WCDMA RNO Single Site Verification Guide: Huawei Technologies Co., LTD
WCDMA RNO Single Site Verification Guide: Huawei Technologies Co., LTD
Revision Records
2007-12-11 Huawei Confidential. No Spread Without Page 1 of 10
Permission.
WCDMA RNO Single Site Verification Guide
Revised
Date Description Author
version
To distinguish the call drop and access problems due to poor coverage from those
due to equipment performance. This helps locate and solve problems in early
stages, and raise efficiency of network optimization.
To ensure that the services to be tested are provided by the cell to be measured, you
must test cell equipment functions by selecting a test point meeting the following
conditions:
Where the signals of target cell are strong
Where the signals of other cells are weak
To ensure that the services to be tested are provided by the cell to be measured, the
most ideal method is to disable power amplifiers of other cells except the cell to be
measured. In this situation, no requirements are on the testing points.
If you cannot disable the power amplifier of other cells, select a testing point near the
center of the cell, with line-of-sight distance to the NodeB. In this way, the signals are
strong enough and do not fluctuate. For a macro cell, select a testing point 100 meters
from NodeB in the direction of major transmission of cell antenna, with line-of-sight
distance to NodeB.
Set the handset to testing mode before test. For different types of handset, the method
for starting testing mode is different. For Huawei U626, press the keys * and #, as well as
left navigation key in the same time to start engineering mode, and this serves for locking
frequency. Press the application key to starting testing mode, as shown in 3.1.21
Application key
Figure 1.3 Method for starting testing mode of Huawei U626 test UE
Besides the tasks mentioned previously, you must complete the following tasks:
Check from the operator's optimization engineers whether the power transmission of
each site is allowed
Obtain the number of test UE
Check whether the UE is a test UE in engineering mode or uses a data card and
whether the UE power is enough
Print the test table
Familiarize the following information about NodeB before test, including:
Site location
Cell ID
Scramble
Omnidirectional/Directional site
Azimuth
I. Aim
Check whether the frequency number of the cell to be measured is consistent with the
planned data.
II. Method
According to the method mentioned in 3.1.1, press the application key to start testing
mode of the handset. Then the handset displays testing mode.
Query ②WCDMA-Network Information, and the handset displays the basic information
of the serving network, including the uplink and downlink frequency number.
III. Remarks
Check whether the ID of the serving cell (CI) is consistent with the planned one in
frequency check. If not, the UE might receive signals from other cells.
2) If the ID of the serving cell is consistent with the planned one, you do as below:
Move the UE to a location with stronger signals and wait for two minutes. If the
measured CI is inconsistent with the planned one, the UE does not reselect a cell.
You must power off the UE, and then power on the UE to ensure that the UE camps
on the cell with strongest signals, namely, the primary serving cell. Only when both
the frequency and CI are consistent can the test pass.
3) If the ID of the serving cell is inconsistent with the planned one, you do as below:
You must lock frequency. For Huawei U626 handset, press the keys * and #, as well
as the left navigation key at the same time to start engineering mode. Press
⑧Locking Frequency, and then ①Start Locking Frequency. After typing the
frequency point, click OK to complete locking frequency. After frequency locking,
you must restart testing mode. If the frequency and CI are consistent, the single site
verification test passes.
If you cannot find the serving CI for a long time, possibly the signals of the primary
serving cell are transmitted abnormally, and the antenna-feeder are reversely connected.
You must adjust them and then restart the test.
I. Aim
Check whether the scramble configuration is consistent with the planned configuration.
II. Method
III. Remarks
Based on consistency of CI, check whether the P-SC is consistent with the planned one.
If yes, the site passes the test. If no, you must readjust and retest.
I. Aim
Check whether the LAC/RAC of the cell to be measured is consistent with the planed
one.
II. Method
III. Remarks
If the measured LAC/RAC is consistent with the planned one, the site passes test. If not,
you must readjust and retest.
I. Aim
Check whether the CPICH RSCP and CPICH Ec/Io received by UE are greater than the
threshold. Check whether there are problems, such as abnormal power amplifier,
abnormal connection of antenna-feeder, inconsistent of antenna tilt/azimuth from the
planned one, and blocking by buildings.
II. Method
In the major transmission direction of antenna, fix a location with line-of-sight distance
from the antenna within 100 meters from the NodeB.
Power on the test UE and start testing mode by pressing the application key.
Query ①WCDMA-Power/RRC, and the handset displays the information about the
received signals, including the received signal strength Rx (CPICH_RSCP) and the
received signal-to-interference radio (SIR) (CPICH Ec/Io).
III. Remarks
The threshold of CPICH RSCP and CPICH Ec/Io are related to site types (macro cell,
micro cell) and loading conditions. You must determine them according to the actual
situations.
For macro cells, CPICH RSCP > –70 dBm.
For micro cells, CPICH RSCP > –60 dBm.
For no-load cells, CPICH Ec/Io > –6 dB.
For load-on cells, CPICH Ec/Io > –10 dB.
If the operator also runs a 2G network and the 3G sites and 2G sites share sites, you can
compare the coverage of corresponding 2G sites for checking signal coverage problems.
If no special note is for a cell, the related CPICH RSCP: –75 dBm, CPICH Ec/Io: –8 dB.
If CPICH RSCP < –75dBm, you must check for the following problems:
Abnormal power amplifier
Abnormal connection of antenna-feeder
Inconsistency of antenna tile/direction angle from planned one
Blocking by buildings
If CPICH Ec/Io < –8dB (when loading, the CPICH Ec/Io < –10dB), you must inform of
RNO engineers.
I. Aim
Check whether the originating and terminating function of voice service function normally
by call quality test (CQT).
II. Method
Use two handsets to call each other for five times. Record the originating and terminating
connection conditions,
III. Remarks
If the originating or terminating handset fails, you must locate to solve the problem and
retest it.
I. Aim
Check whether the originating and terminating function of VP service function normally
by call quality test (CQT).
2007-12-11 Huawei Confidential. No Spread Without Page 8 of 10
Permission.
WCDMA RNO Single Site Verification Guide
II. Method
Use two handsets to call each other for five times. Record the originating and terminating
connection conditions,
III. Remarks
If the originating or terminating handset fails, you must locate to solve the problem and
retest it.
I. Aim
Check whether the originating function of PS services are normal by handset online
service.
II. Method
Before test, check whether you can go online with the test UE in normal cells. If the
handset is available for online service, type the website address in the browser. It is a
symbol for connection of PS services that the handset is available for online services and
browsing web pages.
The method for Huawei U626 handset to browse online is below:
4) Select Main Menu > Data Connection > Data Account. Check the IP address of
data account. Ensure than the access point name (APN) is correctly configured. For
example, the ANP for Chine Mobile Monternet is cmwap.
5) Select Main Menu > Browser > Selecting Network Settings. Select the network
settings, press Edit and the handset displays the editing interface. You can editing
the following items:
Homepage: type the website address entitled "http://"
WAP gateway: if there is a WAP gateway, type the IP address, IP port
number, user name, and password. If not, neglect it
Timeout: the default out time is 60s
Data account: select as described in II
Connection type: select HTTP
6) Select Main Menu > Browser > Homepage. Select OK to browse the homepage. If
no homepage address is in Network Settings, or you aim to browse other web
pages, select Main Menu > Browser > Typing Website Address. After typing a
website address, select OK. Then you can browse the specified web page.
The method for Moto A835 handset to browse online is below:
1) Edit online settings.
Select Menu > Tools > Web Access > Web Sessions. Move the cursor to the
target web session, press , and a menu is displayed. Select Edit to edit online
settings as below:
Homepage: type homepage address excluding "http://"
Service Type1: HTTP
Service Type2: WAP
Port1: 8080
GPRS APN: for example, the APN for China Mobile Monternet is cmwap.
2) Select Menu > Tools > Web Access > Web Sessions. Select Launch to browse
the specified web page.
III. Remarks
If you can browse the specified web page with the UE in the cell to be measured, the site
passes the test. If not, the PS services are unavailable and you must location to retest.
Si ngl e Si te
Veri fi cati on Checkl i st.xl s