0% found this document useful (0 votes)
149 views

Ticket 23386

This document provides specifications for pumping an additive similar to diesel fuel oil with a density of 800-850 kg/m3 and viscosity of 4 mm2/s or 4 cP. It includes: - Flow rate requirements of 5-30 kg/hr - An operating pressure of 100 Psi (7 bar) - A pump and flow meter solution is proposed using a Tuthill DGS.23PPPT2NN00000 pump and Bronkhorst Coriolis M14-MGD-22.0-S flow meter. - Calculations are shown verifying the pump can handle the minimum and maximum flow rates at the operating pressure while maintaining the manufacturer's pressure limits.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
149 views

Ticket 23386

This document provides specifications for pumping an additive similar to diesel fuel oil with a density of 800-850 kg/m3 and viscosity of 4 mm2/s or 4 cP. It includes: - Flow rate requirements of 5-30 kg/hr - An operating pressure of 100 Psi (7 bar) - A pump and flow meter solution is proposed using a Tuthill DGS.23PPPT2NN00000 pump and Bronkhorst Coriolis M14-MGD-22.0-S flow meter. - Calculations are shown verifying the pump can handle the minimum and maximum flow rates at the operating pressure while maintaining the manufacturer's pressure limits.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 7

Ticket 233386 Coriolis

Question:
Additive properties:
Fuel liquid similar to diesel (fuel oil # 4)
Density = 800 - 850 kg / m3
Viscosity = 4 mm2 / s
Temperature = 30 ° C
Operating pressure = 100 Psi (7 bar) maximum
Minimum flow = 5 Kg / hr
Maximum flow = 30 Kg / hr

Our application will obtain the additive from an atmospheric tank, so a pump is required to
drive it to the dosing point according to the following diagram:

Viscosity = 4 mm2 / s
convert to CP (same as mPa.s) = 4 CP

according to source https://www.engineeringtoolbox.com/viscosity-converter-d_413.html


Please check if we used corect viscosity value.
When not the calculated products can't be used.

Remark:
· One (1) virtualy pulse-free gear pump
· One (1) mini CORI-FLOW mass flow meter and controller

We don’t offer pump + MFC but pump + flow meter (as in your dwg)
We assume drawing is correct (this is standard)
Out quotation will be based upon a pump + coriolis flow meter only
Calculation:
Calculated wit density 825 kg/m3
Flow 30 kg/h and minimum flow 5 Kg/h

We calculated with 7 bar(g) process pressure. Make sure this is correct!


If not solution could not work
1) Flow 30 kg/h
Process pressure = P2 of coriolis 7 bar(g)
For tuthil pump:
Pinlet= 0bar(g)
Poutlet tuthil = Pinlet M14 = 12.08 bar(g) + safety marging 1 bar = 13.1 bar(g)

Tuthil pump can handle max. 17 bar(d) so this will be ok.

Density: 0.825 specific gravity = 825 kg/m3

Needed:
1* DGS.23PPPT2NN00000 + BG45 Magnetically coupled gear pump

(Below advise is advised based upon your information: “diesel like medium”)
-Seals: PTFE (Teflon)
-Gears + Bearings: PPS
-Material: ss316

This is standard for Tuhil pump


Flow conversion factor compared to water
30 kg/h = 30 l/h water

Density custon fluid: 825 kg/m3


--------------- : * 30 kg/h = 24.75 kg/h = 24.75 l/h
1000

We calculate for 30 l/h to have a save margin

2) Flow 5kg/h

For tuthil pump:


Pinlet= 0bar(g)
Poutlet tuthil = Pinlet M14 = 7.549 bar(g) + safety marging 1 bar = 8.55 bar(g)
Flow conversion factor compared to water
5 kg/h = 5 l/h water

Density custon fluid: 825 kg/m3


--------------- : * 5 kg/h = 4.125 kg/h = 4.125 l/h
1000

We calculate for 5 l/h to have a save margin

Conclusion: also for the low flow the DGS .23 tuthil (calculated for the 30kh/h flow above) will work too.
RPM >400 so no bypass needed

Conclusion:

Needed:

1* 7.11.468 DGS.23PPPT2NN00000 + BG45 Magnetically coupled gear pump


Price: euro 2314.- nett price

1* 7.03.562 cable dunckermotor


(Price included)

1* 1.16.051 power supply 24v/150W 6.25 A


(Price included)

1* Coriolis M14-MGD-22.0-S
Price: euro 3501.- euro nett price

1* 5.02.005 Mass block for optimal stability and accuracy


Both Tuthil and M14 coriolis will be build on a 4KG mass block.

Bronkhorst only can profide 1 solution/combination on 1 mass block


Remark: 6 combinations on 1 special designed BIG mass block is not possible!

1* 5.02.007 mounting acc. Mass block


(Price included)
1* 7.20.018 System test
Price: included

1* 7.03.357
Price: euro 82.- nett price

Electrical connection:
-Power supply to tuthil pump (to be quoted)
-Coriolis will receive power by Modbus (from customer system)
-M14 has din 8 connector.
You ask for: o Communication accessories for Modbus with RJ type accessories
Then needed:

Note: avoid double power supply on M14 coriolis.


Modbus will power M14 by a M12 connector. Do not connect a power source to DIN 8 connector.
This will damage the instrument.

Customer must use his rj45 modbus cable and other accessoiries needed to connect to his modbus system.

1* 7.03.191
Price: euro 44.- nett

RS-232 control:
The DIN 8 provides this.
Control also possible on Modmus