ 2 2 450
A487V/H 800 20.2 20 x 40 62 45 1¼ 1¼ 3 3 700
A587V/H 1320 33.3 24 x 42 70 55 1¼ 1¼ 4 4 850
Ordering Instructions:
* When ordering, specify suffix "V" (for vertical dump trap) or suffix "H" (for horizontal dump trap)
** Do not use 187 size systems when accumulator suction temperature is below 0°F. Upsize to 287 system.
If system is to be used for a Halocarbon refrigerant, use 1/4 of the tonnage ratings shown for R-717.
Add an "F" in front of the Catalog Number. Seal cap valves and accessories will be furnished.
29 630.377.0050 [email protected]
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
DISCHARGE LINE
L1
L2
3-WAY
VALVE
LP HP
FILTER
RELIEF
L3
LEVEL EYE
GAUGE & VALVE
L4
DUMP
TRAP
SUCTION HIGH
ACCUMULATOR PRESSURE
CHECK VALVE V1 RECEIVER
MOUNT LOW AND
CLOSE TO DUMP
"X" TRAP
"Y"
CHECK VALVE 2
24" MAX.
ACCUM. SYSTEM DUMP TRAP "X" "Y" IPS LINE SIZES SHIPPING
CATALOG
CAP CAPACITY DIA x LNG (REF.) L1 L2 L3 L4 WEIGHT
NUMBER* VERT. HOR.
(TONS) (GPM) (IN.) (IN.) VENT GAS TRANSFER DRAIN (LBS.)
DK187V/H** 120 3 12 x 26 30 25 10 ¾ ¾ ¾ 1¼ 270
DK287V/H 200 5.1 12 x 26 30 25 10 ¾ ¾ ¾ 1½ 285
DK387V/H 360 9.1 16 x 38 40 30 11 ¾ ¾ 1¼ 2 430
DK487V/H 560 14.2 20 x 40 46 35 13 1¼ 1¼ 1¼ 3 670
DK587V/H 1160 29.2 24 x 42 47 42 16 1¼ 1¼ 2 4 810
Ordering Instructions:
Order "DK" system based on accumulator tonnage.
* When ordering, specify the suffix "V" (for vertical dump trap) or suffix "H" (for horizontal dump trap).
** Do not use 187 size systems when accumulator suction temperature is below 0°F. Upsize to 287 system.
If system is to be used for Halocarbon refrigerant, use 1/4 of the tonnage ratings shown for R-717.
Add an "F" in front of the Catalog Number. Seal cap valves and accessories will be furnished.
INTERRUPTING VALVES FOR
DK SYSTEMS
VALVE PLANT SHIPPING
PIPE SIZE
CATALOG TONS WEIGHT
(IPS)
NUMBER (R717) (LBS.)
ICR40BL 80 1½ ; 2 40
ICR50BL 140 2 55
ICR65BL 320 3 175
ICR80BL 640 4 265
ICR100BL 1160 5 380
ICR125BL 1800 6 400
*Interrupting valve sold separately
Ordering Instructions:
Order interrupting valve based on tonnage of the discharge line to be used for its installation.
Never use an interrupting valve that is more than one pipe size smaller than the usable discharge line.
18
630.377.0050 [email protected] 30
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
RELIEF
GAUGE &
VALVE
L1 DISCHARGE LINE
PUMP
MOTOR
COOLING
LINE
L2
RELIEF PIPING DETAIL
3-WAY
VALVE
LP HP
L3
RELIEF
GAUGE &
VALVE
MOTOR
COOLING
LINE
LEVEL EYE
CHECK
50 PSID VALVE
V2
CHECK HIGH
DUMP VALVE
PRESSURE
SUCTION CHECK VALVE V1
MOUNT LOW AND
TRAP RECEIVER
ACCUMULATOR CLOSE TO DUMP
TRAP
"X"
3/4''
LIQUID
"Y" L5 V3
AMMONIA
PUMP
STRAINER
24'' MAX.
Ordering Instructions:
* When ordering, specify suffix "V" (for vertical dump trap) or suffix "H" (for horizontal dump trap)
** Do not use 187 size systems when accumulator suction temperature is below 0°F. Upsize to 287 system.
If system is to be used for a Halocarbon refrigerant, use 1/4 of the tonnage ratings shown for R-717.
Add an "F" in front of the Catalog Number. Seal cap valves and accessories will be furnished.
The standard wired control panel is 120 Volt control; motors are 460/3/60 voltage.
The standard Nikkiso or Teikoku pump furnished with the systems above is a sealless hermetic pump, and operates to a minimum temperature of -50°F.
Corken centrifugal and magnetic drive pumps are optional. Optional pumps may require changes to piping schematic.
31 630.377.0050 [email protected]
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
Standard
StandardFeatures:
Standard Features:
Features:
250#250#ASME
•250# ASMERecirculator
ASME RecirculatorVessel,
Recirculator Vessel,National
Vessel, NationalBoard
National BoardListed,
Board Listed,custom
Listed, customdesigned
custom designedto
designed totomeet
meetliquid-vapor
meet liquid-vaporseparation
liquid-vapor separationand
separation andsurge
and surgerequirements
surge requirements
requirements
300#300#ASME
•300# ASME Oil
OilPot,
Pot, fully
fullytrimmed
trimmed
ASME Oil Pot, fully trimmed and piped and
and piped
piped
Valved
Valvedand
•Valved andflanged
and flangedlevel
flanged levelcolumn
level columnwith
column with55 5Phillips
with PhillipsLevel
Phillips LevelEye
Level Eyesight
Eye sightglasses,
sight glasses,mounted
glasses, mountedhigh
mounted highlevel
high levelfloat
level floatswitch
float switchand
switch anddrain
and drainvalve
drain valve
valve
Customer's
Customer'schoice
•Customer's choice ofofpump
pump manufacturer/type,
manufacturer/type, selected
selected for "standard"
for "standard" 30 30
choice of pump manufacturer/type, selected for "standard" 30 psid and 3:1 recirculationpsid and
psid and 3:13:1recirculation
recirculation
Nikkiso
• NikkisoSealless
Nikkiso Sealless
Sealless
Teikoku
• TeikokuSealless
Teikoku Sealless
Sealless
Cornell
• CornellCB
Cornell CBCBOpen-Drive
Open-Drive
Open-Drive
Cornell
• CornellHT
Cornell HTHTHermetic
Hermetic
Hermetic
DualDualrelief
•Dual reliefassembly
relief assemblyfor
assembly forformain
mainrecirculator
main recirculatorvessel,
recirculator vessel,single
vessel, singlerelief
single reliefvalve
relief valvefor
valve foroil
for oiloilpot
pot pot
Piping
• Pipingcomplete
Piping complete with pump suction service valves, discharge stop and check
complete with
with pumppump suction
suction service
service valves,
valves,discharge
discharge stop
stopand
and checkvalves,
check valves,bypass
valves, bypasshand
bypass handexpansion
hand expansionvalves,
expansion valves,pump
valves, pumprelief
pump reliefregulators
relief regulators
regulators
and
andmotor
and motorcooling
motor coolingrecirculation
cooling recirculationvalves
recirculation valves(sealless
valves (seallesspumps)
(sealless pumps)or
pumps) ororvolute
volutevent
volute ventvalves
vent valves(open-drive
valves (open-drivepumps)
(open-drive pumps)
pumps)
• Weldedstructural
Welded structuralsteel
steelbasebase
Welded structural steel base
• Stopvalves
Stop valvesare areDanfoss,
Danfoss,check checkvalves
valvesare areH.A.
H.A.Phillips
Phillips
Stop valves are Danfoss, check valves are H.A. Phillips
1•1 1coat PS
coat PSX X7 00
7 00Siloxane
Siloxane
coat PSX 700 Siloxane
Common
CommonOptional
Common OptionalEquipment
Optional Equipment
Equipment
Level
LevelControl:
Control:
Level Control:
• Multiple
Multiplefloat
Multiple floatswitches
float switchesfor
switches forforlow
lowlevel,
low level,operating
level, operatinglevel
operating leveland
level andupper
and upperlevel
upper level
level
• Level
Levelprobe
probe
Level probe
• Electronic
Electroniccontroller
Electronic controllerto
controller totointerpret
interpretprobe
interpret probesignal
probe signal
signal
Liquid
LiquidMakeup
Makeup
Liquid Makeup:
• Phillips
Phillipsmodulating
Phillips modulatinglow-side
modulating low-sidecontrol
low-side control
control
• Conventional solenoid valve
Conventional
Conventional solenoid
solenoid valvewith
valve withstrainer
with strainerand
strainer andhand
and handexpansion
hand expansionvalve
expansion valvewith
valve withhand
with handexpansion
hand expansionvalve
expansion valvebypass
valve bypassloop
bypass loop
loop
• Motorized
Motorizedvalve
Motorized valvewith
valve withsolenoid
with solenoidfor
solenoid forpower
for powerfailure
power failureprotection,
failure protection,with
protection, withhand
with handexpansion
hand expansionbypass
expansion bypassloop
bypass loop
loop
Danfoss
DanfossICF ICFpackaged
packagedvalve valvestation
station
• Danfoss ICF packaged valve station
Pulse-width
Pulse-width
Pulse-width control
control valve
control valve
valve with
with
with hand
handexpansion
hand expansionvalve
expansion valvebypass
valve bypassloop
bypass loop
loop
•
Control
Control Panel: UL/NEMA 4 rated with main power disconnect, pump
ControlPanel:
Panel: UL/NEMA
UL/NEMA 4 rated
4 ratedwith
withmain
main power
power disconnect,
disconnect, pumpstarters
pump startersand
starters andswitches,
and switches,alarm
switches, alarmhorn
alarm horn&
horn &&silence
silence(ships
silence (shipsloose)
(ships loose)
loose)
Other
OtherAvailable
Other AvailableOptions:
Available Options:
Options:
Post
PostWeld
Weld Heat
Heat Treatment
Treatment
• Post Weld Heat Treatment
Vessel
VesselPressure
Pressureratingsratingsother
otherthan
than250
250PSIG
PSIG
• Vessel Pressure ratings other than 250 PSIG
Oil
Oilpot
pot heater:
heater: 1.5kW
1.5kW or 2kW
or 2kW with
withintegral
integral
• Oil pot heater: 1.5kW or 2kW with integral thermostat
thermostat
thermostat
• Pump
Pumprequirements
Pump requirementsother
requirements otherthan
other than30
than 3030psid
psidor
psid oror3:1
3:1recirculation
3:1 recirculation
recirculation
• Valve
Valvepackages
Valve packagesusing
packages usingmanufacturers
using manufacturersother
manufacturers otherthan
other thanDanfoss
than Danfossor
Danfoss ororPhillips
Phillips
Phillips
• Low
Lowtemperature
Low temperaturepiping
temperature pipingcomponents
piping componentswhen
components whennecessary
when necessary-- will
necessary willuse
-will use
use
ASME
ASMEB31.5
ASME B31.5low
B31.5 lowtemp
low temppipe
temp pipeexemption
pipe exemptionwhen
exemption whenallowed
when allowed
allowed
• Control
ControlPanel
Control Paneladditional
Panel additionalitems:
additional items:run-time
items: run-timecounters,
run-time counters,mounted
counters, mountedprobe
mounted probe
probe
controller,
controller,oil
controller, oiloilpot
pot potheater
heatercontrol
heater control
control
Factory
Factorywiring
wiring
• Factory wiring
Sandblasting
Sandblasting
• Sandblasting
Special
Specialpaint
• Special paint
paint
18
630.377.0050 [email protected] 32
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
G F
HLCO
OP LEVEL
LLCO
(2'' FROM
SEAM)
N I
M
L
J
E D
A B C D E F G H I J K L M N O
Pump
Model Base Base Wet Dry Pump Oil Pot Oil Pot OP
OD OAH Pkg Ht Liq. Feed Relief Vent/ Bypass Oil Pot LLCO* HLCO*
Number Width Length Suction Suction Suction Drain† Vent Level*
Cooling
PVR24 24 113 179 42 75 6 5 1¼ 4 1 ¾ ¾ ¾ ¾ 8 x 36 2 16 73
PVR30 30 116 182 55 75 8 6 1½ 4 1 ¾ ¾ ¾ ¾ 8 x 36 2 16 69
PVR36 36 119 185 65 84 8 6 2 4 1 ¾ ¾ ¾ ¾ 8 x 36 2 16 69
PVR42 42 146 214 55 85 10 8 2½ 4 1 ¾ ¾ ¾ ¾ 8 x 36 2 16 87
PVR48 48 149 215 62 90 10 10 2½ 4 1 ¾ ¾ ¾ ¾ 8 x 36 2 16 84
PVR54 54 152 221 68 96 12 10 3 5 1 ¾ ¾ ¾ ¾ 8 x 36 2 16 81
PVR60 60 155 223 72 96 12 12 3 5 1¼ ¾ ¾ ¾ 1 10 x 36 2 16 78
PVR72 72 161 227 78 112 16 14 4 6 1¼ ¾ ¾ ¾ 1 10 x 36 2 16 69
PVR84 84 167 233 98 124 18 16 5 8 1½ ¾ 1 ¾ 1¼ 12 x 36 2 16 63
PVR96 96 173 239 102 128 20 18 5 8 1½ ¾ 1 ¾ 1¼ 12 x 36 2 16 70
PVR108 108 179 245 114 132 20 20 6 10 1½ 1 1 ¾ 1¼ 12 x 36 2 16 70
PVR120 120 185 251 126 132 24 24 6 10 1½ 1 1 ¾ 1½ 12 x 36 2 16 62
PVR144 144 197 263 150 156 24 24 8 12 1½ 1¼ 1 ¾ 1½ 12 x 36 2 16 62
* Dimensions are taken from lower head/shell seam.
†For temperatures below -20° oil drain size is 1-1/2''
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
33 630.377.0050 [email protected]
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
B
G
K H
A HLCO
L OP LEVEL
LLCO
BTM. OF VESS.
E
J C
M N I
120 D
A B C D E F G H I J K L M N O
Pump
Model Base Wet Dry Pump Oil Pot Oil Pot OP
OD OAL Pkg Ht Sump Liq. Feed Relief Vent/ Bypass Oil Pot LLCO* HLCO*
Number Width Suction Suction Suction Drain† Vent LEVEL*
Cooling
PHR24 24 137 90 60 4 x 12 6 5 1-1/4 4 1 3/4 3/4 3/4 3/4 8 x 36 4 6 12
PHR30 30 140 96 60 4 x 12 8 6 1-1/2 4 1 3/4 3/4 3/4 3/4 8 x 36 4 7 15
PHR36 36 143 102 60 4 x 12 8 6 1-1/2 4 1 3/4 3/4 3/4 3/4 8 x 36 4 8 18
PHR42 42 146 110 62 4 x 12 10 8 2 4 1 3/4 3/4 3/4 3/4 8 x 36 6 10 21
PHR48 48 149 116 65 4 x 12 10 8 2-1/2 4 1 3/4 3/4 3/4 3/4 8 x 36 6 11 24
PHR54 54 152 120 72 4 x 12 10 10 2-1/2 4 1 3/4 3/4 3/4 1 8 x 36 6 12 27
PHR60 60 155 126 72 4 x 12 12 10 3 5 1-1/4 3/4 3/4 3/4 1 10 x 36 6 13 30
PHR72 72 161 138 84 4 x 12 14 12 4 6 1-1/4 3/4 3/4 3/4 1 10 x 36 8 16 36
PHR84 84 167 156 96 4 x 12 16 16 4 8 1-1/2 3/4 1 3/4 1 12 x 36 8 18 42
PHR96 96 173 168 96 4 x 12 18 16 5 8 1-1/2 3/4 1 3/4 1-1/4 12 x 36 8 20 48
PHR108 108 179 180 96 4 x 12 20 18 5 8 1-1/2 1 1 3/4 1-1/4 12 x 36 8 21 54
PHR120 120 185 192 108 4 x 12 24 20 6 10 1-1/2 1 1 3/4 1-1/2 12 x 36 8 23 60
PHR144 144 197 216 120 4 x 12 24 24 8 12 1-1/2 1-1/4 1 3/4 1-1/2 12 x 36 8 27 72
* Dimensions are taken from bottom of vessel
†For temperatures below -20° oil drain size is 1-1/2''
All vessels are custom-built to customer specifications. Vessel dimensions, shipping weights and nozzle sizes in tables are suggestions for nominal conditions.
18
630.377.0050 [email protected] 34
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
Phillips offers packaging of plate and frame-type heat exchangers. We can supply the complete package, or you can have the manufacturer
of the heat exchanger ship it to our factory for packaging. Have our expert fitters do the packaging in a controlled factory environment.
STANDARD OFFERING
The standard packaging includes the following:
Split-flow horizontal surge drum (see ratings on page 2, vessel design on page 17)
Dual relief assembly for package (ships loose)
Oil Pot with full trim (relief ships loose)
Valved and flanged level column with Level Eye® sight glasses and factory installed HLCO float switch and drain valve
Danfoss level sensor and controller
Danfoss shutoff valves
Structural steel base
1 coat PSX 700 Silox ane
OPTIONS
Liquid makeup valve train
• Solenoid control with hand expansion bypass loop
• Motorized valve with solenoid power-loss protection, with hand expansion bypass loop
• Danfoss ICF valve station
Electric oil pot heater with integral thermostat, in various voltages and kw
Stop valves to isolate PHE
Dual relief assembly for PHE
Post weld heat treatment of surge drum
Sandblasting and special coatings
Alternate level sensors and controllers (Hansen, R/S, others)
Alternate valve suppliers (Hansen, R/S, others)
UL/NEMA4 Control Panel
When requesting quote, please indicate PHE selection details (tonnage, suction temperature, and dimensions), as well as desired options.
35 630.377.0050 [email protected]
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
Ref
18
630.377.0050 [email protected] 36
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
Support
Height Floor
37 630.377.0050 [email protected]
Distributor -Since 1993-
VALVES • VESSELS • SYSTEMS • CONTROLS
Note:
Ref Sketch any
baffles or
Support internals on
Height Floor Drawing.
18
630.377.0050 [email protected] 38
Distributor -Since 1993-
Check Out Our Valves & Accessories Catalog!
HHee ee
oo ......
C
C
PS RREEFFRRIG
IGEERRAATTIION
VVAALLVVEESON
s oo
l Co
l Co ls s i ihh
oo AA s si o
s s llll lolo i o l l Po
l Posi o
s si i Ho Ho i o
s oo
l Co
l Co ls s i ihh
oo AA s si o
s s llll lolo i o l l Po
l Posi o
S&
s si i Ho Ho i o
PHILLIPS REFRIGERATION
& AA EESSSO
SORRIIEESS
-011
-1 EE-0
t n
l Ref ee t n
e InIn usust t l Re1f 993--
-S-Snn ee 1993 || -1
NN ththAm
Ame ut
b t ll
ssss eess t
st ut
DD st b
& A
A e
e
es &
. | VV ll es
. A . P
P h
hil
illilippss&&CCoo. |
HH. A.
C
M Po s
gis
SM "U" o l o SM "R" B V SO 9 :2