F7553e Watchdog

The document provides an overview of the F 7553 coupling module. The module monitors the 5V supply of an IO subrack and transmits a status signal to the central module. It has LED indicators for the watchdog signal and IO module access. A switch allows disabling the watchdog signal to change the module without triggering an emergency stop. Coding switches set the subrack and cabinet numbers on the IO bus. The module takes up 4 rack units and draws 600mA at 5V and 750mA at 24V during operation.

Uploaded by

evbaru
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
60 views

F7553e Watchdog

The document provides an overview of the F 7553 coupling module. The module monitors the 5V supply of an IO subrack and transmits a status signal to the central module. It has LED indicators for the watchdog signal and IO module access. A switch allows disabling the watchdog signal to change the module without triggering an emergency stop. Coding switches set the subrack and cabinet numbers on the IO bus. The module takes up 4 rack units and draws 600mA at 5V and 750mA at 24V during operation.

Uploaded by

evbaru
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

F 7553 (9912) Overview Data Sheets

F 7553
F 7553: Coupling module
in the assembly kit B 9302,
with switch-off of the watchdog signal,
for PES H51q

1 2 3 4
S1

WD
ON

LED WD on the front plate shows the existing fail-safe watchdog signal.
By the second LED SEL the access to the IO modules of the appertaining
IO subrack is signalled. Via the shrouded switch WD the WD signal can
be switched off to change the coupling module F 7553 without releasing a
system emergency-off.

The coding switches S1.1 ... S1.4 serves the setting of the numbers for the
IO bus (cabinet) and sub rack:

IO rack Switch S1. IO rack Switch S1.


1 2 3 4 1 2 3 4
switch upwards
1 1

2 2

3 3

4 4

5 5

6 6

7 7

8 8

IO bus 1 / Cabinet 1 IO bus 2 / Cabinet 2


The coupling module consists of the monitoring of the 5 V supply of the IO
subrack and transmits a corresponding status signal to the central modu-
le.
The module is automatically tested during operation.

Space requirement 4 TE
Operating data 5 V DC: 600 mA
24 V DC: 750 mA

All rights reserved. The technology is subject to changes without notice: 1/2