Boscoseal Ac2 PDF
Boscoseal Ac2 PDF
Application requiring access onto moist, `green' or Once the innitial coating is dry, recoat the entire area
uncured concrete will first require the application of to be waterproofed, including full cover over the initial
Bostik Moisture Seal epoxy vapour barrier which will act coating.
as a curing compound and moisture transmission barrier.
wet area floor & external decks
Bostik Moisture Seal must be applied in a two-coat applications
system as per Technical Data Sheet. Boscoseal AC2 must Primer applications must be dry.
be applied immediately the second coat `tack off'.
If the wet area floor, balcony or deck areas to be coated
If Boscoseal AC2 cannot be applied within 24 hours of the are subject to service or other building penetrations,
second coat of Moisture Seal curing, a third coat must be it is recommended, if possible, to install a flange metal
applied. up stand around the penetration. Prime metal up stand
cracks & narrow joint sealing with Bostik 5077 primer and seal off the perimeter of the
All cracks must be cleaned with loose material removed. penetration with a 10mm bead of Bostik Neutral Cure
Silicone.
For cracks and joints up to 5mm, apply a bead of Bostik
Neutral Cure Silicone into the crack and extending 5mm Apply Boscoseal AC2 into wastes, drains or onto puddle
either side. Tool smooth with spatula. Once the silicone flanges. Boscoseal AC2 must be dressed down into the
is tack free, prime the repaired area with Bostik AC waste at least 50mm.
Primer to a width of 150mm each side of repair. Allow
AC Primer to dry approximately 30 minutes. Apply two Apply a initial coat of Boscoseal AC2 either side of all
coats of Boscoseal AC2 over the primed area achieving a wall/floor junctions and sheet flooring joints. Extend the
minimum dry film thickness of 1.2mm. coating at least 100mm either side of the joints.
Cracks over 5mm must be repaired and designed Once the initial coating is dry, recoat the entire floor area
with movement joints sealed as detailed in substrate to be waterproofed, including over the initial coating.
preparation section. ROOF APPLICATIONS
Boscoseal AC2 is recommended as a waterproof
internal wet areas :
sealing corners & waste outlets membrane for non-traffic areas. Application method is
Do not use Polyurethane based sealants in these the same as for wet area floors/decks.
applications.
These areas of application should not be accessed until
Ensure fall required in the screed to shower recess base, membrane has fully cured.
pipe outlets, angles and drainage is installed correctly. TILING AND MORTAR BED COVERING
To eliminate possible surface contamination or damage,
All corners and substrate gaps around taps, shower it is recommended tiling, mortar bed application or
outlets, waste outlets, pipes, drains, flashings and nail/ finished flooring installation be carried out it as soon
screw holes must be sealed using Bostik Neutral Cure as possible after full cure of the membrane. These
Silicone or Simson SMP sealants. installations may be carried out after the Boscoseal
AC2, two-coat system has been allowed to cure for a
Apply a 10mm bead of sealant by caulking gun directly minimum of 3 days at a temperature of 25oC (slightly
into all wall/floor, hob/floor, hob/wall and wall/wall longer in lower temperatures).
corners to intending tile height.
Movement joints provided in tiling should be filled with
Sealant should be spatula tooled smooth around fittings either Bostik Seal `N' Flex 1 or FC Polyurethane sealant or
and pressed into corners creating a triangular fillet. Allow Bostik neutral cure anti-fungal silicone sealant.
sealant to tack off (approximately 30 minutes).
tile adhesive
Apply primer after sealant tack off, to all areas intended Bostik tile adhesives such as Ultra Mastik, Excelflex or
PAGE 2 OF 3
Fixall mixed with Hydroment 425 and/or equal may CLEAN UP
be used. Tile adhesive used shall be recommended Thoroughly clean all tools and equipment with water after
and applied in strict compliance with manufacturer's use.
instructions.
STORAGE ADN SHELF LIFE
PRECAUTIONS Store in original sealed container under cover and dry
• Ponding test should be carried out after full curing conditions. Boscoseal AC2 has a shelf life of 12 months in
(7 days). original unopened container if stored between 5oC and
• Do not apply where surface temperature is below 35oC. Do not freeze.
10oC or greater than 35oC.
HEALTH AND SAFETY
• Boscoseal AC2 is neither a vapour barrier nor
If swallowed, do not induce vomitting. Give a glass of
designed to stop hydrostatic head of water
water, contact a doctor or Poisons Information Centre.
pressure. For this application, Bostik Moisture Seal
For more detail information refer to Material Safety Data
should be used.
Sheet.
• Do not apply on wet, contaminated or friable
substrates. Limited Warranty
• Do not apply externally if raining or rain is imminent. The information and recommendations relating to the
• Do not apply to surfaces with protective coatings application and end-use of the product are given in good
without prior consultation with Bostik. faith and based on tests which we believe to be reliable.
• The rate of cure will be dramatically reduced when However, no warranty in respect of merchantability
air or substrate temperatures are below +10oC or if or of fitness for a particular purpose, nor any liability
apply over a vapour barrier or untreated concrete. arising out of any legal relationship, whatsoever, can
• The application rate of Boscoseal AC2 should not be inferred either from this information, or from any
be extended over the recommended coverage of written recommendations, or from any other advise
1 litre per square metre or under 0.8mm wet film offerred. No guarantee of their accuracy can be made
thickness in one application. because of the great range of field conditions and
• A third coat of Boscoseal AC2 may be necessary if variation encountered in raw materials, manufacturing
imperfections in the cured membrane are present. equipment and methods. Thus, the products are sold
• Do not dilute with water or extend with with limited warranty only, and on condition that
cementitiuos powders or other additives. purchasers will make their own tests to determine the
• Boscoseal AC2 requires atmospheric conditions to suitability of the product for their particular purposes.
cure. It should not be used in totally confined or air Under no circumstances will Bostik be liable to anyone
free spaces. except for replacement of the products or refund of the
• Boscoseal AC2 should not be used as a wearing purchase price.
surfaces for heavy foot traffic or vehicle traffic.
• Do not apply over treated pipe.
• Totally impervious substrates such as epoxies and
rigid fibreglass require priming.
• Do not apply Boscoseal AC2 at RC Tanking structure
areas, eg : water tank, swimming pool, water
features pond, planter box and etc.
• Boscoseal AC2 will not span gaps and should only be 032-091-2158
Environmentally Preferred Coating
applied to continuous surfaces.
• Boscoseal AC2 water based membrane must not
come in direct contact with Polyurethane sealants
in any application. BOSTIK HOTLINE
RECOMMENDED COVERAGE
www.bostik.com
2 coats at 1kg/m2/coat.
an Arkema company