0% found this document useful (0 votes)
790 views

Calibration Certificate 2019 PDF

Uploaded by

Mishra Harshal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
790 views

Calibration Certificate 2019 PDF

Uploaded by

Mishra Harshal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 4
Format NoJ/ssue No : F-06b/02 Issue Date : 28-01-2014 QED Authentic Instrument & Automation Pvt. Lid. Certoate No 66-2238 CALIBRATION CERTIFICATE ULR NO.:C¢-2236000000059782/A, Date of Calibration : 29.09.2019 Next Suggested Date : 28.09.2020 (As per agreed with the Customer) [Service Request Gard No. £827(-4) ITEM'S DESCRIPTION & IDENTIFICATION Dated 27.09.2019]Nomenclature Current Meter Condition of the item OK|Make Logicstat INDENTOR'S DETAILS Model Mis: Shivalika Electricals & Engineers Serial No. ie 124/166 , Agarwal Farm , Ident. No. ‘SEE/RKT-O1 Mansarover , Jaipur (Ra). Range 999.99 Amp. Least Count O.1Amp. Location Relay Tost Kit(Secondary injection) MAJOR EQUIPMENT USED [Nomenclature ‘Ident. No. Traceability Cerificate No. Valid upto Multifunction calibrator 2999004 __C&lW/CAL/18-06/019 09.06.2020] ENVIRONMENTAL CONDITIONS PROCEDURE FOLLOWED Temperature 524°C [cPMo5 Humidity : (570) % ‘Sound Level <60 dB llumination Level 450-700 Lux CALIBRATION RESULT Oi ‘Current Meter Standard R UUC Reading Error 9.98 A 10.08 0.028 29.97 30.0.8 0.03.4 49974 50.0.8 0.03 A 69.964 70.0.4 0.04 A 89.97 A 90.0.4 0.03 A 99.994 1000 A 0.014 Current Meter The Expanded uncertainty associated with measurement at 95% Confidence Level at ‘coverage factor k= 2, is £ 0.60% Approved by a Le oi ae ee, (Calibration Engineer) hia ‘hotwara, Jaipur - 302012 (Rajasthan) INDIA. = re@autheniintrament. “Note : (The certificate is issued subject to conditions stated ovetea. Format No./Issue No : F-06a/02 Issue Date : 28-01-2014 Authentic Instrument & Automation Pvt. Ltd. Centiicate No: CC-2236 CALIBRATION CERTIFICATE ULR NO,:CC-2236000000059782 Date of Calibration ; 29.09.2019 Next Suggested Date : 28.09.2020 (As per agreed with the Customer) | Service Request Card No. 5827(|-4)|ITEM'S DESCRIPTION & IDENTIFICATION Dated 27.09.2019|Nomenelature Timer ‘Condition of the Item OK|Make Logicstat INDENTOR'S DETAILS |Model vs ls: Shivalikal Electricals & Engineers Serial No, : 124/166 , Agarwal Farm , Ident. No, ‘SEE/RKT-01 Mansarover , Jaipur (Raj). [Range 0-99 Sec Least Count 0.01 see Location Relay Test Kit(Secondary Injection) MAJOR EQUIPMENT USED [Nomenclature Ident. No. Traceability Certificate No. Valid upto [Digital Timer APLE-09 C&IW/CAL19-04/125, 29.04.2020] ENVIRONMENTAL CONDITIONS PROCEDURE FOLLOWED Temperature (2544) ECP(L)-21 Humidity (570) % Sound Level <60 08 iumination Level 450-700 Lux ‘CALIBRATION RESULT OF mer *UUG Reading | Standard Corrected | Uncortainity at Sec Sec 95% C List 19.98 20 0.24 29.99 30 0.24 49.99 50 0.24 69.98 70 0.24 79.99 80 0.24 89.98 90 024 Noto: *UUC : Unit Under Calibration 1.e, Timer The Expanded uncertainty associated with measurement at 95% Confidence Level at coverage factor =2, is as above under Uncertainty column, ved Checked By ere R uy te Me. 0. P Singh Mr Revi Singh (Calibration Engineer) Address :31, RICO Industrial Area, Near Kamani Choraha, sotwata, Jaipur - 302012 (Rajasthan) INDIA. Mobile: 93145-29100, 093524-54200, 09181-23798 (09181-23068, (Technical Manager) Email: [email protected] [email protected][email protected] Website :www.authenticinstruments.com ‘Note: (i) The certificates issued subject to conditions stated overleaf. Format No./issuo No : F-06b/02 Issue Date : 28-01-2014 aa: Authentic Instrument & Automation Pvt. Ltd. * CALIBRATION CERTIFICATE .c-2236000000059780 Date of Calibration ; 29.09.2019 Next Suggested Date : 28.09.2020 (As per agreed with the Customer), |Service Request Card No. ‘5827(I-4)| ITEM'S DESCRIPTION & IDENTIFICATION Dated 27.09.2019|Nomenclature Resistance Condition ofthe item oK|Make Waco INDENTOR'S DETAILS Model Ms: Shivalica Electcals & Engineers Seria No sase64 124/166, Agarwal Farm. lent No SEBIDERT-O1 Mansarover Jaipur (a) Range Oto 10000 Least Count ova [Location Digital Earth Resistance Tester MAJOR EQUIPMENT USED |Nomenclature Ident. No. Traceability Certificate No. Valid upto |Decade Resistance Box APLE-31 C&lJICAL/18-06/018 08.06.2020) |ENVIRONMENTAL CONDITIONS [PROCEDURE FOLLOWED Temperature 2544)" IcPM-o5 uty (<70)% Sound Level “6008 urnaten Love 450-700 Lux cal RESULT Rusisiance Meier *UUG Reading _| Standard Reading | Ewor 1.02 0 1a 0020 9.98.0 100 0.02.0 101.0 100 0 400.0 7019 700.0 400.0 02 0 00 0 2000 999.0 1000 a 4.004 Noto : “UC : Unit Under Calibration Le. Resistance ‘The Expanded uncrtaty sescited wth measurement et 6% Confidence Level a coverage facor k= 2, ls 40.50% Checked By ae ic ‘i au \ -} VP Nc Rav Singh th aces >alibration Engineer) (Technical Manager) ‘Address : 31, RIICO Industrial Area, Near Kamani Choraha, Jhotwaca, Jaipur = 302012 (Rajasthan) INDIA. Email Mobile: 093145-29100, 093524-54200, 09181-23798 09181-23068 calibration @authenticinstruments.com [email protected] [email protected] Website :www.authenticinstruments.com ‘Note: () The cetfcaeis issued subject o conditions stated overeat, Format NoJIssue No : F-06b/02 lesue Dato : 28-01-2014 QB Authentic instrument & Automation Pvt. Lid. (certeste No; 60-2208 ° CALIBRATION CERTIFICATE ULR No.:¢¢-2236000000059781 Date of Calibration : 29.09.2019 Next Suggested Dato : 28.09.2020 (As per agreed with the Customer) [Service Request Gard No. 5627(-4)|ITEM'S DESCRIPTION & IDENTIFICATION Dated 27.03.2019|Nomenctature Resistance Condition of the tom Ok|Make Meco IINDENTOR'S DETAILS Moder DIT 99D IW: Shivalka Electricals & Engineers Serial No. 124/166 , Agarwal Farm , Ident. No, SEE/DIT-02 Mansarover . Jaipur (Ra). Range 0-200 Ma/1000v Least Count 01M Location Digital Insulation Tester (Megger)_| MAJOR EQUIPMENT USED (Nomenclature ‘Ident. No. Traceability Certificate No. Valid upto [Decade Resistance Box __APLE-31 CBWICAL18-06/018, 08.06.2020 Multfunction calibrator 2998004 G&NICALIT8.06/019 (09.06.2020 [ENVIRONMENTAL CONDITIONS PROCEDURE FOLLOWED [Temperature : 524% |cPM-o5 Humiity (70) % [Sound Level: <60 dB [hiumination Level 450-700 Lux CALIBRATION RESULT OF Resistance Standard Reading | _ UUC Reading Error 19.84 MO 20.0 MO 0.16 MO 59.83 MO 60.0 Ma 0.17 MO 99.81 Mo 4100.0 Ma 0.19 Ma 199.82 MO 140.0 Ma 0.18 MO 179.80 MO 180.0 Ma 0.20 Mo 199.81ma | 200.0 Ma 0.19 Ma Note : “UUC : Unit Undor Calibration ie. Resistance ‘The Expanded uncertainty associated with measurement at 95% Confidence Level at coverage factor k= 2, is + 0.50% Checked By ‘Aporoved by Bo Ca Me Ri Sin . Sabra Ege) Me.0., Singh Saran Engines) (Technical Manager ‘Address :31, RIICO Industrial Arca, Near Kamani Choraha, Email: [email protected] Jhotvara, Jaipur 302012 (Rajasthan) INDIA. ‘upport@autheticinstrameatscom Mobile :093148-29100, 093524-54200, 099181-23798 | [email protected] —— ‘Website rwvemedicndcngtrmaets coum "*Note: (i) The cettficate is issued subject to conditions stated overeat.

You might also like