英文12kV W-VACi 150dpi PDF
英文12kV W-VACi 150dpi PDF
Automotive
Powering
business
worldwide
Aerospace
Type of Product
Features of Product
• High end 3D Computer Aided Design (Pro-Engineer) and
Dynamic stimulation optimized design (Pro-Mechanical).
• Electromagnetic field distribution designs minimize the partial
discharge and overheat.
Closing Charging
• The most advanced, high performance Eaton vacuum interrupter
Spring Motor
provides excellent performances of breaking heavy-duty
currents.
• Excellent, reliable Encapsulated insulation performance is safely Manual Operating
used for severe environment. charging hand Coil
• Reliable earthing mode ensures earthing continuity from
working position to test position.
Auxiliary Operating
• Consistent design are entirely compatible with various main
Switch Panel
stream switchgear.
• Various Accessory solutions fully satisfy user's various
demands.
• Spring operating mechanism. adopts modular design, with
higher interchangability.
• Features of spring operating mechanism:
Rated Voltage kV 12 12 12 12 12 12 12 12 12 12
Rated Power Frequency
Rated Insul- Withstand Voltage kV 42 42 42 42 42 42 42 42 42 42
-ation Level Rated Lightning Impulse
Withstand Voltage kV 75 75 75 75 75 75 75 75 75 75
Rated Frequency Hz 50 50 50 50 50 50 50 50 50 50
Rated Short-Circuit kA 25 25 31.5 31.5 40 40 40 40 50 50
Breaking Current
D.C. Component % 45.9 45.9 45.9 45.9 47 33 33 33 33
of Breaking Current 47
630 1250 630 1250 1250 1600 2500 3150 2000 2500
Rated Current A
1600 2000 4000(2) 3150 4000(2)
Electrical Endurance E2 E2 E2 E2 E2 E2 E2 E2 E2 E2
times
(274/30) (274/30) (274/30) (274/30) (274) (274) (274) (274) (274) (274)
Mechanical Endurance times 30000 30000 30000 30000 20000 20000 20000 20000 10000 10000
Clearance Between Open Contacts (gap) mm 9.5±0.5 9.5±0.5 9.5±0.5 9.5±0.5 8.5±1 8.5±1 8.5±1 8.5±1 8.5±1 8.5±1
Overtravel mm 3±1 3±1 3±1 3±1 3±1 3±1 3±1 3±1 3±1 3±1
Closing Speed m/s 0.7~1.3 0.7~1.3 0.7~1.3 0.7~1.3 0.7~1.3 0.7~1.3 0.7~1.3 0.7~1.3 0.7~1.3 0.7~1.3
Opening Speed m/s 1.0~1.7 1.0~1.7 1.0~1.7 1.0~1.7 1.0~1.7 1.0~1.7 1.0~1.7 1.0~1.7 1.0~1.7 1.0~1.7
Bouncing Time ms ≤2 ≤2 ≤2 ≤2 ≤2 ≤2 ≤2 ≤2 ≤2 ≤2
ms ≤2 ≤2 ≤2 ≤2 ≤2 ≤2 ≤2 ≤2 ≤2 ≤2
Closing Time ms 25~50 25~50 25~50 25~50 25~50 25~50 25~50 25~50 25~50 25~50
Opening Time ms 40~60 40~60 40~60 40~60 40~60 40~60 40~60 40~60 40~60 40~60
Pole to Pole Distance (Center to Center) mm 150/210 150/210 150/210(3) 150/210 210/275 210/275 275 275 275 275
Operation Sequence O-0.3s O-0.3s O-0.3s O-0.3s O-0.3s O-0.3s O-0.3s O-0.3s O-0.3s O-0.3s
- CO - CO - CO - CO - CO - CO - CO - CO - CO - CO
-180s -180s -180s -180s -180s -180s -180s -180s -180s -180s
- CO - CO - CO - CO - CO - CO - CO - CO - CO - CO
Classification C2-E2-M2 C2-E2-M2 C2-E2-M2 C2-E2-M2 C2-E2-M2 C2-E2-M2 C2-E2-M2 C2-E2-M2 C2-E2-M2 C2-E2-M2
(1) Rated short-circuit current Rated peak withstand current 100KA 110KA optional.
(2) 4000A need forced cooling.
(3)
1600A/31.5KA breaker phase distance is only 210mm.
Normal working voltage range 80%~110% of Rated voltage 80%~110% of Rated voltage 80%~110% of Rated voltage 80%~110% of Rated voltage
Rated current(A) ≤3 ≤2 ≤3 ≤4
Closing release: 80%~110% of Rated voltage;
Normal working voltage range*
Opening release: 65%~120% of Rated voltage
*If user has special request, please contact us
150mm 500mm
210mm 650mm
275mm 850mm
630~1250A 150kg
1250~2000A 240kg
2500~3150A 290kg
Storage
• Products shall be stored indoors with proper dry condition and necessary ventilation, and without serious pollution, chemical corrosion,
violent vibration.
Accessory:
Draw-out Type:
Fixed type:
As required
As required
50 2000(1) Ф79
Note:
(1) Do not use a cooling rack corresponding parameter.
(2) Parameters corresponding to the cooling rack.
(3) 4000A need forced cooling.
120 W-VACi
1250A 31.5kA 210mm Fixed type
As required
120 W-VACi
2000A 40kA 275mm Fixed type
As required
As required
Optional Optional
Optional Optional
T 58-pin secondary plug S1,S2 Auxiliary switch (switching when breakers open and close)
UVR Undervoltage release(optional) S8,S9 Trolley position switch (charging when breakers in working and test positions)
V1,V2 ,V3,V4 ,V5 Rectifier block PCB4 Undervoltage circuit board (AC/DC)
PCB1 Storing energy circuit board (AC/DC)
PCB2 Closing circuit board (AC/DC)(integrated closing
and anti-pumping functions)
PCB3 Second opening circuit board (AC/DC) Note: 1、breakers in testing position,energy not stored,free trip connecting rod not in rest status
2、 this circuit can be used to indicate the breaker is not in energy-stored status
3、 this circuit can be used to indicate the breaker is in energy-stored status
4、 this circuit can be used to indicate the breaker is closing status
5、 this circuit can be used to indicate the breaker is opening status
6、 optional circuit with or without anti-pumping funtion. For details,pleaser refer to schematic diagram
If customers cancel anti-pumping by themselves, Eaton shall not take any responsibility
in case of breaker's operational faults
14
12kV W-VACi Series Medium Voltage Vacuum Circuit Breaker
1. Type
Opening release power supply □AC110V □AC220V □DC110V □DC220V □DC48V □DC24V
Closing release power supply □AC110V □AC220V □DC110V □DC220V □DC48V □DC24V
Charging motor power supply □AC110V □AC220V □DC110V □DC220V □DC48V □DC24V
4. Optional accessory
Optional accessory □Trolley latching electromagnet □Under-voltage tripping release □Shunt tripping release
Draw-out Type Accessory □Circuit Breakers auxilary disconnect □Trolley racking tool
Fixed Type Accessory □Circuit Breakers auxilary terminals
1874 1886 1893 1899 1906 1908 1911 1934 1962 1963 1976 1983 1990 1999