0% found this document useful (0 votes)
174 views

Automatic Irrigation Calculation Sheet

This document summarizes the sprinkler zones, nozzles, flows, and sizing valves for 3 zones. Zone 1 uses a 2 inch SRV valve and covers areas with radii from 4 to 17 feet. Zone 2 uses a 3 inch PGV Jar-Top valve and covers the same range of radii. Zone 3 again uses a 2 inch SRV valve and covers radii from 4 to 17 feet. Each zone lists the nozzles, flows, and pressures needed to irrigate the different areas.

Uploaded by

senghou
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
174 views

Automatic Irrigation Calculation Sheet

This document summarizes the sprinkler zones, nozzles, flows, and sizing valves for 3 zones. Zone 1 uses a 2 inch SRV valve and covers areas with radii from 4 to 17 feet. Zone 2 uses a 3 inch PGV Jar-Top valve and covers the same range of radii. Zone 3 again uses a 2 inch SRV valve and covers radii from 4 to 17 feet. Each zone lists the nozzles, flows, and pressures needed to irrigate the different areas.

Uploaded by

senghou
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 30

SPRINKLER ZON

Type of irrigation in each zone


using adjustable nozzeles
45 degree 90 degree 120 degree
no. GPM T.GPM no. GPM T.GPM no. GPM
4A (" 4 foot radius") 1 0 0.13 0 1 0.28 0.28 1 0.34
6A (" 6 foot radius") = 0 0.18 0 1 0.37 0.37 1 0.44
8A (" 8 foot radius") = 0 0.15 0 1 0.29 0.29 1 0.39
10A (" 10 foot radius") = 0 0.25 0 1 0.49 0.49 1 0.65
12A (" 12 foot radius") = 0 0.32 0 0 0.63 0 0 0.84
15A (" 15 foot radius") = 0 0.47 0 0 0.93 0 0 1.24
17A (" 17 foot radius") = 0 0.6 0 0 1.2 0 0 1.6
Total Angle Flow 0 1.43 1.82
Total Nozzel Flow 37

Sizing Valve

Type of vlave will be used

Minimum pipe size for flow with maximum 4 ft/sec velocity in pipes 2
Valve Model SRV Valve
Valve Type ###
Pressure Losses in Vlave ###

Note :
You can Use Valve different betweeen pipe size by 1 diameter

pipe size for flow with maximum 4 ft/sec velocity in pipes 1.5
Valve Model SRV Valve
Valve Type ###
Pressure Losses in Vlave ###
KLER ZONE 1
120 degree 180 degree 240 degree 270 degree 360 degree
T.GPM no. GPM T.GPM no. GPM T.GPM no. GPM T.GPM no. GPM T.GPM
0.34 1 0.45 0.45 0 0.68 0 1 0.73 0.73 0 0.8 0
0.44 1 0.6 0.6 0 0.88 0 1 1.1 1.1 0 1.26 0
0.39 1 0.58 0.58 0 0.78 0 1 0.87 0.87 0 1.16 0
0.65 0 0.98 0 0 1.31 0 1 1.47 1.47 0 1.96 0
0 0 1.26 0 0 1.68 0 0 1.89 0 0 2.52 0
0 0 1.86 0 0 2.48 0 0 2.79 0 0 3.72 0
0 0 2.4 0 0 3.2 0 0 3.6 0 6 4.8 28.8
1.82 1.63 0 4.17 28.8
37.85

inch
SRV Valve

inch
SRV Valve
SPRINKLER ZON
Type of irrigation in each zone
using adjustable nozzeles
45 degree 90 degree 120 degree
no. GPM T.GPM no. GPM T.GPM no. GPM
4A (" 4 foot radius") = 0 0.13 0 1 0.28 0.28 1 0.34
6A (" 6 foot radius") = 0 0.18 0 1 0.37 0.37 1 0.44
8A (" 8 foot radius") = 0 0.15 0 1 0.29 0.29 1 0.39
10A (" 10 foot radius") = 0 0.25 0 1 0.49 0.49 1 0.65
12A (" 12 foot radius") = 0 0.32 0 0 0.63 0 0 0.84
15A (" 15 foot radius") = 0 0.47 0 0 0.93 0 0 1.24
17A (" 17 foot radius") = 0 0.6 0 0 1.2 0 0 1.6
Total Angle Flow 0 1.43 1.82
Total Nozzel Flow 249.

Sizing Valve

Type of vlave will be used PGV Jar-Top

Minimum pipe size for flow with maximum 4 ft/sec velocity in pipes 3
Valve Model PGV Jar-Top Valve
Valve Type ###
Pressure Losses in Vlave ###

Note :
You can Use Valve different betweeen pipe size by 1 diameter

pipe size for flow with maximum 4 ft/sec velocity in pipes 1.5
Valve Model PGV Jar-Top Valve
Valve Type ###
Pressure Losses in Vlave ###
KLER ZONE 2
120 degree 180 degree 240 degree 270 degree 360 degree
T.GPM no. GPM T.GPM no. GPM T.GPM no. GPM T.GPM no. GPM T.GPM
0.34 1 0.45 0.45 0 0.68 0 1 0.73 0.73 0 0.8 0
0.44 1 0.6 0.6 0 0.88 0 1 1.1 1.1 0 1.26 0
0.39 1 0.58 0.58 0 0.78 0 1 0.87 0.87 0 1.16 0
0.65 0 0.98 0 0 1.31 0 1 1.47 1.47 0 1.96 0
0 0 1.26 0 0 1.68 0 0 1.89 0 0 2.52 0
0 0 1.86 0 0 2.48 0 0 2.79 0 0 3.72 0
0 0 2.4 0 0 3.2 0 0 3.6 0 50 4.8 240
1.82 1.63 0 4.17 240
249.05

inch
PGV Jar-Top Valve

inch
PGV Jar-Top Valve
SPRINKLER ZON
Type of irrigation in each zone
using adjustable nozzeles
45 degree 90 degree 120 degree
no. GPM T.GPM no. GPM T.GPM no. GPM
4A (" 4 foot radius") = 0 0.13 0 1 0.28 0.28 1 0.34
6A (" 6 foot radius") = 0 0.18 0 1 0.37 0.37 1 0.44
8A (" 8 foot radius") = 0 0.15 0 1 0.29 0.29 1 0.39
10A (" 10 foot radius") = 0 0.25 0 1 0.49 0.49 1 0.65
12A (" 12 foot radius") = 0 0.32 0 0 0.63 0 0 0.84
15A (" 15 foot radius") = 0 0.47 0 0 0.93 0 0 1.24
17A (" 17 foot radius") = 0 0.6 0 0 1.2 0 0 1.6
Total Angle Flow 0 1.43 1.82
Total Nozzel Flow 33

Sizing Valve

Type of vlave will be used

Minimum pipe size for flow with maximum 4 ft/sec velocity in pipes 2
Valve Model SRV Valve
Valve Type ###
Pressure Losses in Vlave ###

Note :
You can Use Valve different betweeen pipe size by 1 diameter

pipe size for flow with maximum 4 ft/sec velocity in pipes 1.5
Valve Model SRV Valve
Valve Type ###
Pressure Losses in Vlave ###
KLER ZONE 3
120 degree 180 degree 240 degree 270 degree 360 degree
T.GPM no. GPM T.GPM no. GPM T.GPM no. GPM T.GPM no. GPM T.GPM
0.34 1 0.45 0.45 0 0.68 0 1 0.73 0.73 0 0.8 0
0.44 1 0.6 0.6 0 0.88 0 1 1.1 1.1 0 1.26 0
0.39 1 0.58 0.58 0 0.78 0 1 0.87 0.87 0 1.16 0
0.65 0 0.98 0 0 1.31 0 1 1.47 1.47 0 1.96 0
0 0 1.26 0 0 1.68 0 0 1.89 0 0 2.52 0
0 0 1.86 0 0 2.48 0 0 2.79 0 0 3.72 0
0 0 2.4 0 0 3.2 0 0 3.6 0 5 4.8 24
1.82 1.63 0 4.17 24
33.05

inch
SRV Valve

inch
SRV Valve
SPRINKLER ZON
Type of irrigation in each zone
using adjustable nozzeles
45 degree 90 degree 120 degree
no. GPM T.GPM no. GPM T.GPM no. GPM
4A (" 4 foot radius") = 0 0.13 0 1 0.28 0.28 1 0.34
6A (" 6 foot radius") = 0 0.18 0 1 0.37 0.37 1 0.44
8A (" 8 foot radius") = 0 0.15 0 1 0.29 0.29 1 0.39
10A (" 10 foot radius") = 0 0.25 0 1 0.49 0.49 1 0.65
12A (" 12 foot radius") = 0 0.32 0 0 0.63 0 0 0.84
15A (" 15 foot radius") = 0 0.47 0 0 0.93 0 0 1.24
17A (" 17 foot radius") = 0 0.6 0 0 1.2 0 0 1.6
Total Angle Flow 0 1.43 1.82
Total Nozzel Flow 33

Sizing Valve

Type of vlave will be used

Minimum pipe size for flow with maximum 4 ft/sec velocity in pipes 2
Valve Model PGV Valve
Valve Type ###
Pressure Losses in Vlave ###

Note :
You can Use Valve different betweeen pipe size by 1 diameter

pipe size for flow with maximum 4 ft/sec velocity in pipes 1.5
Valve Model PGV Valve
Valve Type ###
Pressure Losses in Vlave ###
KLER ZONE 4
120 degree 180 degree 240 degree 270 degree 360 degree
T.GPM no. GPM T.GPM no. GPM T.GPM no. GPM T.GPM no. GPM T.GPM
0.34 1 0.45 0.45 0 0.68 0 1 0.73 0.73 0 0.8 0
0.44 1 0.6 0.6 0 0.88 0 1 1.1 1.1 0 1.26 0
0.39 1 0.58 0.58 0 0.78 0 1 0.87 0.87 0 1.16 0
0.65 0 0.98 0 0 1.31 0 1 1.47 1.47 0 1.96 0
0 0 1.26 0 0 1.68 0 0 1.89 0 0 2.52 0
0 0 1.86 0 0 2.48 0 0 2.79 0 0 3.72 0
0 0 2.4 0 0 3.2 0 0 3.6 0 5 4.8 24
1.82 1.63 0 4.17 24
33.05

inch
PGV Valve

inch
PGV Valve
SPRINKLER ZON
Type of irrigation in each zone
using adjustable nozzeles
45 degree 90 degree 120 degree
no. GPM T.GPM no. GPM T.GPM no. GPM
4A (" 4 foot radius") = 1 0.13 0.13 1 0.28 0.28 1 0.34
6A (" 6 foot radius") = 1 0.18 0.18 1 0.37 0.37 1 0.44
8A (" 8 foot radius") = 1 0.15 0.15 1 0.29 0.29 1 0.39
10A (" 10 foot radius") = 1 0.25 0.25 1 0.49 0.49 1 0.65
12A (" 12 foot radius") = 1 0.32 0.32 1 0.63 0.63 1 0.84
15A (" 15 foot radius") = 1 0.47 0.47 1 0.93 0.93 1 1.24
17A (" 17 foot radius") = 1 0.6 0.6 1 1.2 1.2 1 1.6
Total Angle Flow 2.1 4.19 5.5
Total Nozzel Flow 6

Sizing Valve

Type of vlave will be used PGV Jar-Top

Minimum pipe size for flow with maximum 4 ft/sec velocity in pipes 3
Valve Model PGV Jar-Top Valve
Valve Type ###
Pressure Losses in Vlave ###

Note :
You can Use Valve different betweeen pipe size by 1 diameter

pipe size for flow with maximum 4 ft/sec velocity in pipes 1.5
Valve Model PGV Jar-Top Valve
Valve Type ###
Pressure Losses in Vlave ###
KLER ZONE 5
120 degree 180 degree 240 degree 270 degree 360 degree
T.GPM no. GPM T.GPM no. GPM T.GPM no. GPM T.GPM no. GPM T.GPM
0.34 1 0.45 0.45 1 0.68 0.68 1 0.73 0.73 1 0.8 0.8
0.44 1 0.6 0.6 1 0.88 0.88 1 1.1 1.1 1 1.26 1.26
0.39 1 0.58 0.58 1 0.78 0.78 1 0.87 0.87 1 1.16 1.16
0.65 11 0.98 10.78 1 1.31 1.31 1 1.47 1.47 1 1.96 1.96
0.84 1 1.26 1.26 1 1.68 1.68 1 1.89 1.89 1 2.52 2.52
1.24 1 1.86 1.86 1 2.48 2.48 1 2.79 2.79 1 3.72 3.72
1.6 1 2.4 2.4 1 3.2 3.2 1 3.6 3.6 1 4.8 4.8
5.5 17.93 11.01 12.45 16.22
69.4

inch
PGV Jar-Top Valve

inch
PGV Jar-Top Valve
From Perevious Calculation We Got:-

Zone 1

Zone 1 Total Area 400 m2


Zone 1 Total GPM Require 37.85 GPM
Valve Model will be Used SRV Valve
Minimum Pipe Size Will be Used 2 Inch

Zone 2

Zone 2 Total Area 2100 m2


Zone 2 Total GPM Require 249.05 GPM
Valve Model will be Used PGV Jar-Top Valve
Minimum Pipe Size Will be Used 3 Inch

Zone 3

Zone 3 Total Area 600 m2


Zone 3 Total GPM Require 33.05 GPM
Valve Model will be Used SRV Valve
Minimum Pipe Size Will be Used 2 Inch

Zone 4

Zone 4 Total Area 300 m2


Zone 4 Total GPM Require 33.05 GPM
Valve Model will be Used PGV Valve
Minimum Pipe Size Will be Used 2 Inch

Zone 5

Zone 5 Total Area 900 m2


Zone 5 Total GPM Require 69.4 GPM
Valve Model will be Used PGV Jar-Top Valve
Minimum Pipe Size Will be Used 3 Inch

Calculating PR : -
96.3 * GPM Applied
PR =
AREA in FT2

PR For Zone 1 = 0.8 Inch/HR


PR For Zone 2 = 1.1 Inch/HR
PR For Zone 3 = 0.5 Inch/HR
PR For Zone 4 = 1 Inch/HR
PR For Zone 5 = 0.7 Inch/HR

To Calculate Irrigation Time For Each Zone

60 * ET * KC
T =
PR * EA

Where :-
T= Irrigation Time in Min
ET = Aveporationsipiration Rate
KC = Crop Coeffecient
PR = Precipration Rate
EA = Application Coeffecient

Evaporate Rate :-
Day Losses in Inch
Hot Day
Got Evaporate Rate = 0.35 Inch/Day

Crop Coeffecient
Vines & Shrubs
Got Crop Coeffecient = 0.7 Inch/Day

Moisture Avaliable
Site Loam
Got Moisture Avaliable = 2.25 Inch/Feet Soil Depth

Apllication Coeffecient Average 65 % = 0.65

Got Timing For Each Zone

Zone 1 = 28 Min/Day
Zone 2 = 21 Min/Day
Zone 3 = 45 Min/Day
Zone 4 = 23 Min/Day
Zone 5 = 32 Min/Day

For Differnet days of Irrigation

Insert days of Irrigation 6 Day

Zone 1 = 33 Min/Day
Zone 2 = 25 Min/Day
Zone 3 = 53 Min/Day
Zone 4 = 27 Min/Day
Zone 5 = 37 Min/Day
Drip Line Calculation
Dipe line changed according it`s type 0.4 GPH, 0.6 GPH, 1.00 GPH

Type of drip line will be used 1.0 GPH Emitter

Maximum Distance Between Emitter 24 inch

distance between emitter 24 Inch


Drip line Total Length in meter 30.5 Meter
No. of Emitter Per Line 50 Emitter
Total Flow For The Line = No. of Emitter X Flow Per Emitter
50 x 1 = 50 GPH
0.83 GPM
Average water Requirement per day for different type of plant

Weather type Cool Climate

Plant Required
NO./area Weather
Mature Canopy Dia. Gallon
Small Shrubs
30 0.3 9
3ft/91 cm
Large Shrubs
20 0.7 14
5ft/1.52 cm
Small Tree
0 2.7 0
10 ft/3.05 cm
Large Tree
0 10.9 0
20ft/6.10 m
Ground Cover 1
0 0
per area in m2 inch/day
Bedding Plants 1
0 0
per area inch/day
Container
0 0.2 0
Small
Container
0 0.3 0
Large

Total Required Gallons 23

Operating Time Total Required Gallons / Avaliable gpm


Operating Time 23 / 0.83
= 28 Min/Day

Main Suction Pipe Line Diameter 1 Inch Inlet Pipe

Drip Zone Controller


Selected Drip Zone Controller = PCZ-101
Drip Line Calculation
Dipe line changed according it`s type 0.4 GPH, 0.6 GPH, 1.00 GPH

Type of drip line will be used 1.0 GPH Emitter

Maximum Distance Between Emitter 12 inch

distance between emitter 12 Inch


Drip line Total Length in meter 30.5 Meter
No. of Emitter Per Line 100 Emitter
Total Flow For The Line = No. of Emitter X Flow Per Emitter
100 x 1 = 100 GPH
1.67 GPM
Average water Requirement per day for different type of plant

Weather type Cool Climate

Plant Required
NO./area Weather
Mature Canopy Dia. Gallon
Small Shrubs
30 0.3 9
3ft/91 cm
Large Shrubs
20 0.7 14
5ft/1.52 cm
Small Tree
0 2.7 0
10 ft/3.05 cm
Large Tree
0 10.9 0
20ft/6.10 m
Ground Cover 1
0 0
per area in m2 inch/day
Bedding Plants 1
0 0
per area inch/day
Container
0 0.2 0
Small
Container
0 0.3 0
Large

Total Required Gallons 23

Operating Time Total Required Gallons / Avaliable gpm


Operating Time 23 / 1.67
= 14 Min/Day

Main Suction Pipe Line Diameter 3/4 Inch Inlet Pipe

Drip Zone Controller


Selected Drip Zone Controller = ACZ-0.75
Drip Line Calculation
Dipe line changed according it`s type 0.4 GPH, 0.6 GPH, 1.00 GPH

Type of drip line will be used 0.4 GPH Emitter

Maximum Distance Between Emitter 12 inch

distance between emitter 12 Inch


Drip line Total Length in meter 30.5 Meter
No. of Emitter Per Line 100 Emitter
Total Flow For The Line = No. of Emitter X Flow Per Emitter
100 x 0.4 = 40 GPH
0.67 GPM
Average water Requirement per day for different type of plant

Weather type Cool Climate

Plant Required
NO./area Weather
Mature Canopy Dia. Gallon
Small Shrubs
30 0.3 9
3ft/91 cm
Large Shrubs
20 0.7 14
5ft/1.52 cm
Small Tree
0 2.7 0
10 ft/3.05 cm
Large Tree
0 10.9 0
20ft/6.10 m
Ground Cover 1
0 0
per area in m2 inch/day
Bedding Plants 1
0 0
per area inch/day
Container
0 0.2 0
Small
Container
0 0.3 0
Large

Total Required Gallons 23

Operating Time Total Required Gallons / Avaliable gpm


Operating Time 23 / 0.67
= 35 Min/Day

Main Suction Pipe Line Diameter 3/4 Inch Inlet Pipe

Drip Zone Controller


Selected Drip Zone Controller = ACZ-0.75
Drip Line Calculation
Dipe line changed according it`s type 0.4 GPH, 0.6 GPH, 1.00 GPH

Type of drip line will be used 0.6 GPH Emitter

Maximum Distance Between Emitter 24 inch

distance between emitter 24 Inch


Drip line Total Length in meter 30.5 Meter
No. of Emitter Per Line 50 Emitter
Total Flow For The Line = No. of Emitter X Flow Per Emitter
50 x 0.6 = 30 GPH
0.5 GPM
Average water Requirement per day for different type of plant

Weather type Cool Climate

Plant Required
NO./area Weather
Mature Canopy Dia. Gallon
Small Shrubs
30 0.3 9
3ft/91 cm
Large Shrubs
20 0.7 14
5ft/1.52 cm
Small Tree
0 2.7 0
10 ft/3.05 cm
Large Tree
0 10.9 0
20ft/6.10 m
Ground Cover 1
0 0
per area in m2 inch/day
Bedding Plants 1
0 0
per area inch/day
Container
0 0.2 0
Small
Container
0 0.3 0
Large

Total Required Gallons 23

Operating Time Total Required Gallons / Avaliable gpm


Operating Time 23 / 0.5
= 46 Min/Day

Main Suction Pipe Line Diameter 1 Inch Inlet Pipe

Drip Zone Controller


Selected Drip Zone Controller = PCZ-101
Drip Line Calculation
Dipe line changed according it`s type 0.4 GPH, 0.6 GPH, 1.00 GPH

Type of drip line will be used 0.6 GPH Emitter

Maximum Distance Between Emitter 24 inch

distance between emitter 24 Inch


Drip line Total Length in meter 30.5 Meter
No. of Emitter Per Line 50 Emitter
Total Flow For The Line = No. of Emitter X Flow Per Emitter
50 x 0.6 = 30 GPH
0.5 GPM
Average water Requirement per day for different type of plant

Weather type Cool Climate

Plant 0.25
NO./area Weather
Mature Canopy Dia. Gallon
Small Shrubs
30 0.3 9
3ft/91 cm
Large Shrubs
20 0.7 14
5ft/1.52 cm
Small Tree
0 2.7 0
10 ft/3.05 cm
Large Tree
0 10.9 0
20ft/6.10 m
Ground Cover 1
0 0
per area in m2 inch/day
Bedding Plants 1
0 0
per area inch/day
Container
0 0.2 0
Small
Container
0 0.3 0
Large

Total Required Gallons 23

Operating Time Total Required Gallons / Avaliable gpm


Operating Time 23 / 0.5
= 46 Min/Day

Main Suction Pipe Line Diameter 1 Inch Inlet Pipe

Drip Zone Controller


Selected Drip Zone Controller = PCZ-101
From Perevious Calculation We Got:-

Zone 1
Zone 1 Total GPM Require 0.83 GPM
Valve Model will be Used PCZ-101
Operating time 28 Min/Day
Drip line lengthn in feet 100 Ft
No. of Emitter in line 50 Emitter
Distance Between Emitter 24 X 24 Inch

Zone 2
Zone 2 Total GPM Require 1.67 GPM
Valve Model will be Used ACZ-0.75
Operating time 14 Min/Day
Drip line lengthn in feet 100 Ft
No. of Emitter in line 100 Emitter
Distance Between Emitter 12 X 12 Inch

Zone 3
Zone 3 Total GPM Require 0.67 GPM
Valve Model will be Used ACZ-0.75
Operating time 35 Min/Day
Drip line lengthn in feet 100 Ft
No. of Emitter in line 100 Emitter
Distance Between Emitter 12 X 12 Inch

Zone 4
Zone 4 Total GPM Require 0.5 GPM
Valve Model will be Used PCZ-101
Operating time 46 Min/Day
Drip line lengthn in feet 100 Ft
No. of Emitter in line 50 Emitter
Distance Between Emitter 24 X 24 Inch

Zone 5
Zone 4 Total GPM Require 0.5 GPM
Valve Model will be Used PCZ-101
Operating time 46 Min/Day
Drip line lengthn in feet 100 Ft
No. of Emitter in line 50 Emitter
Distance Between Emitter 24 X 24 Inch
Bubblers Calculation
Bubbler changed according it`s type 0.25 GPM, 0.50 GPM, 1.00 GPM,2.00 GPM

Water Requiredment for Plant :-

Plant Water Required


NO
Mature Canopy Dia. Required /Plant Gallon
0.5 GPM
Small Tree 2 8 16
better
Large Tree 2.0 GPM
2 32 64
Palm Tree better
Evergreen and 1.0 GPM
2 16 32
Ordinary Trees better

Total Gallon 112

Bubbler Type Used for Small Trees 0.50 GPM Bubbler


Bubbler Flow GPM 0.5
Bubbler Type Used for Large Trees 2.00 GPM Bubbler
Bubbler Flow GPM 2
Bubbler Type Used for Evergreen 1.00 GPM Bubbler
Bubbler Flow GPM 1

Total flow in GPM 7

Operating Time Total Required Gallons / Avaliable gpm


Operating Time 112 / 7
= 16 Min/Day

Bubbler Zone 1
Bubblers Calculation
Bubbler changed according it`s type 0.25 GPM, 0.50 GPM, 1.00 GPM,2.00 GPM

Water Requiredment for Plant :-

Plant Water Required


NO
Mature Canopy Dia. Required /Plant Gallon
0.5 GPM
Small Tree 5 8 40
better
Large Tree 2.0 GPM
5 32 160
Palm Tree better
Evergreen and 1.0 GPM
5 16 80
Ordinary Trees better

Total Gallon 280

Bubbler Type Used for Small Trees 2.00 GPM Bubbler


Bubbler Flow GPM 2
Bubbler Type Used for Large Trees 2.00 GPM Bubbler
Bubbler Flow GPM 1
Bubbler Type Used for Evergreen 2.00 GPM Bubbler
Bubbler Flow GPM 2

Total flow in GPM 25

Operating Time Total Required Gallons / Avaliable gpm


Operating Time 280 / 25
= 12 Min/Day

Bubbler Zone 2
Bubblers Calculation
Bubbler changed according it`s type 0.25 GPM, 0.50 GPM, 1.00 GPM,2.00 GPM

Water Requiredment for Plant :-

Plant Water Required


NO
Mature Canopy Dia. Required /Plant Gallon
0.5 GPM
Small Tree 5 8 40
better
Large Tree 2.0 GPM
5 32 160
Palm Tree better
Evergreen and 1.0 GPM
5 16 80
Ordinary Trees better

Total Gallon 280

Bubbler Type Used for Small Trees 1.00 GPM Bubbler


Bubbler Flow GPM 1
Bubbler Type Used for Large Trees 1.00 GPM Bubbler
Bubbler Flow GPM 1
Bubbler Type Used for Evergreen 2.00 GPM Bubbler
Bubbler Flow GPM 2

Total flow in GPM 20

Operating Time Total Required Gallons / Avaliable gpm


Operating Time 280 / 20
= 14 Min/Day

Bubbler Zone 3
Bubblers Calculation
Bubbler changed according it`s type 0.25 GPM, 0.50 GPM, 1.00 GPM,2.00 GPM

Water Requiredment for Plant :-

Plant Water Required


NO
Mature Canopy Dia. Required /Plant Gallon
0.5 GPM
Small Tree 5 8 40
better
Large Tree 2.0 GPM
5 32 160
Palm Tree better
Evergreen and 1.0 GPM
5 16 80
Ordinary Trees better

Total Gallon 280

Bubbler Type Used for Small Trees 0.25 GPM Bubbler


Bubbler Flow GPM 0.25
Bubbler Type Used for Large Trees 1.00 GPM Bubbler
Bubbler Flow GPM 1
Bubbler Type Used for Evergreen 2.00 GPM Bubbler
Bubbler Flow GPM 2

Total flow in GPM 16.25

Operating Time Total Required Gallons / Avaliable gpm


Operating Time 280 / 16.25
= 18 Min/Day

Bubbler Zone 4
Bubblers Calculation
Bubbler changed according it`s type 0.25 GPM, 0.50 GPM, 1.00 GPM,2.00 GPM

Water Requiredment for Plant :-

Plant Water Required


NO
Mature Canopy Dia. Required /Plant Gallon
0.5 GPM
Small Tree 5 8 40
better
Large Tree 2.0 GPM
5 32 160
Palm Tree better
Evergreen and 1.0 GPM
5 16 80
Ordinary Trees better

Total Gallon 280

Bubbler Type Used for Small Trees 0.50 GPM Bubbler


Bubbler Flow GPM 0.5
Bubbler Type Used for Large Trees 0.25 GPM Bubbler
Bubbler Flow GPM 0.25
Bubbler Type Used for Evergreen 2.00 GPM Bubbler
Bubbler Flow GPM 2

Total flow in GPM 13.75

Operating Time Total Required Gallons / Avaliable gpm


Operating Time 280 / 13.75
= 21 Min/Day

Bubbler Zone 5
From Perevious Calculation We Got:-

Zone 1
Zone 1 Total GPM Require 7 GPM
Operating time 16 Min/Day
0.845154
Minimum Delivery Pipe line 1 Inch
Valve to be used PCZ-101

Zone 2
Zone 2 Total GPM Require 25 GPM
Operating time 12 Min/Day
1.597191
Minimum Delivery Pipe line 2 Inch
Valve to be used ICZ-151

Zone 3
Zone 3 Total GPM Require 20 GPM
Operating time 14 Min/Day
1.428571
Minimum Delivery Pipe line 1.5 Inch
Valve to be used ICZ-101

Zone 4
Zone 4 Total GPM Require 16.25 GPM
Operating time 18 Min/Day
1.287697
Minimum Delivery Pipe line 1.5 Inch
Valve to be used ICZ-101

Zone 5
Zone 5 Total GPM Require 13.75 GPM
Operating time 21 Min/Day
1.184509
Minimum Delivery Pipe line 1.5 Inch
Valve to be used PCZ-101
Schedule of Irrigation

Station Valves Flow Operating


Time
ZONE 1 SPRINKLER 37.85 28
0 0
A1 0 0
0 0
0 0
ZONE 3 SPRINKLER 33.05 45
0 0
A2 0 0
0 0
0 0
ZONE 1 DRIPER 37.85 28
0 0
A3 0 0
0 0
0 0
ZONE 1 BUBBLER 7 16
0 0
A4 ZONE 5 BUBBLER 13.75 21
0 0
0 0
ZONE 4 SPRINKLER 33.05 23
0 0
A5 0 0
0 0
0 0
0 0
ZONE 1 DRIPER 0.83 28
A6 ZONE 3 DRIPER 0.67 35
ZONE 1 BUBBLER 7 16
ZONE 2 DRIPER 1.67 14
0 0
0 0
A7 0 0
0 0
0 0
0 0
0 0
A8 0 0
0 0
0 0
PUMP MAXIMUM FLOW IN GPM
Total Station Start Time Shut Time Operating Time in
Flow Min

37.85 10:00 PM 10:28 PM 00:28

33.05 10:28 PM 11:13 PM 00:45

37.85 11:13 PM 11:41 PM 00:28

20.75 11:41 PM 12:02 AM 00:21

33.05 12:02 AM 12:25 AM 00:23

10.17 12:25 AM 1:00 AM 00:35

0 1:00 AM 1:00 AM 00:0

0 1:00 AM 1:00 AM 00:0


37.85 Total Irrigation Time 3:00
From Schedule of Operating time got:

- Maximum Station Flow = 38 GPM


- Maximum Operating Time = 3:00 Hours
- Maximum Distance From Pump
To farest Point = 60 Meter
- Static head = 1.5 Meter

- Pump Pressure = 1.2*( Static head + 4/100 * distance between pump


& farest irr. Point + 25 )
= 1.2 * ( 1.5 + 60 * 4 / 100 + 25 )
= 34.68 Meter
= 50 PSI

- No. of Duty Pumps = 3 Pump


- No. of Standby Pumps = 1 Pump

Pump Selection
Pump Flow 13 GPM
Pump Pressure 50 PSI
Pump Power Supply 0.6 HP
Maximum Operating Time 3:00 Hours
No. of Pumps 3 Duty 1 Standby