User Manual of Coding Intercom For Apartment
User Manual of Coding Intercom For Apartment
com
CODING INTERCOM
USER’’S
USER MANUAL
0
www.cusamintercom.com
Contents
Section Description page
▲ Main Products---------------------------------------------2-3
▲ Description of indoor phone-------------------------------4
▲ Description of Door station--------------------------------5
▲ System features----------------------------------------------6
Ⅱ、Technical parameter-------------------------------------------6
Ⅲ、Code setting--------------------------------------------------7-9
Ⅸ、Attentions---------------------------------------------------19-21
1
www.cusamintercom.com
1、System
System instruction
▲ Main Products
Door station
2
www.cusamintercom.com
Indoor phones
3
www.cusamintercom.com
4
www.cusamintercom.com
5
www.cusamintercom.com
▲ System features
It is with all functions and features that video and audio coding
intercom system have
Ⅱ、Technical parameter
·Working voltage:DC10.8V~16V
·The undistorted power of output:
The main channel: 5mw min
The reply channel: 100mw min
·Frequency response:300~3400HZ±3db
·Environment temperature :-40℃ to +70℃
·Humidity:45% to 95%
·Working current of camera:500mA±20mA
·Camera:1/3″ CCD
·Definition:380 TV Line
6
www.cusamintercom.com
Ⅲ、Code
Code setting
☆ The door station provides a quick order "**41" if the room number
encoding method conforms to the rule of table 1, Just do as
follows:press **00, XXXX (manager password), **41, then it will
come to the programming rule as table one does.
☆ The door station provides a quick order "**42" if the room number
encoding method conforms to the rule of table 2,
7
www.cusamintercom.com
☆ The door station provides a quick order "**43" if the room number
encoding method conforms to the rules of table 3.Use order “**40” to
eliminate the comparative table of the module address and the room
number".
☆ The manipulating setting of the extension phone number: press **15
and come up with Y011 after completes steps 1, 2, 3 (Y stands for the
address, the 2nd and 3rd figure stand for the coding site, and the 4th figure
is the room number).Entering three numerals if you want to revise the
address, and press the key "*" if you don’t want to. It’ll show four
numerals after finishing the above steps.Please enter four numerals to
revise (namely room number), press "*" if do not revise (namely
examination), and then it will demonstrate the next encoding address. If
the four figures have been in table (namely repetition), and it’ll show
the repetitious number address. Then please enter 0000,that mean you
don't use this address.
☆ The module(see the picture in the right corner),
the address of module ranges from 0101 to 9904.
Namely the coding sites are 01 to 99 (namely
floors are 01 to 99), room number are 01 to 04.
The first 8,421 is decimal and the latter 8,421 is
the single. There are eight pairs of two sides
contact pin.
8
www.cusamintercom.com
The room number 01-04 should be inserted in R01, R02, R03, R04
accordingly.
(for example) If the room number you want is 1301, insert the block
of short-circuits to the single 1 and 2 and decimal 1,and the room number
cut over to R01 then. The comparative table of room number and module
address, see details in 6,and 7 pages,
Ⅳ、Use
Use method and problem dealing
problem
1. The visitor can input the room number directly when he /she comes.
Press “#” to eliminate and re-input when you input wrong number, then the
extension telephone will have the ring sound. meanwhile, the indoor phone
9
www.cusamintercom.com
displays the image automatically. Pressed the unlock button which control
the electronic lock of the front gate after confirming the visitor. And the
image will shut-off automatically after hanging off the phone. If the coding
is 3 and 4 dialing mixly, for example: you can dial 101 or 0101 either.
2. The gate will be shut off by the closing machine automatically after
the visitor entering into the door.
3. The system may maintain the work by the reserving power source
when the power is off,
5. There are three potentiometers in the door station, which are “the
mainframe”, ” the extension phone” and "the balance". "The mainframe"
uses to adjust the volume of the door station; "The extension phone" uses to
adjust the volume of indoor phones, which limits in some range, and don’t
attempt to adjust the volume of indoor phone and break potentiometer; "The
balance" use to eliminate the sidetone.
10
www.cusamintercom.com
7. When the door station call indoor phones,and it sends two "di , di "
sound , that mean it cann't detect the indoor phone, If it sends three "di, di,
di " sound, that mean the wire of the indoor phone is short-circuits. When
the door station call all indoor phones,they are unnormal or no sound,then it
maybe the failure of main wire.
11
www.cusamintercom.com
12
www.cusamintercom.com
13
www.cusamintercom.com
(module
(module (module (module
address) (room (room (room (room
address) address) address)
(coding number) number) number) number)
(coding site) (coding site) (coding site)
site)
14
www.cusamintercom.com
15
www.cusamintercom.com
16
www.cusamintercom.com
Ⅵ、Door
Door station setting order
CODE
DIGIT CODE Significance remark
ORDER
*000 XXXX The manager operates the lock
It should be confirm the manager password first
XXXX Confirmating the manager
**00 before using the order from **00 to **19
(4 passwords) password
(Tacitly approves No, is 2098)
XXXX
**01 Revising the manager password
(4 new passwords)
the efficient number are 1.2.3.6.7.8.9.0
**02 000X Revising the coding method ”0” is the onmipotent coding (Tacitly approves
No, is 2)
**03 0XXX Revising the ringing time 001-255seconds(Tacitly approves No, is 60)
**04 0XXX Revising the Dialogue time 001-255seconds(Tacitly approves No, is 120)
0-9(0 is the “dingdong” sound, and 1-9 is the
**05 000X Revising the ring types
phone sound) (Tacitly approves No, is 0)
001-255seconds(the user also can answer the
Revising the waiting time after
**06 0XXX phone after the ring stopped) (Tacitly approves
ringing
No, is 1)
001-255seconds(unit is 0.2 second, tacitly
Revising the time of operating
**07 0XXX approves No, is 5,namely the time of unlocking
lock
is 1 second)
Revising the waiting time after 001-255seconds(the talking time after opening
**08 0XXX
opening the door the door) (Tacitly approves No, is 20)
demonstration type at standby 0-9 (Tacitly approves No, is 1)(0-off,1-9 are
**09 000X
state demostrating)
Controlling thecode tube to 0-1(Tacitly approves No, is 1)
**10 000X demonstrate or to slake when 0 is to slake
picking up phone 1 is to demonstrate
000-255seconds,000-close the alarm function.
**11 0XXX revising the alarm time
(Tacitly approves No, is 000)
0XXX(Serial
Manager revising the unlock The scope of Serial number:000-239
**12 number)
password of users password cancelling:0000
XXXX(password)
establishing eight public
**13 XXXX XXXX password cancelling:0000
password to open locks
YXXX(module edits comparative table of " Reference the comparative table of " onmipotent
**15
address) onmipotent coding " coding "
Only suit for the onmipotent coding the
**16 000X choosing the " dialing digit" effective number is 1.2.3.4,(Tacitly approves No,
is 3)
Which digit to demonstrate a The effective digit is 1-4,or the tacitly approves
**17 000X
letter demonstrate no letter
Checking the room number of Checking the module address of the room
**18 XXXX(room No.)
onmipotent coding number in table “onmipotent coding”
Restoring the digits **02-**11,**16-**17 are
**19 Restoring factory setting
the factory tacitly approves No,
17
www.cusamintercom.com
Ⅶ、User
User
User’’s operational order
Ⅷ、Wrong
Wrong code form
18
www.cusamintercom.com
Ⅸ、Attention
Attention
Attentionss
The video and audio indoor extension phone can be used both in
networking and non-networking system.It's good for non-networking
upgrading to networking system.
If the door station promotes to the networking system, then just replace the
control chip of the non- networking door station
1. The section area should be bigger than 0.3mm2 ,if the length of
master line is less than 50M
2. The section area should be bigger than 0.5mm2 ,if the length of
master line is between 50M and 100M
3. The section area should be bigger than 0.15mm2 ,if the length of
branch line is less than 20M
4. The section area should be bigger than 0.3mm2 ,if the length of
branch line is between 20M and 50M
19
www.cusamintercom.com
5. The wire that from the power source to the door station and door
station to locks, the section area of which should be bigger than 0.5mm2,
and the length have to be less than 15M, otherwise should enlarge the area
of wire
★the possible problems if the wiring does not conform to the request :
1. If the section area of mian line or branch line is too slim, it may
cause the indoor phones don’t work when it is picked up or hanged off,can’t
unlock the gate,or the low volume of indoor phones and things like that.I
2. The section area of the wire that from power to door station and
door station to electronic lock is too slim.then it may cause the indoor
phone can’t unlock the door.
Visible partially has two electric wires, one is for the surveillance
requests (M), the other is for the video coaxial cable (vi). The video
coaxial cable system uses SYV75-3, and should pay attention that the outer
layer shield cann’t use as the wire to supply power, otherwise it possibly
causes the power source and undulation interfering picture
20
www.cusamintercom.com
The section area should be bigger than 0.5mm2 when the length of
electric wire is less than 30M,
The section area should be bigger than 0.75mm2 when the length of
electric wire is less than 50M
The section area should be bigger than 1.0mm2 when the length of
electric wire is less than 80M,
The section area should be bigger than 1.5mm2 when the length of
electric wire is more than 80M,
General speaking,every 4 to 8 floors should add a power source for
video, at this time,you can let up the section area of wire suitably.
There is no special request that the line of surveillance requested to the
section area of wire.
21