Material
Material
MECHANICAL PROPERTIES
Designation Heat treatment °C Test at room temperature Test at elevated temperature
Impact
Normalizing Tempering Tensile test test Tensile test
Name Number Symbol 2) (+ N) or (+T) Rp0,2 Rm A KV Rp0,2 Mpa *) min at °C
Quenching Mpa *) Mpa *) % J
100° 200° 300° 350° 400° 450° 500° 550°
(+ Q) 1) min min min.
GP240GH 1.0619 + N 900 to 980 -- 240 420 to 600 22 27 210 175 145 135 130 125 -- --
+ QT 890 to 980 600 to 700 240 420 to 600 22 40 210 175 145 135 130 125 -- --
G20Mo5 1.5419 + QT 920 to 980 650 to 730 245 440 to 590 22 27 -- 190 165 155 150 145 135 --
G17CrMo5-5 1.7357 + QT 920 to 960 680 to 730 315 490 to 690 20 27 -- 250 230 215 200 190 175 160
G17CrMo9-10 1.7379 + QT 930 to 970 680 to 740 400 590 to 740 18 40 355 345 330 315 305 280 240
GX15CrMo5 1.7365 + QT 930 to 990 680 to 730 420 630 to 760 16 27 -- 390 380 -- 370 -- 305 250
1) +Q means quenching media: air or liquid. +T = tempering. +N = normalizing
2) If there are alternative specifications for heat treatment, the requested alternative shall be indicated on the order, e.g.: GP240GH +QT1 or 1.0619 +QT1
*) 1 Mpa = 1N/mm 2