RCD Computations
RCD Computations
Column Height 4
Span Length 1 : 8.00 m ; 3.20 m Note : This is designed for 7-span frame. In case of
Span Length 2 : 6.00 m Column Height 3 : 3.20 m lesser span, the second to the last column
Span Length 3 : 6.00 m Column Height 2 : 3.20 m frame and upper is not included. Just look
Span Length 4 : 5.00 m Column Height 1 : 3.20 m at the horizontal force, if there is negative,
Span Length 5 : 5.00 m that column frame is not included.
Span Length 6 : 8.70 m
Span Length 7 : 8.00 m
Span Length 8 : 3.30 m ` No. of Spans : 8
#REF!
#REF!
#REF!
#REF!
1.09 3.26
2.17 1.09
3.26
6.52 3.26
5.43
15.20 7.60
DESIGN OF TWO
Given:
short side A: 5.575 m fc' = 28 mPa
long side B: 5.7 m fy = 420 mPa
f = 0.9
LOADS: f = 0.85
live load: 1.9 kPa conc. unit wt.= 23.5 kN/m3
floorduct
finish: 0.77 kPa CA = 0.047 using 12
mech.
ceiling
allowance finish: 0.578 kPa CADL = 0.019 cover = 20
0.2 kPa CALL = 0.028
electrical load 0.023 kPa CB = 0.043 Ad =
partition load: 0.53 kPa CBDL = 0.017
scellaneous load: 0.5 kPa CBLL = 0.026
SOLUTION:
5.58
ratio m = = 0.979 > 0.500 Two-way Slab!
5.70
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.17 ) ( 23.5 ) = 4.00 kPa
floor finish = 0.77 kPa
ceiling finish = 0.578 kPa
mech. duct allowance = 0.2 kPa
electrical load = 0.023 kPa
partition load = 0.53 kPa
miscellaneous loads = 0.5 kPa
6.60 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2 ( 6.60 ) = 7.915 kPa
WULL = 1.6 (LL) = 1.6 ( 1.9 ) = 3.04 kPa
WU = WUDL + WULL = 10.955 kPa
at midspan
MADL = (WuDL) (CADL) (A2)
= 4.674 kN-m
MALL = (WuLL) (CALL) (A2)
= 2.646 kN-m
MA = MADL + MALL = 7.320 kN-m
at midspan
MBDL = (WuDL) (CBDL) (B2)
= 4.372 kN-m
MBLL = (WuLL) (CBLL) (B2)
= 2.568 kN-m
MB = MBDL + MBLL = 6.940 kN-m
Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 16.003 x 10e6
Rn = = = 0.858 MPa
fbd 1
2
0.90 x 1000 x (144 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.858
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
when rmin > r < rmax
Therefore, use 0.00333 for As
As = f b d1
= ( 0.00333 ) ( 1000 ) ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
at midspan
MA 7.320 x 10e6
Rn = = = 0.392 MPa
f b d12 0.90 x 1000 x (144 ) 2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.392
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ) ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.976
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ) ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
at midspan
MB 6.940 x 10e6
Rn = = = 0.443 MPa
fbd 2
2
0.90 x 1000 x (132 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.443
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ) ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
Smax = 2h = 2 ( 170 ) = 340 mm or 450 mm
Therefore, Smax = 340 mm
RESULTING TABLE
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab dimensions
concrete stress and strain
mm type of loading
miscellaneous dead loads
rebars diameter and concrete cover
mm constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
beam dimensions.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
5. Having discontinuous edge will depend upon the case of the slab.
As seen on the table, depends on slab's case.
0.00208
0.00333
0.02064
0.00094
0.00333
0.02064
0.00237
0.00333
0.02064
0.00106
0.00333
0.02064
340
340
500
370
370
500
able design.
ract the supporting
Given:
short side A: 4.7 m fc' = 28 mPa
long side B: 5.575 m fy = 420 mPa
f = 0.9
LOADS: f = 0.85
live load: 1.9 kPa conc. unit wt.= 23.5 kN/m3
floorduct
finish: 0.77 kPa CA = 0.061 using 12
mech.
ceiling
allowance finish: 0.578 kPa CADL = 0.024 cover = 20
0.2 kPa CALL = 0.038
electrical load 0.023 kPa CB = 0.03 Ad =
partition load: 0.53 kPa CBDL = 0.012
scellaneous load: 0.5 kPa CBLL = 0.019
SOLUTION:
4.70
ratio m = = 0.842 > 0.500 Two-way Slab!
5.58
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.17 ) ( 23.5 ) = 4.00 kPa
floor finish = 0.77 kPa
ceiling finish = 0.578 kPa
mech. duct allowance = 0.2 kPa
electrical load = 0.023 kPa
partition load = 0.53 kPa
miscellaneous loads = 0.5 kPa
6.60 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2 ( 6.60 ) = 7.915 kPa
WULL = 1.6 (LL) = 1.6 ( 1.9 ) = 3.04 kPa
WU = WUDL + WULL = 10.955 kPa
Solving for Moments:
A. Short Span, Middle Strip
at continuous edge
MA = (Wu) (CA) (A2)
= 14.762 kN-m
at midspan
MADL = (WuDL) (CADL) (A2)
= 4.196 kN-m
MALL = (WuLL) (CALL) (A2)
= 2.552 kN-m
MA = MADL + MALL = 6.748 kN-m
at midspan
MBDL = (WuDL) (CBDL) (B2)
= 2.952 kN-m
MBLL = (WuLL) (CBLL) (B2)
= 1.795 kN-m
MB = MBDL + MBLL = 4.747 kN-m
Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 14.762 x 10e6
Rn = = = 0.791 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.791
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
at midspan
MA 6.748 x 10e6
Rn = = = 0.362 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.362
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.651
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
at midspan
MB 4.747 x 10e6
Rn = = = 0.303 MPa
fbd 2
2
0.90 x 1000 x (132 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.303
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
RESULTING TABLE
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab dimensions
concrete stress and strain
mm type of loading
miscellaneous dead loads
rebars diameter and concrete cover
mm constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
beam dimensions.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
5. Having discontinuous edge will depend upon the case of the slab.
As seen on the table, depends on slab's case.
0.00192
0.00333
0.02064
0.00087
0.00333
0.02064
0.00157
0.00333
0.02064
0.00073
0.00333
0.02064
Column Strip
S (mm)
340 340
340 340
340 500
340 370
340 370
340 500
onable design.
ubtract the supporting
e of the slab.
DESIGN OF TW
Given:
short side A: 4.7 m fc' = 28 mPa
long side B: 5.575 m fy = 420 mPa
f = 0.9
LOADS: f = 0.85
live load: 1.9 kPa conc. unit wt.= 23.5 kN/m3
floorduct
finish: 0.77 kPa CA = 0.072 using 12
mech.
ceiling
allowance finish: 0.578 kPa CADL = 0.028 cover = 20
0.2 kPa CALL = 0.039
electrical load 0.023 kPa CB = 0.02 Ad =
partition load: 0.53 kPa CBDL = 0.013
scellaneous load: 0.5 kPa CBLL = 0.02
SOLUTION:
4.70
ratio m = = 0.842 > 0.500 Two-way Slab!
5.58
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.17 ) ( 23.5 ) = 4.00 kPa
floor finish = 0.77 kPa
ceiling finish = 0.578 kPa
mech. duct allowance = 0.2 kPa
electrical load = 0.023 kPa
partition load = 0.53 kPa
miscellaneous loads = 0.5 kPa
6.60 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2 ( 6.60 ) = 7.915 kPa
WULL = 1.6 (LL) = 1.6 ( 1.9 ) = 3.04 kPa
WU = WUDL + WULL = 10.955 kPa
Solving for Moments:
A. Short Span, Middle Strip
at continuous edge
MA = (Wu) (CA) (A2)
= 17.424 kN-m
at midspan
MADL = (WuDL) (CADL) (A2)
= 4.896 kN-m
MALL = (WuLL) (CALL) (A2)
= 2.619 kN-m
MA = MADL + MALL = 7.515 kN-m
at midspan
MBDL = (WuDL) (CBDL) (B2)
= 3.198 kN-m
MBLL = (WuLL) (CBLL) (B2)
= 1.890 kN-m
MB = MBDL + MBLL = 5.088 kN-m
Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 17.424 x 10e6
Rn = = = 0.934 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.934
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
at midspan
MA 7.515 x 10e6
Rn = = = 0.403 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.403
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.434
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
at midspan
MB 5.088 x 10e6
Rn = = = 0.324 MPa
fbd 2
2
0.90 x 1000 x (132 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.324
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
RESULTING TABLE
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab dimensions
concrete stress and strain
mm type of loading
miscellaneous dead loads
rebars diameter and concrete cover
mm constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
beam dimensions.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
5. Having discontinuous edge will depend upon the case of the slab.
As seen on the table, depends on slab's case.
0.00227
0.00333
0.02064
0.00097
0.00333
0.02064
0.00104
0.00333
0.02064
0.00078
0.00333
0.02064
Column Strip
S (mm)
340 340
340 340
340 500
340 370
340 370
340 500
onable design.
ubtract the supporting
e of the slab.
DESIGN OF
Given:
short side A: 5.575 m fc' = 28 mPa
long side B: 7.7 m fy = 420 mPa
f = 0.9
LOADS: f = 0.85
live load: 1.9 kPa conc. unit wt.= 23.5 kN/m3
floorduct
finish: 0.77 kPa CA = 0.08 using 12
mech.
ceiling
allowance finish: 0.578 kPa CADL = 0.032 cover = 20
0.2 kPa CALL = 0.048
electrical load 0.023 kPa CB = 0.012 Ad =
partition load: 0.53 kPa CBDL = 0.006
scellaneous load: 0.5 kPa CBLL = 0.012
SOLUTION:
5.58
ratio m = = 0.725 > 0.500 Two-way Slab!
7.70
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.17 ) ( 23.5 ) = 4.00 kPa
floor finish = 0.77 kPa
ceiling finish = 0.578 kPa
mech. duct allowance = 0.2 kPa
electrical load = 0.023 kPa
partition load = 0.53 kPa
miscellaneous loads = 0.5 kPa
6.60 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2 ( 6.60 ) = 7.915 kPa
WULL = 1.6 (LL) = 1.6 ( 1.9 ) = 3.04 kPa
WU = WUDL + WULL = 10.955 kPa
at midspan
MADL = (WuDL) (CADL) (A2)
= 7.872 kN-m
MALL = (WuLL) (CALL) (A2)
= 4.535 kN-m
MA = MADL + MALL = 12.408 kN-m
at midspan
MBDL = (WuDL) (CBDL) (B2)
= 2.816 kN-m
MBLL = (WuLL) (CBLL) (B2)
= 2.163 kN-m
MB = MBDL + MBLL = 4.979 kN-m
Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 27.240 x 10e6
Rn = = = 1.460 MPa
fbd 1
2
0.90 x 1000 x (144 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 1.460
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
when rmin < r < rmax
Therefore, use 0.00359 for As
As = f b d1
= ( 0.00359 ) ( 1000 ( 144 )
= 516.797984962 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 218.84760253 mm
As 516.797984962
say S = 210 mm
at midspan
MA 12.408 x 10e6
Rn = = = 0.665 MPa
f b d12 0.90 x 1000 x (144 ) 2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.665
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.497
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
at midspan
MB 4.979 x 10e6
Rn = = = 0.317 MPa
fbd 2
2
0.90 x 1000 x (132 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.317
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
Smax = 2h = 2 ( 170 ) = 340 mm or 450 mm
Therefore, Smax = 340 mm
RESULTING TABLE
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab dimensions
concrete stress and strain
mm type of loading
miscellaneous dead loads
rebars diameter and concrete cover
mm constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
beam dimensions.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
5. Having discontinuous edge will depend upon the case of the slab.
As seen on the table, depends on slab's case.
0.00359
0.00333
0.02064
0.00161
0.00333
0.02064
0.00120
0.00333
0.02064
0.00076
0.00333
0.02064
Column Strip
S (mm)
310 310
340 340
340 500
340 370
340 370
340 500
onable design.
ubtract the supporting
e of the slab.
DESIGN OF TW
Given:
short side A: 4.7 m fc' = 28 mPa
long side B: 5.95 m fy = 420 mPa
f = 0.9
LOADS: f = 0.85
live load: 1.9 kPa conc. unit wt.= 23.5 kN/m3
floorduct
finish: 0.77 kPa CA = 0.076 using 12
mech.
ceiling
allowance finish: 0.578 kPa CADL = 0.029 cover = 20
0.2 kPa CALL = 0.043
electrical load 0.023 kPa CB = 0.016 Ad =
partition load: 0.53 kPa CBDL = 0.009
scellaneous load: 0.5 kPa CBLL = 0.016
SOLUTION:
4.70
ratio m = = 0.790 > 0.500 Two-way Slab!
5.95
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.17 ) ( 23.5 ) = 4.00 kPa
floor finish = 0.77 kPa
ceiling finish = 0.578 kPa
mech. duct allowance = 0.2 kPa
electrical load = 0.023 kPa
partition load = 0.53 kPa
miscellaneous loads = 0.5 kPa
6.60 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2 ( 6.60 ) = 7.915 kPa
WULL = 1.6 (LL) = 1.6 ( 1.9 ) = 3.04 kPa
WU = WUDL + WULL = 10.955 kPa
Solving for Moments:
A. Short Span, Middle Strip
at continuous edge
MA = (Wu) (CA) (A2)
= 18.392 kN-m
at midspan
MADL = (WuDL) (CADL) (A2)
= 5.071 kN-m
MALL = (WuLL) (CALL) (A2)
= 2.888 kN-m
MA = MADL + MALL = 7.958 kN-m
at midspan
MBDL = (WuDL) (CBDL) (B2)
= 2.522 kN-m
MBLL = (WuLL) (CBLL) (B2)
= 1.722 kN-m
MB = MBDL + MBLL = 4.244 kN-m
Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 18.392 x 10e6
Rn = = = 0.986 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.986
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
at midspan
MA 7.958 x 10e6
Rn = = = 0.426 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.426
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.396
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
at midspan
MB 4.244 x 10e6
Rn = = = 0.271 MPa
fbd 2
2
0.90 x 1000 x (132 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.271
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
RESULTING TABLE
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab dimensions
concrete stress and strain
mm type of loading
miscellaneous dead loads
rebars diameter and concrete cover
mm constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
beam dimensions.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
5. Having discontinuous edge will depend upon the case of the slab.
As seen on the table, depends on slab's case.
0.00240
0.00333
0.02064
0.00102
0.00333
0.02064
0.00095
0.00333
0.02064
0.00065
0.00333
0.02064
Column Strip
S (mm)
340 340
340 340
340 500
340 370
340 370
340 500
onable design.
ubtract the supporting
e of the slab.
DESIGN OF TW
Given:
short side A: 5.95 m fc' = 28 mPa
long side B: 7.7 m fy = 420 mPa
f = 0.9
LOADS: f = 0.85
live load: 1.9 kPa conc. unit wt.= 23.5 kN/m3
floorduct
finish: 0.77 kPa CA = 0.077 using 12
mech.
ceiling
allowance finish: 0.578 kPa CADL = 0.03 cover = 20
0.2 kPa CALL = 0.044
electrical load 0.023 kPa CB = 0.015 Ad =
partition load: 0.53 kPa CBDL = 0.008
scellaneous load: 0.5 kPa CBLL = 0.015
SOLUTION:
5.95
ratio m = = 0.773 > 0.500 Two-way Slab!
7.70
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.17 ) ( 23.5 ) = 4.00 kPa
floor finish = 0.77 kPa
ceiling finish = 0.578 kPa
mech. duct allowance = 0.2 kPa
electrical load = 0.023 kPa
partition load = 0.53 kPa
miscellaneous loads = 0.5 kPa
6.60 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2 ( 6.60 ) = 7.915 kPa
WULL = 1.6 (LL) = 1.6 ( 1.9 ) = 3.04 kPa
WU = WUDL + WULL = 10.955 kPa
Solving for Moments:
A. Short Span, Middle Strip
at continuous edge
MA = (Wu) (CA) (A2)
= 29.864 kN-m
at midspan
MADL = (WuDL) (CADL) (A2)
= 8.407 kN-m
MALL = (WuLL) (CALL) (A2)
= 4.735 kN-m
MA = MADL + MALL = 13.142 kN-m
at midspan
MBDL = (WuDL) (CBDL) (B2)
= 3.754 kN-m
MBLL = (WuLL) (CBLL) (B2)
= 2.704 kN-m
MB = MBDL + MBLL = 6.458 kN-m
Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 29.864 x 10e6
Rn = = = 1.600 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 1.600
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00395 ) ( 1000 ( 144 )
= 568.443567219 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 198.96434144 mm
As 568.443567219
say S = 190 mm
at midspan
MA 13.142 x 10e6
Rn = = = 0.704 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.704
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.621
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
at midspan
MB 6.458 x 10e6
Rn = = = 0.412 MPa
fbd 2
2
0.90 x 1000 x (132 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.412
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
RESULTING TABLE
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab dimensions
concrete stress and strain
mm type of loading
miscellaneous dead loads
rebars diameter and concrete cover
mm constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
beam dimensions.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
5. Having discontinuous edge will depend upon the case of the slab.
As seen on the table, depends on slab's case.
0.00395
0.00333
0.02064
0.00170
0.00333
0.02064
0.00150
0.00333
0.02064
0.00099
0.00333
0.02064
Column Strip
S (mm)
280 280
340 340
340 500
340 370
340 370
340 500
onable design.
ubtract the supporting
e of the slab.
DESIGN OF TW
Given:
short side A: 7.7 m fc' = 28 mPa
long side B: 7.7 m fy = 420 mPa
f = 0.9
LOADS: f = 0.85
live load: 1.9 kPa conc. unit wt.= 23.5 kN/m3
floorduct
finish: 0.77 kPa CA = 0.061 using 12
mech.
ceiling
allowance finish: 0.578 kPa CADL = 0.023 cover = 20
0.2 kPa CALL = 0.03
electrical load 0.023 kPa CB = 0.033 Ad =
partition load: 0.53 kPa CBDL = 0.02
scellaneous load: 0.5 kPa CBLL = 0.028
SOLUTION:
7.70
ratio m = = 1.000 > 0.500 Two-way Slab!
7.70
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.18 ) ( 23.5 ) = 4.23 kPa
floor finish = 0.77 kPa
ceiling finish = 0.578 kPa
mech. duct allowance = 0.2 kPa
electrical load = 0.023 kPa
partition load = 0.53 kPa
miscellaneous loads = 0.5 kPa
6.83 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2 ( 6.83 ) = 8.197 kPa
WULL = 1.6 (LL) = 1.6 ( 1.9 ) = 3.04 kPa
WU = WUDL + WULL = 11.237 kPa
Solving for Moments:
A. Short Span, Middle Strip
at continuous edge
MA = (Wu) (CA) (A2)
= 40.641 kN-m
at midspan
MADL = (WuDL) (CADL) (A2)
= 11.178 kN-m
MALL = (WuLL) (CALL) (A2)
= 5.407 kN-m
MA = MADL + MALL = 16.586 kN-m
at midspan
MBDL = (WuDL) (CBDL) (B2)
= 9.720 kN-m
MBLL = (WuLL) (CBLL) (B2)
= 5.047 kN-m
MB = MBDL + MBLL = 14.767 kN-m
Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 40.641 x 10e6
Rn = = = 1.904 MPa
fbd 1
2
0.90 x 1000 x (154 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 1.904
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00473 ) ( 1000 ( 154 )
= 728.5770036114 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 155.23410626 mm
As 728.5770036114
say S = 150 mm
at midspan
MA 16.586 x 10e6
Rn = = = 0.777 MPa
fbd 1
2
0.90 x 1000 x (154 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.777
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 154 )
= 513.3333333333 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 220.32467532 mm
As 513.3333333333
say S = 220 mm
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 1.212
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 142 )
= 473.3333333333 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 238.94366197 mm
As 473.3333333333
say S = 230 mm
at midspan
MB 14.767 x 10e6
Rn = = = 0.814 MPa
fbd 2
2
0.90 x 1000 x (142 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.814
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 142 )
= 473.3333333333 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 238.94366197 mm
As 473.3333333333
say S = 230 mm
RESULTING TABLE
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab dimensions
concrete stress and strain
mm type of loading
miscellaneous dead loads
rebars diameter and concrete cover
mm constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
beam dimensions.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
5. Having discontinuous edge will depend upon the case of the slab.
As seen on the table, depends on slab's case.
0.00473
0.00333
0.02064
0.00188
0.00333
0.02064
0.00296
0.00333
0.02064
0.00197
0.00333
0.02064
Column Strip
S (mm)
220 220
320 320
360 530
340 340
340 340
360 530
onable design.
ubtract the supporting
e of the slab.
DESIGN OF TW
Given:
short side A: 1.3 m fc' = 28 mPa
long side B: 1.65 m fy = 420 mPa
f = 0.9
LOADS: f = 0.85
live load: 1.9 kPa conc. unit wt.= 23.5 kN/m3
floorduct
finish: 0.77 kPa CA = 0.066 using 12
mech.
ceiling
allowance finish: 0.578 kPa CADL = 0.026 cover = 20
0.2 kPa CALL = 0.042
electrical load 0.023 kPa CB = 0.029 Ad =
partition load: 0.53 kPa CBDL = 0.011
scellaneous load: 0.5 kPa CBLL = 0.016
SOLUTION:
1.30
ratio m = = 0.788 > 0.500 Two-way Slab!
1.65
d1 = h - (cover) - (rebar f) = 64 mm
d2 = h - (cover) - (rebar f) - (half of rebar f) = 52
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.09 ) ( 23.5 ) = 2.12 kPa
floor finish = 0.77 kPa
ceiling finish = 0.578 kPa
mech. duct allowance = 0.2 kPa
electrical load = 0.023 kPa
partition load = 0.53 kPa
miscellaneous loads = 0.5 kPa
4.72 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2 ( 4.72 ) = 5.659 kPa
WULL = 1.6 (LL) = 1.6 ( 1.9 ) = 3.04 kPa
WU = WUDL + WULL = 8.699 kPa
Solving for Moments:
A. Short Span, Middle Strip
at continuous edge
MA = (Wu) (CA) (A2)
= 0.970 kN-m
at midspan
MADL = (WuDL) (CADL) (A2)
= 0.249 kN-m
MALL = (WuLL) (CALL) (A2)
= 0.216 kN-m
MA = MADL + MALL = 0.464 kN-m
at midspan
MBDL = (WuDL) (CBDL) (B2)
= 0.169 kN-m
MBLL = (WuLL) (CBLL) (B2)
= 0.132 kN-m
MB = MBDL + MBLL = 0.302 kN-m
Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 0.970 x 10e6
Rn = = = 0.263 MPa
fbd 1
2
0.90 x 1000 x (64 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.263
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 64 )
= 213.3333333333 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 530.15625 mm
As 213.3333333333
say S = 530 mm
at midspan
MA 0.464 x 10e6
Rn = = = 0.126 MPa
fbd 1
2
0.90 x 1000 x (64 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.126
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 64 )
= 213.3333333333 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 530.15625 mm
As 213.3333333333
say S = 530 mm
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.282
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 52 )
= 173.3333333333 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 652.5 mm
As 173.3333333333
say S = 650 mm
at midspan
MB 0.302 x 10e6
Rn = = = 0.124 MPa
fbd 2
2
0.90 x 1000 x (52 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.124
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 52 )
= 173.3333333333 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 652.5 mm
As 173.3333333333
say S = 650 mm
RESULTING TABLE
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab dimensions
concrete stress and strain
mm type of loading
miscellaneous dead loads
rebars diameter and concrete cover
mm constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
beam dimensions.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
5. Having discontinuous edge will depend upon the case of the slab.
As seen on the table, depends on slab's case.
0.00063
0.00333
0.02064
0.00030
0.00333
0.02064
0.00068
0.00333
0.02064
0.00030
0.00333
0.02064
Column Strip
S (mm)
180 260
180 260
180 260
180 260
180 260
180 260
onable design.
ubtract the supporting
e of the slab.
DESIGN OF TW
Given:
short side A: 0.8 m fc' = 28 mPa
long side B: 1.3 m fy = 420 mPa
f = 0.9
LOADS: f = 0.85
live load: 1.9 kPa conc. unit wt.= 23.5 kN/m3
floorduct
finish: 0.77 kPa CA = 0.084 using 12
mech.
ceiling
allowance finish: 0.578 kPa CADL = 0.035 cover = 20
0.2 kPa CALL = 0.057
electrical load 0.023 kPa CB = 0.006 Ad =
partition load: 0.53 kPa CBDL = 0.004
scellaneous load: 0.5 kPa CBLL = 0.008
SOLUTION:
0.80
ratio m = = 0.615 > 0.500 Two-way Slab!
1.30
d1 = h - (cover) - (rebar f) = 64 mm
d2 = h - (cover) - (rebar f) - (half of rebar f) = 52
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.09 ) ( 23.5 ) = 2.12 kPa
floor finish = 0.77 kPa
ceiling finish = 0.578 kPa
mech. duct allowance = 0.2 kPa
electrical load = 0.023 kPa
partition load = 0.53 kPa
miscellaneous loads = 0.5 kPa
4.72 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2 ( 4.72 ) = 5.659 kPa
WULL = 1.6 (LL) = 1.6 ( 1.9 ) = 3.04 kPa
WU = WUDL + WULL = 8.699 kPa
Solving for Moments:
A. Short Span, Middle Strip
at continuous edge
MA = (Wu) (CA) (A2)
= 0.468 kN-m
at midspan
MADL = (WuDL) (CADL) (A2)
= 0.127 kN-m
MALL = (WuLL) (CALL) (A2)
= 0.111 kN-m
MA = MADL + MALL = 0.238 kN-m
at midspan
MBDL = (WuDL) (CBDL) (B2)
= 0.038 kN-m
MBLL = (WuLL) (CBLL) (B2)
= 0.041 kN-m
MB = MBDL + MBLL = 0.079 kN-m
Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 0.468 x 10e6
Rn = = = 0.127 MPa
fbd 1
2
0.90 x 1000 x (64 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.127
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 64 )
= 213.3333333333 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 530.15625 mm
As 213.3333333333
say S = 530 mm
at midspan
MA 0.238 x 10e6
Rn = = = 0.064 MPa
fbd 1
2
0.90 x 1000 x (64 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.064
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 64 )
= 213.3333333333 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 530.15625 mm
As 213.3333333333
say S = 530 mm
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.036
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 52 )
= 173.3333333333 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 652.5 mm
As 173.3333333333
say S = 650 mm
at midspan
MB 0.079 x 10e6
Rn = = = 0.033 MPa
fbd 2
2
0.90 x 1000 x (52 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.033
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 52 )
= 173.3333333333 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 652.5 mm
As 173.3333333333
say S = 650 mm
RESULTING TABLE
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab dimensions
concrete stress and strain
mm type of loading
miscellaneous dead loads
rebars diameter and concrete cover
mm constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
beam dimensions.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
5. Having discontinuous edge will depend upon the case of the slab.
As seen on the table, depends on slab's case.
0.00030
0.00333
0.02064
0.00015
0.00333
0.02064
0.00009
0.00333
0.02064
0.00008
0.00333
0.02064
Column Strip
S (mm)
180 260
180 260
180 260
180 260
180 260
180 260
onable design.
ubtract the supporting
e of the slab.
DESIGN OF TW
Given:
short side A: 1.65 m fc' = 28 mPa
long side B: 2.5 m fy = 420 mPa
f = 0.9
LOADS: f = 0.85
live load: 1.9 kPa conc. unit wt.= 23.5 kN/m3
floorduct
finish: 0.77 kPa CA = 0.073 using 12
mech.
ceiling
allowance finish: 0.578 kPa CADL = 0.043 cover = 20
0.2 kPa CALL = 0.058
electrical load 0.023 kPa CB = 0.025 Ad =
partition load: 0.53 kPa CBDL = 0.009
scellaneous load: 0.5 kPa CBLL = 0.012
SOLUTION:
1.65
ratio m = = 0.660 > 0.500 Two-way Slab!
2.50
d1 = h - (cover) - (rebar f) = 64 mm
d2 = h - (cover) - (rebar f) - (half of rebar f) = 52
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.09 ) ( 23.5 ) = 2.12 kPa
floor finish = 0.77 kPa
ceiling finish = 0.578 kPa
mech. duct allowance = 0.2 kPa
electrical load = 0.023 kPa
partition load = 0.53 kPa
miscellaneous loads = 0.5 kPa
4.72 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2 ( 4.72 ) = 5.659 kPa
WULL = 1.6 (LL) = 1.6 ( 1.9 ) = 3.04 kPa
WU = WUDL + WULL = 8.699 kPa
Solving for Moments:
A. Short Span, Middle Strip
at continuous edge
MA = (Wu) (CA) (A2)
= 1.729 kN-m
at midspan
MADL = (WuDL) (CADL) (A2)
= 0.663 kN-m
MALL = (WuLL) (CALL) (A2)
= 0.480 kN-m
MA = MADL + MALL = 1.143 kN-m
at midspan
MBDL = (WuDL) (CBDL) (B2)
= 0.318 kN-m
MBLL = (WuLL) (CBLL) (B2)
= 0.228 kN-m
MB = MBDL + MBLL = 0.546 kN-m
Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 1.729 x 10e6
Rn = = = 0.469 MPa
fbd 1
2
0.90 x 1000 x (64 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.469
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 64 )
= 213.3333333333 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 530.15625 mm
As 213.3333333333
say S = 530 mm
at midspan
MA 1.143 x 10e6
Rn = = = 0.310 MPa
fbd 1
2
0.90 x 1000 x (64 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.310
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 64 )
= 213.3333333333 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 530.15625 mm
As 213.3333333333
say S = 530 mm
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.559
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 52 )
= 173.3333333333 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 652.5 mm
As 173.3333333333
say S = 650 mm
at midspan
MB 0.546 x 10e6
Rn = = = 0.224 MPa
fbd 2
2
0.90 x 1000 x (52 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.224
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 52 )
= 173.3333333333 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 652.5 mm
As 173.3333333333
say S = 650 mm
RESULTING TABLE
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab dimensions
concrete stress and strain
mm type of loading
miscellaneous dead loads
rebars diameter and concrete cover
mm constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
beam dimensions.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
5. Having discontinuous edge will depend upon the case of the slab.
As seen on the table, depends on slab's case.
0.00113
0.00333
0.02064
0.00074
0.00333
0.02064
0.00135
0.00333
0.02064
0.00054
0.00333
0.02064
Column Strip
S (mm)
180 260
180 260
180 260
180 260
180 260
180 260
onable design.
ubtract the supporting
e of the slab.
DESIGN OF TW
Given:
short side A: 5.875 m fc' = 28 mPa
long side B: 6m fy = 420 mPa
f = 0.9
LOADS: f = 0.85
live load: 2.4 kPa conc. unit wt.= 23.5 kN/m3
floorduct
finish: 0.77 kPa CA = 0.047 using 12
mech.
ceiling
allowance finish: 0 kPa CADL = 0.019 cover = 20
0 kPa CALL = 0.028
electrical load 0.023 kPa CB = 0.043 Ad =
partition load: 0 kPa CBDL = 0.017
scellaneous load: 0.5 kPa CBLL = 0.026
SOLUTION:
5.88
ratio m = = 0.980 > 0.500 Two-way Slab!
6.00
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.17 ) ( 23.5 ) = 4.00 kPa
floor finish = 0.77 kPa
ceiling finish = 0 kPa
mech. duct allowance = 0 kPa
electrical load = 0.023 kPa
partition load = 0 kPa
miscellaneous loads = 0.5 kPa
5.29 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2 ( 5.29 ) = 6.346 kPa
WULL = 1.6 (LL) = 1.6 ( 2.4 ) = 3.84 kPa
WU = WUDL + WULL = 10.186 kPa
Solving for Moments:
A. Short Span, Middle Strip
at continuous edge
MA = (Wu) (CA) (A2)
= 16.523 kN-m
at midspan
MADL = (WuDL) (CADL) (A2)
= 4.161 kN-m
MALL = (WuLL) (CALL) (A2)
= 3.711 kN-m
MA = MADL + MALL = 7.873 kN-m
at midspan
MBDL = (WuDL) (CBDL) (B2)
= 3.884 kN-m
MBLL = (WuLL) (CBLL) (B2)
= 3.594 kN-m
MB = MBDL + MBLL = 7.478 kN-m
Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 16.523 x 10e6
Rn = = = 0.885 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.885
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
at midspan
MA 7.873 x 10e6
Rn = = = 0.422 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.422
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 1.005
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
at midspan
MB 7.478 x 10e6
Rn = = = 0.477 MPa
fbd 2
2
0.90 x 1000 x (132 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.477
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
RESULTING TABLE
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab dimensions
concrete stress and strain
mm type of loading
miscellaneous dead loads
rebars diameter and concrete cover
mm constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
beam dimensions.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
5. Having discontinuous edge will depend upon the case of the slab.
As seen on the table, depends on slab's case.
0.00215
0.00333
0.02064
0.00101
0.00333
0.02064
0.00245
0.00333
0.02064
0.00115
0.00333
0.02064
Column Strip
S (mm)
340 340
340 340
340 500
340 370
340 370
340 500
onable design.
ubtract the supporting
e of the slab.
DESIGN OF TW
Given:
short side A: 5m fc' = 28 mPa
long side B: 5.875 m fy = 420 mPa
f = 0.9
LOADS: f = 0.85
live load: 2.4 kPa conc. unit wt.= 23.5 kN/m3
floorduct
finish: 0.77 kPa CA = 0.06 using 12
mech.
ceiling
allowance finish: 0 kPa CADL = 0.024 cover = 20
0 kPa CALL = 0.037
electrical load 0.023 kPa CB = 0.031 Ad =
partition load: 0 kPa CBDL = 0.012
scellaneous load: 0.5 kPa CBLL = 0.019
SOLUTION:
5.00
ratio m = = 0.850 > 0.500 Two-way Slab!
5.88
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.17 ) ( 23.5 ) = 4.00 kPa
floor finish = 0.77 kPa
ceiling finish = 0 kPa
mech. duct allowance = 0 kPa
electrical load = 0.023 kPa
partition load = 0 kPa
miscellaneous loads = 0.5 kPa
5.29 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2 ( 5.29 ) = 6.346 kPa
WULL = 1.6 (LL) = 1.6 ( 2.4 ) = 3.84 kPa
WU = WUDL + WULL = 10.186 kPa
Solving for Moments:
A. Short Span, Middle Strip
at continuous edge
MA = (Wu) (CA) (A2)
= 15.278 kN-m
at midspan
MADL = (WuDL) (CADL) (A2)
= 3.807 kN-m
MALL = (WuLL) (CALL) (A2)
= 3.552 kN-m
MA = MADL + MALL = 7.359 kN-m
at midspan
MBDL = (WuDL) (CBDL) (B2)
= 2.628 kN-m
MBLL = (WuLL) (CBLL) (B2)
= 2.518 kN-m
MB = MBDL + MBLL = 5.147 kN-m
Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 15.278 x 10e6
Rn = = = 0.819 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.819
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
at midspan
MA 7.359 x 10e6
Rn = = = 0.394 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.394
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.695
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
at midspan
MB 5.147 x 10e6
Rn = = = 0.328 MPa
fbd 2
2
0.90 x 1000 x (132 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.328
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
RESULTING TABLE
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab dimensions
concrete stress and strain
mm type of loading
miscellaneous dead loads
rebars diameter and concrete cover
mm constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
beam dimensions.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
5. Having discontinuous edge will depend upon the case of the slab.
As seen on the table, depends on slab's case.
0.00198
0.00333
0.02064
0.00095
0.00333
0.02064
0.00168
0.00333
0.02064
0.00079
0.00333
0.02064
Column Strip
S (mm)
340 340
340 340
340 500
340 370
340 370
340 500
onable design.
ubtract the supporting
e of the slab.
DESIGN OF TW
Given:
short side A: 5.875 m fc' = 28 mPa
long side B: 8m fy = 420 mPa
f = 0.9
LOADS: f = 0.85
live load: 2.4 kPa conc. unit wt.= 23.5 kN/m3
floorduct
finish: 0.77 kPa CA = 0.078 using 12
mech.
ceiling
allowance finish: 0 kPa CADL = 0.044 cover = 20
0 kPa CALL = 0.54
electrical load 0.023 kPa CB = 0.023 Ad =
partition load: 0 kPa CBDL = 0.012
scellaneous load: 0.5 kPa CBLL = 0.015
SOLUTION:
5.88
ratio m = = 0.735 > 0.500 Two-way Slab!
8.00
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.17 ) ( 23.5 ) = 4.00 kPa
floor finish = 0.77 kPa
ceiling finish = 0 kPa
mech. duct allowance = 0 kPa
electrical load = 0.023 kPa
partition load = 0 kPa
miscellaneous loads = 0.5 kPa
5.29 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2 ( 5.29 ) = 6.346 kPa
WULL = 1.6 (LL) = 1.6 ( 2.4 ) = 3.84 kPa
WU = WUDL + WULL = 10.186 kPa
Solving for Moments:
A. Short Span, Middle Strip
at continuous edge
MA = (Wu) (CA) (A2)
= 27.422 kN-m
at midspan
MADL = (WuDL) (CADL) (A2)
= 9.637 kN-m
MALL = (WuLL) (CALL) (A2)
= 71.572 kN-m
MA = MADL + MALL = 81.209 kN-m
at midspan
MBDL = (WuDL) (CBDL) (B2)
= 4.873 kN-m
MBLL = (WuLL) (CBLL) (B2)
= 3.686 kN-m
MB = MBDL + MBLL = 8.560 kN-m
Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 27.422 x 10e6
Rn = = = 1.469 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 1.469
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00361 ) ( 1000 ( 144 )
= 520.3745302888 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 217.34345825 mm
As 520.3745302888
say S = 210 mm
at midspan
MA 81.209 x 10e6
Rn = = = 4.351 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 4.351
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.01153 ) ( 1000 ( 144 )
= 1660.973343532 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 68.092603918 mm
As 1660.973343532
say S = 60 mm
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.956
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
at midspan
MB 8.560 x 10e6
Rn = = = 0.546 MPa
fbd 2
2
0.90 x 1000 x (132 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.546
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
RESULTING TABLE
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab dimensions
concrete stress and strain
mm type of loading
miscellaneous dead loads
rebars diameter and concrete cover
mm constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
beam dimensions.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
5. Having discontinuous edge will depend upon the case of the slab.
As seen on the table, depends on slab's case.
0.00361
0.00333
0.02064
0.01153
0.00333
0.02064
0.00232
0.00333
0.02064
0.00131
0.00333
0.02064
Column Strip
S (mm)
310 310
80 80
260 260
340 370
340 370
340 500
onable design.
ubtract the supporting
e of the slab.
DESIGN OF TW
Given:
short side A: 5.875 m fc' = 28 mPa
long side B: 6m fy = 420 mPa
f = 0.9
LOADS: f = 0.85
live load: 2.4 kPa conc. unit wt.= 23.5 kN/m3
floorduct
finish: 0.77 kPa CA = 0.078 using 12
mech.
ceiling
allowance finish: 0 kPa CADL = 0.044 cover = 20
0 kPa CALL = 0.54
electrical load 0.023 kPa CB = 0.023 Ad =
partition load: 0 kPa CBDL = 0.012
scellaneous load: 0.5 kPa CBLL = 0.015
SOLUTION:
5.88
ratio m = = 0.980 > 0.500 Two-way Slab!
6.00
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.17 ) ( 23.5 ) = 4.00 kPa
floor finish = 0.77 kPa
ceiling finish = 0 kPa
mech. duct allowance = 0 kPa
electrical load = 0.023 kPa
partition load = 0 kPa
miscellaneous loads = 0.5 kPa
5.29 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2 ( 5.29 ) = 6.346 kPa
WULL = 1.6 (LL) = 1.6 ( 2.4 ) = 3.84 kPa
WU = WUDL + WULL = 10.186 kPa
Solving for Moments:
A. Short Span, Middle Strip
at continuous edge
MA = (Wu) (CA) (A2)
= 27.422 kN-m
at midspan
MADL = (WuDL) (CADL) (A2)
= 9.637 kN-m
MALL = (WuLL) (CALL) (A2)
= 71.572 kN-m
MA = MADL + MALL = 81.209 kN-m
at midspan
MBDL = (WuDL) (CBDL) (B2)
= 2.741 kN-m
MBLL = (WuLL) (CBLL) (B2)
= 2.074 kN-m
MB = MBDL + MBLL = 4.815 kN-m
Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 27.422 x 10e6
Rn = = = 1.469 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 1.469
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00361 ) ( 1000 ( 144 )
= 520.3745302888 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 217.34345825 mm
As 520.3745302888
say S = 210 mm
at midspan
MA 81.209 x 10e6
Rn = = = 4.351 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 4.351
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.01153 ) ( 1000 ( 144 )
= 1660.973343532 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 68.092603918 mm
As 1660.973343532
say S = 60 mm
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.538
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
at midspan
MB 4.815 x 10e6
Rn = = = 0.307 MPa
fbd 2
2
0.90 x 1000 x (132 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.307
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
RESULTING TABLE
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab dimensions
concrete stress and strain
mm type of loading
miscellaneous dead loads
rebars diameter and concrete cover
mm constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
beam dimensions.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
5. Having discontinuous edge will depend upon the case of the slab.
As seen on the table, depends on slab's case.
0.00361
0.00333
0.02064
0.01153
0.00333
0.02064
0.00130
0.00333
0.02064
0.00074
0.00333
0.02064
Column Strip
S (mm)
310 310
80 80
260 260
340 370
340 370
340 500
onable design.
ubtract the supporting
e of the slab.
DESIGN OF TW
Given:
short side A: 5m fc' = 28 mPa
long side B: 5.875 m fy = 420 mPa
f = 0.9
LOADS: f = 0.85
live load: 2.4 kPa conc. unit wt.= 23.5 kN/m3
floorduct
finish: 0.77 kPa CA = 0.049 using 12
mech.
ceiling
allowance finish: 0 kPa CADL = 0.029 cover = 20
0 kPa CALL = 0.04
electrical load 0.023 kPa CB = 0.046 Ad =
partition load: 0 kPa CBDL = 0.017
scellaneous load: 0.5 kPa CBLL = 0.022
SOLUTION:
5.00
ratio m = = 0.850 > 0.500 Two-way Slab!
5.88
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.17 ) ( 23.5 ) = 4.00 kPa
floor finish = 0.77 kPa
ceiling finish = 0 kPa
mech. duct allowance = 0 kPa
electrical load = 0.023 kPa
partition load = 0 kPa
miscellaneous loads = 0.5 kPa
5.29 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2 ( 5.29 ) = 6.346 kPa
WULL = 1.6 (LL) = 1.6 ( 2.4 ) = 3.84 kPa
WU = WUDL + WULL = 10.186 kPa
Solving for Moments:
A. Short Span, Middle Strip
at continuous edge
MA = (Wu) (CA) (A2)
= 12.477 kN-m
at midspan
MADL = (WuDL) (CADL) (A2)
= 4.601 kN-m
MALL = (WuLL) (CALL) (A2)
= 3.840 kN-m
MA = MADL + MALL = 8.441 kN-m
at midspan
MBDL = (WuDL) (CBDL) (B2)
= 3.723 kN-m
MBLL = (WuLL) (CBLL) (B2)
= 2.916 kN-m
MB = MBDL + MBLL = 6.639 kN-m
Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 12.477 x 10e6
Rn = = = 0.669 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.669
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
at midspan
MA 8.441 x 10e6
Rn = = = 0.452 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.452
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00333 ) ( 1000 ( 144 )
= 480 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 235.625 mm
As 480
say S = 230 mm
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 1.031
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
at midspan
MB 6.639 x 10e6
Rn = = = 0.423 MPa
fbd 2
2
0.90 x 1000 x (132 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.423
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
RESULTING TABLE
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab dimensions
concrete stress and strain
mm type of loading
miscellaneous dead loads
rebars diameter and concrete cover
mm constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
beam dimensions.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
5. Having discontinuous edge will depend upon the case of the slab.
As seen on the table, depends on slab's case.
0.00161
0.00333
0.02064
0.00109
0.00333
0.02064
0.00251
0.00333
0.02064
0.00102
0.00333
0.02064
Column Strip
S (mm)
340 340
340 340
340 500
340 370
340 370
340 500
onable design.
ubtract the supporting
e of the slab.
DESIGN OF TW
Given:
short side A: 5.875 m fc' = 28 mPa
long side B: 8m fy = 420 mPa
f = 0.9
LOADS: f = 0.85
live load: 2.4 kPa conc. unit wt.= 23.5 kN/m3
floorduct
finish: 0.77 kPa CA = 0.078 using 12
mech.
ceiling
allowance finish: 0 kPa CADL = 0.044 cover = 20
0 kPa CALL = 0.54
electrical load 0.023 kPa CB = 0.023 Ad =
partition load: 0 kPa CBDL = 0.012
scellaneous load: 0.5 kPa CBLL = 0.015
SOLUTION:
5.88
ratio m = = 0.735 > 0.500 Two-way Slab!
8.00
Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.17 ) ( 23.5 ) = 4.00 kPa
floor finish = 0.77 kPa
ceiling finish = 0 kPa
mech. duct allowance = 0 kPa
electrical load = 0.023 kPa
partition load = 0 kPa
miscellaneous loads = 0.5 kPa
5.29 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2 ( 5.29 ) = 6.346 kPa
WULL = 1.6 (LL) = 1.6 ( 2.4 ) = 3.84 kPa
WU = WUDL + WULL = 10.186 kPa
Solving for Moments:
A. Short Span, Middle Strip
at continuous edge
MA = (Wu) (CA) (A2)
= 27.422 kN-m
at midspan
MADL = (WuDL) (CADL) (A2)
= 9.637 kN-m
MALL = (WuLL) (CALL) (A2)
= 71.572 kN-m
MA = MADL + MALL = 81.209 kN-m
at midspan
MBDL = (WuDL) (CBDL) (B2)
= 4.873 kN-m
MBLL = (WuLL) (CBLL) (B2)
= 3.686 kN-m
MB = MBDL + MBLL = 8.560 kN-m
Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 27.422 x 10e6
Rn = = = 1.469 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 1.469
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.00361 ) ( 1000 ( 144 )
= 520.3745302888 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 217.34345825 mm
As 520.3745302888
say S = 210 mm
at midspan
MA 81.209 x 10e6
Rn = = = 4.351 MPa
fbd 1
2
0.90 x 1000 x (144 )2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 4.351
= x 1- 1- =
420 0.85 x 28.0
As = f b d1
= ( 0.01153 ) ( 1000 ( 144 )
= 1660.973343532 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 68.092603918 mm
As 1660.973343532
say S = 60 mm
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.956
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
at midspan
MB 8.560 x 10e6
Rn = = = 0.546 MPa
fbd 2
2
0.90 x 1000 x (132 )
2
0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'
(0.85)( 28 ) 2 x 0.546
= x 1- 1- =
420 0.85 x 28.0
(0.85) f1 fc' 3
rmax = x
fy 7
20.23 3
= x =
420 7
As = f b d2
= ( 0.00333 ) ( 1000 ( 132 )
= 440 mm2
using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 257.04545455 mm
As 440
say S = 250 mm
RESULTING TABLE
GUIDELINES:
1. Fill-up only colored cells with their corresponding values.
slab dimensions
concrete stress and strain
mm type of loading
miscellaneous dead loads
rebars diameter and concrete cover
mm constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
beam dimensions.
4. Checking computations using calculator may will not match with the computer's
computations due to rounding-off numbers. Computer uses complete decimal
numbers and exact values.
5. Having discontinuous edge will depend upon the case of the slab.
As seen on the table, depends on slab's case.
0.00361
0.00333
0.02064
0.01153
0.00333
0.02064
0.00232
0.00333
0.02064
0.00131
0.00333
0.02064
Column Strip
S (mm)
310 310
80 80
260 260
340 370
340 370
340 500
onable design.
ubtract the supporting
e of the slab.