0% found this document useful (0 votes)
341 views2 pages

06 02 00 1FT PDF

The document describes the FA 3000 i load cell for weighing hoppers, tanks, and scales. It comes in various capacities from 10kg to 500kg with accuracy classes of D1, C3, and C6. It is made of stainless steel for use in severe environments and measures load through strain gauges. It has an IP67 degree of protection and explosive area certification is available as an option.

Uploaded by

Ram Mugesh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
341 views2 pages

06 02 00 1FT PDF

The document describes the FA 3000 i load cell for weighing hoppers, tanks, and scales. It comes in various capacities from 10kg to 500kg with accuracy classes of D1, C3, and C6. It is made of stainless steel for use in severe environments and measures load through strain gauges. It has an IP67 degree of protection and explosive area certification is available as an option.

Uploaded by

Ram Mugesh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

FA 3000 i

Bending beam load cells


08/2005 06-02-00-1 FT

Applications Different capacities of the FA 3000 i(C3)


# Weighing of hoppers, tanks.
D1
# Scales.
# Renovation of scales and mechanical weighbridges.
Minimum Breaking
Type Capacity Load limit
increment load

Presentation FA 3000 i 10 10 kg 3.6 g 15 kg 30 kg


FA 3000 i 20 20 kg 7.2 g 30 kg 60 kg
Description FA 3000 i 50 50 kg 18 g 75 kg 150 kg
# Fully designed in stainless steel for use in severe environments. FA 3000 i 100 100 kg 36 g 150 kg 300 kg
# Measurement of the deformation of beams by strain gauges installed FA 3000 i 200 200 kg 72 g 300 kg 600 kg
in Wheatstone bridge (signal proportional to the load to be
measured). FA 3000 i 500 500 kg 180 g 750 kg 1500 kg
# Accuracy class : D1, C3 and C6*
# Degree of protection : IP 67 C3
# Capacity : 10 - 20 - 50 - 100 - 200 - 500 kg
Type Capacity Minimum Load limit Breaking
increment load

Conformity FA 3000 i 10 10 kg 0.9g 15 kg 30 kg


FA 3000 i 20 20 kg 1.8 g 30 kg 60 kg
# Test certificate issued by a notified body in accordance with OIML
recommendation R60. FA 3000 i 50 50 kg 4.5 g 75 kg 150 kg
FA 3000 i 100 100 kg 9g 150 kg 300 kg
FA 3000 i 200 200 kg 18 g 300 kg 600 kg
Option FA 3000 i 500 500 kg 45 g 750 kg 1500 kg
# Ex version for use in explosive area. (EEx ia II C T6 II 2 G).
(IP67 T80°C II 2 D) C6

Type Capacity Minimum Load limit Breaking


increment load

FA 3000 i 50 50 kg 3.3 g 75 kg 150 kg


FA 3000 i 100 100 kg 6.6 g 150 kg 300 kg
FA 3000 i 200 200 kg 13.2 g 300 kg 600 kg

* 50, 100 and 200 kg only.

/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / // / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Technical data
Dimensions Metrological characteristics
# Sensitivity ................................................... 2 mV/V
# Total error.................................................... < 0,02 %
# Non-repeatability ........................................ < 0,005 %
# Temperature effect on zero balance ........... < 0,0014 % / °C
# Temperature effect on sensitivity ............... < 0,0009 %

Electrical characteristics
# Power supply voltage : nominal ................................ 0,5 à 12 V
# Power supply voltage : maximum ............................. 18 V
# Input impedance ....................................................... 350 à 390 Ω
# Output impedance .................................................... 356 Ω
# Insulation .................................................................. > 5 000 MΩ
# Cable
• Length ..................................................... 3m
• Colors :

Power supply+ Blue Signal + White


Return + Green Signal - Red
Metallic bellows ø 42 Power supply - Black Shielding Yellow
Return - Gray

A (mm) B(mm) Environment


5 à 200 kg 8,2 8,2 # Temperature range
500 kg 10,5 11,1 • Recommended ........................................ - 10 °C / + 40 °C
• Without modification ................................ - 20 °C / + 60 °C
• Storage .................................................... - 40 °C / + 80 °C
# Sealing and protection................................. IP 67

Options
# Environment with ball # Environment with shock absorber # Environment with pulling rod

//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

Your weighing specialist Illustrations are not contractual. Precia-Molen reserves


the right to modify at any time, without prior notice, the
information contained in this leaflet.

Offices and Factory


P.O. Box 106 - F 07000 Privas - France
Tel. 33 (0) 475 664 600
Fax 33 (0) 475 658 330
E-MAIL [email protected]
RCS : 386 620 165 RCS Aubenas

You might also like