2 & 4 Pole RCBOs provide residual circuit breaker with overload protection and RCD earth leakage protection in a single compact device. They come in various current ratings from 6A to 40A and have B and C time-current curves. RCBOs detect residual alternating currents as well as DC fault currents from equipment. They comply with safety standards and provide protection against electrical shocks from direct or indirect contact.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
185 views

RCBOs

2 & 4 Pole RCBOs provide residual circuit breaker with overload protection and RCD earth leakage protection in a single compact device. They come in various current ratings from 6A to 40A and have B and C time-current curves. RCBOs detect residual alternating currents as well as DC fault currents from equipment. They comply with safety standards and provide protection against electrical shocks from direct or indirect contact.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

2 & 4 Pole RCBOs

(Residual Circuit Breaker with Overload) B & C Curves


Description Connection capacity Approved according to
Compact protection devices rigid conductors: 25mm² EN 61009-1.
which provide MCB overload ĻH[LEOHFRQGXFWRUVPP
protection and RCD earth
leakage protection (protect Technical information
against electrical shocks by s A type: Detects residual
direct or indirect contact). sinusoidal alternating currents,
whether suddenly applied or
Technical data slowly rising. They are used
s sensitivity: whenever fault currents are not
High sensitivity: 30mA instant sinusoidal. It is able to detect
WULSSLQJ ĺ[HG  DC fault current generated by
Medium sensitivity: 300mA loads like washing machines,
LQVWDQWWULSSLQJ ĺ[HG  speed drives, microprocessing,
s current rating: 6 to 40A electronic ballast.
s curves: B and C
s voltage rating: 230V AC
s A type
s frequency: 50Hz

Description Breaking In/A Width in I Pack Cat. ref.


capacity 17.5mm qty. B curve C curve
(IEC 60 898-1)

RCBOs 6kA 6A 2 1 AD906J


A type - 30mA 10A 2 1 AD910J

Protection Devices
16A 2 1 AD916J
20A 2 1 AD920J
25A 2 1 AD925J
32A 2 1 AD932J
40A 2 1 AD940J

RCBOs 6kA 6A 2 1 AF956J


A type - 300mA 10A 2 1 AF960J
16A 2 1 AF966J
20A 2 1 AF970J
25A 2 1 AF975J
AD916J 32A 2 1 AF982J
40A 2 1 AF990J

RCBOs 6A 4 1 ADM406C
A type - 30mA 6kA 10A 4 1 ADM410C
13A 4 1 ADM413C
16A 4 1 ADM416C
20A 4 1 ADM420C
25A 4 1 ADM425C
32A 4 1 ADM432C
40A 4 1 ADM440C

RCBOs 6A 4 1 ADM456C
A type - 30mA 6kA 10A 4 1 ADM460C
13A 4 1 ADM463C
16A 4 1 ADM466C
20A 4 1 ADM470C
25A 4 1 ADM475C
32A 4 1 ADM482C
40A 4 1 ADM490C

ADM456C

4.13
RCBO
Single Pole 6kA
Compact protection devices Technical Data Application
which combine the overcurrent Insulated DIN clip 1 module devices provide a
functions of an MCB with the Complies with BS EN 61009-1, compact solution for installation
earth fault functions of an RCCB IEC61009-1, IEC610009-2-2, in consumer units.
in a single unit. A range of 6HQVLWLYLWLHV ĺ[HG 
sensitivity and current ratings 10mA and 30mA These devices are 1pole & solid
are available for use in domestic Breaking capacity: 6kA neutral.
installations. Flying neutral lead: 200mm
Operating Voltage
Terminal Capacities 230V(AC) + 10%/-15% 50H
25mm2 rigid,
16mm2ĻH[LEOH Locking kit = MZN175

Description In/A Width in ] Cat. ref.


17.5mm B curve

Sensitivity 30mA (6kA) 6A 1 Mod ADN106


Type B, AC Sensitive
10A 1 Mod ADN110

16A 1 Mod ADN116

20A 1 Mod ADN120

32A 1 Mod ADN132

40A 1 Mod ADN140

45A 1 Mod ADN145


ADN120
50A 1 Mod ADN150

Sensitivity 30mA (10kA) 6A 1 Mod ADA156U


Type C, DC Sensitive
10A 1 Mod ADA160U

16A 1 Mod ADA166U

20A 1 Mod ADA170U

32A 1 Mod ADA182U

Description Characteristics Cat. ref.

Locking Kit This allows locking of the device MZN175


toggle in the off position.

Will accept two padlocks with


hasps of 4.75mm diameter max.
(supplied without padlock).
MZN175

4.14
RCBO (Commercial / Industrial)
Single Pole 10kA
Compact protection devices Technical Data Terminal Capacities These devices are single pole &
which combine the overcurrent Insulated DIN clip 16mm2 rigid, solid neutral.
functions of an MCB with the Complies with BS EN 61009-1, 10mm2ĻH[LEOH
earth fault functions of an RCCB IEC61009-1
in a single unit. A range of 6HQVLWLYLWLHV ĺ[HG  Application
sensitivity and current ratings are 10mA, 30mA & 100mA 1 module devices provide a
available for use in commercial Breaking capacity: 10kA compact solution for installation
and industrial applications. Flying neutral lead: 800mm in consumer units and Invicta 3
distribution boards.

Description In/A Width in ] Cat. ref.


17.5mm B curve C curve

Sensitivity 10mA (10kA) 6A 1 Mod ACB106 ACC106

16A 1 Mod ACB116 ACC116

25A 1 Mod ACB125 ACC125

32A 1 Mod ACB132 ACC132

Sensitivity 30mA (10kA) 6A 1 Mod ADB106 ADC106


ACB125
10A 1 Mod ADB110 ADC110

16A 1 Mod ADB116 ADC116

20A 1 Mod ADB120 ADC120

Protection Devices
25A 1 Mod ADB125 ADC125

32A 1 Mod ADB132 ADC132

40A 1 Mod ADB140 ADC140

ADB106 45A 1 Mod ADB145 -

Sensitivity 100mA (10kA) 10A 1 Mod - AEC110

16A 1 Mod - AEC116

20A 1 Mod - AEC120

25A 1 Mod - AEC125

32A 1 Mod - AEC132


AEC132
Sensitivity 10mA (10kA) 1 Mod ADA106U
Class A
1 Mod ADA110U

1 Mod ADA116U

1 Mod ADA120U

1 Mod ADA125U

1 Mod ADA132U
ADA106U

Description Characteristics Cat. ref.

Locking Kit This allows locking of the device MZN175


toggle in the off position.

Will accept two padlocks with


hasps of 4.75mm diameter max.
(supplied without padlock).
MZN175

4.15