The IS-A105N is a high output intrinsically safe alarm sounder that produces 105dB of sound. It has approvals for use in hazardous locations and intrinsically safe applications. It has 49 configurable tones, 3 stage volume control, and inputs that are protected from overloads and reverse currents. It is powered via a certified Zener barrier or galvanic isolator and has an IP66 weatherproof housing.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
86 views3 pages

1 12 020 Is A105n - Datasheet

The IS-A105N is a high output intrinsically safe alarm sounder that produces 105dB of sound. It has approvals for use in hazardous locations and intrinsically safe applications. It has 49 configurable tones, 3 stage volume control, and inputs that are protected from overloads and reverse currents. It is powered via a certified Zener barrier or galvanic isolator and has an IP66 weatherproof housing.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

1 -1 2-020 / Intr insic ally safe sig nals

IS-A105N Alarm Sounder


The IS-A105N is a high output, 105dB(A) alarm sounder. Approvals include ATEX,
IECEx and GOST-R for Zone 0 applications and FM approval for Class I Division 1 and
Class I Zone 0 applications.
The IS-A105N is suitable for all intrinsically safe signalling applications including fire, security and
process control.

Features
Input overload and reverse current protection
Auto synchronised sound output
Unit can be mounted using external lugs or internal
BESA compatible fixing positions.
Duplicate cable terminations (in & out for daisy-chain
installations).
Available with custom tone configurations and frequencies.

Approvals

ATEX certificate: SIRA 04ATEX2 301X,


EN 60079-0 : 2 012 ,EN 60079-11 : 2 012 ,
IEC 60079-2 6 : 2 014

IECEx certificate: IECEx SIR 04.0038X,


IEC 60079-0 : 2 011, IEC 60079-11 : 2 011,
IEC 60079-2 6 : 2 014

FM approved:
Class 3600 1998, Class 3610 2 010,
Class 3810 2 005, IEC 6052 9 : 1989

G O ST-R certificate: PO CC G B.JB05.B03365


Specification Part Codes
Nominal output: 105dB(A) @ 1m +/- 3dB - Tone 2 *[96dB(A) @ IS-A105N-[x]
10ft/3m]
ATEX / IECEx / FM
No. of tones: 49 (UKO O A/PFEER compliant)
II 1G Ex ia IIC T4 G a (-40º C <=Ta<= +60°C)
No. of stages: 3
IS Class I, Zone 0, AEx ia IIC T4 Ta = +60°C
Volume control:
IS Class l, Division 1, G roups A, B, C, D T4
Max. 105dB(A); Min. 96dB(A) - Tone 2
G O ST-R
Effective range: 60m/197ft @ 1KHz
0ExiaIICT4 IP66 -40° to +60°C
Voltage: 16-2 8vdc via Zener barrier or galvanic isolator
[x] : Housing R: Red G : G rey W: White
Current: 2 5mA typical when powered from 2 4v supply via 2 8v
colour:
300 O hm
Zener barrier
May be powered from any certified Zener barrier or galvanic isolator
Ingress protection: IP66 whose output parameters do not exceed :
Rating: Continuous Uo : 2 8VDC Io : 93mA Po : 660mW
Housing material: UL94V0 & 5VA FR ABS
Housing colour: RAL3000 Red, RAL7038 G rey and White
Fixings: Stainless Steel
Cable entries: 2 x M2 0 clearance gland knockouts.
Custom configurations also available.
Terminals: 0.5 to 2 .5mm²
O perating temp: -40° to +60°C [-40 to +140°F]
Storage temp: -40° to +70°C [-40 to +158°F]
Relative humidity: 90% at 2 0°C [68°F]
Weight : 0.75kg/1.65Ibs
Tone table
S 1 Desc ri pti on S 2 S 3 S 1 Desc ri pti on S 2 S 3
T 1 340 Hz Continuous T2 T5 T 33 745Hz @ 1Hz Intermittent T2 T5
T2 800/1000Hz @ 0.2 5 sec Alternating T 17 T 5 T 34 1000 & 2 000Hz @ 0.5 sec Alternating - Singapore T 38 T 45
T3 500/12 00Hz @ 0.3Hz 0.5 sec Slow Whoop T2 T5 T 35 42 0Hz @ 0.62 5 sec Australian Alert T 36 T 5
T4 800/1000Hz @ 1Hz Sweeping T6 T5 T 36 500-12 00Hz 3.75sec /0.2 5sec. Australian Evac. T 35 T 5
T5 2 400Hz Continuous T3 T 20 T 37 1000Hz Continuous - PFEER Toxic G as T9 T 45
T6 2 400/2 900Hz @ 7Hz Sweeping T7 T5 T 38 2 000Hz Continuous T 34 T 45
T7 2 400/2 900Hz @ 1Hz Sweeping T 10 T 5 T 39 800Hz 0.2 5sec on, 1 sec off Intermittent T 2 3 T 17
T8 500/12 00/500Hz @ 0.3Hz Sweeping T2 T5 T 40 544Hz (100mS)/440Hz (400mS) - NF S 32 -001 T 31 T 2 7
T9 12 00/500Hz @ 1Hz - DIN / PFEER P.T.A.P. T 15 T 2 T 41 Motor Siren - slow rise to 12 00 Hz T2 T5
T 10 2 400/2 900Hz @ 2 Hz Alternating T7 T5 T 42 Motor Siren - slow rise to 800 Hz T2 T5
T 11 1000Hz @ 1Hz Intermittent T2 T5 T 43 12 00 Hz Continuous T2 T5
T 12 800/1000Hz @ 0.875Hz Alternating T4 T5 T 44 Motor Siren - slow rise to 2 400 Hz T2 T5
T 13 2 400Hz @ 1Hz Intermittent T 15 T 5 T 45 1KHz 1s on, 1s off Intermittent - PFEER G en. ... T 38 T 34
T 14 800Hz 0.2 5sec on, 1 sec off Intermittent T4 T5 T 46 12 00/500Hz @ 1Hz - DIN / PFEER P.T.A.P. T 47 T 37
T 15 800Hz Continuous T2 T5 T 47 1KHz 1s on, 1s off Intermittent - PFEER G en. ... T 46 T 37
T 16 660Hz 150mS on, 150mS off Intermittent T 18 T 5 T 48 42 0Hz @ 0.62 5 sec Australian Alert T 49 T 5
T 17 544Hz (100mS)/440Hz (400mS) - NF S 32 -001 T2 T 27 T 49 500-12 00Hz 3.75sec /0.2 5sec. Australian Evac. T 2 6 T 37
T 18 660Hz 1.8sec on, 1.8sec off Intermittent T2 T5
T 19 1.4KHz-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s -NFC48-2 65 T2 T5
T 2 0 660Hz Continuous T2 T5
T 2 1 554Hz/440Hz @ 1Hz Alternating T2 T5
T 2 2 544Hz @ 0.875 sec. Intermittent T2 T5
T 2 3 800Hz @ 2 Hz Intermittent T6 T5
T 2 4 800/1000Hz @ 50Hz Sweeping T 29 T 5
T 2 5 2 400/2 900Hz @ 50Hz Sweeping T 29 T 5
T 2 6 Bell T2 T 15
T 2 7 554Hz Continuous T 26 T 5
T 2 8 440Hz Continuous T2 T5
T 2 9 800/1000Hz @ 7Hz Sweeping T7 T5
T 30 300Hz Continuous T2 T5
T 31 660/12 00Hz @ 1Hz Sweeping T 26 T 5
T 32 Two T chime. T 2 6 T 15

E2S Warning Signals [email protected] www.e2s.com 26 Sep 2017