1) An AC supply with an input AC line voltage of 400V at 50 Hz is connected 1 point
Week 2
with three-phase three-wire delta connected balanced load having ZL= (4.0+j2.0) pu and
Week 3
a base impedance of 5Ω per phase. It is to be realized as a unity power factor load on the
AC supply system using shunt connected lossless passive elements (L and/or C)
Shunt Calculate compensator currents,….A
Compensator
TCR and TSC -
8A
I
6A
Shunt
Compensator 5A
TCR and TSC -
II 7A
Static Var No, the answer is incorrect.
Compensator - Score: 0
I
Accepted Answers:
Static Var 8A
Compensator -
II 2) Calculate the values of compensator elements (in farads or henries) in above 1 point
STATCOM - I question Number Q1,
Funded by
VIDEOS Powered by
21 ohms
No, the answer is incorrect.
Score: 0
Accepted Answers:
25 ohm
4) A single-phase AC supply has Rms voltage of 230 V at 50 Hz and a feeder 1 point
(source) impedance of 1.0Ω resistance and 4.0Ω inductive reactance after which a
single-phase load having ZL=(16 +j12) Ω is connected. If a shunt compensator consisting
of a lossless passive element (L or C) is used to raise the voltage to the input voltage (230
V) and make the unity power factor, calculate the value of the compensator element (in
farads or henries)
129.51 microfarad
119.51 microfarad
139.51 microfarad.
None of this
No, the answer is incorrect.
Score: 0
Accepted Answers:
139.51 microfarad.
5) In above question Q4, The voltage drop across the source impedance after 1 point
compensation is
40.12 V
38.12 V
40.63 V
40.92 V
No, the answer is incorrect.
Score: 0
Accepted Answers:
40.12 V
6) A three phase AC 400 V, 50 Hz distribution system connected with three-phase 1 point
three-wire shunt compensator consisting of lossless passive elements (L and/or C) Is
employed to provide load balancing and power factor correction of a single-phase 50
kVA, 0.7 lagging power factor load connected between two lines (between phase A and B
only). Calculate compensating current Icab (which compensator is connected between
phase A and B).
86.03 A
87.15 A
50.31 A
58.91 A
No, the answer is incorrect.
Score: 0
Accepted Answers:
86.03 A
7) In above question A3Q6 the values of compensator elements (farads or henries) 1 point
are …..
Cab=710 microF
Cab=385 microf
Lca=26 mH
Lca=56 mH
No, the answer is incorrect.
Score: 0
Accepted Answers:
Cab=710 microF
Lca=26 mH
8) A three-phase four-wire unbalanced load having ZLa=(6.0+ j3.0) pu 1 point
connected between phase A and neutral terminal is fed from an AC supply
with an input line voltage of 415V at 50 Hz and a base impedance of 4.15Ω
per phase. It is to be realized as a three-phase balanced unity power factor
load on the three-phase supply system using a shunt compensator consisting
of lossless passive elements (L and/or C) Calculate the values of
compensator elements ( in farads) between phase A and B(assume
compensator are delta connected )
39.38 microF
41.38 microF
42.38 microF
43.38 microF
No, the answer is incorrect.
Score: 0
Accepted Answers:
39.38 microF
9) In above question number Q8. Calculate compensator elements ( in 1 point
farads) between phase C and N
57.075 microF
58.075 microF
59.075 microF
60.075 microF
No, the answer is incorrect.
Score: 0
Accepted Answers:
59.075 microF
10)In above question number Q8. Calculate its KVA rating, 1 point
7.012 KVA
7.112 KVA
7.212 KVA
7.312 KVA
No, the answer is incorrect.
Score: 0
Accepted Answers:
7.312 KVA