Drain

The document provides calculations for runoff volume and drain sizing for an area of 2430 sq.m. It calculates a runoff coefficient of 0.5, rainfall intensity of 100 mm/hr, and runoff volume of 0.034 cu.m/sec for the catchment area. It then sizes a drain with dimensions of 0.5m width and 0.5m depth, and calculates the drain capacity to be 0.121 cu.m/sec, which meets the required flow. Velocity and other parameters are also calculated to check code compliance.

Uploaded by

Hem Chandra Pant
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
155 views5 pages

Drain

The document provides calculations for runoff volume and drain sizing for an area of 2430 sq.m. It calculates a runoff coefficient of 0.5, rainfall intensity of 100 mm/hr, and runoff volume of 0.034 cu.m/sec for the catchment area. It then sizes a drain with dimensions of 0.5m width and 0.5m depth, and calculates the drain capacity to be 0.121 cu.m/sec, which meets the required flow. Velocity and other parameters are also calculated to check code compliance.

Uploaded by

Hem Chandra Pant
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 5

Basic Calculation

Runoff Volume calculation:


Catchment area, Ac = 2430 sq.m
Rainfall intensity, I= 100 mm/hr
Runoff coefficient, C= 0.5
Volume of runoff, Q = C. I. Ac = 0.034 cu.m/sec

Drain Sizing:
Width of drain, b = 0.500 m (Assume )
Depth of drain, d = 0.500 m (Assume )
Free board, fb = 0.100 m
Wet area of drain, Aft = 0.200 Sq.m
Wet depth of drain dwt= 0.400 m
Wetted Perimeter of flow, pfr = 1.300 m
Hydraulic mean radious, R= 0.154 m
Manning's constant, N= 0.015 [For RCC drain]
Longitudinal slope, S= 0.001 = 1(v) in 1000.00 (h).
Drain capacity = 0.121 cu.m/sec ok
Velocity of flow:
Velocity, V= 1/N*R2/3*S1/2 Min. V Max V
0.61 m/Sec 0.6 2.5
ok
Runoff
Area C.A. I k Q Drain Length Start at End at Serving c.a. Volume from
mkd. m2 mm/hr - cu.m/s mkd. (m) drain mkd. drain mkd. marked c.a. (m3)
CA1 2430 50 0.5 0.017 Dr-1 20 - Dr-2 CA1 0.017
CA2 497 50 0.5 0.003 Dr-2 20 Dr-1 Dr-3 CA2 0.003
CA3 0.000
CA4 0.000
CA5 0.000
CA6 0.000
CA7 0.000
CA8 0.000
CA9 0.000
CA10 0.000
CA11 0.000
CA12 0.000
CA13 0.000
CA14 0.000
CA15 0.000
CA16 0.000
CA17 0.000
CA18 0.000
CA19 0.000
CA20 0.000
Wetted Wetted Hydraulic
runoff Volume Total volume Provided Provided Free Depth of area on Perimeter mean
from of runoff Width of Depth of board wet drain/ drain of flow radious, R
u/s drain (m3) (m3) drain (m) drain (m) (m) flow (m) A, Sq.m. P, m A/P, m
0 0.017 0.3 0.3 0.1 0.2 0.06 0.70 0.086
0.016875 0.020 0.3 0.3 0.1 0.2 0.06 0.70 0.086
Manning's Long. Slope Velocity of Permissible Drain
constant required flow velocity capacity Start End
N 1(V) in H m/sec. of drain (m/s) cu.m/sec depth (m) depth (m)
0.025 150.00 0.63 0.6 to 2.5 0.038 0.3 0.43
0.025 150.00 0.63 0.6 to 2.5 0.038 1.4 1.53